| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK 4563 |
| Measurement Angles | 20°, 60°, 85° |
| Compliant Standards | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Display | Full-color TFT screen with intuitive navigation |
| Calibration | Integrated auto-diagnostic system with certified reference standard stored in protective calibration base |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–20 GU), ±0.5 GU (20–100 GU), ±0.5% (100–2000 GU) |
| Measurement Area | 20°: 10×10 mm, 60°: 9×15 mm, 85°: 5×38 mm |
| Data Interface | USB |
| Software Compatibility | smart-lab Gloss & smart-process Gloss (30-day free trial per package) |
| Brand | BYK-GARDNER |
|---|---|
| Country of Origin | Germany |
| Model | BYK 4565 |
| Type | Automatic Tri-angle Gloss Meter |
| Measurement Angles | 20°, 60°, 85° |
| Gloss Range | 0–2000 GU |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741, GB/T 9754 |
| Display | Full-color TFT touchscreen |
| Interface | Bluetooth 5.0, USB-C |
| Data Storage | Internal memory (≥10,000 readings), SD card slot |
| Software Compatibility | smart-chart™ v5.x, smart-lab™ Gloss |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK-Micro-TRI-Gloss 4567 |
| Type | Automatic |
| Transmission Range | 0–100% |
| Transmission Repeatability | ±0.2% |
| Measurement Angle | 45° |
| Measuring Spot Size | 9 × 13 mm |
| Compliant Standards | ASTM D2457, ISO 2813, JIS Z8741, TAPPI T 480, DIN 67530 |
| Brand | BYK-Gardner |
|---|---|
| Country of Origin | Germany |
| Model | BYK 4568 |
| Type | Automatic |
| Transmission Range | 0–100% |
| Transmission Repeatability | ±0.2% |
| Measurement Angle | 75° |
| Application Focus | Paper, Paperboard, Coated & Uncoated Substrates, PVC Vinyl Wall Panels |
| Compliant Standards | ASTM D2457, ASTM D3679, TAPPI T 480, JIS Z 8741 |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK 4569 |
| Measurement Angles | 60° only |
| Aperture Size | 2 × 4 mm |
| Gloss Range | 0–2000 GU |
| Repeatability | ±0.2 GU (0–100 GU), ±0.2% (100–2000 GU) |
| Reproducibility | ±0.5 GU (0–100 GU), ±0.5% (100–2000 GU) |
| Spectral Response | CIE standard observer (illuminant C) |
| Measurement Time | 0.5 s |
| Substrate Compatibility | Fe (magnetic) and NFe (non-magnetic) |
| Coating Thickness Range | 0–500 µm |
| Thickness Accuracy | ±(1.5 µm + 2% of reading) |
| Memory Capacity | 999 readings with timestamp |
| Interface | USB |
| Power | 1 × AA alkaline battery (≈4,000 measurements) or USB bus power |
| Dimensions | 155 × 73 × 48 mm |
| Weight | 0.4 kg |
| Operating Temperature | 15–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Brand | BYK-GARDNER |
|---|---|
| Origin | Germany |
| Model | BYK4570 |
| Type | Automatic |
| Gloss Range | 0–20 GU (low-gloss mode), 20–100 GU, 100–2000 GU |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Measurement Spot Size | 2 mm × 4 mm |
| Compliant Standards | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK 4566 |
| Measurement Angles | 20°, 60°, 85° |
| Display | Full-color TFT touchscreen |
| Interface | USB |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Measurement Range | 0–2000 GU (angle-dependent) |
| Repeatability | ±0.1 GU (0–20 GU), ±0.2 GU (20–100 GU), ±0.2% (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–20 GU), ±0.5 GU (20–100 GU), ±0.5% (100–2000 GU) |
| Probe Type | Dual-mode (magnetic/non-magnetic) for coating thickness integration |
| Optional Thickness Measurement | ISO 2360, ISO 2808, ASTM B499, D1400 |
| Calibration | Traceable certified standard tile included |
| Software Compatibility | smart-lab Gloss & smart-process Gloss (30-day trial, dual-license) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | C84-III-B |
| Pricing | Available Upon Request |
| Measurement Range | 0–100 % |
| Resolution | 0.1 % |
| Accuracy | ±1 % |
| Repeatability | ±0.3 % |
| Operating Temperature | 20 °C ± 5 °C |
| Relative Humidity | < 85 % RH |
| Power Supply | 220 V ± 10 %, 50 Hz |
| Compliance | GB/T 13452.3–1992, GB 9270–1988, GB 5211.17–1988, ISO 3906:1980(E) |
| Brand | Calmar Laser |
|---|---|
| Model | CFL-05RFF0 |
| Wavelengths | 780 nm and 1550 nm (manually switchable) |
| Average Power | up to 0.8 W @ 780 nm, up to 2.5 W @ 1550 nm |
| Pulse Width | < 80 fs @ 780 nm, < 100 fs @ 1550 nm |
| Repetition Rate | 10–80 MHz (fixed per unit) |
| Beam Quality (M²) | < 1.2 @ 780 nm, < 1.1 @ 1550 nm |
| Polarization Extinction Ratio | > 25 dB @ 780 nm, > 18 dB @ 1550 nm |
| Power Stability | < 1% RMS over operating temperature range |
| RF Sync Output | 0.5 V TTL-compatible, SMA connector |
| Cooling | Air-cooled (low-noise fan) |
| Warm-up Time | ≤ 10 min |
| Laser Head Dimensions | 9.0 × 13.0 × 3.0 cm |
| Controller | 2U 19″ rackmount (44 × 42 × 9 cm) |
| Input Power | 85–264 VAC, 47–63 Hz, 200 VA max |
| Output Termination | Free-space collimated beam |
| Fiber Coupling Option | Available upon request |
| Brand | Calmar Laser (OEM series by Auniontech) |
|---|---|
| Wavelengths | 780 nm, 925 nm, 1030 nm, 1064 nm, 1550 nm |
| Pulse Width | <90 fs – 10 ps (model-dependent) |
| Repetition Rate | 1–100 MHz (typ.) |
| Average Power | 0.5–200 mW (model-dependent) |
| Spectral Bandwidth (FWHM) | 0.5–30 nm (wavelength- and model-dependent) |
| Output Configuration | Free-space or fiber-coupled (PM or non-PM) |
| Power Supply | +5 V DC |
| Compliance | RoHS-compliant optical module architecture |
| Form Factor | OEM-integrated module or benchtop-ready unit |
| Brand | MOGLabs |
|---|---|
| Model | CEL Series |
| Type | Cat’s-Eye External Cavity Diode Laser (ECDL) |
| Wavelength Range | 369.5 nm – 1550 nm (model-dependent) |
| Output Power | Up to 250 mW |
| Linewidth | < 100 kHz (with MOGLabs controller) |
| Tuning Mechanism | Cat’s-eye retroreflector + narrowband interference filter (replacing conventional diffraction grating) |
| Polarization | Linear, PER ≥ 100:1 |
| Beam Dimensions | ~0.6 mm × 0.3 mm (elliptical, diode-dependent) |
| Scan Speed | Up to 15 GHz/s (with MOGLabs controller) |
| Modulation Bandwidth | 10 MHz (AC/DC coupling), RF bias-T option up to >2.5 GHz |
| Coarse Tuning Range | e.g., 776–802 nm or 850–895 nm (single-mode, diode-dependent) |
| Optional Accessories | Fiber coupling module, external optical isolator |
| Brand | CEL (China Education Goldsource) |
|---|---|
| Model | CEL-IS151 |
| Focal Length | 150 mm |
| f-number | f/4.5 |
| Stray Light | ≤5×10⁻⁴ |
| Minimum Wavelength Step | 0.0045 nm |
| Grating Dimensions | 30 mm × 30 mm |
| Standard Gratings | 7OG1200-300 (1200 grooves/mm, λₚ = 300 nm) & 7OG600-1000 (600 grooves/mm, λₚ = 1000 nm) |
| Slit Width Range | 10 μm – 3 mm (motorized, 10 μm knife-edge protected) |
| Slit Height | 5 mm |
| Housing Dimensions | 298 mm × 200 mm × 185 mm |
| Optical Center Height | 140 mm (±5 mm adjustable) |
| Weight | 10 kg |
| Filter Wheel | 6-position, motorized, Φ18 mm × 2 mm capacity, auto-zeroing on activation |
| Optical Layout | Exit and entrance ports orthogonal |
| Brand | CEL (China Education Goldsource) |
|---|---|
| Model | CEL-IS302 |
| Focal Length | 300 mm |
| f-number | f/4.8 |
| Stray Light | ≤5×10⁻⁴ |
| Minimum Step Resolution | 0.0023 nm |
| Grating Dimensions | 55 mm × 55 mm × 6 mm |
| Standard Grating Set | 1200 g/mm (λₚ = 300 nm), 600 g/mm (λₚ = 750 nm), 300 g/mm (λₚ = 1250 nm) |
| Slit Width Range | 10 μm – 3 mm (motorized, 10 μm knife-edge with auto-protection) |
| Slit Height | 14 mm |
| Dimensions (L×W×H) | 390 mm × 278 mm × 204 mm |
| Weight | 16 kg |
| Brand | CEO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | CW RBAT, QCW RBAT, CW REA, QCW REA |
| Key Components | Diode-Pumped Solid-State (DPSS) Laser Gain Modules |
| Gain Media Options | Nd:YAG, Nd:YLF |
| Operating Modes | Continuous Wave (CW), Quasi-Continuous Wave (QCW) |
| CW Output Power Range | 10–650 W |
| QCW Single-Pulse Energy Range | 150 mJ – >7.5 J |
| Rod Diameters | 2–25 mm |
| Rod Materials | Nd:YAG (standard), Nd:YLF (select models) |
| Thermal Management | Water-Cooled |
| Compliance | Designed for ISO 9001-aligned manufacturing and GLP-compliant laser system integration |
| Brand | CEO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Models | HSL Series, Patara Series, Gigashot Series |
| Key Components | Diode-Pumped Solid-State (DPSS) Lasers with Integrated Diode Drivers and Controllers |
| Wavelengths | 355 nm, 532 nm, 1064 nm, 527 nm, 1053 nm |
| Pulse Energy Range | 0.2 mJ to >2 J |
| Average Power Range | 2 W to 400 W |
| Repetition Rate | Single-shot to 50 kHz |
| Pulse Width (FWHM) | <1.5 ns to <250 ns |
| Beam Quality (M²) | <1.3 (TEM₀₀) to <5 (multi-mode) |
| Cooling | Air-cooled or water-cooled |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | AR2008 |
| Product Type | Benchtop Refractometer |
| Display | Digital LCD |
| Temperature Compensation | Optional integrated thermoelectric module |
| Measurement Range | 1.3000–1.7200 nD |
| Accuracy | ±0.0002 nD |
| Resolution | 0.0001 nD |
| Temperature Sensor Range | 0–99 °C |
| Temperature Accuracy | ±0.3 °C |
| Illumination Source | LED (589 nm) |
| Interface | RS-232 @ 9600 baud |
| Dimensions | 12.0 × 29.0 × 25.0 cm |
| Weight | 5 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | AR4 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | No |
| Measurement Range | 1.3000–1.7200 nD |
| Accuracy | ±0.0002 nD |
| Scale Division | 0.0005 nD |
| Temperature Sensor Range | 0–99 °C |
| Light Source | 590 nm LED (Sodium-D Equivalent) |
| Readout Method | Eyepiece with Graduated Scale Window |
| Dimensions | 10.0 × 27.0 × 19.0 cm |
| Weight | 2.5 kg |
| Calibration Standard | ASTM D1218 Compliant Calibration Plate |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DR101-60 / DR201-95 / DR301-95 |
| Sample Measurement Range | nD 1.3330–1.4419 (DR101-60), nD 1.3330–1.5318 (DR201-95 & DR301-95) |
| Brix Range | 0–60% (DR101-60), 0–95% (DR201-95 & DR301-95) |
| Refractive Index Accuracy | ±0.00015 nD (DR301-95), ±0.0003 nD (DR201-95), ±0.0005 nD (DR101-60) |
| Brix Accuracy | ±0.1% (DR301-95), ±0.2% (DR201-95), ±0.35% (DR101-60) |
| Resolution | 0.0001 nD / 0.1% Brix |
| Temperature Compensation Range | 10–40 °C (all models) |
| Temperature Sensor | Integrated PT100 |
| Light Source | LED at 589 nm (sodium D-line equivalent) |
| IP Rating | IP50 (DR101-60), IP64 (DR201-95), IP65 (DR301-95) |
| Power Supply | 9 V battery with AC adapter (DR301-95), 1.5 V battery (DR201-95 & DR101-60) |
| Dimensions (L×W×H) | 18.0×10.0×6.0 cm (DR301-95), 13.0×8.0×4.0 cm (DR201-95), 11.0×6.2×3.2 cm (DR101-60) |
| Weight | 500 g (DR301-95), 200 g (DR201-95), 160 g (DR101-60) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DR6000 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based (10–80 °C, ±0.1 °C accuracy, ±0.05 °C stability) |
| Display | 5.7″ color touchscreen |
| Measurement Range | nD 1.3300–1.7000 |
| Brix | 0–95 % |
| Resolution | nD 0.00001, Brix 0.01 % |
| Accuracy | nD ±0.00002, Brix ±0.02 % |
| Measurement Time | ~4 s |
| Prism | Sapphire |
| Light Source | LED (590 nm, >100,000 h lifetime) |
| Data Storage | Integrated SQL database (99 custom methods, 999 results with timestamp, operator ID, audit trail) |
| Compliance | GLP/GMP, FDA 21 CFR Part 11, USP/EP/JP/BP, ISO, ASTM, ICUMSA, OIML, HACCP, NIST-traceable calibration |
| Interfaces | USB, RS-232, Ethernet (LIMS/remote diagnostics) |
| Enclosure | Powder-coated metal, IP65 |
| Dimensions | 21.5 × 15 × 34.5 cm |
| Weight | 5 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | FP8400 |
| Type | Manual Flame Photometer |
| Detection Range | Na: 0.01–4500 mg/L (0.0004–200 mmol/L) |
| K | 0.02–4500 mg/L (0.0005–110 mmol/L) |
| Li | 0.02–3000 mg/L (0.0028–420 mmol/L) |
| Ca | 0.30–3000 mg/L (0.0075–75 mmol/L) |
| Measurement Channels | 5 independent configurable channels |
| Throughput | up to 300 samples/hour |
| Data Storage | 999 measurement records with traceable metadata |
| Compliance | GLP, GMP, FDA 21 CFR Part 11 (audit trail enabled) |
| Display | TFT high-brightness touchscreen |
| User Management | Dual-level authentication (admin/operator) |
| Interfaces | RS-232, USB, Ethernet |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | P3000 |
| Product Type | Automatic Polarimeter |
| Temperature Control | None (field-upgradable) |
| Display | Digital LCD Touchscreen |
| Light Source | LED (589 nm) |
| Measurement Range | ±90°, ±259 °Z |
| Resolution | 0.01° / 0.01 °Z |
| Repeatability | ±0.01° |
| Measurement Time | 1 s |
| Wavelength | 589 nm (fixed) |
| Path Length Compatibility | up to 220 mm |
| Data Storage | 999 entries |
| Interface | RS232 |
| Sensitivity | 0.1% w/w (at OD 3) |
| Calibration | Internal Auto-Calibration |
| Compliance | USP <781>, Ph. Eur. 2.2.7, BP Appendix XVII, JP XVI, ISO 8536-5, ASTM E1254, ICUMSA Method GS4/3-12, OIML R 136, NIST-traceable operation |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | P8000 |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (Peltier or external water bath) |
| Display | 5.7" color LCD touchscreen (640×480 px) |
| Light Source | LED (589 nm, optional wavelengths available) |
| Measurement Range | ±90°, ±259°Z, 0–99.9 g/100 mL |
| Accuracy | ±0.003°, ±0.01 °Z, ±0.5 g/100 mL |
| Repeatability | ±0.002° |
| Measurement Time | 1 s |
| Temperature Range | 0–99.9 °C (Peltier) |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Data Storage | 999 measurements |
| Interfaces | RS232, USB, Ethernet (LIMS-ready) |
| Sample Cell Options | 0.55–17 mL volume, 10–220 mm path length |
| Sensitivity | ≥0.1% (OD 3) |
| Calibration | Fully automated via menu |
| Compliance | ASTM E1258, ISO 11791, Ph. Eur. 2.2.7, USP <781>, OIML R163, IUCMSA, FDA 21 CFR Part 11, GLP/GMP audit trail capable |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PR21S / PR21S-T |
| Sample Compatibility | Liquid process streams in pipes or reactors |
| Temperature Range | 10–60 °C (PR21S), 10–120 °C (PR21S-T) |
| Refractive Index Range | nD 1.3200–1.5200 |
| Brix Range | 0–95 % |
| Accuracy | ±0.0002 nD, ±0.2 % Brix |
| Resolution | 0.0001 nD, 0.1 % Brix |
| Wavelength | 590 nm (LED source, >100,000 h lifetime) |
| Prism Material | Sapphire |
| Temperature Sensor | PT100 (range: 10–200 °C |
| accuracy | ±0.2 °C |
| resolution | 0.1 °C) |
| Output Signals | 4–20 mA analog, RS-232, optional PROFIBUS-DP |
| Enclosure Rating | IP65 |
| Dimensions | 18.0 × 19.0 × 18.0 cm |
| Weight | 3.5 kg |
| Temperature Compensation | ICUMSA-compliant or user-definable |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PRB21S |
| Product Type | Benchtop Bypass Refractometer |
| Temperature Control | Yes |
| Digital Display | No |
| Temperature Measurement Range | −10 to 99.9 °C |
| Temperature Accuracy | ±0.2 °C |
| Refractive Index Range (nD) | 1.3200–1.5600 |
| Brix Range | 0–95 % |
| Refractive Index Accuracy | ±0.0002 |
| Brix Accuracy | ±0.2 % |
| Refractive Index Resolution | 0.0001 |
| Brix Resolution | 0.1 % |
| Measurement Time | 3–60 s |
| Temperature Sensor | PT100 |
| Temp. Measurement Range | 10–120 °C |
| Temp. Resolution | 0.1 °C |
| Light Source | LED @ 590 nm (Lifespan > 100,000 h) |
| Output Signals | 0/4–20 mA analog, RS-232, optional PROFIBUS |
| IP Rating | IP65 |
| Dimensions (W×H×D) | 18.0 × 19.0 × 18.0 cm |
| Weight | 3 kg |
| Temperature Compensation | ICUMSA or user-definable |
| Brand | CHNSpec |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CT-23 / CT-25 |
| Product Type | Automatic Portable Meter |
| Transmittance Range | 0–100% |
| Transmittance Repeatability | ±2% |
| Spectral Channels | UV (365 nm), Visible (380–760 nm, CIE photopic luminosity function), IR (940 nm & 1400 nm) |
| Sample Thickness Capacity | ≤13 mm |
| Measurement Time | <1 s |
| Display | 1.14″ full-color TFT (135 × 240 px) |
| Power | Rechargeable 750 mAh Li-ion battery (USB charging) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Dimensions | 115 × 70 × 14 mm |
| Compliance | CE-marked design principles |
| Brand | Chotest |
|---|---|
| Model | W402 |
| Light Source | White LED |
| Imaging Sensor | 1024 × 1024 pixels |
| Standard Objective | 10× (optional: 2.5×, 5×, 20×, 50×, 100×) |
| Zoom Lens | 0.5× standard (optional: 0.375×, 0.75×, 1×) |
| FOV (10×) | 0.98 × 0.98 mm |
| XY Stage | 140 × 100 mm travel, 320 × 200 mm footprint, 10 kg load capacity |
| Z Focus Range | 100 mm motorized |
| Vertical Resolution | ≤ 0.1 nm (environmental noise evaluation mode) |
| Surface Reflectivity Range | 0.05% – 100% |
| Dimensions (H×W×D) | 900 × 700 × 600 mm |
| Vibration Isolation | Active air-bearing optical table base |
| Brand | Chotest |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | W412 |
| Price | USD 135,000 (FOB Guangdong) |
| Brand | Chroma |
|---|---|
| Origin | Taiwan |
| Model | CS-150 / CS-160 |
| Luminance Range | 0.0001–999,900 cd/m² (CS-150), 0.0001–9,999,000 cd/m² (CS-160) |
| V(λ) Photopic Luminous Efficiency Match | Improved vs. CS-100A |
| Measurement Method | Non-contact, Single-point Spectral Radiance Integration |
| Optical System | SLR-type with Eyepiece Viewfinder and External LCD Display |
| Minimum Measurable Spot Diameter | 0.4 mm (with optional macro lens, CS-160 only) |
| Power Supply | Rechargeable Battery |
| Brand | Chromacity |
|---|---|
| Origin | United Kingdom |
| Model | Spark FIR |
| Wavelength Range | 5–12 µm |
| Output Power | 75 mW @ 5–7 µm, 10 mW @ 12 µm |
| Pump Source | Spark 1040 |
| Pump Wavelength | 1040 nm |
| Repetition Rate | 100 MHz |
| Cooling Method | Air-cooled |
| Laser Head Dimensions | 970 × 245 × 82 mm |
| Controller Dimensions | 483 × 285 × 86 mm |
| Laser Head Weight | 18 kg |
| Controller Weight | 2 kg |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Interface | Ethernet |
| Compliance | CE, RoHS, IEC 61000-6-3/6-4 |
| Optional Output | Residual Pump Beam (1040 nm) |