| Brand | Duma Optronics |
|---|---|
| Origin | Israel |
| Model | EAC-HR |
| Aperture Diameter | 62 mm |
| Angular Resolution | 0.01 arcsec (0.1 µrad) |
| Field of View | 20′ (H) / 40′ (H) |
| Accuracy | ±1.0 arcsec |
| CCD Sensor | 1/2″ (1/3″ optional) |
| Light Source | 638 nm LED (Class 2, IEC 60825-1) |
| Focus Range | 30 cm to ∞ with boresight retention ±5 arcsec |
| Objective Thread | M67×0.75 mm |
| Collimation Mirror | Ø64 mm, mass 280 g, mounting thread Ø16 mm |
| Interface | USB 2.0, RS232, TCP/IP |
| Operating System | Windows 7 (32/64-bit) |
| Software | Native GUI + ActiveX SDK for integration |
| Brand | TOP (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GY-6 |
| Power Rating | 200 W |
| Spectral Output | Intense UV and Visible Continuum + Characteristic Mercury Emission Lines (e.g., 253.7 nm, 365 nm, 404.7 nm, 435.8 nm, 546.1 nm, 577–579 nm) |
| Lamp Geometry | Spherical Arc Tube |
| Operating Position | Universal (Horizontal/Vertical) |
| Rated Lifetime | ≥1,000 hours (at rated power, with proper cooling) |
| Cooling Requirement | Forced-air or water-cooled fixture recommended |
| Brand | HighFinesse |
|---|---|
| Origin | Germany |
| Model | LSA |
| Wavelength Range | 350–1100 nm (standard), 200–1100 nm (UV option) |
| Measurement Accuracy | ±5 pm @ 633 nm |
| Sensitivity | 5 nJ @ 633 nm |
| Maximum Spectral Range in High-Resolution Mode | λ/30 |
| Spectral Finesse | 30,000 (single-mode fiber), 15,000 (50 µm multimode fiber) |
| First-Order Calibration Accuracy | ±1 nm |
| Relative Linewidth Measurement Accuracy | ±5 × 10⁻⁶ (single-mode fiber) |
| Repetition Rate | up to 100 Hz |
| Light Source Compatibility | CW and pulsed lasers, gas ion lamps, superluminescent diodes (SLDs), laser diodes (LDs), and light-emitting diodes (LEDs) |
| Brand | HighFinesse |
|---|---|
| Origin | Germany |
| Model | WS8 |
| Spectral Range | 192–11,000 nm |
| Absolute Accuracy | ≤2 MHz (typ. @ 420–1100 nm) |
| Resolution | ≤200 kHz |
| Max. Measurement Rate | 76 kHz |
| Calibration | Internal (UV–VIS–IR), External (IR-III) |
| Operating Principle | Non-scanning Fizeau interferometer with passive thermal/pressure compensation |
| Brand | Hinds Instruments |
|---|---|
| Origin | USA |
| Model | 150AT |
| Retardation Range | 0.005–120+ nm (standard), up to 300+ nm (optional) |
| Retardation Resolution / Repeatability | 0.001 nm / ±0.008 nm (high-precision option) or 0.01 nm / ±0.015 nm (wide-range option) |
| Angular Resolution / Repeatability | 0.01° / ±0.05° (standard) or ±0.07° (wide-range) |
| Measurement Speed | up to 100 points per second (pps), scan time dependent on XY stage parameters |
| Spot Size | 1–3 mm native |
| Light Source Wavelength | 632.8 nm (HeNe, standard) |
| Modulation Frequency | 50 kHz or 50/60 kHz (PEMLabs™ Photoelastic Modulator) |
| Demodulation Method | Signaloc™ Lock-in Amplifier or waveform capture card |
| Measurement Units | nm (retardation), ° (fast-axis angle) |
| Dimensions (H×W×D) | 910 × 415 × 700 mm |
| Compliance | Designed for ISO/IEC 17025-aligned laboratories |
| Brand | Hinds Instruments |
|---|---|
| Origin | USA |
| Model | PEM-1000 |
| Wavelength Range | 400–700 nm (expandable to 130 nm – 18 µm) |
| Stokes Parameter Accuracy | <1% |
| Stokes Parameter Sensitivity | 0.0001 |
| Measurement Rate | up to 100 complete Stokes vector sets per second (400 individual Stokes parameter values) |
| Detector Sensitivity | sub-pW optical power detection |
| Compliance | Designed for ISO/IEC 17025-aligned optical metrology labs |
| Brand | Hinds Instruments |
|---|---|
| Origin | USA |
| Model | DV-193 |
| Wavelength Range | 180–200 nm (optimized at 193 nm) |
| Measurement Principle | Dual-PEM Modulated Photoelastic Polarimetry |
| Stokes Parameter Acquisition Rate | >100 Hz |
| Accuracy (180–200 nm) | ±1% |
| Sensitivity | <0.0005 |
| Repeatability (3σ, 180–200 nm) | ≤0.01 |
| Repeatability (3σ, 200–400 nm) | ≤0.0035 |
| PEM Resonant Frequency | 37–100 kHz |
| Compliance | ASTM E284, ISO 15382, USP <857>, GLP/GMP-ready data audit trail |
| Brand | Hinds Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PolSNAP |
| Pricing | Available Upon Request |
| Sampling Rate | 2000 samples/s |
| Stokes Parameter Accuracy | <1% |
| Repeatability | ±0.06% |
| Form Factor | Handheld (≤120 × 85 × 45 mm) |
| Interface | USB 3.0 |
| Spectral Range | 400–1100 nm (standard broadband configuration) |
| Output | Full 4-element Stokes vector (S₀, S₁, S₂, S₃) in real time |
| Brand | HJ |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LX1010B |
| Sensor Type | Silicon Photodiode with V(λ)-matched Optical Filter |
| Display | 3½-digit LCD (max. 1999 counts) |
| Accuracy | ±4% rdg ±0.5% f.s. (±5% rdg ±10 digits for >10,000 Lux range, calibrated against 2856 K standard tungsten lamp) |
| Ranges | 2000 Lux / 20,000 Lux (×10 multiplier) / 100,000 Lux (×100 multiplier) |
| Resolution | 1 Lux (on 2000 Lux range) |
| Repeatability | ±2% |
| Temperature Coefficient | ±0.1% / °C |
| Sampling Rate | 2 samples/sec |
| Hold Function | Yes |
| Photodetector | V(λ)-corrected silicon photodiode with diffuser and spectral filter |
| Dimensions (Sensor Head) | 106 × 57 × 26 mm |
| Dimensions (Main Unit) | 130 × 72 × 30 mm |
| Brand | HongKe |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HK-BOS Reflecting Objective |
| Magnification | 15× |
| Numerical Aperture | 0.28 |
| Working Distance | 190 mm |
| Clear Aperture | 120 mm |
| Optical Design | All-Reflective, Achromatic |
| Coating Options | Customizable Broadband Metallic (e.g., Al+MgF₂, Protected Au, or Enhanced Ag) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Holo/Or |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Core Application Domain | Solid-State Laser Systems & Precision Laser Processing |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DPE |
| Price Range | USD 6,800 – 13,600 (FOB Hamburg) |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | GAEA-2-NIR |
| Wavelength Range | 650–1100 nm |
| Active Area | 0.7" (15.32 × 8.97 mm) |
| Resolution | 4160 × 2464 pixels |
| Pixel Pitch | 3.74 µm |
| Fill Factor | 90% |
| Reflectivity | 72% |
| Maximum Spatial Frequency | 133.5 lp/mm |
| Gray Levels | 8-bit (256 levels) |
| Interface | HDMI |
| Frame Rate | 24 Hz @ full resolution (4160 × 2464), 30 Hz @ 3840 × 2160 |
| Phase Modulation Type | Pure-phase, nematic liquid crystal on silicon (LCoS) |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | GAEA-2-TELCO |
| Wavelength Range | 1400–1700 nm |
| Active Area | 0.7" (15.32 × 8.97 mm) |
| Resolution | 4094 × 2464 pixels |
| Pixel Pitch | 3.74 µm |
| Fill Factor | 90% |
| Maximum Phase Modulation | 2.4π @ 1550 nm |
| Reflectivity | 72% |
| Maximum Spatial Frequency | 133.5 lp/mm |
| Grayscale Depth | 8-bit (256 levels) |
| Interface | HDMI |
| Frame Rate | 24 Hz (full resolution), 30 Hz (3840 × 2160 subsampled) |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | GAEA-2-VIS |
| Wavelength Range | 420–650 nm |
| Active Area | 15.32 × 8.97 mm (0.7″) |
| Resolution | 4094 × 2464 pixels |
| Pixel Pitch | 3.74 µm |
| Fill Factor | 90% |
| Maximum Phase Modulation | 3π @ 532 nm |
| Reflectivity | 62% |
| Spatial Resolution (Nyquist) | 133.5 lp/mm |
| Grayscale Depth | 8-bit (256 levels) |
| Interface | HDMI |
| Frame Rate | 24 Hz (full resolution), 30 Hz (3840 × 2160) |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | LETO Pure-Phase |
| Modulation Type | Pure Phase |
| Liquid Crystal Type | Reflective LCoS |
| Resolution | 1920 × 1080 |
| Pixel Pitch | 6.4 µm |
| Active Area | 12.29 mm × 6.91 mm |
| Phase Range | 6.2π @ 405 nm, 1.6π @ 1064 nm |
| Dynamic Range | >1000:1 (typ.) |
| Fill Factor | 93% |
| Frame Rate | 60 Hz |
| Response Time (VIS) | ~25 ms |
| Diffraction Efficiency | 75% |
| Max. Optical Power Density | 2 W/cm² |
| Spectral Range | 400–1100 nm |
| Interface | HDMI / DVI |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | Luna |
| Pixel Resolution | 1920 × 1080 |
| Pixel Pitch | 4.5 µm |
| Active Area | 8.64 × 4.86 mm |
| Wavelength Range | 400–1700 nm (visible & telecom bands) |
| Interface | DisplayPort + USB 2.0 |
| Power Consumption | <2.5 W |
| Operating Mode | Hot-pluggable, phase-only modulation via 8-bit grayscale green-channel input |
| Onboard Processing | Integrated ASIC for real-time pattern preprocessing |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | PLUTO-2.1-UV-099 |
| Pixel Resolution | 1920 × 1080 |
| Pixel Pitch | 8 µm |
| Wavelength Range | UV-optimized (typically 355–405 nm) |
| Interface | USB-controlled gamma/dynamic range calibration |
| Video Input | Standard HDMI/VGA via GPU extended display (Green channel, 8-bit grayscale) |
| Operating Mode | Pure-phase modulation only |
| Compliance | CE-marked, RoHS-compliant |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | PLUTO-VIS |
| Modulation Type | Pure Phase |
| Liquid Crystal Type | Reflective |
| Gray Levels | 8-bit (256 levels) |
| Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 8.0 µm |
| Active Area | 15.36 mm × 8.64 mm |
| Phase Range | 2π @ 532 nm |
| Frame Rate | 60 Hz |
| Response Time (VIS) | ~25 ms |
| Diffraction Efficiency | 60% |
| Maximum Optical Power Density | 2 W/cm² |
| Spectral Range | 400–1100 nm |
| Interface | DVI or HDMI |
| Brand | TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | XGS-7A |
| Pricing | Upon Request |
| Brand | Honle |
|---|---|
| Origin | Germany |
| Model | UV METER |
| Detection Channels | Dual-channel (simultaneous UVA/UVB/UVC/VIS/LED) |
| Spectral Ranges | UVA (340–410 nm), UVB (260–330 nm), UVC (230–285 nm), VIS (360–550 nm), LED (310–485 nm) |
| Max Irradiance | UVA 20 W/cm² (quartz rod sensor), UVB 2 W/cm², UVC 2 W/cm², VIS 10 W/cm², LED 30 W/cm² |
| Sensor Types | Miniature photodiode sensor, fiber-optic probe, quartz rod probe |
| Data Storage | High-capacity internal memory |
| Interface | USB (for data export, PLC/PC integration, and Li-ion battery charging) |
| Power | Rechargeable lithium-ion battery with extended cycle life |
| Auto-start Trigger | Activates measurement upon irradiance exceeding user-defined threshold |
| Keypad | Ergonomic membrane keyboard with dedicated function keys |
| Compliance | Designed for industrial UV curing process validation per ISO 11664, CIE S 017/E:2020, and ASTM E2914-13 |
| Brand | Hopocolor |
|---|---|
| Model | HPALTS-800 |
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic |
| Price | USD 27,500 (FOB) |
| Luminous Intensity Range | 0.1–100,000 cd |
| Luminous Intensity Accuracy | ≤±2% (under standard conditions) |
| Angular Resolution | 0.1° |
| Angular Repeatability | <0.1° |
| Cumulative Angular Error | <0.2° |
| Horizontal Rotation Range | −180° to +180° |
| Vertical Rotation Range | −90° to +90° |
| Horizontal Scan Speed | 0.5 / 1 / 2 °/s |
| Vertical Scan Speed | 0.5 / 1 / 2 °/s |
| Centering Alignment Accuracy | <0.1° (calibratable to <0.05°) |
| Ambient Light Rejection | Enabled |
| Test Distance | ≤10 m (1 m for edge lights) |
| Compliance | ICAO Annex 14, FAA AC 150/5340-30H, FAA Order 8260.19D |
| Power Output | 350 W |
| Current Measurement Accuracy | <±0.1 A |
| Current Stability | <3% |
| Input Voltage | 110–230 VAC |
| Max Load Capacity | 18 kg |
| Report Generation | Automated, GLP-compliant PDF/CSV export |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Auto SE |
| Spectral Range | 450–1000 nm |
| Incident Angle | 70° fixed |
| Detector | CCD array |
| Spot Size Options | 8 discrete sizes (automatically selectable) |
| Sample Stage | Motorized XYZ stage (200 mm × 200 mm travel, Z > 35 mm) |
| Optical Architecture | Liquid crystal phase modulation (no moving parts in measurement path) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HU-200TB |
| Type | Online Turbidimeter |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU |
| Operating Ambient Temperature | ±25 °C |
| Accuracy | ±1% of reading |
| Optical Configuration | Quadruple-light-path detection system |
| Compliance | Designed for continuous process monitoring in water treatment and environmental applications |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-320 |
| Measurement Angle | 60° |
| Measurement Range | 0–100 GU |
| Resolution | 0.1 GU |
| Accuracy | ±0.5% F.S. ±1 digit |
| Spot Size | 16 mm × 12 mm |
| Display | LED numeric |
| Power Supply | 9 V DC battery (1 pc) |
| Dimensions (W×H×D) | 78 × 189 × 58 mm |
| Calibration | Automatic self-calibration with reference standard recognition |
| Detector Design | Detachable sensor head |
| Data Memory | Stores up to 99 measurement points with statistical analysis (mean, standard deviation) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-320 |
| Measurement Angle | 60° |
| Gloss Range | 0–100 GU |
| Resolution | 0.1 GU |
| Accuracy | ±0.5% F.S. ±1 digit |
| Spot Size | 16 × 12 mm |
| Repeatability (Haze) | 0.2% |
| Repeatability (Transmittance) | 0.5% |
| Haze Range | 0–30% |
| Transmittance Range | 0–100% |
| Power Supply | 9 V DC battery |
| Dimensions (W × H × D) | 78 × 189 × 58 mm |
| Display | LED digital |
| Calibration | Auto-calibration with detachable sensor head |
| Data Memory | Stores up to 99 readings with statistical functions (mean, standard deviation) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-331 |
| Measurement Angle | 60° |
| Measurement Range | 0–100 GU |
| Resolution | 1 GU |
| Accuracy | ±5% F.S. ±1 digit |
| Spot Size | 16 mm × 12 mm |
| Display | LED numeric |
| Power Supply | 9 V DC battery (1 pc) |
| Dimensions (W×H×D) | 78 × 189 × 58 mm |
| Calibration | Auto-recognition calibration system |
| Data Memory | Up to 99 measurement points with statistical functions (mean, mean deviation) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-331 |
| Measurement Angle | 60° |
| Measurement Range | 0–100 GU |
| Resolution | 1 GU |
| Accuracy | ±5% F.S. ±1 digit |
| Spot Size | 16 × 12 mm |
| Display | LED digital |
| Power Supply | 9 V DC battery (1 pc) |
| Dimensions (W × H × D) | 78 × 189 × 58 mm |
| Calibration | Auto-calibration with reference standard recognition |
| Detector Design | Separated sensor head for flexible positioning |
| Data Memory | Stores up to 99 readings with statistical functions (mean, mean deviation) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IG-331 |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-340 |
| Type | Automatic Portable Gloss Meter |
| Gloss Range | 0.0–100.0 GU (60° geometry) |
| Display Range | 0.0–199.9 GU (OVER indication above 100.0) |
| Repeatability | ±0.6 GU (±0.5% of full scale ±1 digit) |
| Measurement Area | 6 × 12 mm elliptical spot |
| Measurement Angle | 60° |
| Light Source | LED (880 nm) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 35–85% RH (non-condensing) |
| Ingress Protection | IP42 |
| Power Supply | 2 × AA batteries |
| Dimensions | 61 × 62 × 176 mm |
| Weight | ≤320 g (including batteries and protective cap) |
| Memory Capacity | 100 single readings + 200 averaged datasets (with timestamp) |
| Data Interface | USB (Windows 10 compatible, bulk export supported) |
| Accessories | Calibration standard plate integrated in protective cap, soft carrying case, lens cleaning cloth |