Optical Measurement Instruments
Filter
Showing 1621–1650 of 3895 results
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Auto SE |
| Spectral Range | 450–1000 nm |
| Incident Angle | 70° |
| Sample Stage | Motorized XYZ Translation (200 mm × 200 mm travel, Z-height > 35 mm) |
| Detection | CCD-based Full-Spectrum Acquisition |
| Optical Architecture | Liquid-Crystal Variable Retarder (LCVR) Modulation, No Moving Parts in Measurement Path |
| Spot Visualization | Integrated Real-Time Imaging System |
| Compliance | Designed for ISO/IEC 17025-aligned QC environments, supports audit-ready data logging per GLP/GMP principles |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | UVISEL 2 |
| Spectral Range | 190–2100 nm |
| Minimum Spot Size | 35 × 85 µm |
| Sample Stage | 200 mm × 200 mm with Motorized XYZ Translation and Auto-Leveling |
| Incidence Angle Range | 35°–90° (Auto-Adjustable, 0.01° Minimum Step) |
| Detector Configuration | Three Independent Detectors (UV-Optimized, VIS-Optimized, NIR-Optimized) |
| Optical Architecture | Dual-Grating Spectrometer with High Stray-Light Suppression |
| Modulation Technology | 50 kHz Photoelastic Modulator (PEM) |
| Imaging Capability | Integrated Visible Microscope with Real-Time Spot Visualization |
| Beam Delivery | Fixed-Path, No Moving Elements in Measurement Light Path |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | In-situ Series |
| Application | In-line thin-film process monitoring during deposition and etching |
| Measurement Principle | Spectroscopic ellipsometry (SE) |
| Optical Configuration | Fiber-coupled, modular probe head design for integration into vacuum chambers or CVD/PVD/ALD tools |
| Spectral Range | Typically 190–1700 nm (configurable per system variant) |
| Spot Size | Adjustable, down to ~50 µm (dependent on optical interface and working distance) |
| Angle of Incidence | Fixed or motorized, commonly 65°–75° (customizable per integration requirement) |
| Measurement Speed | Up to 10 Hz spectral acquisition (full spectrum), sub-second single-wavelength monitoring |
| Single-Measurement Time | <100 ms (at fixed wavelength) |
| Sample Compatibility | Wafers up to 300 mm, flat or curved substrates, high-temperature or cryogenic environments (with optional thermal management) |
| Thickness Accuracy | ±0.1 nm (for SiO₂ on Si reference films, under controlled conditions) |
| Repeatability | <0.05 nm RMS over 24 h (thermal drift compensated) |
| n/k Determination Uncertainty | Δn < 0.002, Δk < 0.0005 (for transparent dielectrics) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Product Type | Portable |
| Measurement Range | 0–2000 NTU |
| Resolution | 0.01 NTU (0.00–19.99 NTU), 0.1 NTU (20.0–199.9 NTU), 1 NTU (200–2000 NTU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.02 NTU or ±2% (0.00–1000 NTU) |
| Calibration Points | Up to 4 (0.02, 20, 100, 800 NTU) |
| IP Rating | IP67 |
| Display | Backlit monochrome LCD |
| Data Storage | 2000 measurements with timestamp |
| Light Source | 860 nm infrared LED |
| Detector | Silicon photodiode |
| Sample Volume | 10 mL |
| Power | 4×AA batteries |
| Dimensions | 210 × 110 × 55 mm |
| Weight | 510 g (with batteries), 410 g (without) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Smart SE |
| Spectral Range | 450–1000 nm |
| Spot Size Options | Multiple Micro-Spot Sizes with Real-Time Visual Observation |
| Incidence Angle | Variable (Motorized Multi-Angle Capability) |
| Measurement Speed | Full-Spectrum Acquisition in <1 Second |
| Single-Measurement Time | <2 s (Typical, Including Stage Positioning) |
| Sample Stage | Motorized XYZ Translation (200 mm × 200 mm Travel, Z-Travel >35 mm) |
| Detector | CCD-Based Spectral Analyzer |
| Modulation Technology | Liquid Crystal Variable Retarder (LCVR), No Moving Parts in Optical Path |
| Configuration Flexibility | Supports Both In-Line Process Integration and Stand-Alone Lab Use |
| Compliance | Designed for ISO/IEC 17025-Compatible Metrology Environments |
| Software | HORIBA DeltaPsi² Platform with Audit Trail, User Access Control, and Exportable Raw Data (CSV, XML, HDF5) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Smart SE |
| Spectral Range | 450–1000 nm |
| Detector | CCD |
| Spot Visualization | Patented real-time surface imaging |
| Spot Selection | Motorized multi-size micro-spot (e.g., 30 µm, 100 µm, 300 µm) |
| Sample Stage | Motorized XYZ stage (200 mm × 200 mm travel, Z-axis range >35 mm) |
| Modulation | Liquid Crystal Variable Retarder (LCVR), no moving parts in optical path |
| Measurement Mode | Variable-angle spectroscopic ellipsometry |
| Output | Full-spectrum Ψ(λ) and Δ(λ) in <1 s per angle |
| Configuration | Supports both offline lab-based and inline process-integrated deployment |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Smart SE |
| Measurement Speed | 5 s (typical), down to 1 s (max) |
| Wavelength Range | 450–1000 nm |
| Spot Sizes | 7 selectable configurations (e.g., 75 µm × 150 µm to 500 µm × 500 µm) |
| Software | DeltaPsi² v5.x (Windows-based) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | UVISEL |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HSR-3000 |
| Pricing | Available Upon Request |
| Brand | Hubner |
|---|---|
| Origin | Germany |
| Model | C-WAVE |
| Type | Continuous-wave Optical Parametric Oscillator (OPO)-based Tunable Laser Source |
| Spectral Range | 450–650 nm (visible, via SHG of idler/signal) + 900–1300 nm (NIR, intracavity signal/idler) |
| Linewidth | <100 kHz (C-WAVE advanced) |
| Tuning Mechanism | Motorized cavity length & nonlinear crystal angle control |
| Interface | GUI (Windows/Linux) and SCPI-compliant USB/Ethernet programming interface |
| Compliance | CE, RoHS, IEC 60825-1 Class 4 Laser Product |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Aeros Accessory Kit |
| Product Type | Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | LED Cold Light Source |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Aeros Biscuit Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED (Cool White) |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 (mean, CIE Lab, standard conditions) |
| Measurement Area | Up to 223.2 cm² (34.6 in²) |
| Sample Handling | Non-contact, Auto-height Detection, Motorized Rotating Sample Tray (35 measurements per rotation, 5 s/rotation) |
| Display | Full-color capacitive touchscreen interface |
| Software | EasyMatch ESSENTIAL (standalone operation supported) |
| Compliance | Designed for GLP/GMP environments |
| compliant with ISO 11664-4 (CIE colorimetry), ASTM E308, and CIE 15 | 2018 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Aeros Chip Colorimeter |
| Product Type | Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED (Cool White) |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 (mean, CIE Lab, 10 measurements on uniform tile) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Aeros Food Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED (Cool White) |
| Spectral Range | 400–700 nm |
| Repeatability | ≤0.03 ΔE* (CIE Lab, mean of 35 measurements) |
| Measurement Area | Up to 223.2 cm² (34.6 in²) |
| Interface | Capacitive Touchscreen Display |
| Software | EasyMatch ESSENTIAL (Standalone & PC-Connectable) |
| Connectivity | Ethernet, USB, Wi-Fi, Email Export, LIMS/SPC Integration, Remote Diagnostic Support (HunterLab Connect) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Aeros |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | In-Line / Benchtop Hybrid |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED (Cool White) |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 (mean, CIE Lab, standard illuminant D65, 10° observer) |
| Measurement Area | Up to 223.2 cm² (34.6 in²) per full rotation |
| Rotation Speed | 35 measurements in 5 seconds |
| Height Adjustment | Motorized Auto-Positioning via Precision Ultrasonic Sensor |
| Interface | 7″ Full-Color Capacitive Touchscreen |
| Software | EasyMatch ESSENTIAL (embedded & PC-compatible) |
| Compliance | Supports FDA 21 CFR Part 11 audit trail (with optional user management), GLP/GMP data integrity protocols, ASTM E308, ISO/CIE 11664-4, ISO 13655 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Aeros Non-Contact Spectrophotometer |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED (Cold White) |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 (mean, CIE Lab, standard tile) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Aeros |
| Instrument Type | Benchtop |
| Light Source | Full-Spectrum LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | ∆E* < 0.025 CIE L*a*b* (max, 30 measurements on white tile) |
| Measurement Area | 177.25 cm² (φ15 cm) |
| Sample Height Range | 65 mm – 140 mm |
| Rotation Speed | 12 rpm |
| Measurement Time per Revolution | 5 s |
| Spectral Resolution | < 3 nm |
| Effective Bandwidth | 10 nm |
| Photometric Range | 0–150 % |
| Inter-Instrument Agreement | ∆E* < 0.30 CIE L*a*b* (avg, CCSII tile) |
| Data Storage Capacity | 500,000 measurements |
| Display | 7″ HD Touchscreen (1280 × 800) |
| Power Supply | 100–240 VAC, 47–63 Hz / 24 VDC (90 W) |
| Dimensions (L×W×H) | 38 × 51 × 56 cm |
| Weight | 23 kg |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Aeros |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Sample Measurement Area | 223.2 cm² (34.6 in²) |
| Measurement Method | Non-contact, Auto-height-adjusted Spectrophotometry |
| Rotation Platform | Motorized, 35 measurements per 5-second rotation |
| Display | High-resolution Full-color Touchscreen |
| Embedded Software | EasyMatch Essentials® |
| Remote Support | HunterLab Remote Access Support (RAS) |
| Compliance Ready | ASTM E308, ISO 11664, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (audit trail & user authentication enabled in software) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Aeros |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Tungsten Halogen Lamp |
| Spectral Range | 400–720 nm |
| Repeatability | ΔE*ab ≤ 0.06 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Aeros-ARS |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 (mean, CIE Lab) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Product Type | Spectrophotometric Color Measurement Accessory Kit |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Full-Spectrum Balanced LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Compliance | NIST-Traceable Calibration Standards, ASTM D523 / ISO 2813 Gloss Reference, Hohenstein-Traced UV Fluorescence Standard |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | AGR |
| Product Type | Benchtop Spectrophotometer |
| Instrument Category | Color Measurement Instrument |
| Optical Geometry | 0°/45° annular illumination (15-point fiber optic averaging) |
| Light Source | Full-spectrum LED (360–700 nm) with UV control |
| Spectral Range | 360–700 nm |
| Repeatability | ΔE₀₀ < 0.03 CIELAB (max) |
| Gloss Measurement | 60° geometry, compliant with ASTM D523, ISO 2813, ASTM D2457 |
| Image Capture | Integrated 5 MP camera at 45° |
| Display | 7″ 1280×800 industrial capacitive touchscreen |
| Software | Embedded EasyMatch Essentials QC software with optional 21 CFR Part 11 electronic signature |
| Calibration Standards | NIST-traceable white tile, green tile with certified values, black glass gloss standard (ASTM/ISO traceable) |
| Aperture Options | XL (51 mm), L (25.4 mm), M (16.9 mm), custom 30 mm |
| Power Supply | 100–240 VAC |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Agera Coating Colorimeter |
| Product Type | Color Difference Meter |
| Instrument Form Factor | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum Balanced LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Gloss Measurement | 60°, Compliant with ASTM D523 & ISO 2813 |
| Aperture Sizes | 50.8 mm (2"), 25.4 mm (1"), 15.89 mm (5/8") |
| UV Control | Adjustable UV Component (UV-included / UV-excluded modes with factory-calibrated UV reference) |
| Display | High-Resolution Capacitive Touchscreen |
| Onboard Imaging | 5 MP Camera with 45° Full-Spectrum Illumination |
| Data Export | USB Flash Drive Support |
| Connectivity | PC Software Integration (Universal Software Suite), Remote Diagnostic & Firmware Update Capability (via secure TLS-encrypted connection) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Agera |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere (with optional 0°/45° annular illumination) |
| Light Source | Xenon flash lamp |
| Spectral Range | 360–700 nm |
| Repeatability | ΔE*ab ≤ 0.23 |
| Aperture Sizes | XL, L, M (fixed contact mode) |
| Gloss Measurement | 60° geometry, compliant with ASTM D523 and ISO 2813 |
| Integrated Camera | 5 MP, 45° full-spectrum illumination |
| Display | 7″ capacitive touchscreen (1280 × 800 px) |
| Connectivity | USB, USB OTG, Ethernet, Wi-Fi, Bluetooth, email export |
| Software | Embedded EasyMatch Essentials QC software |
| Optional Compliance | FDA 21 CFR Part 11 electronic records & signatures module |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Agera |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Annular Illumination and Viewing |
| Spectral Range | 360–700 nm |
| Light Source | Full-Spectrum LED with Adjustable UV Output |
| Repeatability | <0.08 ΔE*ab (for white tile, 10 readings) |
| Aperture Options | XL (52 mm), L (30 mm), M (18 mm) |
| Gloss Measurement | 60° geometry, compliant with ASTM D523 and ISO 2813 |
| Imaging System | 5 MP camera with 45° uniform illumination |
| Display | 7″ capacitive touchscreen (1280 × 800 px) |
| Connectivity | Ethernet, Wi-Fi, Bluetooth, USB, USB OTG, Email export, LIMS/SPC integration |
| Software | Embedded EasyMatch ESSENTIAL (optional 21 CFR Part 11-compliant electronic records module) |
| Remote Support | HunterLab Remote Access enabled |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Agera |
| Product Type | Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere (with Optional 0°/45° Annular Illumination Module) |
| Light Source | Full-Spectrum Balanced LED Array with UV-Adjustable Output |
| Spectral Range | 400–700 nm (standard) |
| Repeatability | ΔE*ab ≤ 0.03 |
| Compliance | ASTM D2244, ASTM E308, ISO 7724, ISO 11664, CIE No. 15, GB/T 3978–2008 |
| Data Output | CIE L*a*b*, L*C*h*, YI (ASTM D1925 & E313), ΔE*ab, ΔE00, Gloss (60°), High-Resolution Sample Imaging |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Agera |
| Product Type | Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Full-Spectrum Balanced LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Gloss Measurement | 60°, compliant with ASTM D523 and ISO 2813 |
| Aperture Options | 50.8 mm (2"), 25.4 mm (1"), 15.89 mm (5/8") |
| UV Filter Function | Switchable UV-included / UV-excluded modes with factory-calibrated UV reference standards |
| Imaging System | Built-in 5 MP camera with 45° full-spectrum illumination |
| Display | High-resolution color touchscreen |
| Data Export | USB flash drive support |
| Connectivity | USB and Ethernet for PC integration via EasyMatch QC software |
| Remote Support Capability | Secure cloud-enabled diagnostics and firmware updates |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Inverted Measurement Stand |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum Balanced LED Array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | Agera L2 |
| Product Category | Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | LED |
| Spectral Range | 360–700 nm |
| Repeatability | ΔE* < 0.03 (CIE L*a*b* scale) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | Agera-L2 |
| Product Type | Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | 45/0° |
| Light Source | Full-spectrum balanced LED array |
| Spectral Range | 400 nm – 700 nm |
| Repeatability | ΔE* ≤ 0.03 |
| Measurement Aperture | Large-area (up to 16× standard) |
| Integrated Capabilities | Simultaneous color + 60° gloss measurement |
| Built-in Imaging | High-resolution sample alignment camera with image capture and metadata embedding |