| Brand | PULUODY |
|---|---|
| Model | PMT-2SD |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation |
| Measuring Range | 0.1–0.5 µm & 0.5–5.0 µm (customizable to 1–100 µm or 4–70 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Data Output | 4–20 mA analog interface,超标 alarm output (customizable) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen UI) |
| Display | Color LCD touch interface + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1/2, USP <788>, ISO 8573-4, and semiconductor-grade liquid purity monitoring workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2T |
| Price | USD 31,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Measurement Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Output Interface | 4–20 mA analog output with configurable alarm relay |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Operating Voltage | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PW (Yuelian) |
|---|---|
| Origin | Guangdong, China |
| Model | PW-TB320 |
| Coating Method | Wire-Bar (Standard ISO/GB Compliant, Optional Selection) |
| Coating Width | 300 × 420 mm |
| Travel Range (X-axis) | 300 × 420 mm |
| Coating Speed | Adjustable 1–5 m/min |
| Drive System | Infinitely Variable AC Motor |
| Control Interface | Dedicated Panel with Coating/Return/Stop/Speed Adjustment |
| Weighting System | Dual-Side Adjustable Counterweights |
| Wire-Bar Length | 400 mm |
| Power Supply | 110–220 V AC, 50/60 Hz |
| Rated Power | 120 W |
| Net Weight | 20 kg |
| Overall Dimensions | 710 × 420 × 285 mm (L×W×H) |
| Accuracy | Dependent on Wire-Bar Tolerance per ISO 2137 and GB/T 9278 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJ-DT Series |
| Load Capacity | 10,000 kN |
| Load Cell Accuracy | ±0.01% FS |
| Test Accuracy | ±0.5% of reading |
| Speed Range | 0.001–300 mm/min |
| Test Stroke | ≥200 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 600 × 300 × 300 mm |
| Weight | ~40 kg |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | QJCYX-542 |
| Price | USD 8,600 (FOB Shanghai) |
| Temperature Range | 0–60 °C |
| Humidity Range | 40–98% RH (at 30–60 °C) |
| Temp. Uniformity | ≤±2 °C |
| Temp. Stability | ≤±0.5 °C |
| Humidity Stability | +2/−3% RH |
| Heating Rate | 0.7–1.0 °C/min |
| Cooling Rate | ≤20 min (from ambient to 10 °C, uncontrolled ambient conditions) |
| Ozone Concentration Range | 10–1000 pphm |
| Gas Flow Velocity | 12–16 mm/s |
| Sample Mounting | Static Rack Only |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211 |
| Load Capacity | 30 kN (selectable) |
| Force Sensor Accuracy | 0.01% |
| Measurement Accuracy | < ±0.5% |
| Control System | Full PC-based Windows interface |
| Effective Test Width | ~420 mm |
| Effective Stroke | ~800 mm |
| Test Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% |
| Displacement Accuracy | ±0.5% |
| Strain Measurement Accuracy | ±0.5% |
| Safety Features | Electronic stroke limit protection, emergency stop button |
| Machine Weight | ~140 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJYL872 |
| Max. Compression Load | 300 kN |
| Max. Flexural Load | 10 kN |
| Load Accuracy | ±1% (FS) |
| Compression Loading Rate | 0–10 kN/s |
| Flexural Loading Rate | 0–0.075 kN/s |
| Compliance | GB/T 17671–1999, GB/T 50081–2002, GB 13544–2000 |
| Application Scope | Cement mortar, concrete cubes, fired bricks, ceramic tiles, masonry units, and structural precast elements |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJYS-70 |
| Price | USD 7,300 (approx.) |
| Internal Chamber Dimensions (Min) | 600 × 450 × 400 mm |
| Internal Chamber Dimensions (Max) | 1600 × 1000 × 500 mm |
| External Dimensions (Min) | 1075 × 630 × 1185 mm |
| External Dimensions (Max) | 2300 × 1200 × 1485 mm |
| Chamber Volume (Min) | 108 L |
| Chamber Volume (Max) | 800 L |
| Salt Solution Tank Capacity (Min) | 15 L |
| Salt Solution Tank Capacity (Max) | 40 L |
| Test Temperature Range | Up to 65 °C |
| Compliant Standards | GB/T 2423.17 (Neutral Salt Spray), ASTM B117, ISO 9227, JIS Z2241 |
| Brand | QJICHL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QJICHL2 |
| Price | USD 6,800 (FOB Shanghai) |
| Test Load Range | 3 N, 5 N, 7 N, 8 N (standardized weights supplied) |
| Cycle Count Range | 0–200 cycles (adjustable, programmable) |
| Cycling Frequency | 0.5 Hz ±0.02 Hz |
| Test Stations | 5 independent, simultaneously controlled and monitored |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (L×W×H) | 500 × 400 × 400 mm |
| Net Weight | 12 kg |
| Roller Height & Position | Manually adjustable initial height and lateral offset |
| Roller Support Structure | Dual-side support plates |
| Compliance | ISO/IEC 10373-3:2001 Annex D (Triple-Roller Mechanical Endurance Test for Contact IC Cards) |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LHQCM-2014 |
| Pricing | Available Upon Request |
| Brand | Hopebiol |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | GH-DLC01 |
| Price | Upon Request |
| Dimensions | 480 × 310 × 410 mm |
| Dispensing Speed | 3000 mL/min |
| Volume Range | 20–4000 mL |
| Power Supply | 220 V AC, 200 W |
| Net Weight | 12 kg |
| Control Interface | Capacitive Touchscreen |
| Operating Temperature | 5–40 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Dispensing Accuracy | ±1% |
| Dispensing Mechanism | Magnetic Drive Peristaltic-Free Pump |
| Brand | CME |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Classification | Domestic (China) |
| Model | Quartz Optical Fiber |
| Price | USD 265 (FOB Beijing) |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | R-6 |
| Pricing | Available Upon Request |
| Brand | Raykol |
|---|---|
| Model | DRQ A+B |
| Origin | Guangdong, China |
| Manufacturer | Raykol Group |
| Equipment Type | Automated QuEChERS Processing Platform |
| Sample Throughput | Up to 24 samples per run |
| Homogenization Bead Dispensing | Programmable by sample matrix |
| Liquid Handling Accuracy | ≤1% CV at 100–1000 µL |
| Liquid Level Detection | Capacitive + optical dual-mode |
| Spike Addition Module | Precision syringe-based, traceable volume delivery |
| Vortex Mixing | 0–3000 rpm, programmable duration and acceleration profile |
| Nitrogen Concentration | Vision-guided endpoint detection (meniscus recognition at 0.5 mL, 1.0 mL, or custom刻度) |
| Sample Cooling | Peltier-cooled vial chamber (4–12 °C adjustable) |
| Filtration | Auto-loaded 0.22 µm / 0.45 µm PVDF or nylon membranes with real-time clogging/breakage detection |
| Centrifugation | Horizontal rotor accommodating both 15 mL and 50 mL conical tubes |
| Extraction Salt Management | Independent salt dispensing channels per sample position |
| Brand | Raykol |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | DRQ |
| Pricing | Available Upon Request |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer | Raykol Group |
| Country of Origin | China |
| Model | ISP |
| Pricing | Available Upon Request |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ISP600 |
| Price Range | USD 140,000 – 280,000 |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ISP700 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | No. 3 to No. 75 |
| Pricing | Available Upon Request |
| Diameter | 3/8″ (9.6 mm) |
| Overall Length | 16″ (406 mm) |
| Coated Length | 12″ (305 mm) |
| Handle Dimensions | 2″ × 2″ (51 mm × 51 mm) |
| Coating Thickness Range | 7.0–171.0 µm (corresponding to rod numbers 3–75) |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | RESOLVEX® i300 |
| Platform Integration | FLUENT® Automation Suite |
| Regulatory Classification | Import (CE-IVD compliant architecture) |
| Distribution Model | Authorized Distributor Supply Channel |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HA01-01 |
| Pricing | Upon Request |
| Viscosity Range | 0–100 mPa·s |
| Flow Channel Depth | 50 µm |
| Sample Volume | 400 µL |
| Accuracy | ±1% FS, ±2% of reading |
| Repeatability | ±0.5% |
| Flow Rate | 0.5–450 µL/min |
| Operating Temperature Range | 15–50 °C |
| Temperature Control Accuracy | ±0.07 °C |
| Power Supply | 8 VDC |
| Syringe Fill Volume | 400 µL |
| Shear Rate Range | 6.5–5,850 s⁻¹ |
| Max Pressure | 12,000 Pa |
| Brand | Rocklabs |
|---|---|
| Origin | New Zealand |
| Product Type | Certified Reference Material (CRM) |
| Matrix Types | Oxide, Sulphide, Siliceous |
| Certified Elements | Pt (0.456–4.749 ppm), Pd (0.563–5.918 ppm), Au (0.0798–30.49 ppm), Ag (60.2–153.9 ppm) |
| Uncertainty | 95% confidence intervals reported for all certified values |
| Blank Levels | Au < 0.002 ppm |
| Packaging | 2.5 kg jars, 30 g & 50 g sachets (varies by material) |
| Certification | ISO/IEC 17034-accredited, recognized by IAG (International Association of Geoanalysts) |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Model | RTK Piston-Cylinder High-Pressure Apparatus (Automated) |
| Pressure Range | 0–4 GPa |
| Temperature Range | 25–1800 °C |
| Sample Chamber Diameter Options | 10 / 13 / 19 mm |
| Automation | Fully automated pressure ramping and isobaric hold |
| Thermal Ramp & Cool-down Rate | Programmable |
| Continuous Operation Duration | Hours to multi-day stable runs |
| Compliance | Designed for GLP-aligned research environments |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Model | RTK-PC-2 |
| Pressure Range | 0–4 GPa |
| Temperature Range | 25–1800 °C |
| Chamber Diameter Options | 10 / 13 / 19 mm |
| Automation | Fully Automated Pressure Ramp & Hold |
| Heating/Cooling Rate Control | Yes |
| Continuous Operation Duration | Hours to Days |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ROTAX 6.8 |
| Speed Range | 0–30 rpm (electronically adjustable) |
| Display | LCD speed indicator |
| Compliance | UNI 10802, DIN 38414 |
| Sample Capacity | up to 6 × 2 L bottles or 8 × 1 L bottles (with optional adapter) |
| Construction | chemically resistant cantilever shaft and housing |
| Safety | automatic rotation stop upon mechanical obstruction |
| Intended Use | aqueous solubility testing of pollutants |
| Brand | Safematic |
|---|---|
| Origin | Switzerland |
| Model | CCU-010 LV_CT |
| Vacuum Type | Low-Vacuum Thermal Evaporation System |
| Coating Method | Resistive Thermal Evaporation (Carbon Rope Feed) |
| Plasma Treatment | Optional Integrated Glow Discharge (GD-010) and Plasma Etching (ET-010) Modules |
| Thickness Monitoring | Dual-Position Quartz Crystal Microbalance (QCM) |
| Control Interface | TFT Touchscreen + Windows-Based Remote Software (RC-010) |
| Sample Stage | Ø ≥60 mm, Height-Adjustable & Tilt-Compatible |
| Compliance | Designed for SEM/EDS Sample Preparation per ISO 13822, ASTM E1558, and GLP-Compliant Workflow Support |
| Brand | Asahi Sokki |
|---|---|
| Origin | Japan |
| Model | MCA-1500E |
| Heating Capacity | 1.5 kW |
| Operating Voltage | Single-phase 200 V AC |
| Temperature Range | 80–500 °C |
| Air Flow Rate | 20–200 Nℓ/min |
| Maximum Operating Pressure | 0.3 MPa |
| Sheath Material | SUS (AISI 304 or equivalent) |
| Insulation Resistance | ≥5 MΩ @ 500 V DC |
| Dielectric Strength | 400 V AC, 1 min, leakage current ≤10 mA |
| Surface Temperature | Reduced via optimized thermal design |
| Energy Efficiency | ~15% lower power consumption vs. conventional air heaters |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Category | Domestic (China) |
| Capacity Range | 25–3000 mL |
| Pricing | Available Upon Request |
| Brand | Sartorius |
|---|---|
| Model | Midi Plus |
| Power | Rechargeable Li-ion battery (AC/DC compatible) |
| Weight | <120 g |
| Compatible Pipettes | 1–100 mL glass and plastic serological pipettes |
| Adapter Included | Proline 5 mL & 10 mL tip adapters |
| Control Method | Pressure-sensitive ergonomic button |
| Low-Battery Indicator | Yes |
| Stand Included | Yes |
| Optional Accessory | Wall-mounted holder |
| Brand | Sartorius |
|---|---|
| Origin | Finland (Manufactured) |
| Model | eLine |
| Type | Motorized Single-Channel Electronic Pipette |
| Power | Rechargeable Lithium-Ion Battery |
| Display | Backlit LCD with Icon-Based Interface |
| Pipetting Modes | 11 Predefined (e.g., Standard, Reverse, Dilution, Dispense, Repeat, Mix, Variable Volume, Stepwise, Programmed Aspirate/Dispense, Calibration Mode, Error Log Review) |
| User Programs | Up to 6 Custom Protocols with Audit Trail |
| Tip Ejection | Motorized, One-Touch Electronic Eject |
| Charging Options | Dedicated eLine Charging Station (Docking Cradle) or Optional AC Adapter (Fast Charge Support) |
| Ergonomics | Ambidextrous Design with Adjustable Grip Angle and Low Actuation Force |
| Compliance | ISO 8655-2:2022 (Pipettes), ISO 13485:2016 (QMS), CE Marked for IVDD & MDR |