Other Electrochemical Instruments
Filter
Showing 31–60 of 103 results
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | ECC-PAT-Core |
| Dimensions | 90 × 54 × 70 mm (H × W × D) |
| Electrode Diameter | 18 mm |
| Electrolyte Volume | as low as 0.05 cm³ |
| Weight | 640 g |
| Separator Diameter | 18 mm |
| Material | Battery-grade Al (lower plunger), Cu (upper plunger), PP (insulation sleeve), optional 316L stainless steel current collectors |
| Compatible With | All PAT-series test cells, ECC-Std, ECC-Ref, ECC-Combi, ECC-Air, ECC-DEMS, ECC-Press, ECC-Opto-Std, ECD-o-DL, ECD-2-DL |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | ECC-Ref |
| Dimensions | 90 × 54 × 70 mm (H × W × D) |
| Electrode Diameter | 18 mm |
| Electrolyte Volume | 0.1 mL (min.) |
| Weight | 640 g |
| Construction Materials | Stainless Steel (316L), PEEK, Aluminum (lower plunger), Copper (upper plunger), Polypropylene (PP), PTFE/PE sealing elements |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | ECD-3 |
| Displacement Resolution | ≤50 nm |
| Measurement Range | 0–500 µm |
| Linear Sensor Output | ±10 V DC |
| Linearity | <0.15% of full scale |
| Drift | ≤100 nm/h |
| Electrolyte Volume Requirement | ~1 mL |
| Electrode Diameter | 10 mm (max thickness: 1.0 mm) |
| Operating Temperature Range | −20 °C to +70 °C |
| Dimensions (H×W×D) | 230 × 100 × 110 mm |
| Weight | 1.5 kg |
| Compatible Electrolytes | Organic (e.g., LiPF₆ in EC/DMC), Aqueous (with Au upgrade kit) |
| Load on Working Electrode | Fixed 130 g |
| Housing Material | PEEK |
| Seals | EPDM |
| Electrode Separation | Fused quartz frit |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | ECD-3 Nano |
| Displacement Resolution | ≤5 nm |
| Measurement Range | 100 µm / 250 µm (selectable) |
| Linear Accuracy | <0.1% of full scale |
| Output Signal | DC voltage, –10 to +10 V |
| Sensor Type | High-precision capacitive transducer |
| Electrolyte Volume | ~1 mL (minimum), up to 3 mL |
| Electrode Compatibility | Disk electrodes up to Ø10 mm × 1.0 mm thickness |
| Operating Temperature Range | –20 °C to +70 °C (with external temperature control) |
| Dimensions (H×W×D) | 230 mm × 100 mm × 110 mm |
| Weight | 2.5 kg |
| Load on Working Electrode | Fixed 130 g (adjustable via optional load kit) |
| Sealing Materials | PEEK, EPDM, stainless steel 1.4404, or gold-plated components (aqueous-compatible upgrade) |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | PAT-Cell-Press |
| Pressure Range | 0–2.5 bar (abs) |
| Sensor Type | Laser-Welded Piezoresistive Transducer |
| Sealing | Glass-to-Metal + Single PE O-Ring |
| Dimensions (L×W×H) | 69 mm × 49 mm × 73 mm |
| Weight | 0.5 kg |
| Electrode Materials | Al (lower plunger), Cu (upper plunger), PP insulator sleeve |
| Optional Current Collectors | Stainless Steel 316L |
| Output Signals | Analog ±10 V (pressure, temperature, current, half-cell voltage) |
| Integrated Data Logger | USB interface, simultaneous recording of pressure, temperature, cell current, and half-cell potential |
| Compliance | Helium-leak tested (<1×10⁻⁹ mbar·L/s), battery-grade material certified per ISO 9001 manufacturing controls |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | PAT-Single-Stand |
| Dimensions (W × D) | 105 × 113 mm |
| Height | 80 mm (standalone), 110 mm (with PAT-Cell installed) |
| Weight | 0.56 kg (standalone), 0.96 kg (with PAT-Cell) |
| Material | Battery-grade Al (lower plunger), Cu (upper plunger), PP insulator sleeve |
| Optional current collectors | Stainless steel 316L |
| Electrode configuration | 2-electrode or 3-electrode (with integrated ring-type reference electrode) |
| Connectivity | 4-mm banana sockets or Sub-D hardwired interface |
| Compatibility | Universal potentiostats (e.g., Gamry Reference 3000), battery cyclers, and PAT-series test cells |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | PAT-Stand-4 |
| Dimensions (W × D) | 301 × 119 mm |
| Height | 84 mm (standalone) / 114 mm (with PAT-Cell mounted) |
| Weight | 0.67 kg |
| Compatibility | Universal potentiostats/galvanostats (e.g., Gamry Reference 3000), PAT-Core and ECC-PAT-Core cells |
| Electrical Interface | 4-mm banana sockets or Sub-D hardwired connector |
| Environmental Suitability | Compatible with gloveboxes and environmental chambers |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | PAT-Tray |
| Dimensions (W × D) | 315 mm × 315 mm |
| Height | 120 mm (empty) / 148 mm (loaded) |
| Weight | 6.9 kg (empty) |
| Channel Capacity | 16 (4 × 4 matrix) |
| Integrated Data Logger | Voltage (half-cell & full-cell), Current, Time, Temperature |
| Compatibility | Gamry Reference 3000, BioLogic VMP-3, Arbin BT2000, and other standard potentiostats/galvanostats |
| Material | Battery-grade Al (lower plunger), Cu (upper plunger), PP insulation sleeve |
| Operating Environment | Compatible with Binder KB53 and equivalent climate chambers |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Nova UC1000 |
| Pricing | Upon Request |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | ExTab |
| Pricing | Available Upon Request |
| Brand | -- |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TEA4000 |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Models | HQ1110, HQ1130, HQ1140, HQ2100, HQ2200 |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AKF-3B |
| Pricing | Upon Request |
| Measurement Principle | Coulometric Titration (Microcoulometry) |
| Sample Form | Liquid |
| Detection Method | Potentiometric Endpoint Detection |
| Display | Color LCD Touchscreen |
| Measurement Range | Bromine Number: 0–300 g Br/100g oil |
| Bromine Index | 1–1000 mg Br/100g oil |
| Resolution | 0.01 mg Br |
| Detection Limit | 0.1 mg Br |
| Accuracy | ±3% (for bromine index ≥1 mg Br/100g oil) |
| Electrolysis Control | Multi-stage adjustable |
| Endpoint Sensor | Dual Platinum Electrodes |
| Cell Volume | 200 mL |
| Stirring Mechanism | Magnetic Stirring |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 320 × 210 × 180 mm |
| Weight | ~3 kg |
| Communication Interface | RS232 |
| Compliance Standards | SH/T 0630–1996, SH/T 1551–2018, SH/T 1767–2008 (2015), GB/T 11136–1989 (2004), GB/T 1815–2019, ASTM D1492 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ElectraSyn 2.0 Package |
| Price | Upon Request |
| Input Voltage | 48 VDC |
| Max Input Current | 1500 mA |
| Output Voltage | 30 V / 10 V |
| Output Current | 100 mA |
| Motor Power | 9 W |
| Speed Range | 50–1500 rpm |
| Speed Setting Accuracy | ±10 rpm |
| Max Stirring Volume (H₂O) | 0.1 L |
| Stir Bar Length Compatibility | 8–16 mm |
| Speed Control | Rotary Knob |
| Display | TFT |
| Output Current Resolution | 0.1 mA |
| Output Voltage Resolution | 0.01 V |
| Current Measurement Resolution | 0.1 mA |
| Voltage Measurement Resolution | 0.1 V |
| Current Measurement Accuracy | ±0.1 mA |
| Voltage Measurement Accuracy | ±0.01 V |
| Dimensions (W×D×H) | 130 × 150 × 250 mm |
| Weight | 3.55 kg |
| Operating Temperature | 5–50 °C |
| Relative Humidity Limit | 80 % RH |
| Ingress Protection | IP40 per DIN EN 60529 |
| USB Interface | Yes |
| Mains Input | 100–240 V AC, 50/60 Hz |
| Device Input Power | 39.84 W |
| Standby Power Consumption | 5 W |
| DC Supply | 48 V = |
| DC Current Draw | 750 mA |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ElectraSyn 2.0 Pro Package |
| Voltage Input (Nominal) | 48 VDC |
| Max Input Current | 1500 mA |
| Output Voltage | 30 V / 10 V |
| Output Current | 100 mA |
| Motor Output Power | 9 W |
| Speed Range | 50–1500 rpm |
| Speed Setting Accuracy | ±10 rpm |
| Max Stirring Volume (H₂O) | 0.1 L |
| Stir Bar Length Compatibility | 8–16 mm |
| Output Current Resolution | 0.1 mA |
| Output Voltage Resolution | 0.01 V |
| Current Measurement Resolution | 0.1 mA |
| Voltage Measurement Resolution | 0.1 V |
| Current Measurement Accuracy | ±0.1 mA |
| Voltage Measurement Accuracy | ±0.01 V |
| Dimensions (W×D×H) | 130 × 150 × 250 mm |
| Weight | 3.55 kg |
| Operating Temperature Range | 5–50 °C |
| Max Relative Humidity | 80 % |
| Ingress Protection | IP40 (DIN EN 60529) |
| USB Interface | Yes |
| AC Input | 100–240 V, 50/60 Hz |
| Total Input Power | 39.84 W |
| Standby Power Consumption | 5 W |
| DC Supply | 48 V =, Current Draw: 750 mA |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-362 |
| Compliance | UL 1581, VDE 0472 |
| Oscillation Frequency | 10–40 cycles per minute (CPM), adjustable |
| Stroke Length | 40–100 mm, adjustable |
| Load Mass | 450 g ±5 g (standard), customizable options available |
| Counting Function | Automatic cycle counter with digital display |
| Drive Mechanism | Electromechanical cam-driven linear reciprocating motion |
| Sample Fixturing | Dedicated clamping fixture for 30 mm wire segment with printed surface oriented upward |
| Construction | Powder-coated steel frame with precision-machined aluminum test platform |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | KY-200.1 |
| Pricing | Available Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | KY4S |
| Pricing | Available Upon Request |
| Sample Type | Liquid |
| Method | Potentiometric Titration |
| Detection Limit | ≥3 µg/g |
| Minimum Burette Delivery Volume | 0.01 mL |
| Potential Measurement Range | 0 to ±1999.5 mV |
| Burette Accuracy | ±0.1% F.S. |
| Electronic Unit Basic Error | ±0.1% of full scale + 0.5 mV |
| Relative Error | ≤5% |
| Brand | LANYO |
|---|---|
| Model | SOMA Series |
| Standard Compliance | NY/T 1121.6–2006, NY/T 85–1988, LY/T 1237–1999, GB/T 33469–2016 Annex C |
| Heating Stations | 3 independent micro-boiling reflux positions with PID temperature control |
| Reagent Dispensing Accuracy | ≤0.3% (v/v) |
| Titration Endpoint Detection | Biomimetic colorimetric endpoint recognition |
| Reagent Port | 1 dedicated channel with isolated fluid path |
| Tube Cleaning | Programmable pre-run automated line rinse and conditioning cycle |
| Software Interface | Integrated GUI with real-time process logging, CSV export, and LIMS-compatible data transmission protocol |
| Safety | Fully enclosed reagent handling |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | KDN-1 |
| Pricing | Upon Request |
| Display | 4.3-inch high-resolution color LCD |
| Operation Mode | Dual automatic/manual |
| Alkali Reagent Delivery | Automated quantitative dosing |
| Boric Acid Solution Delivery | Automated quantitative dosing |
| Diluent Addition | Manual or automatic selection |
| Distillation Time Setting | Programmable up to 60 min |
| Distillation Speed | 3–6 min per sample |
| Nitrogen Measurement Range | 0.1–240 mg |
| Nitrogen Recovery Rate | ≥99.5% |
| Sample Capacity | ≤6 g (solid) or ≤16 mL (liquid) |
| Condensate Water Consumption | 1.5 L/min |
| Heating Tube Temperature Monitoring | Real-time |
| Rinse Control System | Automated post-distillation tubing rinse |
| Safety Features | Digestion tube presence detection, emergency stop, fault self-diagnosis with audible/visual alarm |
| Cooling Water Flow Sensing | Integrated flow sensor |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Rated Power | 1.3 kW |
| Dimensions (W×D×H) | 400 × 385 × 735 mm |
| Net Weight | 30 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SCH-01B |
| Pricing | Available upon Request |
| Sample Positions | 16×50 mL / 15×100 mL / 14×200 mL |
| Stirring Options | Top or bottom magnetic stirring, 0–45 speed levels |
| Cleaning System | Dual-pump architecture — PUMP-1 (diaphragm pump) for spray rinsing and PUMP-2 (peristaltic pump) for waste aspiration |
| Interfaces | USB + RS-232 |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | 80–305 VAC, 47–63 Hz |
| Dimensions (W×D×H) | 420×580×500 mm |
| Weight | ~14 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SCH-02B |
| Pricing | Upon Request |
| Sample Positions | 30×50 mL / 24×100 mL / 18×200 mL |
| Stirring Options | Top or Bottom Stirring, 0–45 Speed Levels |
| Cleaning Mechanism | Dual-pump System (PUMP-1 Diaphragm Pump + PUMP-2 Peristaltic Pump), Spray & Immersion Rinse |
| Interfaces | USB + RS232 |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | 80–305 VAC, 47–63 Hz |
| Dimensions (W×D×H) | 420×580×500 mm |
| Weight | ~16 kg |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MHW-3 |
| Drive Mechanism | Water-Hydraulic |
| Motion Resolution (Fine) | 0.2 µm (min. scale) |
| Coarse Travel Range (X/Y/Z) | 30 mm each |
| Fine Travel per Full Knob Rotation | 50 µm |
| Coarse Travel per Full Knob Rotation | ~4 mm |
| Control Unit Dimensions | 115 × 115 × 132 mm, 1.6 kg |
| Drive Unit Dimensions | 155 × 155 × 100 mm, 900 g |
| Hydraulic Tubing Length | 900 mm |
| Joint Type | Spherical Ball Joint (B-9 Standard) |
| Electrode Holder | H-12 Type |
| Included Accessories | Hex Key Wrench, Dual Adapter, Isolation Mounting Platform |
| Brand | MinTech |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MT-CNE200 |
| Price | Upon Request |
| Functionality | Electrode Fabrication & Thermal Annealing |
| R<sub>G</sub> Ratio | As low as 1.1 |
| Template Material | Fused Silica Quartz |
| Tip Diameter Range | 10 nm – 50 µm (Optimized for 200–500 nm) |
| Electrode Types | Carbon Nanoelectrodes, Carbon Micronelectrodes, Carbon Nanotip Electrodes, Derivative Electrodes (Metallic Nanoelectrodes, Metal Oxide Nanoelectrodes) |
| Dimensions | 480 × 340 × 320 mm |
| Weight | ~20 kg |
| Brand | MinTech |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | MT-PSAM/IMMS100 |
| Pricing | Upon Request |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | MM-3 |
| Gross Weight | 790 g |
| Dimensions (W×D×H) | 105 × 70 × 145 mm |
| Coarse Movement Range (X/Y/Z) | 30 / 20 / 35 mm |
| Fine Movement Range (X-axis only) | 7 mm |
| Fine Adjustment Resolution | 10 µm per click (250 µm per full rotation) |
| Electrode Holder | Compatible with H-1 holder and standard 1.2–1.5 mm diameter electrode shafts |
| Ergonomic Design | Dual-handled X/Z control, rack-and-pinion coarse drive, gravity-compensated tension adjustment |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | MMN-33 |
| Axis Configuration | Single-axis coarse/fine adjustment (X-Z dual-hand control) |
| Coarse Travel Range | X 40 mm, Y 20 mm, Z 35 mm |
| Fine Travel Range | X 7 mm |
| Minimum Step Size | 10 µm |
| Maximum Rotation Speed | 250 µm/rev |
| Electrode Holder Compatibility | H-1 electrode holder included |
| Dimensions (W×D×H) | 105 × 70 × 155 mm |
| Weight | 880 g |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MMO-220A |
| Drive Principle | Oil-Hydraulic |
| Axis Configuration | Single-Axis (Z-axis fine adjustment) |
| Fine Adjustment Range | 10 mm |
| Minimum Step Resolution | 1 µm |
| Coarse Rotation per Full Turn | 250 µm |
| Control Unit Dimensions (W×D×H) | 65 × 88 × 93 mm, 630 g |
| Actuator Unit Dimensions (W×D×H) | 52 × 20 × 35 mm, 38 g |
| Hydraulic Tubing Length | 0.9 m |
| Compatibility | Mounts to standard 3-axis micromanipulators (e.g., MO-202, MN-4, or equivalent ball-joint platforms) |
| Operating Principle | Continuous hydrostatic pressure transmission via incompressible silicone oil |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MO-10 |
| Actuation Principle | Oil-hydraulic displacement amplification |
| Control Mechanism | Drum-type rotary actuator |
| Total Travel Range | 10 mm |
| Fine Adjustment per Full Knob Rotation | 500 µm |
| Minimum Graduation | 2 µm |
| Hydraulic Tubing Length | 1.5 m |
| Control Unit Dimensions (W×D×H) | 65 × 88 × 93 mm |
| Control Unit Weight | 630 g |
| Drive Unit Dimensions (W×D×H) | 30 × 20 × 125 mm |
| Drive Unit Weight | 50 g |
| Mounting Compatibility | Standard 3-axis manual micromanipulator rails (e.g., Narishige MMO-2, MN-4, or equivalent) |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MP-2 |
| Motion Range (Coarse) | X 60 mm, Z 50 mm |
| Motion Range (Fine) | X 4 mm, Z 4 mm, Y 40 mm |
| Fine Adjustment Resolution | 10 µm per click (X/Z/Y) |
| Coarse Knob Travel per Full Rotation | X/Z 250 µm, Y 500 µm |
| Pivot & Tilt Functionality | Integrated |
| Electrode Holder Included | H-1 |
| Dimensions (W×D×H) | 150 × 130 × 210 mm |
| Weight | 4.8 kg |