Other Electrochemical Instruments
Filter
Showing 61–90 of 103 results
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-3333 |
| Dimensions (W×D×H) | 126 × 43 × 145 mm |
| Weight | 340 g |
| Coarse Motion Range (X/Y/Z) | 40 / 12 / 30 mm |
| Fine Motion Range (X) | 7 mm |
| Minimum Step Size | 10 µm |
| Maximum Step Size | 250 µm |
| Compatible Electrode Holder | H-1 |
| Drive Mechanism | X-4 Rotational X-Block |
| Construction | Compact, Low-Profile Monoblock Design |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-44 |
| Mounting Interface | Ø4 mm rod |
| Gross Adjustment Range | 22 mm |
| Pivot Motion Axis | Y-axis |
| Tilt Motion Axis | Z-axis |
| Dimensions (W×D×H) | 65 × 25 × 50 mm |
| Weight | 70 g |
| Standard Accessories | H-7C Pipette Holder, Allen Wrench |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model Variants | MTK-1-O1/O2/O3/N1/N2/N3/N4/Z1/Z2/L1/L2 |
| Drive Principle | Hydraulic |
| Axes | X, Y, Z, Rotation (θ) |
| X/Y/Z Travel (Hydraulic Fine Control) | 10 mm |
| X/Y/Z Step Resolution (Fine Button) | 250 µm (X/Y), 1000 µm (Z) |
| Minimum Increment (Fine Adjustment) | 5 µm (X/Y), 20 µm (Z) |
| Coarse Return Stroke (Manual Reset) | 50 mm |
| Pipette Tip Angular Range | 15°–40° |
| Pipette Tip-to-Anchoring Point Distance | Adjustable & Reproducible |
| Hydraulic Tubing Length | 0.6 m |
| Control Unit Dimensions (W×D×H) | 85.6 × 225–235 × 151–171 mm, ~1.9 kg |
| Driver Unit Dimensions (W×D×H) | 108–138 × 145–155 × 100–150 mm, ~820 g |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | NMN-21 |
| Minimum Adjustment Resolution | 1 µm |
| Coarse Travel (X/Y/Z) | 15 mm each axis |
| Fine Travel (X/Y/Z) | 6 mm each axis (via full-turn knob), 250 µm per full turn |
| Dimensions (W×D×H) | 110 × 170 × 105 mm |
| Weight | 930 g |
| Mounting Compatibility | UST-2 solid universal joint, GJ-12 magnetic base, AP-13-3 clamp holder, H-13 electric joystick, MHW-4-1 hydraulic manipulator interface |
| Accessories Included | UST-2 universal joint, mounting platform, H-13 electric joystick, hex wrench |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | NMN-25 |
| Type | Manual Three-Axis Micromanipulator for Electrophysiology |
| Motion Range (X/Y/Z) | Coarse 15 mm / Fine 6 mm (Z), Fine 6 mm (X), Fine 6 mm (Y) |
| Fine Adjustment Resolution | 250 µm per full rotation |
| Dimensions (W×D×H) | 155 × 60 × 100 mm |
| Weight | 600 g |
| Mounting Interface | Universal H-12 Motorized Handle Compatible |
| Vibration Isolation | Optimized for integration with optical tables and active/passive isolation platforms |
| Compliance | Designed for GLP-compliant electrophysiology labs |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | PC-100 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | ~70 W |
| Heating Element | Kanthal wire, max. 2.5 V |
| Pulling Force | ≈25 g × 2 (light) or ≈100 g × 2 (heavy) |
| Dimensions | 205 × 190 × 185 mm (W × D × H) |
| Weight | 3.45 kg |
| Tip Diameter Range | down to 1 µm |
| Capillary Compatibility | φ1 mm × 90 mm glass capillaries |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | UM-1F, UM-1FC |
| Fine Adjustment Range (UM-1F) | 20 mm (X-axis), 250 µm per revolution |
| Coarse + Fine Adjustment Range (UM-1FC) | 14 mm coarse + 6 mm fine (X-axis), 250 µm per revolution |
| Dimensions (UM-1F) | 58 mm (W) × 23 mm (D) × 60 mm (H) |
| Weight | 78 g |
| Dimensions (UM-1FC) | 80 mm (W) × 23 mm (D) × 60 mm (H) |
| Weight | 92 g |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | UM-3C, UMM-3C |
| Gross Movement Range (UM-3C) | X±10 mm, Y±10 mm, Z±10 mm |
| Gross Movement Range (UMM-3C) | X±15 mm, Y±15 mm, Z±15 mm |
| Rotation | Manual 360° continuous |
| Mounting Shaft Diameter (UM-3C) | 10 mm |
| Mounting Shaft Diameter (UMM-3C) | 12 mm |
| Compatible Magnetic Stands | GJ-1 (UM-3C), GJ-8 (UMM-3C) |
| Dimensions (UM-3C) | 120 × 60 × 95 mm |
| Weight (UM-3C) | 235 g |
| Dimensions (UMM-3C) | 145 × 75 × 130 mm |
| Weight (UMM-3C) | 475 g |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | UMM-3FC |
| Mounting Rod Diameter | 12 mm |
| Travel Range (Coarse) | X/Y/Z ±24 mm |
| Travel Range (Fine) | X/Y/Z ±6 mm |
| Fine Adjustment per Full Knob Rotation | 250 µm |
| Integrated Rotation Mechanism | Yes |
| Dimensions (W×D×H) | 143 × 92 × 158 mm |
| Weight | 510 g |
| Compatible Magnetic Base | GJ-8 (sold separately) |
| Brand | Novocontrol Technologies |
|---|---|
| Origin | Germany |
| Model | NEISYS |
| Frequency Range | 3 µHz – 100 MHz |
| Sampling Rate | 10⁷ points/sec |
| Impedance Range | 10⁻⁴ Ω – 1 TΩ |
| Loss Factor Accuracy | ±1×10⁻⁴ |
| Architecture | Four-Electrode, Separated Current/Voltage Signal Paths |
| Thermal Expansion Option | Yes |
| Operating Modes | Frequency-Domain (EIS, Dielectric, Conductivity, Loss Tangent) & Time-Domain (CV, LSV, SWV, CA, CP, Galvanostatic/Potentiostatic Cycling, Battery Charge/Discharge, Capacitor Charging/Discharging) |
| Compliance Support | ASTM D257, ISO 60270, IEC 60601-2-60 (for dielectric safety), GLP/GMP-ready data audit trail |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | STTEMP30 |
| Pricing | Upon Request |
| Electrode Type | Temperature Sensor Probe |
| Temperature Measurement Range | 0 – 100 °C |
| Cable Length | 1.1 m |
| Shaft Material | Stainless Steel (316 SS typical for lab-grade probes) |
| Overall Dimensions | 120 mm × 12 mm (L × Ø) |
| Net Weight | 80 g |
| Thermistor Resistance | 30 kΩ nominal at 25 °C |
| Operating Environment | 10 – 40 °C, ≤85% RH, non-condensing |
| Brand | SANXIN Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | 222 mV ORP Standard Solution |
| Packaging Options | 250 mL or 50 mL |
| Pricing | Available Upon Request |
| Brand | EL-Cell |
|---|---|
| Origin | Germany |
| Model | PAT-Chamber |
| Dimensions (W × D) | 380 mm × 640 mm |
| Height (open/closed lid) | 600 mm / 375 mm |
| Weight (empty) | 32 kg |
| Compatibility | PAT-Core test cells, ECC-PAT-Core cells, PAT-16, PAT-Pressure |
| Data Channels | Battery current, battery voltage, half-cell voltage, temperature, single-cell pressure |
| Interface | Compatible with standard potentiostats/galvanostats and battery cyclers |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | 616A, 636A |
| Rotation Speed Range | 50–10,000 rpm |
| Speed Accuracy | < ±1% |
| Speed Control | Analog voltage input (0–10 V DC, linear proportionality) |
| Motor Type | Solid-state servo-controlled permanent magnet DC motor |
| Power Supply | Bipolar, high-voltage DC |
| Compatibility | Integrates with standard potentiostats/galvanostats including PAR electrochemical workstations |
| Compliance | Designed for ASTM G102, ASTM G59, ISO 17475, and electrochemical kinetic studies per IUPAC recommendations |
| Application Domain | Electrocatalysis (HER, OER, HOR, ORR), mass-transport-controlled reaction analysis, reaction intermediate detection |
| Brand | REMEX |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MPI-EII |
| Pricing | Available Upon Request |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | 10 MΩ |
| Current Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 0.001–65 V/s |
| Luminescence Dynamic Range | >5 decades |
| Photometric Accuracy | <0.05% |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Amplifier Drift | <0.05% |
| Peak-to-Peak Noise | ≤0.5 mV (1× gain) |
| Input Impedance (Optical) | ≥10 MΩ |
| Integration Time | 0.01–10 s |
| Sampling Rate | 1–200 Hz |
| PMT High Voltage | −100 V to −1000 V |
| Spectral Range | 230–920 nm (λₚₑₐₖ = 630 nm) |
| Anode Sensitivity | >2000 A/lm |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RPEC-A |
| Light Source | 300 W Xenon Arc Lamp |
| Spectral Range | 200–1000 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | ±0.1 nm |
| Minimum Wavelength Step | 0.01 nm |
| Spectral Bandwidth | 0.054–16.2 nm (adjustable slit: 10 µm–3 mm) |
| Electrochemical Potential Range | −10 V to +10 V |
| Current Range | ±250 mA |
| Sensitivity | 1 × 10⁻⁹ A to 1 × 10⁻² A (8 decades) |
| Input Bias Current | <50 pA |
| Scan Rate | 0.001–65 V/s |
| Reference Electrode Input Impedance | 10 MΩ |
| Operating System | Windows-based Dedicated Software |
| Brand | REMEX (Xi’an Remex) |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RPEL-B |
| Pricing | Upon Request |
| Potential Applications | Antigen/Antibody Detection, Pathogen Screening (e.g., Influenza A, HIV, Plague), Small-Molecule Biomarker Analysis (Hormones, Toxins, Glucose, Amino Acids) |
| Operating Modes | Standalone & PC-Connected (USB) |
| Electrode Format | Disposable Screen-Printed Electrodes (WE: Pt, CE: Pt, RE: Ag/AgCl or user-specified) |
| Dimensions | 140 × 110 × 110 mm (L×W×H) |
| Weight | <0.8 kg |
| Battery Life | >10 h continuous operation |
| Data Storage | Up to 1000 assay records |
| Optical Detection Range | 230–920 nm |
| Electrochemical Range | Potential: −3 V to +3 V |
| Current | ±50 mA |
| Scan Rate | 0.001–200 V/s |
| Sampling Rate | 1–200 points/s |
| Dynamic Range | >5 decades |
| Measurement Accuracy | <0.05% FS |
| Interfaces | USB 2.0 (PC control/data transfer), DB9 RS-232 (mini-printer output) |
| Integrated Magnetic Separation Module | Yes |
| Sample Volume | 5–10 µL per test |
| Compatible Substrates | Paper-based chips, ceramic chips, custom solid-phase electrochemiluminescent platforms |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SENHK-258 |
| Pricing | Available Upon Request |
| Measurement Range | 0–200.0 µg/L and 0–20.00 mg/L (auto-ranging) |
| Accuracy | ±<3% of reading |
| Temperature Compensation Range | 0–50 °C |
| Minimum Sample Flow Rate | 50 mL/min |
| Response Time (t₉₀) | ≤60 s at 25 °C |
| Power Supply | 2 × 3.6 V rechargeable Li-ion batteries |
| Continuous Operation Time (fully charged) | 15 h |
| Ingress Protection Rating | IP66 |
| Dimensions (L×W×H) | 190 × 250 × 180 mm |
| Weight (including charging dock) | 2.3 kg |
| Brand | SOP TOP |
|---|---|
| Model | CON6300 |
| Conductivity Range | 0–5.000 µS/cm, 0–50.00 µS/cm, 0–500.0 µS/cm, 0–5000 µS/cm, 0–50.00 mS/cm, 0–500.0 mS/cm |
| TDS Range | 0–500 ppt |
| Salinity Range | 0–325 ppt |
| Conductivity Resolution | 0.001–1 µS/cm, 0.01 mS/cm |
| Conductivity Accuracy | ±1% of Full Scale |
| Resistivity Range | 0.00–18.30 MΩ·cm |
| Resistivity Resolution | 0.01 MΩ·cm |
| Temperature Range | −5.0–120.0 °C (23.0–248.0 °F) |
| Temperature Accuracy | ±0.3 °C, ±0.5 °F |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temp. Compensation | Auto/Manual |
| Reference Temp. | 15.0–30.0 °C (default 25.0 °C) |
| Temp. Coefficient | 0.00–9.99% (default 2.00%) |
| TDS Factor | 0.40–1.00 (default 0.50) |
| Salinity Factor | 0.65 |
| Cell Constant Options | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Data Storage | 100 memory slots |
| Power | Rechargeable 3.7 V Li-ion battery (base-integrated, battery not included) |
| Interface | USB port for PC connectivity |
| Display | 5-inch multi-line LCD with high-brightness backlight |
| Features | Auto-hold, electrode diagnostics, temperature offset adjustment, key beep, programmable auto-off (default 10 min idle) |
| Brand | SOP TOP |
|---|---|
| Model | CON6301 |
| Conductivity Range | 0–5.000 µS/cm, 0–50.00 µS/cm, 0–500.0 µS/cm, 0–5000 µS/cm, 0–50.00 mS/cm, 0–500.0 mS/cm |
| TDS Range | 0–500 ppt |
| Salinity Range | 0–325 ppt |
| Conductivity Resolution | 0.001–1 µS/cm, 0.01 mS/cm |
| Conductivity Accuracy | ±1% of Full Scale |
| Resistivity Range | 0.00–18.30 MΩ·cm |
| Resistivity Resolution | 0.01 MΩ·cm |
| Temperature Range | −5.0–120.0 °C (23.0–248.0 °F) |
| Temperature Accuracy | ±0.3 °C, ±0.5 °F |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temp. Compensation | Auto/Manual |
| Reference Temp. | 15.0–30.0 °C (factory set at 25.0 °C) |
| Temp. Coefficient | 0.00–9.99% (factory default 2.00%) |
| TDS Factor | 0.40–1.00 (factory default 0.50) |
| Salinity Factor | 0.65 |
| Cell Constant Options | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| IP Rating | IP67 |
| Data Storage | 100 measurement records |
| Power | 2 × 1.5 V AA batteries |
| Auto-Off | Configurable (default: 10 min idle) |
| Brand | SOP TOP |
|---|---|
| Model | DO35 |
| Type | Portable Electrochemical Dissolved Oxygen Meter |
| Measurement Principle | Clark-type Polarographic Membrane Electrode |
| Display | Multi-line LED with backlight (22 × 32 mm) |
| Protection Rating | IP67 |
| Power Supply | 1 × AA alkaline battery (1.5 V) |
| Auto-off | 6 min inactivity with data retention |
| Data Storage | 10 measurement records |
| Operating Temperature | 0–60.0 °C (32–140.0 °F) |
| DO Range | 0.00–20.00 mg/L and 0.0–200.0 % saturation |
| Resolution | 0.01 mg/L, 0.1 %, 0.1 °C, 1 °F |
| Accuracy | ±1.5 % of full scale |
| Temperature Compensation | Automatic or manual |
| Atmospheric Pressure Compensation | 600–1100 mbar |
| Salinity Compensation | 0.0–140.0 ppt |
| Calibration | 1-point or 2-point (air-saturated water or zero-oxygen solution) |
| Hold Function | Yes |
| Low-Battery Indicator | Yes |
| Brand | SOP TOP |
|---|---|
| Origin | Shanghai, China |
| Model | DO6400 |
| Measurement Range | 0.00–40.00 mg/L, 0.0–400.0% |
| Resolution | 0.01 mg/L, 0.1% |
| Accuracy | ±1.5% F.S. |
| Temperature Range | −5.0–120.0 °C (23.0–248.0 °F) |
| Temp. Resolution | 0.1 °C/°F |
| Temp. Accuracy | ±0.3 °C, ±0.5 °F |
| Salinity Compensation | 0.0–45.0 ppt |
| Pressure Compensation | 450–800 mmHg (0.500–1.100 bar) |
| Pipeline Pressure Compensation | 0.00–1.00 kg |
| Depth Compensation | 0.0–10.0 m |
| Data Storage | 100 sets |
| Auto-off | Configurable (default: 10 min idle) |
| Brand | SOP TOP |
|---|---|
| Model | ION6500 |
| Type | Benchtop Ion-Selective Electrode (ISE) Meter |
| Measurement Principle | Potentiometric Ion-Selective Electrode Detection |
| pH Range | −2.000 to 20.000 |
| mV Range | −2000.0 to +2000.0 mV |
| Ion Concentration Range | 0.000–9999 mg/L |
| Temperature Range | −10.0 to 120.0 °C (14.0–248.0 °F) |
| Resolution | 0.001 pH / 0.1 mV / 0.001 mg/L / 0.1 °C / 0.1 °F |
| Accuracy | ±0.001 pH / ±0.2 mV / ±0.005 mg/L / ±0.3 °C / ±0.5 °F |
| Calibration | Up to 5-point pH, up to 7-point ISE |
| Data Storage | 1000 measurement records |
| Interface | USB-B port for PC connectivity |
| Power | Internal rechargeable 3.7 V Li-ion battery (battery not included) |
| Display | 5-inch LED, 120° viewing angle |
| Compliance | Designed per IEC 61010-1 for laboratory electrical safety |
| Software | Included Windows-compatible data acquisition software with audit trail logging capability |
| Brand | SOP TOP |
|---|---|
| Model | ION6501 |
| Type | Portable Electrochemical Ion Analyzer |
| Measurement Principles | Potentiometric Ion-Selective Electrode (ISE) Method |
| pH Range | −2.000 to 20.000 pH |
| mV Range | −2000.0 to +2000.0 mV |
| Ion Concentration Range | 0.000–9999 mg/L (ion-specific, dependent on calibrated ISE) |
| Temperature Range | −10.0 to 120.0 °C (14.0 to 248.0 °F) |
| Temperature Compensation | Automatic or Manual |
| Resolution | 0.001 pH / 0.1 mV / 0.001 mg/L / 0.1 °C / 0.1 °F |
| Accuracy | ±0.001 pH / ±0.2 mV / ±0.005 mg/L / ±0.3 °C / ±0.5 °F |
| Calibration | Up to 5-point pH calibration |
| Calibration Reminders | Configurable interval (0–60 days) |
| Data Storage | 1000 measurement records with timestamp, user ID, instrument ID, and calibration metadata |
| Power Supply | 2 × 1.5 V AA alkaline batteries |
| Display | 3.2-inch multi-line LCD with anti-scratch coating and adjustable high-brightness backlight |
| Communication Interface | USB 2.0 compliant port |
| Software | Windows-compatible data acquisition software with audit trail logging capability |
| Auto-Power-Off | Programmable (default: 10 min idle timeout) |
| User Authentication | 4-digit password protection |
| Instrument & User ID Customization | 4-digit serial number + 2-digit user code |
| Date/Time Format Options | YY/MM/DD, MM/DD/YY, DD/MM/YY |
| Reading Lock Function | Enable/disable |
| Temperature Offset Adjustment | ±5.0 °C (±9.0 °F) |
| Real-time Calibration Diagnostics | Slope (%), offset (mV), and calibrated point count displayed during/after calibration |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | DO6401 |
| Measurement Range | 0.00–40.00 mg/L and 0.0–400.0% saturation |
| Resolution | 0.01 mg/L, 0.1% |
| Accuracy | ±1.5% F.S. |
| Temperature Range | −5.0 to 120.0 °C (23.0 to 248.0 °F) |
| Temp. Resolution | 0.1 °C / 0.1 °F |
| Temp. Accuracy | ±0.3 °C / ±0.5 °F |
| Salinity Compensation | 0.0–45.0 ppt |
| Pressure Compensation | 450–800 mmHg or 0.500–1.100 bar |
| Pipe Pressure Compensation | 0.00–1.00 kg |
| Depth Compensation | 0.0–10.0 m |
| IP Rating | IP67 |
| Data Storage | 100 sets |
| Auto Power-Off | Configurable (default: 10 min inactivity) |
| Display | 3.2-inch multi-line LCD with anti-scratch coating |
| Power | 2 × 1.5 V AA batteries |
| Electrode Diagnostics | Offset & Slope display, self-diagnostic status |
| Connectivity | Optional USB interface |
| Software | Optional data acquisition software with PC compatibility |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | CON35 |
| Measurement Range | 0–200.0 µS/cm (ppm), 0–50.0 mS/cm (ppt) |
| Temperature Range | 0–60.0 °C / 32–140.0 °F |
| Temperature Compensation | Automatic or Manual |
| Resolution | 0.1 / 1 µS/cm (ppm), 0.1 / 1 mS/cm (ppt), 0.1 °C, 1 °F |
| Accuracy | ±1% F.S. |
| Temperature Coefficient Adjustment | 0.00–10.00% |
| TDS Conversion Factor | 0.40–1.00 |
| Salinity Factor | 0.65 |
| Electrode Material | PPS-encapsulated graphite conductivity sensor |
| Calibration | Single-point auto-ranging calibration |
| Data Storage | 10 measurement records |
| Ingress Protection | IP67 |
| Display | Multi-line LED, 22 × 32 mm active area with energy-efficient backlight |
| Power Supply | 1 × AA alkaline battery (1.5 V) |
| Brand | Sutter Instrument |
|---|---|
| Origin | USA |
| Product Line | Capillary Glass & Filaments |
| Wall Type Options | Standard Wall, Thin Wall, Multibarrel, Quartz |
| Material | Borosilicate Glass (e.g., 7052, 7740) and Fused Quartz |
| Outer Diameter Range | 1.00–2.00 mm |
| Inner Diameter Range | 0.30–1.56 mm |
| Length Options | 7.5 cm, 10 cm, 15 cm |
| Packaging Quantities | 75–250 units per pack |
| Filament Availability | With or Without Internal Filament |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Product Type | Replacement Filament Heating Elements |
| Compatible Models | P-1000, P-97, P-87, P80PC, P80C, PC-84, P-77B, P-30, P-2000, P-77A |
| Filament Types | Box (square), Trough (rectangular), Loop, Custom Pt/Ir, Nichrome |
| Dimensions Range | 1.5–4.5 mm width |
| Material Options | Kanthal A1, Nichrome, Platinum/Iridium alloy |
| Packaging | Minimum order quantity = 4 filaments |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC-200 / MPC-385 / MPC-325 |
| Drive Type | Motorized (DC servo) |
| Position Resolution | ≤ 10 nm (closed-loop) |
| Travel Range (X/Y/Z) | 25 mm × 25 mm × 25 mm (standard) |
| Repeatability | ±0.1 µm |
| Max Load Capacity | 250 g |
| Compatibility | Standard micropipette holders (e.g., Sutter MO-103, MO-203), compatible with upright & inverted microscopes |
| Interface | Analog voltage input (±10 V), RS-232, optional USB-to-serial adapter |
| Operating Temperature | 15–30 °C |
| Humidity | 20–80% RH (non-condensing) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XenWorks |
| Pricing | Upon Request |