Other Elemental Analyzers
Filter
Showing 31–60 of 73 results
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-210A |
| Price | Upon Request |
| Measurement Range | Cl: 0.2–10,000 mg/L |
| Detection Limit | 0.1 mg/L |
| Repeatability | ≤15% (x ≤ 0.5 mg/L), ≤10% (0.5 < x ≤ 1.0 mg/L), ≤8% (1.0 < x ≤ 10 mg/L), ≤3% (x > 10 mg/L) |
| Electrolytic Cell Stability | >8 h |
| Temperature Control Range | Ambient to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Analysis Time | 1 min per sample |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-4 D |
| Pricing | Available Upon Request |
| Standard Compliance | GB/T 1792–1988 |
| Sample Form | Liquid |
| Measurement Range | ≥3 µg/g |
| Titration Method | Potentiometric Titration |
| Minimum Titration Volume | 0.01 mL |
| Potential Measurement Range | –1999.5 to +1999.5 mV |
| Burette Accuracy | ±0.1% F·S |
| Electrode Potential Resolution | 0.1 mV |
| Basic Error of Potential Unit | ±0.5 mV or ±0.1% of full scale |
| Relative Standard Deviation (RSD) | ≤5% |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | KY-4S |
| Price | Upon Request |
| Standard Compliance | GB/T 1792–1988 |
| Sample Form | Liquid |
| Measurement Range | ≥3 µg/g |
| Titration Method | Potentiometric Titration |
| Minimum Dispensed Volume | 0.01 mL |
| Potential Measurement Range | ±1999.5 mV |
| Burette Accuracy | ±0.1% F·S |
| Electronic Unit Basic Error | ±0.1% of full scale + 0.5 mV |
| Relative Error | ≤5% |
| Control Platform | Windows-based PC Interface |
| Electrode Input | Dual High-Impedance Input |
| Endpoint Detection | Automatic Potential Inflection Point Recognition |
| Fluid Handling | Automated Reagent Refill and Fixed-Volume Dispensing |
| Brand | Kyoyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | KY-200 |
| Pricing | Upon Request |
| Principle | Microcoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | S: 0.1–10,000 mg/L |
| Cl | 0.1–10,000 mg/L |
| LOD | 0.1 mg/L (S and Cl) |
| Repeatability | CV ≤3% for [S] >10 mg/L |
| Temperature Control | Ambient to 1100 °C, ±1 °C |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Cooling | Fan-cooled pyrolysis furnace (auto-start/stop) |
| Compliance | ASTM D5808, SH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208, GB/T 18612 |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | KY-214A |
| Price | Upon Request |
| Sulfur Range | 0.01–60 wt% |
| Resolution | 0.01 wt% |
| Max Sample Capacity | 24 positions |
| Avg. Analysis Time | ~5 min per sample |
| Furnace Ramp Time | 15–25 min (from ambient to setpoint) |
| Temperature Range | 700–1300 °C (user-selectable) |
| Temp. Control Accuracy | ±2.5 °C |
| Sample Mass Range | 10–999.9 mg |
| Automatic Powder Dispensing | 300 cycles per reagent box |
| Power Supply | 220 V ±20 V, 50 Hz |
| Max Instantaneous Power (Furnace) | ≤3.5 kW |
| Repeatability (St ≤1.5%) | <0.05 wt% |
| Reproducibility (St ≤1.5%) | <0.10 wt% |
| Compliance | Fully conforms to GB/T 214–2007 for total sulfur determination in coal by coulometric titration |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | KY-4 |
| Pricing | Upon Request |
| Measurement Principle | Microcoulometric Titration |
| Sample Form | Liquid |
| Method Standard | SH/T 0630-1996, SH/T 1551-2018, GB/T 11136-1989(2004), SH/T 1767-2008(2015), GB/T 1815-1997, ASTM D1492 |
| Bromine Number Range | 0–300 g Br/100 g sample |
| Bromine Index Range | 1–1000 mg Br/100 g sample |
| Accuracy | ±3% ±0.2 g Br (bromine number) |
| Detection Limit | 1 mg Br |
| Resolution | 0.01 mg Br |
| Bias Voltage Range | 0–500 mV |
| Dimensions | 280 × 280 × 160 mm |
| Power Consumption | 150 W |
| Interface | USB |
| Electrolyte | Benzene-free |
| Sample Volume | <10 mL (typical) |
| Analysis Time | ~60 seconds per sample |
| Endpoint Detection | Potentiometric |
| Brand | Kyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-200 CL |
| Pricing | Available Upon Request |
| Measurement Principle | Microcoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4 Compliant) |
| Analyte Range | S: 0.1–10,000 mg/L |
| Cl | 0.2–10,000 mg/L |
| Detection Limit | S: 0.1 mg/L |
| Cl | 0.2 mg/L |
| Repeatability | CV ≤3% (S >10 mg/L), ±0.1 mg/L (0.5–1.0 mg/L S), CV ≤8% (1–10 mg/L S) |
| Temperature Control | Ambient to 1100 °C (±1 °C) |
| Power Consumption | 1500 W |
| Gas Requirements | Industrial-grade N₂ and O₂ |
| Sample Forms | Liquid, Solid, Gas (with optional dedicated injectors) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KY-200 |
| Pricing | Available Upon Request |
| Measurement Principle | Microcoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4) |
| Analyte Forms | Total Sulfur (as SO₂), Total Chlorine (as HCl) |
| Sample Types | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | 0.1–10,000 mg/L for both S and Cl |
| LOD | 0.1 mg/L (S and Cl) |
| Repeatability | CV ≤ 3% (x > 10 mg/L) |
| Temperature Control | Ambient to 1100 °C, ±1 °C accuracy |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Cooling | Intelligent Fan-based Air Cooling |
| Power Requirement | 1500 W |
| Compliance Standards | SH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208, GB/T 18612, ASTM D5808 |
| Brand | LabTech |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | I-Lab 180 |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Measurement Principle | Potentiometric Standard Addition Method (Sodium-Selective Electrode, Non-Calibration Required) |
| Compliance | Designed for GB 28050–2011 nutritional labeling requirements |
| Software Integration | EasyDirect™ Data Acquisition Software |
| Reagent System | NaCl-based ISA (no AgNO₃ required) |
| Target Matrix | Food & Beverage samples (liquid, homogenized, or acid-digested) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPO5 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPO5 |
| Pricing | Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | NX-200S |
| Pricing | Upon Request |
| X-ray Tube | 70 kV end-window micro-focus tube |
| Detector | Imported integrated Si-PIN detector, energy resolution ≤125 eV at 5.889 keV |
| Sample Form | Dry, homogenized powder (no digestion required) |
| Detection Limits (3σ, mg/kg) | Cd 0.16 |
| Battery Life | 8–10 h per charge (removable Li-ion) |
| Operating Temperature | −20 °C to +40 °C |
| Dimensions | 260 W × 350 L × 300 H mm |
| Weight | <4.5 kg |
| Compliance | GBZ 115–2002 (X-ray safety), GB 15618–2018 (Soil Risk Control Standard) |
| Brand | AMS |
|---|---|
| Origin | Beijing, China |
| Model | NexaFlo™ |
| Configuration | Up to 14 independent analytical channels |
| Detection Principles | Continuous Flow Analysis (CFA) with segmented flow, online pre-treatment (dialysis, UV digestion, distillation, heating, dilution, mixing, extraction) |
| Detector Options | UV-Vis spectrophotometer, flame photometer (for K⁺/Na⁺), fluorimeter |
| Display | 7-inch color touchscreen (NexaFlo™ 450 variant) |
| Automation | Fully programmable CFA software with auto-startup/shutdown, QC control, auto-dilution, LIMS export, and audit-trail-capable operation |
| Compliance | Designed to support ASTM D129, ISO 11905-1, USP <621>, EPA Methods 353.2, 354.1, 365.2, and GLP/GMP-aligned data integrity practices |
| Sample Handling | Dual-probe autosampler optional |
| Fluidics | High-precision three-speed peristaltic pumps |
| Reagent Management | Integrated sealed reagent reservoirs with vapor/leak mitigation |
| Brand | NEXOPART |
|---|---|
| Origin | Germany |
| Model | HAVER CPA 2-1HR |
| Measurement Range | 20 µm – 30 mm |
| Power Supply | 230 V / 115 V, 50/60 Hz |
| Feeder Width | 55 mm |
| Camera | CMOS, 2927 px horizontal resolution, 100 MHz pixel clock |
| Light Source | LED |
| Interface | GigE Vision, USB, BUS-Extension |
| Dimensions | 810 × 200 × 400 mm (L×W×H) |
| Weight | 21 kg |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecLive |
| Detector Active Area | Up to 170 mm² |
| Maximum Quantitative Count Rate | 400 kcps |
| Maximum Mapping Count Rate | 1,000 kcps |
| Detector Type | Silicon Drift Detector (SDD) with Extreme Electronics Architecture |
| Compliance | Designed for integration with field-emission and tungsten SEM platforms per IEC 61000-4 EMC standards |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 411 |
| Pricing | Available Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Code | NJ-PFA-LXG-015 |
| Material | Perfluoroalkoxy (PFA) Resin |
| Volume | 15 mL |
| Graduation | Yes (0.5–15 mL, ±0.2 mL accuracy) |
| Max Centrifugal Force | 20,000 × g |
| Temperature Range | –200 °C to +260 °C |
| Chemical Resistance | Resistant to HF, Aqua Regia, hot conc. HNO₃/H₂SO₄, NaOH (up to 50 %), and all organic solvents |
| Autoclavable | Yes (121 °C, 20 min, 15 psi) |
| USP Class VI & FDA Compliant | Yes |
| Extractables Profile | Low metal leachables (<0.1 ppq for Al, Fe, Cr, Ni, Cu, Zn, Pb, As) |
| Brand | Qilin |
|---|---|
| Model | QL-BS3B |
| Origin | Jiangsu, China |
| Type | Benchtop Optical Emission Analyzer (Cold Light Source) |
| Measurement Principle | Photometric Colorimetry with Dual-Wavelength Compensation |
| Elements Measured | Si, Mn, P, Cr, Mo, Mg (expandable via interchangeable light sources) |
| Range | Mn 0.10–15.00%, Si 0.10–5.00%, P 0.005–0.80%, Cr 0.010–25.0%, Mo 0.010–6.00%, Mg 0.010–0.99% |
| Detection Method | Solid-state photodiode (imported silicon photovoltaic cell) |
| Calibration | Auto-zero and auto-full-scale calibration |
| Curve Storage | 15 preloaded calibration curves |
| Interface | Touch-sensitive membrane keypad with audible feedback |
| Sample Preparation | External fusion (crucible-based), no fluidic valves or tubing |
| Compliance | Designed for ISO/IEC 17025-aligned metallurgical QC labs |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Model 6020 |
| Price | Upon Request |
| Measurement Principle | Pulsed UV Fluorescence (PUVF) |
| Range | 0–50 ppb to 0–20 ppm (user-selectable) |
| Detection Limit | < 0.4 ppb |
| Noise | < 0.2 ppb |
| Zero Drift | < 0.5 ppb/24 hr |
| Accuracy | < 1% Full Scale |
| Sample Flow Rate | 0.4–0.8 L/min |
| Operating Temperature | 5–40 °C |
| Power Consumption | 200 W |
| Dimensions (H×W×D) | 133 × 432 × 571.5 mm |
| Weight | 11.3 kg |
| Display | High-resolution color TFT LCD with touchscreen support |
| Communication Interfaces | Ethernet (TCP/IP), USB 2.0, RS-232/485 |
| Analog I/O | 4 configurable voltage channels (0.1 V, 1 V, 2 V, 5 V, 10 V output ranges) |
| Digital I/O | 8 standard TTL-compatible channels |
| Data Logging | Internal non-volatile memory with timestamped records |
| Compliance | EPA Reference Method EQOA-0808-191 (equivalent to EPA Method 40 CFR Part 53, Class I) |
| Software | Menu-driven embedded OS with diagnostic suite, barcode-enabled time-series visualization, Modbus RTU/TCP support |
| Environmental Compensation | Automatic temperature and barometric pressure correction |
| Brand | Sabio |
|---|---|
| Origin | USA |
| Model | Model 6050 |
| Detection Principle | Non-Dispersive Infrared (NDIR) with Gas Filter Correlation (GFC) |
| Measurement Range | 0–200 ppm (user-selectable) |
| Resolution | 0.01 ppm |
| Units | ppm, ppb |
| Display | 7-inch high-resolution color TFT LCD (touch-enabled) |
| Communication Interfaces | Ethernet (TCP/IP), USB 2.0 (front-panel & rear), RS-232/485 |
| Analog I/O | 4-channel configurable voltage/current inputs & outputs |
| Digital I/O | 8-channel opto-isolated inputs/outputs |
| Environmental Compensation | Automatic temperature and barometric pressure compensation |
| Data Logging | Internal non-volatile memory (≥30 days at 1-min intervals) |
| Compliance | Meets EPA Method 40 CFR Part 53 reference equivalent performance criteria for CO analyzers |
| Software | Embedded menu-driven firmware with diagnostic suite, barcode-enabled time-series visualization, and remote configuration via web interface |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HG-C |
| Price | USD 1,780 (approx.) |
| Brand | SilcoTek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SilcoNert-2000 |
| Pricing | Upon Request |
| Coating Material | Hydrogenated Amorphous Silicon with Surface Alkylation |
| Deposition Method | Thermal Chemical Vapor Deposition (Non-Plasma) |
| Max Operating Temperature | 450°C (inert), 400°C (oxidizing) |
| Substrate Compatibility | Stainless Steel Alloys, Ceramics, Glass, Titanium, Specialty Metals |
| Max Dimension | 78 in (198 cm) |
| Geometry Flexibility | Full 3D Conformality |
| Thickness Range | 100–500 nm |
| Contact Angle (Hydrophobicity) | ≥65° |
| pH Stability Range | 0–8 |
| Patent Numbers | US 6,444,326 & US 6,511,760 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SMS |
| Dimensions | 300 × 500 × 190 mm |
| Weight | 3.5 kg |
| Construction | Epoxy-coated stainless steel |
| Absorption Stages | Three-stage (condensation → alkaline neutralization → activated carbon adsorption) |
| Pump Type | Recirculating water-based absorption pump (JP series) |
| Vacuum Control | Adjustable |
| Optional Accessories | Replacement activated carbon packs (A00001164), activated carbon filter cartridge (A00001165), IQ/OQ validation documentation (A00000252) |
| Brand | Sonnen |
|---|---|
| Model | T10 |
| Origin | Shanghai, China |
| Category | Other Elemental Analyzers |
| Measurement Principle | Potentiometric Titration with Silver Nitrate (AgNO₃) and Solid-State Chloride-Selective Electrode (Cl⁻-ISE) |
| Detection Limit | 0.1 mg Cl⁻ (equivalent to 0.1–5×10⁻⁵ mol/L) |
| mV Range | ±2000 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.2 mV |
| Titration Volume Resolution | 10 µL |
| Titration Accuracy | ±0.2% (at 20 mL) |
| Electrode Interfaces | 2–4 mV/pH, 2 polarizable, 2 reference |
| Dimensions (Main Unit) | 200 × 200 × 260 mm |
| Weight (Standard Configuration) | 4.3 kg |
| Data Storage | 500 test records |
| Custom Methods | 250 user-defined titration protocols |
| Connectivity | Bluetooth (up to 15 titration modules), Wi-Fi to PC |
| Display | High-brightness color touchscreen |
| Compliance | GB/T 176-2017, NY/T 1121.17-2006, GB/T 13025.5-2012, GB/T 15453-2018, GB/T 24890-2010, GB/T 14684-2001, GB/T 5009.39-2003, GB/T 5009.51-2003 |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Model | SDFCl3000 (dual-channel F/Cl) / SDF3000 (F-only) / SDCl3000 (Cl-only) |
| Measurement Range | F: 50–5000 ppm, Cl: 50–5000 ppm |
| Sample Mass | 0.5 g (typical) |
| Combustion Temperature | 1100 °C ±5 °C |
| Digestion & Collection Time | ~30 min (incl. rinse cycle) |
| Analysis Time per Solution | ~5 min (F), ~5 min (Cl) |
| Power Consumption | ≤4 kW |
| Voltage | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Dimensions (L×W×H) | 1160 × 550 × 570 mm |
| Weight | ~75 kg |
| Compliance | GB/T 3558-2014, GB/T 4633-2014 |
| Brand | Synpec |
|---|---|
| Model | SP7210 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Principle | Potassium Permanganate Titrimetric Oxidation (COD<sub>Mn</sub>) |
| Measurement Range | 0–6 mg/L as O<sub>2</sub> |
| Repeatability | RSD ≤ 2.5% |
| Sample Capacity | 54 positions |
| Digestion Time | 30 min at boiling temperature (100 °C) |
| Digestion Mode | Automated water bath with constant temperature and liquid level control |
| Titration Delivery Precision | Adjustable single-dose volume from 0.01 to 0.07 mL |
| Titration Endpoint Detection | Colorimetric endpoint recognition |
| Sample Throughput | One sample per 5 minutes |
| Sample Introduction | Three-axis robotic arm (X/Y/Z) with basket-style tray loading |
| Reagent Delivery | High-accuracy peristaltic pump for KMnO<sub>4</sub>, H<sub>2</sub>SO<sub>4</sub>, and Na<sub>2</sub>OX solutions |
| Compliance | GB 11892–1989 |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific Portable Optical Analyzer |
| Price | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TP305 |
| Pricing | Upon Request |
| Display | 5.0-inch color touchscreen LCD (Chinese interface) |
| Measurement Principle | Photometric colorimetry based on Lambert-Beer law |
| Analytical Method | National standard method using bis-cyclohexanone oxalyldihydrazone (BCO) reagent |
| Measurement Range | 0.00–200 μg/L |
| Accuracy | ±3% of full scale (F.S.) |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% |
| Stability | ±1.5% F.S. / 4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Data Storage | Cyclic memory for up to 256 measurements |
| Calibration | Blank calibration and curve calibration supported |
| Light Source | Imported monochromatic cold-light LED source |
| Circuit Design | High-integration SMT PCB architecture |
| Microcontroller | Advanced low-power single-chip microcontroller |
| Timing Function | Automatic countdown timer with audible/visual alert |
| Compliance | Aligns with Chinese national standard GB/T 12149–2019 (Industrial circulating cooling water — Determination of copper ion content by spectrophotometry) |