Other Industry Specialized Instruments
Filter
Showing 541–570 of 894 results
| Brand | Open Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LUMiKON MINI |
| Trigger Mode | Steady-State |
| Dimensions (W×H×D) | 32.5 × 37 × 20.8 cm |
| Imaging Sensor | 26 MP monochrome scientific CMOS (upgradable to 61 MP) |
| Uniformity | >95% (±5% irradiance variation across FOV) |
| Illumination Range | 0.01–1.2 suns (AM1.5G-equivalent, calibrated broadband LED source) |
| Real-Time Outputs | Quantitative PL intensity, implied Voc (iVoc), implied Fill Factor (iFF), implied Maximum Power Point (iMPP) maps |
| Spectral Capability | Optional point-scanning mode for full PL spectra (bandgap & compositional mapping) |
| Environmental Integration | Glovebox-compatible (O₂ < 0.1 ppm, H₂O < 0.1 ppm), no sample transfer required |
| Brand | ORION |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FrameScan |
| Pricing | Available Upon Request |
| Brand | ORION |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | iROBOT |
| Pricing | Available Upon Request |
| Brand | ORONTEC |
|---|---|
| Origin | Germany |
| Model | PolyShear® |
| Volume Capacity | 1 L (standard), optional 5 L configuration |
| Power Supply | 6-bar compressed air line |
| Compliance | Designed for ASTM D7193, ISO 25899, and automotive OEM process validation protocols |
| Software Interface | RS-485 / Modbus RTU, compatible with LCM wet-film colorimetric systems |
| Sensor Expansion | Optional inline viscosity, pressure, and temperature modules |
| Brand | ORONTEC |
|---|---|
| Origin | Germany |
| Model | Q-Chain LCM |
| Type | Liquid Wet-Film Color Measurement and Matching System |
| Application Scope | R&D, QC, and Production-Scale Paint & Ink Formulation |
| Measurement Principle | Reflectance Spectrophotometry on Rotating Liquid Film |
| Data Output | ΔE, Color Strength, Metamerism Index, Spectral Reflectance (360–740 nm), CIE L*a*b*, CIE XYZ, D65/2° Standard Illuminant |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BFOG |
| Pricing | Upon Request |
| [Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TQY500 |
| Price | Upon Request |
| Measurement Range | 0–40,000 Coresta |
| Resolution | 0.1 Coresta |
| Accuracy | ≤ ±2% of reading |
| Repeatability | ≤ ±1% of reading |
| Test Area | 2 cm² |
| Adjustable Test Spacing | 0–999 mm |
| Max Test Count | 5,000 cycles |
| Avg. Test Time | 5 s per point |
| Air Supply | 0.5–0.7 MPa, oil-free, water-free, particle-free |
| Dimensions | 540 × 500 × 300 mm |
| Weight | 33 kg |
| Compliance | GB/T 23227, GB/T 12655, ISO 2965:2009, JJG(Tobacco) 08–2014] |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Parma |
| Price | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NPS-20 |
| Pricing | Available Upon Request |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | F1-25 |
| Application | Educational Hydraulics & Turbomachinery Laboratory Equipment |
| Enclosure | Cast Housing with Transparent Observation Panel |
| Torque Measurement | Spring-Balanced Mechanical Dynamometer |
| Pressure Indication | Remote Bourdon-Tube or Digital Pressure Gauge |
| Speed Measurement | Optional Non-Contact Tachometer (100–2000 rpm range) |
| Load Control | Calibrated Weights for Pelton Injector Needle Actuation |
| Software Option | Armfield Educational Software Suite (Data Logging, Real-Time Plotting, Efficiency Calculation) |
| Brand | PerfecLight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GC7980 |
| Pricing | Upon Request |
| Column Oven | 8-Step Programmable Temperature Ramp |
| Temperature Control Zones | 6 Independent Zones (Including Oven, Injector, Detector(s), etc.) |
| Control Functions | Memory Storage, Self-Diagnosis, Time-Based Event Programming |
| Detector Options | TCD (Thermal Conductivity Detector) with Automatic Carrier-Gas Failure Protection |
| TCD Max Operating Temp | 400 °C |
| TCD Absolute Temp Accuracy | ±0.5% of Setpoint |
| TCD Sensitivity (S) | ≥2500 mV·mL/mg (n-Hexadecane) |
| TCD Baseline Noise | ≤20 µV |
| TCD Drift | ≤100 µV / 15 min |
| TCD Dynamic Range | ≥10⁶ |
| FID (Flame Ionization Detector) | Auto-Ignition via Host or Workstation Control |
| FID Max Operating Temp | 400 °C |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-Hexadecane) |
| FID Baseline Noise | ≤2×10⁻¹³ A |
| FID Baseline Drift | ≤5×10⁻¹³ A (30 min, after 150 min warm-up) |
| Software | Fully Remote-Controlled Chromatography Data System (CDS) |
| Injector Options | Packed-Column Injector |
| Optional Accessories | Modular Nickel Methanizer |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | HF |
| Pricing | Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ACP 15, ACP 28, ACP 40 |
| Ultimate Pressure (with gas ballast) | ≤ 0.1 mbar |
| Pumping Speed | 14–37 m³/h |
| Max. Water Vapor Handling Capacity | 1000 g/h |
| Gas Ballast Flow Rate | > 2 Nm³/h (at 1 bar abs) |
| Leak Rate (He) | < 5 × 10⁻⁷ mbar·L/s |
| Weight | 23–32 kg |
| Certifications | CE, UL/CSA, SEMI S2 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PNL |
| Pricing | Available Upon Request |
| Brand | CK |
|---|---|
| Origin | Austria |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | PhotoMAX |
| Pricing | Upon Request |
| Brand | Zealquest AI Netherlands |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | Zealquest-AI SMR-POM |
| Quotation | Available upon Request |
| Dimensions (L×W×H) | <1400 × 900 × 1640 mm |
| Curb Weight | 400 kg |
| Mobility System | All-terrain 8-wheel planetary swing chassis, 4-wheel drive |
| Max Speed | 5 km/h |
| Obstacle Clearance | 200 mm |
| Trench Crossing Width | 500 mm |
| Climbing Angle | 25° |
| Turning Diameter (under load) | ≤3.2 m |
| Control Modes | Wireless remote control + autonomous navigation |
| Battery Endurance | ≥6 h |
| Video/Data Transmission Range | >500 m |
| Waterproof Depth Rating | 300 mm |
| Payload Capacity | 100 kg |
| Ingress Protection | IP65 |
| Visible-light Camera | 2560 × 1440 resolution, 5–160 mm motorized zoom lens |
| Thermal Imaging Camera | 384 × 288 resolution, 7–25 mm focal length (fixed-focus optional) |
| Pan-Tilt Unit | 360° horizontal rotation, −90° to +90° vertical tilt |
| Optional Modules | Autonomous obstacle avoidance, remote teleoperation, intelligent follow-mode, robotic weeding system, environmental sensor suite (e.g., irradiance, wind speed, ambient temperature/humidity), telescopic mast, smart handheld terminal, wireless bridge, automated charging station |
| Key | Brand: PILOTECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CE-30 |
| Heating Method | Thermal Oil |
| Max Throughput | 30 L/h |
| Construction Material | 316L Stainless Steel (Wetted Parts) |
| Compliance | GMP-Compliant Design |
| Operation Mode | Continuous, Fully Enclosed Vacuum System |
| Brand | Pixience |
|---|---|
| Origin | France |
| Model | C-Cube |
| Import Status | Imported |
| Distribution Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | Plasma-Therm |
|---|---|
| Origin | USA |
| Equipment Type | PECVD / HDPCVD / RIE / ICP / DSE |
| Wafer Size Support | 2″ to 12″ |
| Automation Levels | Manual / Semi-Automatic / Full Cassette-to-Cassette Automation |
| Installed Base | >1,600 Systems Worldwide |
| Uniformity (PECVD) | ≤3% (1σ, across wafer) |
| Chamber Heating | Fully Ceramic-Encapsulated Uniform Thermal Control |
| Endpoint Detection | Real-Time Optical Emission Spectroscopy (OES) with Sub-Second Response |
| Gas Switching Speed | <500 ms (Patented Rapid Valve Architecture) |
| Pressure Control Resolution | ±0.01 mTorr (Patented Closed-Loop Digital Manifold) |
| Brand | Rofin |
|---|---|
| Origin | Australia |
| Model | PL550XL |
| Lamp Type | 500 W Xenon Arc |
| Input Voltage | 85–265 VAC, 50–60 Hz auto-sensing |
| Optical Output | UV–Visible Liquid Light Guide (2 m standard), optional IR Liquid Light Guide (2 m) with IR bandpass filters (>610 nm, >715 nm, >780 nm, >830 nm) |
| Wavelength Selection | Blank, White, 350 nm, 415 nm, 450 nm, 470 nm, 490 nm, 505 nm, 530 nm, 555 nm, 590 nm, 620 nm, 650 nm |
| Power Settings | P1–P8 continuous |
| User Interface | Three rotary dials (wavelength, power, fine adjustment), LED display, three programmable memory buttons, intelligent standby/power button, integrated light guide mounting points |
| Cooling System | Microprocessor-controlled variable-speed fan |
| Compliance | Designed for forensic laboratory environments compliant with ISO/IEC 17025 documentation practices and compatible with GLP/GMP audit trail requirements in evidence handling workflows |
| Standard Accessories | Camera filter set (OG475, OG515, OG550, OG590), high-pass camera adapters, 52/58 mm & 49/58 mm step-up rings, amber/red/neutral/yellow protective eyewear |
| Brand | POLOS |
|---|---|
| Origin | Germany |
| Model | SPIN150i |
| Maximum Substrate Diameter | 150 mm (round) / 150×150 mm (square) |
| Rotation Speed Range | 0–12,000 rpm (±0.1 rpm accuracy) |
| Acceleration/Deceleration | 1–30,000 rpm/sec (adjustable in steps) |
| Rotation Modes | Programmable CW, CCW, and oscillatory stirring |
| Safety | Sensor-interlocked automatic lid lock |
| Standard Chuck | Vacuum chuck A-V36 + fragment adapter D-V10 |
| Housing Material | NPP (standard), optional PTFE version |
| Control Interface | Removable full-color touchscreen with intuitive recipe programming and storage |
| Optional Modules | Multi-nozzle dispensing (up to 6 independently programmable nozzles), ultrasonic cleaning, sequential/parallel chemical delivery |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CFC |
| Type | Cross-Fractionation Chromatography System |
| Application | Polyolefin Microstructure Characterization |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CFC Instrument for Polymerization Process Optimization Analysis |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFC Microstructural Differentiation Analyzer |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EFS |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR Advanced |
| Application | Simultaneous Quantification of Xylene Solubles, Ethylene Content, and Intrinsic Viscosity in Impact Polypropylene |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR5 |
| Temperature Range | 160 °C (max) |
| Detection | Dual IR5 Infrared Detectors (CH₂/CH₃ channels) |
| Columns | PL-PEG 10⁶–10⁷ Da & HT-Mixed-B for UHMW polyolefins |
| Solvent Compatibility | 1,2,4-Trichlorobenzene (TCB) |
| Flow Rate | 0.5–1.0 mL/min |
| Calibration Standards | Narrow-distribution polyethylene standards (NIST-traceable) |
| Software | Cirrus GPC/SEC v5.x with ASTM D6474 & ISO 16014-4 compliant reporting |
| Data Security | FDA 21 CFR Part 11–ready audit trail, electronic signatures, and user access levels |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GPC-IR5 |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | HT-GPC System for Molecular Weight, Long-Chain Branching (LCB), and Short-Chain Branching (SCB) Distribution Analysis |
| Detection Modes | Infrared (IR5), Differential Viscometry, Composition-Sensitive Detection |
| Temperature Range | Up to 160 °C |
| Solvent Compatibility | 1,2,4-Trichlorobenzene (TCB), ODCB |
| Calibration Standards | Narrow-MWD PE/PP Reference Standards |
| Data Output | Mw, Mn, Mz, Đ, LCB frequency (λ), SCB density (branches/1000C), Branch Length Distribution, Compositional Heterogeneity Index (CHI) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | Microstructural Differentiation Analyzer for Polyolefin Films and Fish-Eye Defects |
| Application Domain | Polyolefin Film Quality Control & Defect Root-Cause Analysis |
| Compliance Framework | ASTM D1238, ISO 1133, ISO 1628-1, ISO 15270, USP <1058> Analytical Instrument Qualification |
