Other Industry Specialized Instruments
Filter
Showing 811–840 of 892 results
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HMAS-C1000SZA |
| Optical System | High-Precision Triple-Port Microscopy with Dual Measurement Pathways |
| Turret Mechanism | Motorized Turret with Precision Z-Axis Elevation |
| Test Forces | 8-step selectable (0.098–9.807 N / 10–1000 gf) |
| Hardness Scales | HV0.01 to HV1 |
| Compliance | GB/T 4340.1–2009 |
| X-Y Stage Travel | 25 × 25 mm (optional 50 × 50 mm), Repeatability: ±2 µm |
| Max Specimen Height | 130 mm |
| Depth from Indenter to Chamber Wall | 170 mm |
| Magnification | 100× (observation), 400× (optical measurement), ~1500× (digital image analysis) |
| Minimum Resolution | 0.025 µm |
| Dwell Time | 1–60 s (1 s increments) |
| Specimen Stage Size | 140 × 180 mm |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 46.0 kg |
| Gross Weight | 61.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HV-10 |
| Test Force Range | 0.2–50 kgf (1.96–490.3 N) |
| Loading Method | Fully Automatic (Load–Hold–Unload) |
| Standard Compliance | GB/T 4340, ISO 6507 |
| Measuring Resolution | 0.06 µm (at 20× objective), 0.12 µm (at 10× objective) |
| Max Specimen Height | 235 mm |
| Depth from Indenter to Chamber Wall | 130 mm |
| Optical System | Dual-Magnification (10× observation / 20× measurement for 5–10 kgf |
| Total Magnification | 100× (observation), 200× (measurement) |
| Hold Time Range | 0–60 s (1 s increments) |
| Display | LCD with real-time force indication |
| Hardness Range | 8–3000 HV |
| Conversion Support | HV ↔ HK ↔ HRC ↔ HB ↔ HRB (per ASTM E140) |
| Construction | One-piece cast aluminum housing with automotive-grade baked enamel finish |
| Net Weight | 46.0 kg |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Power Supply | AC 220 V / 50 Hz |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HV-30 |
| Test Force Range | 0.2–50 kgf (1.96–490.3 N) |
| Loading Method | Fully Automatic (Load-Hold-Unload) |
| Standards Compliance | GB/T 4340, ISO 6507 |
| Measuring Resolution | 0.06 µm (with 20× objective), 0.12 µm (with 10× objective) |
| Max Specimen Height | 235 mm |
| Distance from Indenter to Chamber Wall | 130 mm |
| Optical System | Dual-magnification turret (10× observation / 20× measurement for 5–10 kgf |
| Total Magnification | 100× (observation), 200× (measurement) |
| Hold Time Adjustment | 0–60 s (1 s increments) |
| Display | LCD with real-time force indication |
| Hardness Range | 8–3000 HV |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 46.0 kg |
| Software Integration | Optional PC-based analysis module with hardness conversion tables and GLP-compliant data logging |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HV-5 |
| Test Force Range | 0.2–50 kgf (1.96–490.3 N) |
| Hardness Range | 8–3000 HV |
| Minimum Detection | 0.06 µm (at 20× objective) |
| Standards Compliance | GB/T 4340, ISO 6507 |
| Loading Method | Fully Automatic (Load-Hold-Unload) |
| Hold Time | 0–60 s (1 s increments) |
| Max Specimen Height | 235 mm |
| Depth from Indenter to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 46.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HV-50 |
| Test Force Range | 0.2–50 kgf (1.96–490.3 N) |
| Loading Method | Fully Automatic (Load–Hold–Unload) |
| Standards Compliance | GB/T 4340, ISO 6507 |
| Measuring Resolution | 0.06 µm (with 20× objective), 0.12 µm (with 10× objective) |
| Max Specimen Height | 235 mm |
| Distance from Indenter to Chamber Wall | 130 mm |
| Optical System | Dual-Magnification (10× observation / 20× measurement for 5–10 kgf |
| Total Magnification | 100× (observation), 200× (measurement) |
| Hold Time Range | 0–60 s (1 s increments) |
| Display | LCD with real-time test force and hardness value |
| Hardness Range | 8–3000 HV |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 46.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MC030-MCE200X2 |
| Price Range | USD 7,000 – 12,600 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MC030-WF100-10800 |
| Price Range | USD 7,000 – 14,000 |
| Angular Resolution | 0.0001 arcsec (optional configuration) |
| Measurement Axes | X and Y simultaneous |
| Sensor Type | High-resolution CMOS image sensor |
| Data Processing | Real-time digital image analysis engine |
| Compliance | ISO 10110-5, ISO 21096, GB/T 22043–2008 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MC030-WF100-6000 |
| Price Range | USD 2,800 – 5,600 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MC030-WF200-5700 |
| Price Range | USD 11,200 – 16,800 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MC030-ZJHS200-200HZ |
| Price Range | USD 5,600 – 12,700 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MC030-ZJPX200-2350HZ |
| Price Range | USD 7,000 – 28,000 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MC030-ZJPX300-2350HZ |
| Price Range | USD 7,000 – 28,000 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MC030-ZJUH3000 |
| Price Range | USD 2,800 – 14,000 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MC030-ZJUH3000/0.1 |
| Angular Resolution | 0.1 arcsecond |
| Measurement Axes | X and Y (simultaneous) |
| Sensor Type | High-Resolution CMOS Imaging Array |
| Data Processing | Real-Time Digital Image Analysis Algorithm |
| Compliance | ISO 10110-7, GB/T 22168–2008, JJG 924–2018 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MC030-ZJUH3000/0.2 |
| Angular Resolution | 0.2 arcseconds |
| Measurement Range | ±1500 arcseconds (X & Y axes, simultaneous) |
| Sensor | High-resolution CMOS imaging sensor |
| Output Interface | USB 3.0 / RS-232 |
| Compliance | ISO 10110-5, GB/T 22576–2017 (Optical Testing Standards) |
| Operating Temperature | 15–25 °C |
| Repeatability | ≤0.1 arcsecond (2σ, under controlled lab conditions) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MC030-ZJUH3000/0.3 |
| Angular Resolution | 0.3 arcseconds |
| Measurement Range | ±1500 arcseconds (X & Y axes, simultaneous) |
| Sensor | High-resolution CMOS imaging sensor |
| Output Interface | USB 3.0 / RS-232 / Ethernet |
| Compliance | ISO 10110-5, GB/T 22547-2008, JJG 925-2019 |
| Operating Temperature | 15–25 °C (±1 °C/h stability recommended) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.255 |
| Compliance | UL-1581 |
| Application | Specimen Preparation for Tensile Testing of Wire Insulation and Jacketing Materials |
| Type | Precision Rotary Abrasive Grinding System |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.510 |
| Compliance | JIS K 5101, JIS K 5400 |
| Application Principle | Eccentric gap control mechanism |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.519 |
| Standard Compliance | JIS K 6894 |
| Test Method | Spiral Scribe Adhesion Test |
| Load Application | Fixed Dead-Weight Loading |
| Stroke Pattern | Concentric Spiral (25 revolutions) |
| Evaluation Basis | Visual Comparison Against JIS Reference Charts |
| Sample Substrate | Metallic Panels with Fluoropolymer Coatings |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.527/547 |
| Standards Compliance | JIS K5101, JIS K5400, JIS K5600-2-5, JIS K5701-1, ASTM D1210, ISO 1524 |
| Measurement Principle | Mechanical groove-depth-based particle visibility detection |
| Groove Depth Range | 0–100 µm (typical linear scale) |
| Scale Resolution | 2.5 µm per division (standard JIS/ASTM scale) |
| Material | Hardened stainless steel body with precision-ground stainless steel groove plate |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.542-AB |
| Compliance Standards | JIS K 5101, JIS K 5400, ASTM D823 |
| Operation Principle | Vacuum-assisted, motor-driven drawdown with precision gap control |
| Substrate Fixation | Vacuum suction through perforated platen |
| Coating Method | Fixed-gap bar coating (compatible with wire-wound rods and adjustable applicator bars) |
| Drive System | Stepper motor with constant linear speed control |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.542-AB-H |
| Compliance Standards | JIS K5101, JIS K5400, ASTM D823 |
| Heating Plate Function | Yes |
| Vacuum-Assisted Substrate Fixation | Yes |
| Substrate Compatibility | Coated paper, plastic films, foils |
| Application Method | Adjustable-speed draw-down bar coating |
| Supplier Type | Authorized Distributor (Imported Equipment) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.546 |
| Compliance | JIS K 5101 |
| Operating Principle | Vacuum-assisted dual-glass-disc mulling under controlled load and rotation |
| Sample Handling | Manual loading, fully automated grinding cycle |
| Drive System | Precision stepper motor with programmable speed and dwell time |
| Vacuum System | Integrated vacuum pump (≤10 kPa absolute) for air removal during dispersion |
| Disc Material | Optical-grade ground glass (φ150 mm, parallelism ±2 µm) |
| Load Application | Pneumatically actuated vertical force (adjustable 0–200 N) |
| Cycle Control | Fully programmable sequence (grinding time, rest intervals, lift/lower timing) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.551-AUTO-1 |
| Test Standards | JIS D 0202, JIS K 5400, JIS K 5600-5-6, ASTM D2197, ISO 2409 |
| Sample Stage | 90 × 90 mm, 90° automatic rotation |
| Max. Travel | 50 mm (X), 50 mm (Y) |
| Cut Spacing | 0.5 / 1.0 / 1.5 / 2.0 mm (4-step selection) |
| Cutting Speed | 5 / 10 / 15 / 20 mm/s |
| Number of Cuts | Programmable via timer (standard: 6 or 11 cuts) |
| Load Range | 10–350 gf (counterweight-based) |
| Cutting Needle | φ3 mm diameter, 23 mm length, 60° tip angle |
| Power Supply | AC 100 V, 1-phase, 5 A, 50/60 Hz |
| Dimensions (w/o guard) | 630 × 750 × 700 mm |
| Weight | ~90 kg |
| Dimensions (with guard) | 630 × 750 × 760 mm |
| Weight | ~95 kg |
| Optional Accessories | Electrical continuity module, blade mounting jig, linear displacement sensor |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.553-M |
| Test Angle | 45° (60° for enameled wire) |
| Stroke Range | Horizontal ≤100 mm, Vertical ≤50 mm |
| Scratching Speed | 0.5–1 mm/s (motor-driven, continuously adjustable) |
| Load Capacity | Up to 1 kgf (beam balance type) |
| Test Table Dimensions | M-1: 100 × 180 mm |
| M-2 | 150 × 180 mm |
| Accessories Included | Mitsubishi Uni pencils (6B–9H, 17 pcs), steel stylus (1 pc), dedicated pencil sharpener, #400 abrasive paper, spirit level |
| Optional Accessories | Heated stage, electrical continuity module, φ3 mm × 23 mm conical stylus (60° tip angle) |
| Power Supply | AC 100 V, single-phase, 3 A, 50/60 Hz |
| Dimensions & Weight | M-1: ~440 × 200 × 440 mm, ~20 kg |
| M-2 | ~440 × 260 × 440 mm, ~27 kg |
| Compliance Standards | JIS C3003, JIS K5400, JIS K5600-5-4, JIS K5651, JIS K6894, JIS K6902, ASTM D2197, ASTM D3363, ISO 15184, GB/T 6739 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yoke Instrument Co., Ltd. |
| Type | Domestic Benchtop Photometric Analyzer |
| Model | YK-YW5 |
| Pricing | Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HWP34-10S |
| Price | Upon Request |
| Operating Environment | (-5–45)°C, <95% RH |
| Heating Rate | (3.5 ± 0.3) K/s |
| Vessel Internal Dimensions | Φ50 mm × 94.5 mm |
| Vessel Material | 316 Stainless Steel |
| Burst Disc Material | Aluminum Plate, Ø38 mm |
| Burst Pressure | 620 ± 60 kPa @ 22°C |
| Orifice Plate Diameters | 1.0, 2.0, 3.5, 6.0, 9.0, 12.0, 16.0, 24.0 mm |
| Orifice Plate Thickness | 2.0 ± 0.2 mm |
| Temperature Resolution | ±0.1°C |
| Temperature Sensor Response Time | 0.5 s |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MITC-1000A |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | ≤20 min (ambient to 500 °C) |
| Temperature Stability | ±5.0 °C |
| Temperature Accuracy | ±3.0 °C |
| Temperature Precision | ±0.1 °C |
| Powder Dispersion Pressure | 0–100 kPa (±5% accuracy) |
| Gas Reservoir Volume | 500 mL |
| Ambient Temp. Sensing | −10 °C to +60 °C |
| Ambient Humidity Sensing | 5–95% RH |
| Power Supply | 220 VAC / 50 Hz |
| Power Consumption | 2600 W |
| Dimensions | 670 mm × 400 mm × 590 mm |
| Display | 7-inch color TFT touchscreen |
| Interface | Dual USB 2.0 ports |
| Compliance Standards | ASTM E1491-06, EN 50281-2-1, GB/T 16429, IEC 61241-2, ISO/IEC 80079-20-2 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MITL-450A |
| Temperature Range | Ambient to 450 °C |
| Heating Plate Diameter | 200 mm |
| Dust Layer Height Options | 5 mm / 12.5 mm / 15 mm |
| Temperature Uniformity | ±5.0 °C |
| Temperature Stability | ±3.0 °C |
| Temperature Accuracy | ±3.0 °C |
| Temperature Precision | ±0.1 °C |
| Ramp Time | ≤40 min (ambient to 350 °C) |
| Ambient Sensor Range | –10 °C to +60 °C / 5–95% RH |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | 2800 W |
| Dimensions | 670 mm × 400 mm × 390 mm |
| Interface | Dual USB 2.0 |
| Display | 7-inch color TFT touchscreen |