| Brand | Labthink |
|---|---|
| Model | FT-F1 |
| Temperature Range (Hot Chamber) | Ambient to 150 °C (up to 280 °C optional) |
| Temperature Stability (Hot Chamber) | ±0.1 °C at 150 °C |
| Temperature Range (Cold Chamber) | 0–100 °C |
| Temperature Stability (Cold Chamber) | ±0.1 °C |
| Compliance | ISO 6452, DIN 75201, SAE J1756, QB/T 2728, BS EN 14288, PV 3920, PV 3015, ES-X83231, NES M0161, D45 1727, GM 9305P, TSM 0503G |
| Measurement Methods | Gloss Reduction (standard), Haze Increase (optional), Gravimetric Condensate Mass (standard, balance not included) |
| Brand | Labthink |
|---|---|
| Model | FT-F1 Fogging Tester |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| High-Temperature Bath Range | Ambient to 150 °C (up to 280 °C optional) |
| High-Temperature Stability | ±0.1 °C at 150 °C |
| Low-Temperature Bath Range | 0–100 °C |
| Low-Temperature Stability | ±0.1 °C |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink |
| Model | FT-F1 |
| High-Temperature Bath Range | Ambient to 150 °C |
| High-Temperature Stability | ±0.1 °C at 150 °C |
| Low-Temperature Bath Range | 0–100 °C |
| Low-Temperature Stability | ±0.1 °C |
| Brand | Labthink |
|---|---|
| Model | FT-F1 |
| Origin | Shandong, China |
| Manufacturer | Jinan Labthink Electromechanical Technology Co., Ltd. |
| High-Temperature Bath Range | Ambient to 150 °C (up to 280 °C optional) |
| High-Temperature Stability | ±0.1 °C at 150 °C |
| Low-Temperature Bath Range | 0–100 °C |
| Low-Temperature Stability | ±0.1 °C |
| Brand | Labthink |
|---|---|
| Model | RT-01 |
| Standard Compliance | ASTM D5264, TAPPI T830 |
| Applied Load | 8.9 N (2 lb) and 17.8 N (4 lb) |
| Oscillation Frequency | 21, 42, 85, 106 cycles per minute (cpm) |
| Motion Profile | Arcuate reciprocating motion |
| Cycle Count Range | 0–999,999 |
| Sample Capacity | 1–2 specimens |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 485 × 390 × 230 mm |
| Net Weight | 40 kg |
| Control System | Microprocessor-based with PVC membrane keypad and LCD display |
| Test Modes | Dry abrasion, wet abrasion, migration, and wet trace |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 8400 Series |
| Magnetic Field Range | Up to 2.23 T (DC), 1.44 T (AC, 50 mm gap) |
| Temperature Range | 10 K–1273 K (with optional cryostats/furnaces) |
| Mobility Range | 1×10⁻³ to 1×10⁶ cm²/V·s (AC/DC) |
| Resistivity Range | 1×10⁻⁵ to 1×10⁵ Ω·cm |
| Standard Resistance Range | 0.5 mΩ–10 MΩ |
| High-Resistance Option | up to 200 GΩ |
| Low-Resistance Option | down to ~0.5 µΩ |
| AC Frequencies | 0.05 Hz and 0.1 Hz |
| Sample Geometry Support | Van der Pauw, Hall bar, 4-point probe |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | FastHall Station |
| Pricing | Upon Request |
| Magnetic Field | 1 T (RT), 0.75 T (77 K) |
| Temperature Options | Room Temperature & Optional Liquid Nitrogen Cooling (77 K) |
| Resistance Range | 10 mΩ to 1 GΩ |
| Mobility Range | 0.01–10⁶ cm²/V·s |
| Resistivity Range | 1×10⁻⁵ to 10⁵ Ω·cm (typ.) |
| Carrier Concentration | 8×10² to 8×10²³ cm⁻³ (typ.) |
| Measurement Speed | <10 s per sample (typ.) |
| Sample Formats | Solder card (10×10×3 mm), Pin card (10×10×2 mm) |
| Hall Method | FastHall™ (field-reversal-free) and Van der Pauw / Hall bar configurations |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | M91 |
| Measurement Principle | FastHall™ (patented single-direction magnetic field Hall effect analysis) |
| Compliance | ASTM F76, ISO/IEC 17025-compatible operation |
| Software Interface | LakeSHORE HallScan™ v3.2 with 21 CFR Part 11 audit trail support |
| Standard Resistance Range | 10 mΩ to 10 MΩ |
| Extended Range (with M9-ADD-HR option) | 10 mΩ to 200 GΩ |
| Carrier Mobility Range | 0.001–1×10⁶ cm²/(V·s) |
| Sample Configurations | Van der Pauw, Hall bar, cloverleaf |
| Magnetic Field Compatibility | DC fields up to ±16 T (superconducting magnet-ready) |
| Thermal Drift Mitigation | Sub-50 ms measurement window, active thermal compensation algorithm |
| Data Output Format | CSV, HDF5, XML |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MCS |
| Instrument Type | Variable-Temperature Hall Effect Tester |
| Constant Current Source Range | 1–20 mA |
| Mobility Range | 0.01–10⁶ cm²/V·s |
| Resistivity Range | 1×10⁻⁵ – 1×10⁵ Ω·cm |
| Carrier Concentration Range | 8×10² – 8×10²³ cm⁻³ |
| Typical Measurement Time | <10 s |
| Magnetic Field | 1 T (RT), 0.75 T (77 K) |
| Sample Dimensions (Max) | 10 mm × 10 mm × 3 mm (Solder Card) |
| Brand | Laman Optics |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 71S0503A-LED |
| Price Range | USD $14,000 – $35,000 (FOB Guangdong) |
| Illumination Mode | Steady-State Operation |
| Spectral Range | 400–1100 nm |
| Spectral Match Class | A+ (0.875–1.125 per IEC 60904-9 Ed. 3) |
| Spatial Uniformity | ≤ ±2% (Class A) |
| Temporal Stability | ≤ ±2% over 1 h (Class A) |
| Beam Diameter | Ø70 mm |
| Light Source Lifetime | ≥100,000 h (at rated output) |
| Rated Power Consumption | 650 W |
| Warm-up Time to Stability | ≤15 min |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | DC1500-UDV |
| Wavelength | 568 nm |
| Wavelength Accuracy | ±2% FS |
| Bandwidth | 10 nm |
| Photometric Range | –2 to +2 AU |
| Photometric Accuracy | ±0.005 AU (at 1.0 AU) |
| Photometric Precision | ±0.001 AU (at 1.0 AU) |
| Display | 160 × 100 backlit LCD with 20 × 6 alphanumeric/graphic capability |
| Sample Cell | 10 mm square cuvette compatible |
| Detector | Silicon photodiode with integrated interference filter |
| Power | Rechargeable 3.7 V Li-ion battery, USB or AC adapter |
| Ingress Protection | IP67 |
| Compliance | CE marked |
| Interface | Mini-USB |
| Auto-off | Configurable (5 / 10 / 30 min idle) |
| Language Support | English, Chinese, Spanish, French, German, Italian, Portuguese |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | LKB-MF |
| Temperature Range (Bath A) | 0–50°C |
| Temperature Range (Bath B) | 5–80°C |
| Temperature Stability | ≤ ±0.5°C |
| Temperature Uniformity | ≤ ±0.1°C |
| Circulating Pump Flow Rate | >8 L/min |
| Heating Power | 1000 W |
| Chamber Dimensions | 150 × 200 × 200 mm × 2 independent baths |
| Construction | Stainless steel inner tank, electrostatically sprayed steel outer shell, fiberglass insulation |
| Cooling System | Air-cooled, hermetically sealed compressor unit |
| Display Resolution | 0.1°C |
| External Circulation Capability | Yes |
| Compliance | GB/T 24970–2010 |
| Brand | Langzauner |
|---|---|
| Origin | Austria |
| Model | Langzauner Series |
| Drive Type | Servo-controlled hydraulic |
| Pressure Range | 1.5–3,000 metric tons |
| Positional Accuracy | ±0.05 mm |
| Pressure Accuracy | ±1% of full scale |
| Platen Flatness Tolerance | ±0.1 mm |
| Temperature Sensor Inputs | 4 channels |
| Energy Savings vs. Conventional Proportional Systems | >70% |
| Noise Level | Optimized to minimum operational dB(A) |
| Compliance | Designed for ISO 9001-aligned manufacturing environments and GLP-compliant laboratory integration |
| Brand | Lanjing |
|---|---|
| Model | LJ-WH1000 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price | USD 8,400 (approx.) |
| Spectral Bands | 6-band configurable (RGB + narrowband green @ 550±10 nm, red @ 650±10 nm, NIR @ 850±10 nm) |
| Sensor | CMOS, 5 MP native resolution |
| Lens | 6–12 mm focal length, FOV 60°–120° |
| Storage | 16 GB internal (expandable to 128 GB) |
| Connectivity | Ethernet, Wi-Fi, 4G LTE |
| Power | Sleep mode 0.9 W (180 mA), operational 4.5–7 W (900–1400 mA) |
| Operating Temp | −40 °C to +60 °C |
| Humidity Range | 0–100 % RH |
| IP Rating | IP67 |
| Dimensions | 150 × 150 × 150 mm |
| Weight | 500 g (including mounting platform and bracket) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LAwave |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LBIC |
| Price Range | USD 140,000 – 280,000 |
| Measurement Mode | AC-coupled photocurrent detection |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC-100 |
| Pricing | Upon Request |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | HCS L36 |
| Instrument Type | Ambient-Temperature Hall Effect Tester |
| Constant Current Source Range | DC: 1 nA–125 mA (8 decades, ±12 V compatible) |
| AC | 16 µA–20 mA, input impedance > 100 GΩ, frequency range 1 mHz–100 kHz |
| Voltage Measurement | DC low-noise/low-offset: 1 µV–2500 mV, 4 gain ranges, digital resolution 300 pV |
| AC | 20 nV–1 V, adjustable integration time and gain |
| Mobility Range | 10⁻³–10⁷ cm²·V⁻¹·s⁻¹ |
| Resistivity Range | 10⁻⁴–10⁷ Ω·cm |
| Carrier Concentration Range | 10⁷–10²² cm⁻³ |
| Brand | RINNTECH |
|---|---|
| Origin | Germany |
| Configuration | Manual crank operation (motorized option available) |
| Standard Measurement Length | 560 mm (optional range: 200–2000 mm) |
| Standard Resolution | 0.01 mm (optional: 0.005 mm, 0.0025 mm, 0.001 mm) |
| Standard Sensitivity (per ring displacement) | 5 mm (optional: 2.5 mm, 10 mm) |
| Maximum Sample Weight | 50 kg |
| Interface | RS-232 serial port |
| Enclosure | IP54-rated splash-resistant housing |
| Calibration | Internal, self-contained, no external reference required |
| Brand | Little Joe |
|---|---|
| Origin | USA |
| Model | H Series (Single-Color) / HD Series (Dual-Color) |
| Dimensions (H) | 92 × 31 × 28 cm |
| Plate Area | 10 × 20 cm |
| Substrate Size (H) | 23 × 30 cm |
| Dimensions (HD) | 138 × 31 × 28 cm |
| Substrate Size (HD) | 23 × 31 cm |
| Brand | Quantum Design |
|---|---|
| Origin | Germany |
| Manufacturer | LOT-Oriel Group (a Quantum Design Company) |
| Type | LOT Series |
| Illumination Mode | Steady-State |
| Light Source | 300 W Short-Arc Xenon Lamp (Ozone-Free) |
| Spectral Match Class | ASTM E927 Class B |
| Irradiance Instability | ≤1% RMS (typ.) |
| Output | Fiber-Coupled |
| Optional Filters | AM1.5G or AM0 |
| Optional Shutter | Digital or Manual Mechanical/Electronic |
| Optional Add-on | VSM-FOSH Photomagnetic Measurement Kit with Monochromatic Light Source (MLS), 360–845 nm, 150 W Xenon Lamp, UV-Vis-NIR Fiber Delivery (D320-UV: 325–900 nm |
| D320-IR | 375–2250 nm), Max Sample Diameter: 1.6 mm, Magnetic Sensitivity: <1×10⁻⁴ emu |
| Brand | LiveStrong |
|---|---|
| Model | LSQE-R |
| Origin | Taiwan |
| Instrument Type | Spectral Response & Quantum Efficiency Test System |
| Measurement Principle | AC-coupled Lock-in Amplification with Monochromatic Excitation |
| Wavelength Range | 300–1100 nm (standard), optional extensions to 200–3000 nm |
| Optical Resolution | <0.01 nm (Czerny-Turner monochromator, multi-grating) |
| Stray Light | <1×10⁻⁵ |
| Spot Size | ~100 µm (with microscope module, adjustable/customizable) |
| Frequency Range | 4 Hz–2 MHz (three selectable bands: 4–200 Hz, 20–2000 kHz, 200–10 kHz) |
| Frequency Resolution | 0.01 Hz |
| Current Sensitivity | 10 fA (AC mode, RMS) |
| Measurement Modes | AC, DC, AC+DC with bias voltage, polarized light collection |
| Compliance | IEC 60904-8, ASTM E1021, ASTM E2848 |
| Key Functions | EQE, IQE, IPCE, spectral responsivity, reflectance, transmittance, Jsc calculation per wavelength, bandgap estimation |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | ARS31Pro-UMB |
| Measurement Principle | Peltier-based active cooling/heating with NTC surface temperature sensing |
| Ice Detection Method | Real-time dew/frost point and freezing point calculation independent of de-icing agents |
| Mounting | Flush-mounted, modular electronics unit |
| Output | Binary ice warning + analog/digital surface temperature & state data |
| Communication | UMB (Universal Measurement Bus), RS-485, Modbus RTU, SDI-12 compatible |
| Compliance | EN 13103, WMO Guide to Meteorological Instruments and Methods of Observation (CIMO Guide), ASTM E1972 (Standard Practice for Pavement Condition Monitoring) |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | IRS31Pro-UMB |
| Measurement Principles | Conductivity-based salt concentration & freezing point detection, FMCW radar for water film thickness, NTC thermistor for surface temperature |
| Output Interfaces | UMB (Universal Measurement Bus), SDI-12, RS-485 |
| Power Supply | 6–30 VDC, solar-compatible |
| Operating Temperature | −40 °C to +70 °C |
| IP Rating | IP68 |
| Mounting | Flush-mountable in asphalt/concrete |
| Compliance | EN 12830, ASTM E1952, ICAO Annex 3, WMO Guide to Instruments and Methods of Observation |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | MARWIS-UMB |
| Measurement Principle | Spectral Reflectance Analysis (Near-Infrared), Infrared Pyrometry, NTC Thermistor, Capacitive Humidity Sensing |
| Sampling Frequency | 100 Hz |
| Mounting | Magnetic Base |
| Communication Interfaces | Bluetooth 4.2, RS-485 (Modbus RTU), CAN-BUS (SAE J1939) |
| Environmental Operating Range | −40 °C to +70 °C |
| IP Rating | IP67 |
| Compliance | CE, E-mark (E1), RoHS, ISO 9001-certified manufacturing |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | NIRS31-UMB |
| Measurement Principle | Near-Infrared Spectroscopy (NIRS) + Infrared Pyrometry |
| Output Parameters | Surface Temperature, Water Film Height, Ice/Snow Thickness, Ice Fraction, Freezing Point Depression, Salt Concentration, Friction Coefficient Estimate, Surface Condition Classification |
| Communication Protocol | UMB (Universal Measurement Bus), SDI-12, Modbus RTU, ASCII |
| Mounting | Non-intrusive overhead installation (typical height: 3–8 m) |
| Compliance | EN 13103, WMO Guide to Meteorological Instruments and Methods of Observation, ASTM E1967 (for pavement friction estimation), ISO/IEC 17025 traceable calibration support |
| Brand | Lufft |
|---|---|
| Origin | Germany |
| Model | StaRWIS-UMB |
| Measurement Principle | Spectral Reflectance Analysis + Infrared Pyrometry |
| Operating Temperature Range | –40 °C to +70 °C |
| Water Film Thickness Range | 0–6 mm (dual-mode output for smooth & rough surfaces) |
| Ice Coverage Detection | Qualitative & Quantitative (0–100% ice fraction estimation) |
| Surface Temperature Accuracy | ±0.5 °C |
| Friction Coefficient Estimation | Relative index (non-mechanical, algorithm-derived) |
| Optical Source | Long-life LED (no moving parts, >50,000 h MTBF) |
| Communication Interfaces | Bluetooth 5.0 (for configuration & diagnostics), RS-485 (Modbus RTU), CAN-BUS (SAE J1939 compliant) |
| Mounting | Pole- or gantry-mounted, no road cutting required |
| IP Rating | IP66 |
| Compliance | EN 12830, EN 13193, WMO Guide to Meteorological Instruments and Methods of Observation (CIMO Guide), ISO/IEC 17025 applicable for calibration traceability |
| Brand | LUMEX |
|---|---|
| Origin | USA |
| Model | RP100SC |
| Sample Pressure Range | Up to 6000 PSIG → Adjustable Output: 0–100 PSIG |
| Response Time | ≤1 s |
| Mercury Detection Compatibility | ppm-level Hg analysis |
| Thermal Control | Dual-stage heat exchangers + Joule–Thomson compensation via electrically heated inlet |
| Safety Certification | Suitable for Class I, Division 2 hazardous areas |
| Surface Treatment | SilcoNert®2000 inert passivation |
| Flow Path Configuration | Helical long-path regulator |
| Filtration | Integrated particulate filter at inlet |
| Interface Options | Tedlar® bag coupling + direct online integration with mercury analyzers (e.g., RP-915NG) |
| Compliance | SY/T 7321–2016 (Determination of Mercury in Wellhead Natural Gas by Differential Method) |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | M-Series Rugged Tree Micro-Drill Resistograph |
| Pricing | Available Upon Request |
| Maximum Penetration Depth | 300 mm |
| Feed Rate | 10–60 cm/min (Standard), 20–60 cm/min (Lightweight) |
| Resolution | 0.1 mm |
| Data Output | Thermal Wax Paper Strip Chart |
| Power Supply | 7.2 V, 1.7/2.0 Ah NiCd Rechargeable Battery |
| Charger Input | 110–220 V AC |
| Operating Environment | Wet, muddy, or uneven terrain (e.g., marshes, steep slopes) |
| Origin | Poland |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | MD-20 / MD-25 |
| Price | Upon Request |
| Rope Diameter Range | MD-20: 8–22 mm |
| MD-25 | 10–25 mm |
| Operating Speed | 0.1–2.5 m/s |
| Sensitivity Adjustment | 10-level potentiometer |
| Indicators | LB (red, low battery), OK (green, no defect), D (yellow, defect detected, flashing), DM (red, defective rope, steady) |
| Audible Alarm | Yes |
| Power Supply | Rechargeable 9 V battery |
| Operating Temperature | Standard models: −10 °C to +40 °C |
| MD-20L variant | −25 °C to +40 °C |
| Dimensions (L×W×H) | 205 × 46 × 280 mm (with roller guide) |
| Weight | MD-20: 4.5 kg |
| MD-25 | 4.9 kg |