Other Measurement Metrology Instruments
Filter
Showing 121–150 of 228 results
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | HP-33M |
| Frequency Range | 700 MHz – 3 GHz |
| Electric Field Range | 0.3 – 300 V/m |
| Overload Protection | > 600 V/m |
| Dynamic Range | > 60 dB |
| Resolution | 0.01 V/m |
| Sensitivity | 0.3 V/m |
| Absolute Accuracy @ 930 MHz (20 V/m) | ±1 dB |
| Frequency Response (900 MHz – 3 GHz) | ±1.5 dB |
| Isotropy @ 930 MHz | ±1 dB |
| H-Field Rejection | > 20 dB |
| Temperature Coefficient | 0.05 dB/°C |
| Calibration | Built-in EEPROM |
| Dimensions | 317 mm × Ø58 mm |
| Weight | 100 g |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDH-01 |
| Pricing | Available Upon Request |
| Frequency Range | 20 kHz – 10 MHz |
| Equivalent Protection Circuit | Integrated Transient Current Limiter per IEC 62493 |
| Output Impedance | 50 Ω |
| RF Input Interface (Sphere) | BNC Female |
| RF Output Interface | BNC Female |
| Sphere Diameter | 210 mm |
| Neck Simulator Wire Length | 300 mm |
| Tripod Mount Thread | 1/4″–20 UNC |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −20 °C to +70 °C |
| Weight (Excl. Tripod) | 1.7 kg |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDH-01 Test Head |
| Quotation | Upon Request |
| Frequency Range | 20 kHz – 10 MHz |
| Equivalent Protection Circuit | Integrated Transient Current Protection |
| Compliance | Fully IEC 62493 Conformant |
| Output Impedance | 50 Ω |
| RF Input Interface (Sphere) | BNC Female |
| RF Output Interface | BNC Female |
| Sphere Diameter | 210 mm |
| Neck Simulator Length | 300 mm |
| Tripod Mount | 1/4″–20 UNC Thread |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −20 °C to +70 °C |
| Weight (excl. tripod) | 1.7 kg |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DO |
| Pricing | Upon Request |
| Lenslet Pitch | 150 µm |
| Lenslet Focal Length | 5.2 mm (customizable) |
| Dynamic Range | ≥30 µm |
| Sensitivity | λ/100 @ 633 nm |
| Measurement Accuracy | <10 nm RMS |
| Repeatability | λ/200 @ 633 nm |
| Sensor Active Area | 11.3 mm × 7.12 mm |
| Pixel Resolution | 1920 × 1200 |
| Spectral Response | 400–1000 nm |
| Frame Rate | up to 700 fps |
| Physical Dimensions | 42.6 mm × 29 mm × 29 mm |
| Supported Camera Interfaces | 20+ industrial camera types |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | EUV/UV |
| Pricing | Upon Request |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NIR/EUV |
| Pricing | Upon Request |
| Spectral Range | 1100 nm – 1 nm |
| Dynamic Range | up to 100λ |
| Sensitivity | <100 pm |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Camera Compatibility | >20 industrial and scientific camera models supported |
| Micro-lens Array Options | Multiple pitch/focal-length configurations available |
| Software | ISO-compliant beam analysis suite with Zernike decomposition, M² real-time calculation, and Fresnel–Kirchhoff propagation engine |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Model | UV |
| Spectral Range | ~1–1100 nm (EUV, UV, VIS, NIR) |
| Sensor Types | >20 interchangeable CCD/CMOS cameras (small/large area, high resolution, high dynamic range) |
| Interface | USB 3.0 or GigE |
| Bit Depth | 12-bit / 14-bit |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Software | Full remote control & automation support (adaptive optics, motorized attenuators, shutters, power meters) |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Type | Imported Instrument |
| Model | UV/VIS |
| Price | Upon Request |
| Spectral Range | 190–1100 nm |
| Measurement Principle | Shack-Hartmann Wavefront Sensing |
| Dynamic Range | up to 100λ |
| Sensitivity | <100 pm |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Camera Compatibility | >20 industrial camera models supported |
| Zernike Polynomial Analysis | Yes |
| Real-time M² Calculation | Yes |
| Single-shot Acquisition | Yes |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Model | UV/VUV |
| Wavelength Range | 100–1100 nm (quantum conversion coating active <320 nm |
| Field of View | 20 mm × 14 mm (custom FOVs available) |
| Sensor | 4 MP CMOS, 12-bit, USB 3.0 interface |
| Frame Rate | up to 15 fps |
| Exposure Time | 20 µs – 1 s |
| Attenuation | prism-based attenuator (1000:1), optional ND filters |
| Compliance | ISO 11146, ISO 13694, ISO 11670, ISO 15367 |
| Software | ISO-compliant beam analysis suite supporting ≥20 camera types |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | PSL8 MODBUS |
| Price | Upon Request |
| Operating Voltage | 6–16 VDC |
| Current Consumption | 13–20 mA (active), 400 µA (standby) |
| Operating Temperature Range | −40 to +80 °C |
| Square Wave Input Frequency Range | 1 Hz – 35 kHz |
| Low-Frequency AC Input Sensitivity | 20 mV RMS (min. for 1–20 Hz), 200 mV RMS (min. for 0.5–200 Hz), 2000 mV RMS (min. for 0.3–10 kHz), 5000 mV RMS (min. for 0.3–20 kHz) |
| Output Signal | Modbus RTU over RS-485 (2-wire or 4-wire) |
| Brand | ProOpto |
|---|---|
| Origin | Germany |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | Astronomical Telescope Dedicated |
| Pricing | Upon Request |
| Brand | PV-Tools |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TLM-SCAN |
| Pricing | Available Upon Request |
| Brand | pv-tools |
|---|---|
| Origin | Germany |
| Model | TLM-SCAN+ |
| Dimensions | 230 mm (W) |
| Probe Type | Motorized 14-Stripe Adjustable TLM Probe with Vacuum Chuck |
| Measurement Principle | Transfer Length Method (TLM) + Four-Point Probe (4PP) |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments, supports GLP audit trails and measurement traceability to SI units |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CR-10 |
| Calibration Traceability | NIST |
| Accreditation | ISO/IEC 17025 (A2LA & UKAS) |
| Recommended Recalibration Interval | Annually |
| Compatible With | QUV Accelerated Weathering Testers (UV-A and UV-B lamp configurations) |
| Excludes | QUV Basic, QUV/cw (requires CR-10/cw), Q-SUN (requires CR-20 series) |
| Brand | QNET |
|---|---|
| Origin | Germany |
| Model | P3123 |
| Detection Frequency | 5–25 MHz |
| Measurement Repeatability | ±0.2 mm |
| Channels | 4 Ultrasonic Channels |
| Enclosure Rating | IP65 |
| Application | Non-Destructive SHD Measurement for Induction-Hardened Components |
| Brand | Radiant Vision Systems |
|---|---|
| Model | TrueTest™ |
| Origin | USA |
| Type | Imaging Photometer-Based AOI System |
| Compliance | CIE 1931 Standard Observer, ISO 9241-307, ASTM E308, USP <1058> (for instrument qualification), FDA 21 CFR Part 11 (software audit trail enabled) |
| Detection Capabilities | Pixel defects, line defects, Mura (JND-mapped), luminance uniformity, chromaticity uniformity, contrast ratio, gamma, and spatial nonuniformity analysis |
| Software Platform | TrueTest™ Suite v6.0+ with JND-based defect quantification engine, GLP/GMP-compliant reporting, and automated pass/fail classification |
| Brand | Restek |
|---|---|
| Model | GC-Specific Thermal Conductivity Gas Leak Detector |
| Detection Principle | Thermal Conductivity Differential Sensing |
| Detectable Gases | He, H₂, N₂, Ar, CO₂ |
| Minimum Detectable Leak Rate | 1.0 × 10⁻⁶ atm·cc/sec (H₂), 1.0 × 10⁻⁵ atm·cc/sec (He), 1.0 × 10⁻⁴ atm·cc/sec (Ar/CO₂), 1.4 × 10⁻³ atm·cc/sec (N₂) |
| Response Time | ≤2 seconds |
| Power Supply | Rechargeable NiMH battery (6 h typical operation) with low-battery and charging indicators |
| Operating Temperature | 0–48 °C (32–120 °F) |
| Relative Humidity | 0–97 % RH |
| Enclosure Rating | CE, Ex (ATEX/IECEx compliant for non-incendive use), Japan PSE |
| Compliance | RoHS, WEEE |
| Auto-Zero Function | One-button activation |
| Probe Design | Ruggedized, flexible-tip, cleanable, position-switch enabled |
| Housing | Ergonomic handheld chassis with side-grip reinforcement |
| Auto-Shutdown | Enabled after 5 minutes of inactivity |
| Accessories Included | Hard-shell carrying case, universal AC adapter kit |
| Warranty | 1 year limited |
| Brand | Restek |
|---|---|
| Origin | USA |
| Model | LD-229 |
| Detection Principle | Thermal Conductivity (TCD-based) |
| Detectable Gases | He, H₂, Ar, Ne |
| Minimum Detectable Leak Rate | 0.01 mL/min (for He and H₂) |
| Power Source | Rechargeable Ni-Cd battery (4 h charge time, 5 h typical operation, up to 9 h with fresh fully charged battery) |
| Operating Temperature | 10–35 °C |
| Dimensions | 65 mm (W) × 37 mm (D) × 143 mm (H) |
| Probe Length | 85 cm |
| Net Weight | 330 g |
| Display | LCD with real-time status indication |
| Alarm | Dual-mode — visual (LED) and audible (variable-tone buzzer) |
| Compliance | Designed for laboratory and industrial leak-checking in accordance with ASTM E1715 and ISO 10012-based verification practices |
| Accessories | EU-type AC adapter (220 V), replaceable particulate filter (P/N 2702-19395) |
| Brand | Restek |
|---|---|
| Model | ProFLOW 6000 |
| Origin | USA |
| Flow Range | 0.5–500 mL/min |
| Accuracy | ±2% of reading or ±0.05 mL/min (whichever is greater) |
| Calibration Traceability | NIST-traceable |
| Explosion Protection | Certified for flammable and explosive gases (Ex-rated) |
| Operating Temperature | 0–48 °C |
| Relative Humidity | 0–97% RH (non-condensing) |
| Power Supply | 2 × AA batteries |
| Data Interface | USB |
| Certifications | CE, RoHS, WEEE |
| Enclosure Options | Handheld and benchtop configurations |
| Auto-shutdown | Yes |
| Warranty | 1 year |
| Brand | Rinntech |
|---|---|
| Origin | Germany |
| Model | ARBOTOM® |
| Type | Portable Acoustic Impulse Tomography System for In Situ Tree Health Assessment |
| Sensor Configuration | 2–24+ Adjustable Multifunctional Piezoelectric Sensors |
| Data Output | Color-Coded 2D Cross-Sectional & Optional 3D Volumetric Reconstructions |
| Compliance | Designed for Field Deployment in Accordance with DIN EN 12512, ISO 12716, and ASTM D6248 (Non-Destructive Evaluation of Wood) |
| Software Platform | ArborScan™ v5.x with Audit Trail, GLP-Compliant Reporting, and FDA 21 CFR Part 11–Ready Configuration Options |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Deposition Watch |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | 100 mL/min Full-Scale |
| Pricing | Upon Request |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GL-102B |
| Price | USD 520 (FOB) |
| Flow Range | 1–1000 mL/min |
| Accuracy | ±1% of reading |
| Measurement Time Range | 0.1–600.0 s (internal resolution: 0.01 s) |
| Display | LCD with simultaneous readout of temperature, pressure, volume, and flow rate |
| Power | Rechargeable 4.8 V / 700 mAh battery (standby >300 h |
| Operating Principle | Gravimetric soap film displacement method |
| Calibration | On-site temperature, pressure, and volumetric correction for mass and volumetric flow output |
| Brand | -- |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SAP500 Series |
| Pricing | Upon Request |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TCOPRS-CCR-SW-25 |
| Pricing | Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AU-SMK |
| Pricing | Upon Request |
| Weighing Capacity | 120–320 g |
| Minimum Readability | 0.1 mg |
| Density Resolution | 0.0001 g/cm³ |
| Density Measurement Modes | Solid (fixed-density method), Liquid (requires optional sinker P/N 321-60640) |
| Origin | Japan |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Interior Materials Testing System |
| Pricing | Upon Request |
| Brand | Signal Recovery |
|---|---|
| Origin | USA |
| Model | 7280 |
| Frequency Range | 0.5 Hz to 2 MHz |
| ADC Sampling Rate | 7.5 MHz |
| Time Constant Range | 1 µs to 100 ks |
| Harmonic Detection | up to 32nd order (32F) |
| Reference Modes | Dual Reference, Dual Harmonic, Virtual Reference |
| Spectrum Display Mode | Enabled |
| Optional Frequency Extension | up to 2 MHz for dual-reference/dual-harmonic operation |
| Software Compatibility | Acquire software, LabVIEW drivers |
| Internal Oscillator | Quartz-stabilized |
| Brand | Signal Recovery |
|---|---|
| Origin | USA |
| Model | 7280 |
| Frequency Range | 0.5 Hz to 2 MHz |
| ADC Sampling Rate | 7.5 MHz |
| Time Constant Range | 1 µs to 100 ks |
| Reference Modes | Dual Reference, Dual Harmonic, Virtual Reference |
| Optional Frequency Extension | Up to 2 MHz for Dual Reference/Dual Harmonic Operation |
| Input Modes | Voltage and Current |
| Software Support | Acquire Data Acquisition Software, LabVIEW Drivers Available |
| Form Factor | Front-Panel Equipped (Standard) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2102 |
| Spectral Response | Matched to CIE Erythema Action Spectrum (ISO 17166:2019 / CIE S 007/E-1998) |
| Angular Response | ≤5% deviation from ideal cosine up to 60° |
| Measurement Range | 0–120 µW/cm² (0–1.2 W/m²), equivalent to 0–20 MED/hr |
| Resolution | 0.001 mW/cm² / 0.01 W/m² |
| Operating Temperature | −40 °C to +50 °C (−40 °F to +120 °F) |
| Temperature Coefficient | 1% / °C (numerically compensated via integrated thermistor and algorithm) |
| Diffuser | PTFE-based, Lambertian, effective field-of-view up to 50° |
| Cable Length | 15 m (50 ft) |
| Dimensions | Ø40.6 mm × H45.8 mm |
| Weight | 200 g |
| Calibration | NIST-traceable, erythemally weighted |
