Other Physical Property Testing Instruments
Filter
Showing 361–390 of 489 results
| Brand | 3i |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NMI CRYOSTAT: CRYOGENFREE ULTRA LOW-VIBRATION CRYOS |
| Maximum Magnetic Field | 14.0 T |
| Temperature Range | 1.3 K to 300 K |
| Sample Diameter | Up to 49 mm |
| VTI Configuration | Top-Loading Variable-Temperature Insert |
| DSV Homogeneity | ≤0.1% over 1 cm |
| Brand | NanOsc AB |
|---|---|
| Origin | Sweden |
| Model | PhaseFMR / CryoFMR Series |
| Frequency Range | 2–40 GHz |
| Temperature Range | Room Temperature to 4 K |
| Magnetic Field Range | ±0.7 T to ±16 T (platform-dependent) |
| Frequency Accuracy | ±0.05 GHz |
| SNR | >10 for 10 nm Ni₈₀Fe₂₀ at 40 GHz |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | H-12 |
| Weight | 8 g |
| Overall Length | 80 mm |
| Heating Rod Diameter | 7 mm |
| Heating Rod Length | 65 mm |
| Material | High-grade stainless steel and heat-resistant polymer |
| Mounting Type | Standard 3-axis micromanipulator compatible (e.g., MO-10, MN-151) |
| Operating Temperature Range | Ambient to 120 °C (with optional external controller) |
| Compliance | CE-marked for laboratory use |
| Brand | Narishige |
|---|---|
| Model | HD-21 |
| Origin | Japan |
| Type | Dual-Pipette Manipulation Handle |
| Dimensions | 127 mm (W) × 38 mm (D) × 52 mm (H) |
| Weight | 105 g |
| Accessories | Universal Wrench |
| Category | Physical Property Testing Instruments — Other Manipulation & Handling Accessories |
| Brand | FJW |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NewOpto 85720 / 85700 / 85726 / 85706 |
| Spectral Sensitivity | 400–1800 nm (85720/85700) / 400–2200 nm (85726/85706) |
| Displayed Regions | Visible, Near-IR, Mid-IR |
| Peak Sensitivity | 600 nm |
| Focal Range | 4 inches to infinity |
| Detector | 25 mm high-performance infrared vidicon |
| Standard Lens | C-mount, 25 mm, f/1.4, manual iris |
| Gain Control | Selectable auto-gain and 4 fixed gain levels |
| Signal-to-Noise Ratio | 68 dB |
| Horizontal Resolution | Up to 700 TV lines |
| Video Output | RS-170 via BNC connector |
| Dimensions | 110.3 × 111.2 × 216.4 mm³ |
| Optional Accessory | Electronic viewfinder module |
| Brand | FJW |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Newopto 85050A / 85050A-5 / 85051A / 85051A-5 |
| Spectral Sensitivity | 350–1350 nm / up to 1550 nm |
| Displayed Regions | Near-UV, Visible, Near-IR |
| Peak Spectral Sensitivity | 800 nm |
| Focal Range | 4 inches to infinity |
| Resolution | 70 line pairs per millimeter |
| Field of View | 40° |
| Magnification | ~1:1 |
| Lens | Custom Infragon 25 mm, f/1.0 |
| Optional IR Illuminator | Incandescent source with 780 nm long-pass filter |
| Brand | NEXOPART |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ALPINE Sieve Disc |
| Pricing | Available Upon Request |
| Brand | NEXOPART |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Grain and Tobacco Test Sieves |
| Pricing | Available Upon Request |
| Brand | NEXOPART |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Wooden-Frame Sieve Tray |
| Pricing | Available Upon Request |
| Brand | 3i |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 2 AXIS PIEZO ROTATOR |
| Pricing | Upon Request |
| Rotation Range (per axis) | ±90° |
| Angular Resolution | 1 µdeg (0.000001°) |
| Operating Temperature Range | 10 mK – 300 K |
| Maximum Magnetic Field Compatibility | 15 T |
| Compatible Carrier | Standard 20-pin Leadless Chip Carrier (LCC) |
| Drive Mechanism | Piezoelectric Motor |
| Controller Interface | USB 2.0 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Numbers | 487, 497, 597 |
| Pricing | Available Upon Request |
| Torque Range | 2.83 N·m to 452,000 N·m (25 to 4,000,000 lb·in) |
| Accuracy | ±0.05% FS (Torque Analog Output) |
| Output | Engineering-Unit Digital via RS-232/RS-485 Serial Port |
| Signal Filtering | 11 Selectable Constant-Delay Low-Pass Filters |
| Overload Capacity | 200%, 400%, and 1,000% of Full Scale |
| Noise & Ripple | ≤0.02% FS |
| EMI Hardening | Optimized for Variable Frequency Drive (VFD) Environments |
| Calibration | Remote, Bidirectional, NIST-Traceable |
| Software | PC-Based Interface with Support for 33 Engineering Units (No Recalibration Required) |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | CHT |
| Price Range | USD 10,600 – 13,250 |
| Heating Plate Temperature Range | Ambient to 500 °C |
| Contact Surface Diameter | 25.0 ± 0.05 mm × Depth: 5.0 ± 0.02 mm |
| Thermocouple Measurement Range | ≥ 500 °C |
| Contact Force | 49 N (± 1 N) |
| Contact Speed | 5 mm/s (± 0.2 mm/s) |
| Actuation | Servo-motor-controlled heat flux sensor with programmable vertical motion |
| Horizontal Sample Platform Translation | Motorized lateral displacement for safe, repeatable specimen loading |
| Data Acquisition | PLC-based real-time logging of onset temperature, threshold time, termination temperature, and continuous surface temperature |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | CWT-A1-1 |
| Pricing | Upon Request |
| Measurement Principle | Transient heat flux quantification under controlled contact pressure and temperature differential |
| Test Parameter | Q-max (J/(cm²·s)) |
| Heat Plate Material | Copper |
| Heat Plate Area | 9 cm² |
| Contact Pressure | 0.1 ± 0.01 N/cm² |
| Heat Plate Temperature Range | 20–40 °C |
| Temperature Sensor Response Time | ≤ 0.2 s |
| Temperature Resolution | 0.1 °C |
| Sample Platform Temperature Control | Yes |
| Required ΔT Between Plate and Platform | 15 °C |
| Calibration Compliance | GB/T 35263-2017, FTTS-FA-019 |
| System Components | Thermally regulated copper heat plate, insulated sample stage, high-speed data acquisition card, PC-based analysis software |
| Brand | NYX |
|---|---|
| Model | HTI |
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | AQ 6103, ISO 9151, EN 367, ISO 11612, GB 38453 |
| Heat Flux | 80 kW/m² |
| Temperature Rise Targets | (24 ± 0.2) °C and (12 ± 0.1) °C |
| Measurement Principle | Calorimetric determination of heat transfer index (HTI) via copper calorimeter |
| Cooling Method | Forced-air cooling of copper calorimeter |
| Automation | Pneumatic actuation of heat shield and specimen holder |
| Data Output | HTI-24 and HTI-12 values (seconds), averaged across three replicates |
| Software Features | Real-time thermal recording, automatic heat flux correction, GLP-compliant audit trail |
| Brand | NYX |
|---|---|
| Model | MES |
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Price Range | USD 9,000 – 11,500 |
| Compliance Standards | AQ 6103, ISO 9150:1988, CSN EN 348:1992, GB 8965.2–2009, GB/T 17599–1998, ISO 11611, ISO 11612, EN 407 |
| Burner Type | Oxy-acetylene torch with 1.2 ± 0.1 mm nozzle |
| Metal Feed Mechanism | Stepper motor-driven wire feed system with adjustable linear speed |
| Drip Guidance Angle | 45° |
| Anti-stick Guide Channel | High-temperature ceramic-coated or PTFE-lined (per ISO 9150 Fig.3 / EN 348 Fig.3) |
| Backside Temperature Sensor | Precision thermocouple array (Type K, ±0.5 °C accuracy) |
| Pre-tension Device | Calibrated copper weight assembly (175.0 ± 0.5 g) |
| Data Acquisition | Touchscreen HMI with real-time thermal curve plotting, drip count & frequency logging |
| Safety Enclosure | Interlocked stainless-steel safety hood with optical shielding and ventilation interface |
| Brand | NYX |
|---|---|
| Model | MET |
| Origin | Tianjin, China |
| Manufacturer | Yes |
| Type | Domestic |
| Price Range | USD 28,500 – 35,600 |
| Standards Compliance | EN 373, ISO 9185, EN 407, ISO 11612, GB 2811:2019, BS EN 397:2012, EN 14052:2012+A1:2012, GB/T 38306:2019 |
| PVC Film Spec | 300 ± 30 g/m² |
| Crucible Capacity | 190 mL |
| Crucible Dimensions | Ø80 mm (top), Ø56 mm (bottom), H = 97 mm |
| Melting Temperature Range | 700–1800 °C |
| IR Pyrometer Range | Up to 2400 °C, Accuracy ±1% |
| Tilt Mechanism | Stepper motor–controlled angle and speed |
| Cooling | Integrated recirculating water cooling system |
| Frame | Stainless steel sample holder with integrated PVC film mounting |
| Brand | NYX |
|---|---|
| Model | RHP |
| Origin | Tianjin, China |
| Manufacturer | NYX Instrument Co., Ltd. |
| Radiation Source | 6 SiC heating rods (total length 356 ± 2 mm |
| Temperature Control | PID-regulated, accuracy ±1 °C |
| Max Radiation Source Temp | 1200 °C ± 5% |
| Radiant Heat Flux Range | 10–80 kW/m² |
| Heat Flux Sensor | Commercial quartz-window sensor with water cooling, range up to 100 kW/m² |
| Calorimeter | Oxygen-free high-conductivity copper disk calorimeter for backside temperature rise measurement |
| Sample Holders | Dual-configurable fixtures per ISO 6942 Test A and Test B |
| Sample Translation Stage | Motorized XY positioning platform |
| Data Acquisition | 20 Hz sampling rate |
| Software Platform | Windows XP-based control & analysis suite with bilingual (EN/CN) UI, automated test initiation, real-time thermal response logging, and calculation of time-to-12°C/24°C rise, incident heat flux (Q), and heat transfer coefficient (HF) |
| Brand | NYX |
|---|---|
| Model | RRT-036 |
| Origin | Tianjin, China |
| Manufacturer | Yes |
| Heating Power | 4000 W (main) + 2000 W (auxiliary) |
| Compliance | EN 136, EN 137, GB/T 16556–2007, XF/GA 124 |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | 500o / 500o HR / 500o XY |
| Measurement Principle | Digital Image Analysis (Static Imaging) |
| Dry Dispersion | Integrated Vacuum-Based System |
| Wet Dispersion | Computer-Controlled Syringe Pump with Three-Way Valve |
| Optical Configuration | Collimated 440 nm Blue LED Backlight (Transmitted) + Diffuse White LED (Reflected) |
| Camera | Progressive Scan CMOS (6.6 MP for 500o |
| Lens | Zoom Telecentric Objective |
| Pixel Resolution Range | 0.19–4.7 µm/pixel (model-dependent) |
| Field of View | Up to 10.27 × 14.00 mm (low-mag) down to 730 × 522 µm (high-mag) |
| Dry Mode Range | 0.2–3000 µm |
| Wet Mode Range | 0.8–300 µm |
| Reflectance Mode Range | 1–3000 µm |
| Analysis Time | 1–3 min per sample |
| Software | Callisto 2D (500o, 500o HR) or Callisto 3D (500o XY) |
| Compliance | ISO 13322-1 & ISO 13322-2, FDA 21 CFR Part 11 (audit trail, electronic signature, user access control), GLP/GMP-ready 3Q Validation (IQ/OQ/PQ) |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | FC200 Series |
| Particle Size Range | 0.2 µm – 3 mm |
| Imaging Resolution | Down to 0.17 µm/pixel |
| Number of Morphological Parameters | 50–80 |
| Sample Volume Range | Microliter to >1 L |
| Maximum Undiluted Sample Concentration | 5% (v/v) |
| Light Source | 440–450 nm Collimated Blue LED |
| Camera Options | 5–12 MP CMOS/CCD |
| Software Platform | Callisto 2D/3D |
| Regulatory Compliance | 21 CFR Part 11, IQ/OQ/PQ (3Q) Validation Support |
| Pump Types | Peristaltic, Diaphragm, Syringe, or Integrated Injection Pumps |
| Temperature Control (FC200TC) | Ambient to 140 °C |
| Specialized Configurations | FC200M+(HR), FC200S+(HR), FC200TC, FC200P, FC200BAG, IPAC 1, IPAC 2 CMP |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | SCAN Series |
| Particle Size Range | 10 µm – 50 mm (extendable to 2 µm – 20 cm) |
| Optical Resolution | Up to 600 Mpx (Scan 700) |
| Illumination | Broadband white light (350–640 nm), transmission + reflection modes |
| Imaging Sensor | High-speed CCD linear array |
| Software | Callisto 2D/3D |
| Dispersion | Dry-mode linear disperser with anti-adhesion metal coating |
| Sample Stage | 242 × 320 mm (Scan 700) |
| Compliance | ASTM D7927, ISO 9276-6, USP <1788>, GLP-ready audit trail in Callisto |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | Zephyr LDA / Zephyr ESR / Morpho 3 |
| Dry Measurement Range (Zephyr LDA) | 7 µm – 5000 µm |
| Wet Measurement Range (Zephyr LDA) | 1 µm – 3000 µm |
| Dry Measurement Range (Zephyr ESR) | 30 µm – 30 mm (extendable lower limit) |
| Dry Measurement Range (Morpho 3) | 500 µm – 10,000 µm |
| Analysis Time | 1–3 min per sample |
| Camera System | 5 MP CCD (Zephyr LDA/ESR), dual 1.3 MP (Morpho 3: 24-bit color front + 8-bit monochrome side) |
| Light Source | 440 nm blue LED (Zephyr LDA/ESR), dual diffuse white LED + monochromatic LED (Morpho 3) |
| Lens Type | Telecentric (Zephyr LDA), dual telecentric (Zephyr ESR), fixed-focus (Morpho 3) |
| Dispersion | Vibratory feed + transverse vacuum (Zephyr LDA), gravity-assisted vibration (Zephyr ESR), controlled rotary vibration + linear belt transport (Morpho 3) |
| Auto-Cleaning | Compressed air + vacuum (all models) |
| Software | Callisto 3D |
| Compliance | ISO 13322-2, ASTM E2927, FDA 21 CFR Part 11 (with optional 3Q validation: IQ/OQ/PQ) |
| Dimensions & Weight | Zephyr LDA: 85 × 47 × 64 cm, 52 kg |
| Zephyr ESR | 80 × 44 × 60 cm, 43 kg |
| Morpho 3 | 99 × 52 × 60 cm, 75 kg |
| Brand | Oelabs |
|---|---|
| Origin | Taiwan |
| Model | Hall8686 |
| Magnetic Field Strength | 0.53 T |
| Temperature Range | 77 K–423 K (optional up to 623 K) |
| Temperature Accuracy | ±0.5 K |
| Current Output | 1 nA–100 mA |
| Voltage Resolution | down to nV level (up to 300 V) |
| Carrier Concentration Range | 10⁷–10²¹ cm⁻³ |
| Mobility Range | 1–10⁷ cm²/(V·s) |
| Resistivity Range | 10⁻⁵–10⁷ Ω·cm |
| Sample Size | 5–15 mm diameter, thickness ≤1 mm |
| Sample Holder | proprietary spring-loaded four-point probe fixture |
| Compatible Materials | Si, ZnO, SiGe, SiC, GaAs, InGaAs, InP, GaN (n-type and p-type) |
| Brand | Ophir |
|---|---|
| Origin | Israel |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | Vega, Nova II, LaserStar, Nova, Orion, BeamTrack |
| Interface Options | USB, RS232, GPIB, Analog Output (1V/2V/5V/10V), Trigger I/O |
| Sampling Rates | Up to 250 kHz (Vega), 2 kHz (Nova II/LaserStar), 1.5 kHz (LaserStar), 10–30 Hz (Nova/Orion) |
| Data Storage | On-device real-time logging, PC-based active storage via USB |
| Software Support | Ophir StarLab v3.x, LabVIEW VIs, ActiveX Controls, FDA 21 CFR Part 11-compliant audit trail (optional), GLP/GMP-ready reporting |
| Detector Compatibility | Thermopile, Photodiode, Pyroelectric, RP (Radiation Pressure), BeamTrack (position & beam diameter) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | ANS800 Series |
| Max Operating Temperature | 800 °C or 1000 °C |
| Compliance | ASTM C336 |
| Temperature Control | PID-controlled, automated |
| Measurement Principle | LVDT-based fiber elongation monitoring under controlled cooling |
| Data Processing | Automated calculation of annealing point (AP) and strain point (SP) per ASTM C336 |
| Accuracy | ±1 °C (for glass fiber samples) |
| Software | Orton proprietary control & analysis suite with real-time plotting, statistical reporting, and audit-ready data logging |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OSA-type |
| Pricing | Available Upon Request |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | PCW-3000 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PEANUTS |
| Price | Upon Request |
| Brand | Piezotest |
|---|---|
| Origin | Singapore |
| Model | PM200 |
| Price Range | USD 30,000–50,000 |
| d₃₃ Measurement Range | 0–10,000 pC/N |
| Resolution | 0.01 pC/N (lowest range) |
| Test Frequencies | 30–300 Hz (1 Hz step, calibrated at 110 Hz) |
| Static Force Range | 0–10 N |
| Dynamic Force Range | 0.05–0.5 N |
| Capacitance Range | 10 pF–0.1 µF |
| Loss Tangent (tanδ) Range | 0.0000–0.2000 |
| Max Sample Diameter | 136 mm |
| Max Sample Thickness (Polarization Direction) | 50 mm |
| Max Sample Mass | 1 kg |
| Compliance | ASTM D790, IEC 62047-18, ISO 20482 (referenced for piezoelectric characterization) |
| Brand | Piezotest |
|---|---|
| Origin | Singapore |
| Model | PM300 |
| d₃₃ Range | 0–10,000 pC/N |
| Resolution | 0.01 pC/N (lowest range) |
| Adjustable Static Force | 0–10 N |
| Dynamic Force | 0.05–0.5 N |
| Test Frequency | 30–300 Hz (1 Hz step, calibrated at 110 Hz) |
| Capacitance Measurement | 10 pF–0.1 µF |
| Loss Tangent (tan δ) | 0.0000–0.2000 |
| Max Sample Dimensions | Ø136 mm × 50 mm (polarization direction) |
| Max Sample Weight | 1 kg |
| Compliance | ASTM D790, IEC 62047-18, ISO 6722 (referenced for piezoelectric characterization) |