Packaging Industry Specialized Instruments
Filter
Showing 331–360 of 1185 results
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | N560 2.0A |
| Quotation | Upon Request |
| Test Principle | Differential Pressure Method (ASTM D1434, ISO 2556, GB/T 1038.1, ISO 15105-1, YBB 00082003, ChP 2025 <4007>) |
| Measurement Range | 0.01–25,000 cm³/(m²·24 h·0.1 MPa) |
| Resolution | 0.0001 cm³/(m²·24 h·0.1 MPa) |
| Temperature Control Range | 15–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Vacuum Accuracy | ±0.2% of reading |
| Ultimate Vacuum | <10 Pa |
| Vacuum Resolution | 0.01 Pa |
| Test Pressure | 0.1 MPa |
| Permeation Area | 50.24 cm² |
| Specimen Diameter | Φ110 mm |
| Max. Specimen Thickness | ≤2 mm |
| Chamber Count | 6 |
| Pneumatic Pressure | ≥0.3 MPa |
| Power | 1500 W |
| Supply | AC 220 V, 50 Hz |
| Dimensions | 1140 × 600 × 440 mm |
| Test Gases | O₂, CO₂, N₂, air, He |
| Compliance | ASTM, ISO, GB/T, JIS, YBB, ChP 2025 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | N600 |
| Price Range | USD 4,200 – 7,000 |
| Test Methods | Gurley, Schopper-Riegler, Bentzen |
| Standards Compliance | SJ/T 10171–2016, GB/T 458–2008, GB/T 36363–2018 |
| Permeability Range | 0.01–2.5 µm/(Pa·s) |
| Air Flow Rate Range | 0.01–120 mL/min (customizable) |
| Resolution | 0.001 µm/(Pa·s) |
| Differential Pressure Range | 0–3 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area Options | 6.42 cm² or 10.0 ± 0.2 cm² |
| Sample Dimensions | 50 mm × 50 mm (Gurley/Bentzen), 60 mm × 100 mm (Schopper-Riegler) |
| Conditioning | 24 h at <40 °C and 10–35% RH |
| Chamber Temperature & Humidity Monitoring | Integrated sensor |
| Seal Integrity | ≤1.0 mL/h leakage |
| Power | 100 W |
| Input | 220 V, 50 Hz |
| Dimensions (L×W×H) | 500 mm × 400 mm × 300 mm |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | N600-1 |
| Test Methods | Gurley, Schopper-Riegler, Bendtsen |
| Permeability Range | 0.01–2.5 µm/(Pa·s) |
| Air Flow Rate | 0.01–120 mL/min (custom ranges available) |
| Resolution | 0.001 µm/(Pa·s) |
| Differential Pressure Range | 0–3 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Standard Test Pressures | 1.23 kPa ±0.01 kPa (Gurley), 1.00 kPa ±0.01 kPa or 2.50 kPa ±0.01 kPa (Schopper-Riegler), 1.47 kPa ±0.02 kPa (Bendtsen) |
| Test Duration | 10–6000.0 s |
| Sample Area Options | 6.42 cm² (50 mm × 50 mm) or 10.0 ±0.2 cm² (60 mm × 100 mm or 50 mm × 50 mm) |
| Chamber Temperature & RH Monitoring | Integrated sensor |
| Seal Integrity | ≤1.0 mL/h leakage |
| Dimensions (L×W×H) | 500 × 400 × 300 mm |
| Power | 100 W |
| Voltage/Frequency | 220 V, 50 Hz |
| Sample Conditioning | Pre-conditioning at <40 °C and 10–35 %RH for 24 h |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | N600-2 |
| Testing Methods | Gurley, Schopper, Bendtsen |
| Pressure Differential Range | 0–3 kPa (±0.01 kPa accuracy) |
| Adjustable Test Areas | 6.42 cm² or 10.0 ± 0.2 cm² |
| Sample Size | 50 mm × 50 mm or 60 mm × 100 mm |
| Permeability Range | 0.01–2.5 µm/(Pa·s) |
| Air Flow Rate | 0.01–120 mL/min |
| Resolution | 0.001 µm/(Pa·s) |
| Test Duration | 10–6000.0 s |
| Temperature & RH Monitoring | Integrated sensor |
| Seal Integrity | ≤1.0 mL/h leakage |
| Power | 100 W, 220 V, 50 Hz |
| Dimensions (L×W×H) | 500 mm × 400 mm × 300 mm |
| Compliance | SJ/T 10171–2016, GB/T 458–2008, GB/T 36363–2018 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | N600-4 |
| Price Range | USD 14,000 – 72,000 |
| Testing Methods | Gurley, Schopper, Bentzen |
| Standard Compliance | SJ/T 10171–2016, GB/T 458–2008, GB/T 36363–2018 |
| Measurement Range (Gurley) | 0.01–2.5 µm/(Pa·s) |
| Air Flow Rate Range | 0.01–120 mL/min |
| Resolution | 0.001 µm/(Pa·s) |
| Differential Pressure Range | 0–3 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area Options | 6.42 cm² or 10.0 ± 0.2 cm² |
| Sample Size | 50 mm × 50 mm or 60 mm × 100 mm |
| Conditioning | 24 h at <40 °C, 10–35 %RH |
| Temperature & Humidity Monitoring | Integrated sensor |
| Chamber Leak Rate | ≤1.0 mL/h |
| Power | 100 W |
| Voltage/Frequency | 220 V, 50 Hz |
| Dimensions (L×W×H) | 500 mm × 400 mm × 300 mm |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | N600-5 |
| Price Range | USD 7,000 – 14,000 |
| Test Methods | Gurley, Schopper, and Bentzen |
| Measurement Range | 0.01–2.5 µm/(Pa·s) |
| Air Flow Rate | 0.01–120 mL/min (custom ranges available) |
| Resolution | 0.001 µm/(Pa·s) |
| Differential Pressure Range | 0–3 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Standard Test Pressures | 1.23 kPa ±0.01 kPa (Gurley), 1.00 kPa ±0.01 kPa or 2.50 kPa ±0.01 kPa (Schopper), 1.47 kPa ±0.02 kPa (Bentzen) |
| Test Duration | 10–6000.0 s |
| Sample Dimensions | 50 mm × 50 mm (effective area: 6.42 cm²) or 60 mm × 100 mm / 50 mm × 50 mm (effective area: 10.0 ±0.2 cm²) |
| Conditioning Requirements | ≤40 °C, 10–35 %RH, 24 h equilibration |
| Chamber Environmental Monitoring | Integrated temperature & humidity sensors |
| Seal Integrity | ≤1.0 mL/h leakage rate |
| Enclosure Dimensions | 500 mm × 400 mm × 300 mm (L×W×H) |
| Power Consumption | 100 W |
| Supply | 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | N600C |
| Pricing | Upon Request |
| Test Principle | Differential Pressure (Manometric) Method |
| Compliant Standard | GB/T 20042.7–2014 |
| Measurement Range | 0–200,000 mL·mm/(cm²·h·mmHg) |
| Resolution | 0.1 mL·mm/(cm²·h·mmHg) |
| Pressure Range | 0–500 Pa (customizable) |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.1% FS |
| Flow Range | 0–50 L/min (customizable) |
| Flow Resolution | 1 mL/min |
| Flow Accuracy | ±1% FS |
| Test Area | 16 cm² |
| Dimensions | 410 × 295 × 365 mm |
| Power Consumption | 100 W |
| Input Voltage | 110–250 VAC, 50–60 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | N600C-1 |
| Pricing | Upon Request |
| Test Principle | Differential Pressure (Manometric) Method |
| Standard Compliance | GB/T 20042.7–2014 |
| Test Range | 0–200,000 mL·mm/(cm²·h·mmHg) |
| Resolution | 0.1 mL·mm/(cm²·h·mmHg) |
| Pressure Range | 0–500 Pa (customizable) |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.1% FS |
| Flow Range | 0–50 L/min (customizable) |
| Flow Resolution | 1 mL/min |
| Flow Accuracy | ±1% FS |
| Test Area | 16 cm² |
| Dimensions | 410 × 295 × 365 mm |
| Power Consumption | 100 W |
| Input Voltage | 110–250 VAC, 50–60 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | N600C-2 |
| Quotation | Upon Request |
| Test Principle | Differential Pressure Method (ASTM D1434 / ISO 5636-5 compliant architecture) |
| Test Range | 0–200,000 mL·mm/(cm²·h·mmHg) |
| Resolution | 0.1 mL·mm/(cm²·h·mmHg) |
| Pressure Range | 0–500 Pa (customizable) |
| Pressure Resolution | 0.1 Pa |
| Pressure Accuracy | ±0.1% FS |
| Flow Range | 0–50 L/min (customizable) |
| Flow Resolution | 1 mL/min |
| Flow Accuracy | ±1% FS |
| Test Area | 16 cm² |
| Dimensions | 410 × 295 × 365 mm |
| Power Consumption | 100 W |
| Supply Voltage | 110–250 VAC, 50–60 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Model | N600L |
| Testing Methods | Gurley (1.23 kPa ± 0.01 kPa), Schopper (1.00 kPa ± 0.01 kPa or 2.50 kPa ± 0.01 kPa), Bendtsen (1.47 kPa ± 0.02 kPa) |
| Test Area Options | 6.42 cm² or 10.0 ± 0.2 cm² |
| Pressure Range | 0–3 kPa (adjustable), Accuracy: ±0.01 kPa |
| Flow Rate Range | 0.01–120 mL/min |
| Permeability Range | 0.01–2.5 µm/(Pa·s) |
| Resolution | 0.001 µm/(Pa·s) |
| Test Duration | 10–6000.0 s |
| Sample Dimensions | 50 mm × 50 mm (Gurley/Bendtsen) or 60 mm × 100 mm (Schopper) |
| Environmental Monitoring | Integrated temperature & humidity sensor |
| Seal Integrity | ≤1.0 mL/h leakage |
| Power | 100 W, 220 V, 50 Hz |
| Dimensions (L×W×H) | 500 mm × 400 mm × 300 mm |
| Compliance | SJ/T 10171–2016, GB/T 458–2008, GB/T 36363–2018 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Model | N600M |
| Testing Methods | Gurley (1.23 kPa ± 0.01 kPa), Schopper (1.00 kPa ± 0.01 kPa or 2.50 kPa ± 0.01 kPa), Bentzen (1.47 kPa ± 0.02 kPa) |
| Test Area Options | 6.42 cm² or 10.0 ± 0.2 cm² |
| Pressure Range | 0–3 kPa (adjustable, resolution 0.001 kPa) |
| Air Flow Range | 0.01–120 mL/min |
| Permeability Range | 0.01–2.5 µm/(Pa·s) |
| Resolution | 0.001 µm/(Pa·s) |
| Test Duration | 10–6000.0 s |
| Sample Dimensions | 50 mm × 50 mm (Gurley/Bentzen) or 60 mm × 100 mm (Schopper) |
| Environmental Monitoring | Integrated temperature & humidity sensor |
| Seal Integrity | ≤1.0 mL/h leakage rate |
| Power | 100 W, 220 V, 50 Hz |
| Dimensions (L×W×H) | 500 mm × 400 mm × 300 mm |
| Compliance | SJ/T 10171–2016, GB/T 458–2008, GB/T 36363–2018 |
| Brand | GBPI |
|---|---|
| Model | N900-1 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Price Range | USD 7,000 – 14,000 |
| Pressure Drop Range | 1–4000 Pa (user-selectable) |
| Measurable Air Permeability | 1–40,000 mm/s |
| Measurement Accuracy | ≤ ±2% |
| Test Area Options | 5 cm², 20 cm², 50 cm², 100 cm² |
| Sample Size | 150 mm × 150 mm |
| Max. Sample Thickness | ≤10 mm |
| Nozzle Diameters | 1.2, 2, 3, 4, 6, 8, 10, 12, 16, 20 mm |
| Dimensions (L×W×H) | 640 × 380 × 865 mm |
| Weight | 70 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | N900-2 |
| Standard Compliance | GB/T 5453–1997 |
| Pressure Drop Range | 1–4000 Pa (user-selectable) |
| Air Permeability Range | 1–40,000 mm/s |
| Measurement Accuracy | ≤ ±2% |
| Test Area Options | 5, 20, 50, 100 cm² |
| Sample Size | 150 mm × 150 mm |
| Max. Sample Thickness | ≤10 mm |
| Nozzle Diameters | 1.2, 2, 3, 4, 6, 8, 10, 12, 16, 20 mm |
| Dimensions (L×W×H) | 640 × 380 × 865 mm |
| Weight | 70 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | N900-3 |
| Price Range | USD 4,200 – 7,000 |
| Pressure Drop Range | 1–4000 Pa (user-definable) |
| Air Permeability Range | 1–40,000 mm/s |
| Measurement Accuracy | ≤ ±2% |
| Specimen Size | 150 mm × 150 mm |
| Effective Test Area | 5 cm², 20 cm², 50 cm², or 100 cm² |
| Max Sample Thickness | ≤10 mm |
| Nozzle Diameters | 1.2, 2, 3, 4, 6, 8, 10, 12, 16, 20 mm |
| Dimensions (L×W×H) | 640 × 380 × 865 mm |
| Weight | 70 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | OCY-150D |
| Quotation | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | OCY-150J |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | OPCT-40A |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | OSH-60 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | OUV-115 |
| UV Lamps | 8 × UVA-340 (1200 mm × Φ38 mm, 40 W) |
| Irradiance Range | 0.35–1.0 W/m² |
| Wavelength Range (UVA-340) | 315–400 nm |
| Sample-to-Lamp Distance | 100 ± 10 mm (adjustable) |
| Temperature Range | RT+10°C to 70°C |
| Temp. Uniformity | ±3.0°C |
| Humidity | ≥93% RH (uncontrolled display) |
| Control System | 7-inch TFT color touchscreen, programmable & fixed-mode operation |
| Data Export | USB interface, Excel (.xlsx) + JPG curve export with zoom capability |
| Internal Dimensions | W1140 × H500 × D500 mm |
| External Dimensions | W1300 × H1560 × D600 mm |
| Power Supply | AC220V ±10%, 50/60 Hz, 4.5 kW (3 kW operational), grounded (ground resistance <4 Ω) |
| Compliance Standards | GB/T 16585-1996, GB/T 14522-2008, GB/T 16422.3-2014 |
| Safety Protections | Ground fault protection, overcurrent circuit breaker, fuse-protected control loop, low-water cutoff, overtemperature cutoff, dry-heater protection |
| Sample Restrictions | Not for flammable, explosive, volatile, corrosive, biological, or high-EMI-emitting specimens |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | OUV-263 |
| Pricing | Upon Request |
| Irradiance Range | 0.35–1.0 W/m² (at 340 nm) |
| UV Lamps | 8 × UVA-340 fluorescent tubes (L = 1200 mm, Ø38 mm, 40 W |
| Optional Lamps | UVB-313 or UVA-351 |
| Spectral Range | UVA-340: 315–400 nm |
| UVB-313 | 280–315 nm |
| Lamp Center Spacing | 70 mm |
| Temperature Range | RT+10°C to 70°C |
| Temperature Uniformity | ±3.0°C |
| Humidity Level | ≥93% RH (non-regulated display) |
| Exposure Cycle Duration | 0–999 h 99 min (programmable) |
| Sample Capacity | 48 pcs (24 positions × 2 tiers |
| max. sample size | 280 × 75 mm) |
| Internal Dimensions | W280 × D75 × H? mm (per tier |
| External Dimensions | W1300 × H1560 × D600 mm |
| Power Supply | AC 220 V, 50/60 Hz, single-phase, protected earth required (ground resistance <4 Ω) |
| Installed Power | 4 kW (typical operating power: 2.8 kW) |
| Compliance Standards | GB/T 16585–1996, GB/T 14522–2008, GB/T 16422.3–2014 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | OXD-150P |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | OZQ-40 |
| Price | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCK-H |
| Pricing | Upon Request |
| Temperature Control Range | 5–99 °C (adjustable) |
| Temperature Accuracy | ≤ ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Water Uniformity | ≤ ±1 °C |
| Circulation Pump Flow Rate | 86 L/min |
| Hot/Cold Bath Volume | 50 L (optional 80 L) |
| Lifting Load Capacity | 30 kg |
| Dimensions (L×W×H) | 880 × 530 × 1300 mm |
| Power Supply | 220 V, 50 Hz |
| Heating Power | 2 × 3000 W |
| Net Weight | 50 kg |
| Compliance Standards | GB/T 4547–2007, YBB00182003–2015 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SCK-Y |
| Quotation | Upon Request |
| Standard Compliance | GB/T 4546–2008, YBB00172003–2015 |
| Pressure Range | 0.50–6.00 MPa |
| Pressure Resolution | 0.01 MPa |
| Pressure Accuracy | < ±1.5% F.S. |
| Ramp Rate Error | < ±5% |
| Cycle Time (per bottle) | ~4–10 s (depending on target pressure) |
| Max Throughput | ~1–3 bottles/min |
| Fixture Orifice Diameter | Φ24–26 mm (standard for beer bottles |
| Operating Temperature | 0–40 °C |
| Relative Humidity | < 95% RH |
| Dimensions (L×W×H) | 800 × 500 × 1000 mm |
| Weight | 45 kg |
| Power Supply | 220 V, 50 Hz |
| Included Accessories | Main Unit, Thermal Mini-Printer, Standard Bottle Fixture |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SFJ-121°C |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W201-2 |
| Price Range | USD 7,000 – 14,000 |
| Measurement Principle | Electrolytic Sensor Detection |
| Test Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0 %RH, 30–90 %RH |
| Humidity Accuracy | ±1 %RH |
| Sample Size | Ø100 mm (effective area: 50.24 cm²) |
| Max. Sample Thickness | ≤2 mm |
| Carrier Gas | Ultra-high-purity nitrogen (99.999 %), ≥0.1 MPa |
| Flow Rate | 0–100 mL/min |
| Dual Test Chambers | Independent or cross-testing capability |
| Power Supply | 220 V, 50 Hz (110 V optional) |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 80 kg |
| Compliance | GB/T 21529, ISO 15106-3, DIN 53122-2, YBB 00092003-2015, ASTM E 398 |
| Brand | GBPI |
|---|---|
| Model | W201 |
| Measurement Principle | Electrolytic Sensor Detection |
| Standard Compliance | GB/T 21529, ISO 15106-3, DIN 53122-2, YBB 00092003-2015, ASTM E 398 |
| WVTR Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control | 15–45 °C (optional up to 60 °C), ±0.1 °C accuracy |
| Humidity Control | 0% RH and 30–90% RH, ±1% RH accuracy |
| Sample Area | 50.24 cm² (Φ100 mm) |
| Max Sample Thickness | ≤2 mm |
| Carrier Gas | Ultra-high-purity N₂ (99.999%), flow 0–100 mL/min, inlet pressure ≥0.1 MPa |
| Power Supply | 220 V, 50 Hz (110 V optional) |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 80 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | W201-1 |
| Price Range | USD 7,000 – 14,000 |
| Measurement Principle | Electrolytic Sensor-Based WVTR |
| Compliant Standards | GB/T 21529, ISO 15106-3, DIN 53122-2, YBB 00092003-2015, ASTM E 398 |
| WVTR Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control | 15–45 °C (optional up to 60 °C), ±0.1 °C accuracy |
| Humidity Control | 0% RH and 30–90% RH, ±1% RH accuracy |
| Sample Area | 50.24 cm² (Φ100 mm) |
| Max. Sample Thickness | ≤2 mm |
| Carrier Gas | Ultra-high-purity N₂ (99.999%), ≥0.1 MPa supply pressure |
| Gas Flow Rate | 0–100 mL/min |
| Dual Test Chambers | Independent or cross-chamber operation |
| Data Logging | Real-time curves for WVTR, humidity, temperature, and sensor signal |
| Software Features | Automated baseline correction, dual calibration modes (standard gas + certified reference film), GLP-compliant audit trail, USB-based firmware update & data export |
| Power | 220 V, 50 Hz (110 V optional) |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 80 kg |
| Power Consumption | 500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W201-G |
| Pricing | Upon Request |
| Measurement Principle | Electrolytic Sensor Detection |
| Compliance Standards | GB/T 21529, ISO 15106-3, DIN 53122-2, YBB 00092003-2015, ASTM E 398 |
| WVTR Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0 %RH, 30–90 %RH |
| RH Accuracy | ±1 %RH |
| Sample Size | Ø100 mm (test area: 50.24 cm²) |
| Max. Sample Thickness | ≤2 mm |
| Carrier Gas | Ultra-high-purity N₂ (99.999 %), ≥0.1 MPa |
| Gas Flow Rate | 0–100 mL/min |
| Dual Test Chambers | Independent or cross-testing capability |
| Power Supply | 220 V, 50 Hz (110 V optional) |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 80 kg |
| Power Consumption | 500 W |
| Brand | GBPI |
|---|---|
| Model | W202T |
| Measurement Principle | Electrolytic Sensor Method |
| Test Range (Film/Sheet) | 0.001–100 g/m²·24h (extendable to 0.1–1000 g/m²·24h with mask) |
| Test Range (Packaged Goods) | 0.001–5 g/pkg·d |
| Resolution (Film) | 0.001 g/m²·24h |
| Resolution (Package) | 0.00001 g/pkg·d |
| Temperature Control Range | 15–45 °C (optional 5–50 °C) |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0–90 % RH (dry air to 90 % RH) |
| Humidity Accuracy | ±1 % RH |
| Sample Size | Ø80 mm (test area: 50.24 cm²) |
| Max Sample Thickness | ≤2 mm |
| Carrier Gas | High-Purity N₂ (≥99.999%, user-supplied) |
| Operating Pressure | ≥0.1 MPa |