| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HAIDA HD-A508-A Ink Rub Resistance Tester |
| Sample Area Minimum Dimensions | 250 × 80 mm |
| Rubbing Speed | (43 ± 1) cycles/min (adjustable: 21, 43, 85, 106 cycles/min) |
| Normal Load | 908 g (2 lb) and 1810 g (4 lb) |
| Stroke Length | ≈ 55 mm (center displacement of rubbing element) |
| Rubbing Area | 51 × 102 mm (L × W) |
| Cycle Count Range | 0–9999 (auto-stop) |
| Dimensions (L × W × H) | 360 × 290 × 450 mm |
| Net Weight | ≈ 30 kg |
| Power Supply | 1-phase AC 220 V, 60 W |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-A512 |
| Capacity | 300 N |
| Motor | Stepper Motor |
| Driver | Stepper Motor Driver |
| Control Interface | Touchscreen |
| Display | Touchscreen LCD |
| Transmission | Precision Ball Screw |
| Speed Range | 0.1–200 mm/min |
| Maximum Travel | 300 mm |
| Load Resolution | 1/250,000 FS |
| Load Accuracy | ≤0.5% FS |
| Effective Force Range | 5 g–30 kg (49 mN–294 N) |
| Unit Options | gf, kgf, N, kN, lbf, tonf |
| Dimensions (L×W×H) | 700 × 420 × 325 mm |
| Weight | ~50 kg |
| Power Supply | 1∮ AC 220 V, 50/60 Hz |
| Power Consumption | ~500 W |
| Compliance Standards | GB/T 12914–2018, GB/T 1040, GB 13022–1991, ISO 1924-2:2008 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-A513-B |
| Display | Touchscreen (optional PC interface) |
| Control | Touchscreen (optional software control) |
| Load Capacity | 5 kN |
| Force Resolution | 1/250,000 |
| Force Accuracy | ≤ ±0.5% |
| Max. Applied Load | 4500 N |
| Minimum Force Resolution | 0.05 N |
| Test Speed | (12.5 ± 2.5) mm/min |
| Platen Diameter | 120 mm |
| Platen Travel | 0.1–80 mm |
| RCT Specimen Size | 152 × 12.7 mm (L×W) |
| ECT Specimen Size | 100 × 25 mm (L×W) |
| Flat Crush (CMT) Guide Block | Thickness 12 mm, Ø120 mm |
| Dimensions (L×W×H) | 515 × 566 × 555 mm |
| Weight | ~70 kg |
| Power Supply | 1-phase, 220 V, 50 Hz, 2 A |
| Power Consumption | 300 W |
| Force Units | kgf, lbf, N |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HD-A513-C |
| Load Capacity Options | 500 N / 1 kN / 2 kN / 5 kN |
| Motor | 400 W Servo Motor |
| Driver | 400 W Servo Drive |
| Control System | Windows-Based PC Control |
| Display & Output | Real-time PC Interface with Export to Microsoft Office Formats |
| Actuation | Precision Ball Screw with Belt-Driven Reduction Gearbox |
| Speed Range | 0.1–500 mm/min (Adjustable) |
| Maximum Travel | 600 mm (Excluding Fixtures) |
| Load Resolution | 1/250,000 Full Scale |
| Load Accuracy | ≤ ±0.5% of Reading |
| Effective Test Force Range | 1 N – 5 kN |
| Unit Conversion | gf / kgf / N / kN / lbf / tonf |
| Effective Test Width | 420 mm |
| Dimensions (L×W×H) | ≈ 790 × 610 × 1100 mm |
| Weight | ≈ 170 kg |
| Power Supply | 1Ø AC 220 V |
| Total Power Consumption | ≈ 500 W |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-A513-E |
| Display | 7-inch Color Touchscreen |
| Load Capacity | 2 kN |
| Force Resolution | 1/250,000 full scale |
| Force Accuracy | ≤ ±0.5% FS |
| Maximum Applied Load | 1800 N |
| Minimum Force Resolution | 0.02 N |
| Test Speed | (12.5 ± 2.5) mm/min |
| Compression Plate Diameter | φ120 mm |
| Parallelism of Compression Plates | ≤ 0.06 mm |
| Plate Travel Range | 0.1–80 mm |
| RCT Specimen Size | 152 × 12.7 mm (L × W) |
| ECT Specimen Size | 100 × 25 mm (L × W) |
| Flat Crush Test (FCT) Anvil | 12 mm thick, φ120 mm |
| Dimensions (L×W×H) | 400 × 400 × 650 mm |
| Weight | ~40 kg |
| Power Supply | 1Ø AC 220 V |
| Power Consumption | ~220 W |
| Force Units | kgf, lbf, N |
| Compliance Standards | GB/T 2679.8–2016, GB/T 2679.17–1997, GB/T 6546–1998, ISO 3035:2011, TAPPI T804–2011, TAPPI T811–2007, TAPPI T809–2011, JIS P8126 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-A513-E |
| Display | 7-inch TFT Touchscreen (Dual-language UI: English/Chinese) |
| Load Capacity | 2 kN |
| Force Resolution | 0.02 N |
| Force Accuracy | ≤ ±0.5% FS |
| Load Cell Resolution | 1/250,000 |
| Test Speed | (12.5 ± 2.5) mm/min |
| Platen Diameter | φ120 mm |
| Parallelism of Platens | ≤ 0.06 mm |
| Travel Range | 0.1–80 mm |
| RCT Specimen Size | 152 × 12.7 mm (L × W) |
| ECT Specimen Size | 100 × 25 mm (L × W) |
| Flat Crush Fixture | 12 mm thick, φ120 mm |
| Dimensions (L×W×H) | 400 × 400 × 650 mm |
| Weight | ~40 kg |
| Power Supply | 1∮ AC 220 V, 50/60 Hz |
| Power Consumption | ~220 W |
| Force Units | N, kgf, lbf |
| Compliance Standards | GB/T 2679.8-2016, GB/T 2679.17-1997, GB/T 6546-1998, ISO 3035:2011, TAPPI T804-2011, TAPPI T811-2007, TAPPI T809-2011, JIS P8126 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-A519-2 MIT Fold Endurance Tester |
| Drive System | Servo Motor |
| Test Loads | 4.91 N, 9.81 N, 14.72 N |
| Folding Angle | ±135° (adjustable from 0° to ±135°, single- or double-side folding) |
| Specimen Dimensions | 15 mm × 150 mm, thickness < 1.25 mm |
| Folding Speed | (175 ± 10) rpm (0–175 ± 10 rpm adjustable) |
| Folding Head Width | 19 ± 1 mm |
| Fold Radius (Chord) | 0.38 ± 0.02 mm (interchangeable) |
| Gap Between Folding Jaws | 0.25 mm / 0.5 mm / 0.75 mm / 1.0 mm (custom gaps available) |
| Counter Range | 0–999,999 cycles, auto-stop |
| Dimensions (L×W×H) | 421 × 357 × 526 mm |
| Display | Touchscreen Interface |
| Weight | ~30 kg |
| Power Supply | 1-phase, 220 V, 50 Hz, 1 A |
| Rated Power | ~500 W |
| Compliance Standards | GB/T 457–2008, GB/T 2679.5–1995, ISO 5626:1993, JIS P 8115:2001 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HD-A534 Simulated Clamp-and-Hug Testing System |
| Capacity | 18 kN |
| Max. Sample Weight | 500 kg |
| Clamp Plate Dimensions | 1220 mm × 1220 mm (L × H) |
| Minimum Clamping Clearance | 50 mm × 1220 mm × 1220 mm (L × W × H) |
| Maximum Test Envelope | 2000 mm × 1220 mm × 1220 mm (L × W × H) |
| Clamping Speed Range | 5–500 mm/min (adjustable) |
| Parallelism Tolerance | <5 mm (unloaded), <10 mm at 1.8 t clamping force |
| Vertical Travel Range | 50–1000 mm |
| Vertical Speed (Up/Down) | 5–600 mm/min / 5–300 mm/min (adjustable) |
| Load Resolution | 1/250,000 |
| Load Accuracy | ≤ ±0.5% FS |
| Drive Motor | 750 W servo motor |
| Hydraulic Power Unit | 2.2 kW (3 HP), 40 L oil reservoir |
| Elevation Mechanism | Dual hydraulic cylinders |
| Overall Dimensions | 3250 mm × 2000 mm × 2350 mm (L × W × H) |
| Net Weight | ~3000 kg |
| Power Supply | 3-phase AC / 380 V |
| Total Power Consumption | ~3.5 kW |
| Compliance Standards | ISTA 6 – Horizontal Compression Test, ASTM D6055-2019 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HD-A535 Simulated Clamp-and-Hug Testing System |
| Load Capacity | 18 kN |
| Max. Specimen Weight | 500 kg |
| Clamp Plate Dimensions | 1220 mm × 1220 mm (L × H) |
| Minimum Clamping Space | 50 mm × 1220 mm × 1220 mm (L × W × H) |
| Maximum Clamping Space | 2000 mm × 1220 mm × 1220 mm (L × W × H) |
| Clamping Speed Range | 5–500 mm/min (adjustable) |
| Vertical Travel Range | 50–1000 mm |
| Vertical Speed (Up/Down) | 5–600 mm/min / 5–300 mm/min (adjustable) |
| Load Resolution | 1/250,000 |
| Load Accuracy | ≤ ±0.5% FS |
| Drive Motor | 750 W AC Servo Motor (Panasonic Digital Series) |
| Hydraulic Power Unit | 2.2 kW (3 HP), 40 L Oil Reservoir |
| Lifting Mechanism | Dual Hydraulic Cylinders |
| Specimen Max. Dimensions | 2000 mm × 1220 mm × 1220 mm (L × W × H) |
| Overall Dimensions | 3250 mm × 2000 mm × 2350 mm (L × W × H) |
| Net Weight | ~3000 kg |
| Power Supply | 3-phase AC / 380 V |
| Total Installed Power | ~3 kW |
| Displacement Feedback | High-precision draw-wire encoder |
| Safety Features | Mechanical stroke limit switches, electrical leakage protection, real-time fault alarm system |
| Compliance Standards | ASTM D6055, ISTA 6-SAMSCLUB, Sears Corporate Packaging Specification |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-A537 Box Sliding Angle Tester |
| Measurement Range | 0.1°–35° |
| Angular Resolution | ±0.1° |
| Tilt Speed | 2°/s |
| Test Platform Dimensions | 600 mm × 500 mm (L×W) |
| Overall Dimensions | 1100 mm × 700 mm × 1200 mm (L×W×H) |
| Weight | ~170 kg |
| Power Supply | 1∮ AC 220 V |
| Power Consumption | ~220 W |
| Compliance Standard | DIN 53119-2:1997 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-A840 Corrugating Tester |
| Working Speed | 4.5 rpm |
| Speed Accuracy | ±0.2 rpm |
| Temperature Control Range | Ambient to 200 °C |
| Standard Operating Temperature | 175 °C |
| Temperature Resolution | 1 °C |
| Temperature Accuracy | ±1% of setpoint |
| Adjustable Pressure Range | 49–108 N |
| Spring Tension | 100 N (adjustable) |
| Fluting Roller Outer Diameter | 228.5 ± 0.5 mm |
| Fluting Roller Thickness | 16 ± 0.05 mm |
| Number of Teeth | 84 |
| Tooth Profile | A-Flute |
| Upper Tooth Radius | 1.5 ± 0.1 mm |
| Lower Tooth Radius | 2.0 ± 0.1 mm |
| Flute Depth | 4.75 ± 0.05 mm |
| Sample Dimensions | 152 mm × 12.7 mm (L × W) |
| Overall Dimensions | Approx. 454 mm × 554 mm × 470 mm (L × W × H) |
| Weight | Approx. 60 kg |
| Power Supply | 1Ø AC 220 V |
| Total Power Consumption | ~1.8 kW |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-C522 Computer-Controlled Release Force Tester for Pressure-Sensitive Adhesives |
| Sensor Capacity | 10 N / 20 N / 50 N |
| Motor | 400 W Servo Motor |
| Driver | 400 W Servo Drive |
| Lead Screw | Precision Ball Screw |
| Control Mode | PC-Based Windows OS Interface |
| Adjustable Speed Range | 0.1–1000 mm/min |
| Maximum Travel | 500 mm (without fixtures) |
| Load Resolution | 1/250,000 FS |
| Load Accuracy | ≤ ±0.5% of reading |
| Force Measurement Range | 0.01–50 N |
| Unit Options | gf, kgf, N, kN, lbf, tonf |
| Dimensions (L×W×H) | 400 × 600 × 1000 mm |
| Weight | ~68 kg |
| Power Supply | 1∮ AC 220 V |
| Total Power Consumption | ~500 W |
| Standard Test | 180° Peel Release Force |
| Compliance | GB/T 2792–2014, ASTM D3330–22, GB/T 25256–2010, ISO 8510-2:2019 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-C524-12 Ambient-Temperature Tape Holding Power Tester |
| Test Stations | 12 |
| Timing Resolution | Hour-Minute (9999 h 59 min) / Hour-Minute-Second (99 h 59 min 59 s) / Minute-Second-Millisecond (99 min 59 s 59 ms) |
| Standard Load Mass | 1000 g ±5 g (including stainless steel triangular hook and hanging weight) |
| Triangular Hook Dimensions | 45 mm × 5 mm (edge length × wire diameter) |
| Standard Test Plate | 150 mm × 50 mm × 2 mm (L×W×H), SUS304 mirror-finish stainless steel |
| Surface Roughness | 50 nm ±25 nm (Ra) |
| Power Consumption | ~120 W |
| Internal Chamber Dimensions | ~987 mm × 175 mm × 430 mm (L×W×H) |
| Overall Dimensions | ~990 mm × 200 mm × 640 mm (L×W×H) |
| Weight | ~50 kg |
| Power Supply | 1∮ AC 220 V |
| Applicable Standards | GB/T 4851–2014 (Methods A, B, C), CNS 11888, PSTC-107 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-C524-6 Ambient-Temperature Tape Holding Power Tester |
| Price | Upon Request |
| Test Stations | 6 |
| Timer Resolution | 0.01 s (mm:ss:ms mode), 1 s (hh:mm mode), 1 s (hh:mm:ss mode) |
| Standard Load Mass | 1000 g ±5 g (including stainless steel triangular ring and hook weight) |
| Triangular Ring Dimensions | 45 mm × 5 mm (edge length × wire diameter) |
| Standard Test Plate | 150 mm × 50 mm × 2 mm (L×W×H), SUS304 mirror-finish stainless steel |
| Surface Roughness of Test Plate | 50 nm ±25 nm (Ra) |
| Power Consumption | ~72 W |
| Internal Chamber Dimensions | 507 mm × 175 mm × 430 mm (L×W×H) |
| Overall Dimensions | 510 mm × 200 mm × 640 mm (L×W×H) |
| Weight | ~30 kg |
| Power Supply | 1∮ AC 220 V |
| Applicable Standards | GB/T 4851–2014 (Methods A, B, C), CNS 11888, PSTC-107 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HD-C525 |
| Pricing | Available Upon Request |
| Brand | Hanatek |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CBT1 |
| Price | USD 13,500 (FOB UK) |
| Compliance Standards | BS 6965-1:1988, BS 3748, ISO 2493, TAPPI T556, DIN 53121, SCAN P29 |
| Resolution | 0.1 g |
| Accuracy | ±0.1 g |
| Measurement Range | 0–450 gf |
| Power Supply | 110/240 V AC, 50/60 Hz |
| Dimensions (H×W×D) | 230 × 175 × 250 mm |
| Net Weight | 7.6 kg |
| Packaging Weight | 10 kg |
| Sample Preparation Tools | BS 6965–compliant dedicated crease sample cutter, universal sample cutter, label printer with custom interface cable and preloaded firmware |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HANATEK CFA |
| Price | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | GTR-3 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HARKE-TQ3 |
| Pricing | Upon Request |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Compliant Standards | ISO 2556:1974, GB/T 1038–2000, ASTM D1434–75 |
| Permeation Rate Range (Chamber A) | 3–6000 cm³/(m²·d·Pa) |
| Permeation Rate Range (Chamber B) | 0.3–600 cm³/(m²·d·Pa) |
| Test Area | 38.46 cm² (Ø70 mm) |
| Specimen Size | 90 mm × 90 mm |
| Specimen Thickness Range | 10 µm – 2 mm |
| Test Gases | O₂, N₂, CO₂ |
| Pressure Differential Range | 0–10⁵ Pa |
| Pressure Measurement Accuracy | ±0.1 Pa |
| Power Supply | AC 220 V, 10 A |
| Control Interface | PC-based Windows software with real-time data logging, curve plotting, report generation (bilingual EN/CN), audit-ready export, and secure file management |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HK-100T |
| Pricing | Available Upon Request |
| Brand | HARKE |
|---|---|
| Model | HK-398A |
| Measurement Range | 0.01–1200 g/m²·24h (standard), up to 7500 g/m²·24h (optional) |
| Resolution | 0.001 g/m²·24h |
| Temperature Control Range | 5–95°C |
| Temperature Accuracy | ±0.1°C |
| Humidity Control | 0%RH, 35–90%RH, 100%RH |
| Humidity Accuracy | <±1%RH |
| Sample Quantity | 1–6 independent stations |
| Test Area | 38 cm² (standard) |
| Sample Dimensions | 150 mm × 94 mm or circular |
| Max Sample Thickness | ≤5 mm |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Gas Pressure | ≥0.16 MPa |
| Gas Flow Rate | 0–200 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 650 × 690 × 415 mm |
| Net Weight | 80 kg |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HK-701M |
| Measurement Principle | Vacuum-Pressure Differential Method |
| Test Gases | O₂, CO₂, N₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ |
| Test Range | 0.01–150,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Capacity | 1–3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range (optional) | 0%RH, 2–98.5%RH, 100%RH |
| Humidity Accuracy | ±1%RH |
| Max Sample Thickness | ≤5 mm |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Weight | 63 kg |
| Compliance | GB/T 1038–2000, ISO 15105-1, ISO 2556, ASTM D1434, JIS K 7126-1, YBB 00082003 |
| Brand | HARKE |
|---|---|
| Model | HK-701R |
| Principle | Vacuum Method (ASTM D3985, ISO 15105-2) |
| Test Range | 0.007–190,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Count | 1–3 independent stations |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH, 2–98.5% RH, 100% RH (optional humidity generator) |
| Humidity Accuracy | ±1% RH |
| Max Sample Thickness | ≤5 mm (customizable) |
| Sample Size | ≥150 mm × 94 mm or circular |
| Effective Test Area | 48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas source) |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 63 kg |
| Brand | HARKE |
|---|---|
| Model | HK-C2 |
| Application | Vacuum-Method Gas Permeability Tester for Films and Flexible Packaging Materials |
| Origin | Beijing, China |
| Manufacturer | HARKE (Domestic Producer) |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, NH₃, C₃H₈, C₄H₁₀ (hazardous gases require pre-order specification) |
| Measurement Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temp. Stability | ±0.1 °C |
| Specimen Thickness | ≤5 mm (customizable) |
| Specimen Size | ≥150 mm × 94 mm or circular |
| Effective Test Area | 48 cm² |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions | 330 mm (L) × 600 mm (D) × 330 mm (H) |
| Power | AC 220 V, 50 Hz |
| Weight | 28 kg |
| Sample Capacity | 1 specimen per test chamber |
| Multi-chamber Option | Up to 3 independent test chambers (configurable) |
| Clamping Method | Pneumatic |
| Test Modes | Proportional, Fuzzy Logic, and Time-Based Endpoint Detection |
| Expandable Range | Optional high-permeability modules available |
| Hazardous Gas Compatibility | Available with custom safety interlocks and gas-handling modules (subject to engineering review) |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HK-CV2 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HK-CV3 |
| Pricing | Available Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HK-G1 |
| Price | Upon Request |
| Measurement Principle | Vacuum-based differential pressure method (ASTM D1434 compliant) |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-order specification) |
| Standard Test Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temperature Accuracy | ±0.1 °C |
| Sample Thickness | ≤5 mm (customizable) |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Sample Quantity | 1 specimen per test |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Weight | 28 kg |
| Power | AC 220 V, 50 Hz |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HK-G106 |
| Test Principle | Vacuum Method (Manometric) |
| Measurement Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temperature Accuracy | ±0.1 °C |
| Sample Thickness | ≤5 mm (customizable) |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Gases | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-order specification) |
| Operating Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Model | HK-G3 |
| Measurement Range | 10–10,000 s/100 mL·in² at 1.22 kPa |
| Pressure Control Range | 0–20 kPa (customizable) |
| Sample Thickness Limit | ≤5 mm |
| Test Area | 0.025 in² |
| Vacuum Resolution | 0.1 Pa |
| Sample Count per Run | 1 |
| Gas Compatibility | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-consultation) |
| Interface | Ø8 mm tubing |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 68 kg |
| Control System | Embedded 32-bit ARM processor with TFT color touchscreen |
| Automation Level | Fully automatic sample clamping, pressure regulation, vacuum evacuation, and data acquisition |
| Output Parameters | Gas Transmission Rate (GTR), Permeability Coefficient (P), Diffusion Coefficient (D), Solubility Coefficient (S) |
| Brand | HARKE |
|---|---|
| Model | HK-G6 |
| Measurement Principle | Vacuum Method (Manometric) |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ |
| Permeation Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (±0.1 °C) |
| Sample Area | 48 cm² |
| Max Sample Thickness | ≤5 mm |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Chamber | Single independent chamber (configurable to triple-chamber system) |
| Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Power | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions | 330 × 600 × 330 mm (L×D×H) |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |