| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PMT-2-33 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Detector |
| Measurement Range | 0.1–1.0 µm & 0.2–2.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Piston Pump Regulation |
| Accuracy | ±5% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Support | GLP/GMP audit trail capability, FDA 21 CFR Part 11–ready software architecture (user roles, electronic signatures, data integrity logging) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-4 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–100 µm (configurable sub-ranges: 0.1–1.0 µm, 0.2–2.0 µm, 0.5–5.0 µm, 0.5–20.0 µm, 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, NIST-traceable Latex Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output,超标 alarm (customizable) |
| Data Acquisition | iPad-integrated wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Domain | High-purity acidic/alkaline process liquids, semiconductor CMP slurries, ultrapure water (UPW), electronic cleaning agents, photovoltaic etchants, TFT-LCD rinse solutions |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-41 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Spheres |
| Measurement Range | 0.1–1.0 µm, 0.2–2.0 µm, 0.5–5.0 µm (customizable from 1–100 µm or 4–70 µm(c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±5% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Output Interface | 4–20 mA analog output with customizable alarm trigger |
| Data Acquisition | iPad-integrated real-time acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Standalone Mode) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination grade classification |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-D |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.5–20.0 µm (standard) |
| Sampling Method | Precision Piston Pump with Electromagnetic Flow Control |
| Accuracy | <±1% volumetric sampling error |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Standalone Touch Interface) |
| Output | 4–20 mA analog signal,超标 alarm relay (customizable), iPad-compatible data acquisition |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-E |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, Latex Sphere Reference, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Touchscreen GUI) |
| Data Output | iPad-compatible Wireless Acquisition, 4–20 mA Analog Output, Real-time Alert Interface |
| Compliance Support | FDA 21 CFR Part 11 Audit Trail Ready (via optional software module), GLP/GMP Traceable Reporting |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-J |
| Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.065–0.2 µm & 0.1–0.5 µm (customizable to 1–100 µm or 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Calibration Standards | ISO 21501-2, JJG 1061, Latex Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP, BP, GB 8368 |
| Output Interface | 4–20 mA analog output with configurable alarm trigger |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI) |
| Operation | 7-inch color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-O |
| Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 0.05–0.2 µm, 0.1–0.5 µm, 0.2–2.0 µm (customizable from 0.1 µm to 100 µm) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±5% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output | 4–20 mA analog signal with configurable alarm thresholds |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1/2 cleanroom water monitoring, SEMI F57/F63, ASTM D6978, USP <788> & <789>, and GLP/GMP-aligned data integrity workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-r |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.5–5.0 µm (standard) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, Latex Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output with configurable alarm triggers |
| Data Acquisition | iPad-integrated wireless collection |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC version) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-T |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–1.0 µm & 0.1–0.5 µm (standard) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output with configurable alarm threshold |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination grade |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen Edition) |
| Compliance Support | FDA 21 CFR Part 11 audit trail ready (with optional configuration), GLP/GMP traceable operation |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-W |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Detection Range | 0.1–1.0 µm (standard), 0.1–0.5 µm (high-sensitivity mode), customizable 1–100 µm or 4–70 µm(c) |
| minimum detectable size | 0.1 µm(c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Data Interface | 4–20 mA analog output, touchscreen GUI + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & tablet-compatible) |
| Compliance Support | 21 CFR Part 11 audit trail (configurable), GLP/GMP-ready reporting |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting Output | Particles/mL + ISO 4406 / NAS 1638 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2-X |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.5–5.0 µm (standard) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | ISO 21501, JJG 1061, NIST-traceable latex spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output with configurable alarm threshold |
| Data Acquisition | iPad-integrated real-time acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PMT-2-Y |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Spheres |
| Detection Range | 0.1–0.5 µm, 0.2–2.0 µm |
| Customizable | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±5% (typical) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Output | 4–20 mA analog interface with configurable alarm triggers |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination等级 |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen UI) |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Data Acquisition | iPad-compatible real-time streaming |
| Compliance Support | GLP/GMP audit trail ready, 21 CFR Part 11 compliant configuration available |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-20 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–300 µm (configurable sub-ranges: 1–100 µm or 4–70 µm(c), 0.1 µm(c) optional) |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, NIST-traceable Latex Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Data Output | 4–20 mA analog interface with configurable particle-count threshold alarm |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & iPad compatible) |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-20 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.03–3000 µm (configurable) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB/T 18854, JJG 1061 |
| Sampling Accuracy | <±1% |
| Counting Accuracy | <±3% (typical) |
| Coincidence Error | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Interface | iPad-compatible acquisition module, V8.3 Analysis & Calibration Separated Software Suite (PC + embedded touchscreen) |
| Compliance Architecture | Dual-track validation mode (civilian & military-grade protocols) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Model | PMT-20 |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.05–100 µm (configurable sub-ranges: 0.05–0.2 µm, 0.1–0.5 µm, 0.1–1.0 µm) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, NIST-traceable Latex Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog,超标 alarm (customizable) |
| Data Acquisition | iPad-integrated wireless acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + Touchscreen GUI) |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Model | PMT-2A |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–100 µm (customizable sub-ranges: 0.1 µm(c), 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Compliance Standards | USP <788>, USP <789>, EP 2.9.19, BP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Data Output | 4–20 mA analog interface, iPad-compatible wireless acquisition |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + embedded touchscreen) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PMT-2C |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–0.5 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable alarm trigger |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1 cleanroom monitoring, SEMI F57, ASTM D6978, USP <788> & <789>, and GLP/GMP-aligned data integrity workflows |
| Brand | PULUODY |
|---|---|
| Model | PMT-2C |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–0.5 µm, 0.1–1.0 µm (customizable from 0.1 µm to 100 µm) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog signal with configurable alarm threshold |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1/2 cleanroom water monitoring, USP <788> & <789>, ASTM F3231, and semiconductor-grade ultrapure water (UPW) specifications per SEMI F63 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measurement Range | 0.05–0.2 µm (with customizable ranges: 1–100 µm or 4–70 µm(c), and 0.1 µm(c) selectable) |
| Sampling Method | Precision Metering Piston Pump + Electromagnetic Flow Control |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output with configurable alarm trigger |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Support | Designed for GLP/GMP-aligned workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2ccs |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measuring Range | 0.05–0.2 µm, 0.1–0.5 µm (customizable from 1–100 µm or 4–70 µm(c), down to 0.1 µm(c)) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + High-Fidelity Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, NIST-Traceable Latex Spheres |
| Compliance | USP <788>, USP <789>, EP 2.9.19, BP 2.9.19, ChP 2015 & 2020, GB 8368 |
| Data Output | 4–20 mA Analog Interface, iPad-Based Acquisition System |
| Display & Control | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 Contamination Code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Alarm Function | Configurable Threshold Alert (hardware/software-triggered) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2cs |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable alarm threshold |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Tablet-compatible) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2DC |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Piston Pump Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Spheres |
| Output Interface | 4–20 mA analog output with configurable alarm thresholds |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination等级 |
| Operating Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & iPad-compatible) |
| Compliance Support | GLP/GMP audit trail logging, FDA 21 CFR Part 11-ready configuration (optional) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2G |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Reference Spheres |
| Detection Range | 0.1–0.5 µm, 0.1–1.0 µm |
| Customizable Ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Piston Pump Regulation |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | ±5% typical |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output Interface | 4–20 mA analog output with programmable alarm threshold |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Operating Interface | Color TFT LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & embedded versions) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2GC |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres |
| Measuring Range | 0.1–1.0 µm & 0.5–5.0 µm (standard) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output with configurable alarm relay |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Control Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2J |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 0.1–0.5 µm (standard) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Piston Pump Regulation |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Output Interface | 4–20 mA analog |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + integrated embedded OS) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2K |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–0.5 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sample Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Output | Particle count per mL & ISO 4406 / NAS 1638 contamination codes |
| Interface | 4–20 mA analog output,超标 alarm (customizable) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen GUI) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PMT-2L |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 1–450 µm (standard), optional 0.03–3000 µm |
| Calibration Standards | USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2LD |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Detector |
| Measurement Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen) |
| Display | Color LCD Touch Interface + Optional Wireless Keyboard/Mouse |
| Output | 4–20 mA Analog Signal |
| Alarm Function | Configurable Threshold-Based Particle Count Alert |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 Contamination Code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Support | GLP/GMP Audit Trail Ready, FDA 21 CFR Part 11–Compatible Data Logging (via optional software module) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2LD |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 0.5–20.0 µm (standard) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog interface with configurable particle concentration alarm |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2QL |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-laser narrow-beam light scattering |
| Sensor Generation | 8th-generation dual-laser optical sensor |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision metering piston pump |
| Flow Control | Dual-stage electromagnetic + precision piston pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable alarm output |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination code |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + tablet-compatible) |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 8573-4, ASTM F3239, USP <788>, <789>, and semiconductor-grade water monitoring per SEMI F63 |