| Brand | SOOHOW INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SLPC300 |
| Instrument Type | Optical Particle Counter |
| Light Source | 670 nm semiconductor laser (5 mW) |
| Particle Size Range | 1–600 µm (sensor-dependent) |
| Sensitivity | 1 µm or 4 µm |
| Detection Channels | 8 user-configurable channels with 1-µm incremental resolution |
| Sampling Mode | Offline or online (with optional pressure regulator) |
| Sample Volume | 10 mL |
| Volume Accuracy | ±3% |
| Flow Rate (Detection & Rinse) | 30 ± 5 mL/min |
| Coincidence Error Limit | 12,000–40,000 particles/mL (sensor-dependent) |
| Counting Repeatability | RSD < 2% |
| Counting Accuracy | ±10% |
| Online Operating Pressure | 0.1–0.6 MPa (up to 40 MPa with optional pressure-reduction module) |
| Sampling Interval | 1 s to 10 h 59 min 59 s |
| Sample Temperature Range | 0–80 °C |
| Operating Ambient Temperature | −20–60 °C |
| Storage Temperature | −30–80 °C |
| Power Supply | 100–265 VAC / 24 VDC / Internal Li-ion battery |
| Brand | SOOHOW INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL-1 Online Particle Counter |
| Price Range | USD 1,100 – 1,700 (FOB) |
| Instrument Type | Optical Blockage (Light Obscuration) Particle Counter |
| Display | OLED with Membrane Touch Keypad |
| Detection Channels | 8 |
| Predefined Calibration Sizes | 1, 2, 5, 10, 15, 25, 50, 100 µm OR 4(c), 4.6(c), 6(c), 10(c), 14(c), 21(c), 38(c), 70(c) µm |
| Flow Rate Range | 10–50 mL/min and 50–300 mL/min (dual-range pump) |
| Operating Pressure | 0.2–10 MPa (up to 40 MPa with optional pressure-reduction module) |
| Data Storage | USB flash drive interface |
| Dimensions | 100 × 75 × 70 mm |
| Net Weight | 1 kg |
| Light Source | Semiconductor Laser Diode |
| Particle Size Range | 1–600 µm (sensor-dependent) |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per GB/T 18854 & ISO 11171) |
| Sample Volume per Count | 10 mL |
| Counting Accuracy | ±1 contamination code level |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −20–60 °C |
| Storage Temperature | −30–80 °C |
| Power Supply | DC 9 V or DC 12–36 V |
| Output Interfaces | RS-485, RS-232, and 4–20 mA analog output |
| Optional Add-on | Water Activity (aw) sensor for dissolved water detection in oil |
| Housing Material | Anodized Aluminum Alloy |
| Compliance Standards | ISO 4406, NAS 1638, GJB 420A/B, GB/T 14039, ROCT 17216, ISO 11171, ISO 4402, GB/T 18854-2002 |
| Brand | SOOHOW INSTRUMENT |
|---|---|
| Model | SLPC300W |
| Principle | Light Obscuration (LO) |
| Detection Range | 1–500 µm |
| Sensitivity | 1 µm (ISO 4402) / 4 µm(c) (ISO 11171, GB/T 18854) |
| Channels | 32 adjustable (0.1 µm intervals) |
| Sample Volume | 10–100 mL (±2% accuracy) |
| Flow Rate | 5–60 mL/min |
| Viscosity Limit (online) | <100 cSt (optional positive-pressure sampler for higher viscosity) |
| Pressure Range (online) | 0.1–0.6 MPa (up to 40 MPa with optional pressure reducer) |
| Temperature Range | 0–80 °C (sample), −20–60 °C (operating) |
| Water-in-Oil Range | 10–500 ppm (±5 ppm @ 10–100 ppm |
| Repeatability | RSD <2% |
| Counting Accuracy | ±10% |
| Resolution | >90% |
| Coincidence Limit | 12,000–40,000 particles/mL |
| Power | 110–240 V AC + internal Li-ion battery |
| Compliance | ISO 4402, ISO 11171, GB/T 18854, NAS1638, ISO 4406:2007, GJB420B-2015, AS4059F |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | PF1 |
| Measurable Parameter | Angle of Repose |
| Compliance | USP <1174>, Ph. Eur. 2.9.36 |
| Test Principle | Orifice Flow (Funnel-Flow) Method |
| Weight | 20 kg |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 |
| Type | Import |
| Distribution Status | Authorized Distributor |
| Pricing | Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Instrument Type | Optical Particle Counter with Direct Imaging & Ferrous Quantification |
| Technology | LaserNet Fines® |
| Compliance | ASTM D7596 |
| Measurement Principle | High-Resolution Laser Imaging + Integrated Ferromagnetic Sensor Array |
| Sample Throughput | One oil sample — full analysis in ≤ 4 minutes |
| Output Parameters | ISO 4406 & NAS 1638 cleanliness codes, particle count per size bin (≥4 µm(c), ≥6 µm(c), ≥14 µm(c), ≥21 µm(c), ≥38 µm(c), ≥70 µm(c)), ferrous concentration (ppm), ferrous particle count & size distribution (≥25 µm), automated wear debris classification (cutting, sliding, fatigue, non-metallic, fiber, water, air bubble) |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Model | SDNS300t / SDNS200t |
| Sieve Diameter × Height | Φ200 mm × 50 mm |
| Max. Sieve Layers | 8 |
| Sieve Cut Range | 6 mm – 0.045 mm |
| Stack Height | 400 mm |
| Eccentric Radius | 12.5 mm |
| Max. Sample Mass | 200 g |
| Dimensions (W×D×H) | 655×470×980 mm (SDNS300t) / 620×470×935 mm (SDNS200t) |
| Weight | 130 kg (SDNS300t) / 100 kg (SDNS200t) |
| Power | 0.37 kW |
| Supply Voltage | AC 380 V ±10%, 50 Hz ±1 Hz |
| Compliance | GB/T 474–2008 |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | HELOS & CUVETTE |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.1–3500 µm |
| Repeatability | < 0.04% |
| Measurement Time | 10 s |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Laboratory Laser Particle Size Analyzer |
| Model | HELOS & OASIS |
| Dispersion Method | Dry and Wet |
| Measurement Range | 0.1–3500 µm |
| Repeatability | 0.04% |
| Measurement Time | <10 s |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.1–3500 µm |
| Repeatability | ≤0.04% RSD |
| Measurement Time | 10 s |
| Dispersion Method | Wet Dispersion |
| Housing Material | Stainless Steel |
| Optional Accessories | Heated Circulation Module (up to 100 °C), Temperature-Controlled Jacketed Flow Cell, Multiple Flow Cell Options (2 mm and 6 mm path lengths), Integrated Ultrasonic Dispersion (0–60 W, continuously adjustable) |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HELOS & RODOS |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.1–3500 µm |
| Repeatability | ≤0.3% |
| Measurement Time | 10 s |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Product Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Model | HELOS & SPRAYER |
| Dispersion Method | Dry and Wet |
| Measurement Range | 0.25–1750 µm |
| Repeatability | Application-dependent |
| Measurement Duration | 10 s per acquisition |
| Compatible Actuator | SMACTOR Intelligent Trigger System |
| Optional Accessory | ROTOR Angular Positioning Fixture |
| Compliance Context | Designed to support FDA guidance on nasal spray characterization (e.g., Q5A(R2), Q5C, and relevant sections of USP <601> and <1601>) |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.1–875 µm |
| Repeatability | <0.04% RSD |
| Measurement Time | 10 s |
| Dispersion Method | Fully Automated Wet Dispersion (Closed-Circuit Circulation) |
| Ultrasonication | 60 W, Adjustable Power & Duration |
| Mechanical Stirring | Dual Agitators with Variable Speed Control |
| Pump | Precision Peristaltic Circulation Pump, Flow Rate Adjustable |
| Sample Cell Volume | 500 mL (Optional SVA Micro Cell: 50 mL) |
| Compliance | FDA 21 CFR Part 11 Ready Software, GLP/GMP Support Enabled |
| Construction | Full Stainless Steel Housing & Fluid Path |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–3500 µm |
| Repeatability | <0.04% |
| Measurement Time | ≤10 s |
| Optical Model | Fraunhofer and Mie Theory |
| Maximum Obscuration | 50% |
| Dispersant Compatibility | Organic solvents, aqueous media, corrosive liquids |
| Ultrasonic Power | 60 W, continuously adjustable |
| Circulation Pump | Variable-speed centrifugal pump |
| Sample Volume | 250–1000 mL |
| Integrated Cleaning Cycle | Fully automated with liquid-level monitoring |
| Optional Temperature Control | Up to 100 °C |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer | Sympatec GmbH |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–875 µm |
| Repeatability | <0.04% |
| Measurement Time | ≤10 s |
| Optical Theory | Fraunhofer and Mie |
| Maximum Obscuration | 50% |
| Disperser Volume | 400 mL |
| Ultrasonic Power | 60 W (adjustable) |
| Circulation Pump | Adjustable Peristaltic Pump |
| Optional Accessory | SVA Micro-Dispersion Unit (50 mL) |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Product Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Principle | Laser Diffraction (Mie & Fraunhofer) |
| Measurement Range | 0.25–1750 µm |
| Repeatability | <0.3% RSD |
| Measurement Time | ≤10 s per run |
| Dispersion Method | Dry & Wet |
| Inlet Configuration | Forward-feeding sample port with custom-machined mounting fixtures |
| Throat Simulation | 90° glass elbow |
| DPI-specific Pre-Separator | For carrier-lactose/active pharmaceutical ingredient (API) separation |
| Flow Control | Venturi flowmeter (differential pressure-based, 0–200 L/min) |
| Fine Particle Collection | High-efficiency fine particle collector (up to 200 L/min) |
| Wash Bottle Module | Optional wet recovery unit (up to 60 L/min) |
| Vacuum Source | Regulated vacuum pump with needle valve for precise inspiratory flow simulation |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer | Sympatec GmbH |
| Model | NANOPHOX CS |
| Particle Size Range | 0.5–10,000 nm |
| Repeatability | <2% |
| Temperature Control Range | 0–90 °C |
| Temperature Stability | ±0.1 °C |
| Measurement Principle | Polarization-Split Backscattering Photon Cross-Correlation Spectroscopy (PCCS) |
| Sample Concentration Range | 0.01–70 vol.% |
| Sample Volume | 50 µL–4 mL |
| Measurement Time | <1–3 min |
| Detection Method | PCCS & PCS dual-mode |
| Laser | 660 nm diode, Class 1, 30 mW (software-adjustable) |
| Correlator | Multi-channel, 30 ns minimum sampling time |
| Data Interface | TCP/IP |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer | Sympatec GmbH |
| Product Type | Imported Instrument |
| Model | NANOPHOX/R |
| Particle Size Range | 0.5–10,000 nm |
| Measurement Principle | Photon Cross-Correlation Spectroscopy (PCCS) |
| Temperature Control Range | 0–90 °C |
| Temperature Stability | ≤ 0.1 °C |
| Optical Signal Resolution | 30 ns |
| Sample Volume Range | 50 µL–4 mL |
| Concentration Tolerance | up to 70 vol.% (sample-dependent) |
| Light Source | 658 nm semiconductor laser, 30 mW output, software-adjustable power |
| Laser Class | Class 1 |
| Detection System | Dual PMT detectors with independent signal acquisition |
| Correlator Architecture | Multi-channel digital correlator with real-time cross-correlation processing |
| Data Acquisition Interface | TCP/IP |
| Sample Compatibility | Aqueous & organic suspensions, emulsions, microemulsions, fluorescent and colored samples |
| Measurement Time | 2–5 min per run |
| Software Compliance | Supports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | NIMBUS |
| Pricing | Upon Request |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Product Type | Imported |
| Model | QICPIC & MIXCEL |
| Instrument Category | Dynamic Image-Based Particle Analyzer |
| Number of Lenses | 6 |
| Measurement Range | 1–3000 µm |
| Dispersion Method | Wet Dispersion |
| Camera Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter, Sphericity, Aspect Ratio, Convexity, Straightness, Elongation, Perimeter Equivalent Diameter (PED), LEFI, DIFI, VBFD |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Imported Industrial-Grade Dynamic Image Analyzer |
| Model | QICPIC & FLOWCELL |
| Optical Configuration | Dual-lens imaging system |
| Measurement Range | 11–16,000 µm |
| Dispersion Method | Wet dispersion via external recirculation |
| Image Resolution | 4.2 MP (high-fidelity monochrome CMOS sensors) |
| Measured Parameters | Chord length, Feret diameters (max/min/mean), fiber length & diameter, equivalent circular diameter (ECD), sphericity, aspect ratio (width-to-length), convexity, flatness, elongation, LEFI/DIFI/VBFD indices, projected area diameter (PED) |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Dynamic Image-Based Particle Analyzer |
| Model | QICPIC & GRADIS |
| Lens Count | 5 |
| Measurement Range | 1.8–33,792 µm |
| Dispersion Method | Free-Fall Gravity Dispersion |
| Image Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter (ECD), Circularity (Sphericity), Aspect Ratio, Convexity, Flatness, Elongation, LEFI, DIFI, VBFD, PED |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Type | Dynamic Image-Based Particle Analyzer |
| Model | QICPIC & LIXELL |
| Lens Count | 6 |
| Measurement Range | 1–2000 µm |
| Dispersion Method | Wet Dispersion (External Circulation) |
| Image Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter (ECD), Sphericity, Aspect Ratio, Convexity, Flatness, Elongation, Light Extinction Feret Index (LEFI), Dynamic Image Feret Index (DIFI), Volume-Based Feret Diameter (VBFD), Projected Area Diameter (PED) |
| Brand | Sympatec |
|---|---|
| Origin | Germany |
| Manufacturer | Sympatec GmbH |
| Type | Import |
| Model | QICPIC & RODOS/L |
| Instrument Category | Dynamic Image-Based Particle Analyzer |
| Number of Lenses | 5 |
| Measurement Range | 1.8–33,792 µm |
| Dispersion Method | Pneumatic (Compressed Air) |
| Image Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter, Sphericity, Aspect Ratio, Convexity, Flatness, Elongation, Perimeter-Weighted Diameter (PED), Length-to-Width Ratio (L/W), VBFD (Volume-Based Fiber Dimension), LEFI/DIFI |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | QICPIC |
| Instrument Type | Dynamic |
| Measurement Range | 0.55–33,792 µm |
| Number of Lenses | 7 |
| Dispersion Method | Dry or Wet |
| Image Resolution | 4 Megapixels |
| Measured Parameters | Chord Length, Feret Diameter, Martin Diameter, Equivalent Spherical Diameter, Sphericity, Aspect Ratio |
| Brand | Taylor |
|---|---|
| Origin | USA |
| Model | RX-29-E, RX-30-E |
| Principle | Electromagnetic Vibration Sieving |
| Type | Laboratory Benchtop Sieve Shaker |
| Compliance | ASTM E11, ISO 3310-1, USP <786> |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Optical Microscope |
| Price Range | USD 92,000 – 132,000 |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | BM-2A |
| Instrument Type | Optical Surface Particle Counter |
| Measurement Range | 0.1–5 µm, 0.3–10 µm, 5–150 µm, 20–500 µm |
| Number of Channels | 8 |
| Channel Resolution | 0.1 µm |
| Sampling Area | 10 cm² (configurable) |
| Sampling Duration | 5–59 s (user-defined) |
| Accuracy | ≤ ±20% |
| Relative Standard Deviation (RSD) | ≤ 5% |
| Counting Capacity | 0–9,999,999 particles |
| Reporting Units | cm², m², sq.in, sq.ft |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤100 W |
| Sampling Flow Rate | 1.0 CFM (28.3 L/min) |
| Interface | RS232, USB port for U-disk storage |
| Display & Control | Color touchscreen with bilingual (English/Chinese) UI |
| Data Output | Built-in thermal printer, automatic local storage, PC connectivity |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | BM-A |
| Instrument Type | Optical Surface Particle Counter |
| Measurement Range | 0.1–5 µm, 0.3–10 µm, 5–150 µm, 20–500 µm |
| Number of Channels | 8 |
| Channel Resolution | 0.1 µm |
| Sampling Area | 10 cm² (configurable) |
| Sampling Duration | 5–59 s (user-defined) |
| Accuracy | ≤ ±20% |
| Relative Standard Deviation (RSD) | ≤ 5% |
| Count Capacity | 0–9,999,999 particles |
| Reporting Units | cm², m², sq.in, sq.ft |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤100 W |
| Sampling Flow Rate | 1.0 CFM (28.3 L/min) |
| Interface | RS232, USB port for U-disk storage |
| Display & Control | Color capacitive touchscreen |
| Data Output | Built-in thermal printer, auto-storage, GLP-compliant audit trail (timestamped, user-ID logged) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Instrument Type | Optical Surface Particle Counter |
| Measurement Principle | Laser Light Scattering & Obscuration |
| Detection Range | 5–150 µm |
| Number of Size Channels | 8 |
| Channel Resolution | 0.1 µm |
| Sampling Area | 10 cm² |
| Adjustable Sampling Duration | 5–59 s |
| Accuracy | ±20 % |
| Repeatability (RSD) | <5 % |
| Particle Count Capacity | 0–9,999,999 |
| Display Units | cm², m², sq.in, sq.ft |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10 %, 50 Hz, ≤100 W |
| Interface | RS232, USB (U-disk storage) |
| Data Security | Role-based User Management System |
| Calibration | Internal Reference Curve with Auto-Fit Algorithm |
| Compliance Support | ASTM F3212 (Standard Guide for Evaluating Particulate Contamination on Medical Device Packaging), ISO 11140 (Sterilization – Qualification of Process Indicators), GB/T 24334–2009 (Determination of Dust Specks on Paper and Paperboard) |