Petroleum Specialized Analytical Instruments
Filter
Showing 1081–1110 of 1348 results
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | LF-1 |
| Standards Compliance | GB/T 12579–1990, ASTM D892–84, JIS K2518–1991 |
| Temperature Control | Dual-bath PID system (24 °C and 93.5 °C) |
| Bath Volume | Ø300 × 460 mm each |
| Temperature Stability | ±0.2 °C |
| Heating Power | 600 W (24 °C bath), 2 × 1000 W (93.5 °C bath) |
| Cooling Input Power | 600 W |
| Working Medium | Distilled water |
| Stirring Motor Power | 25 W |
| Air Pump Power | 6 W |
| Gas Diffuser | Ø25.4 mm, pore size <80 µm, air permeability 3000–6000 mL/min |
| Graduated Cylinder | 1000 mL |
| Air Flow Rate | 94 ± 5 mL/min |
| Timer Resolution | 1 s |
| Power Supply | AC 220 V, 50 Hz |
| Total Rated Power | 3.3 kW |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | MPC-6 |
| Test Method | ASTM D6749 (Air-Pressure Method), ASTM D97, ISO 3016 |
| Sample Volume | 4.5 mL |
| Temperature Interval | 1 °C or 2 °C |
| Repeatability | Pour Point ±1 °C (1 °C interval) / ±3 °C (3 °C interval) |
| Cooling Source | Integrated Peltier Module |
| Compliance | ASTM, ISO, GLP-ready architecture |
| Data Output | Auto-generated report with timestamped test logs |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | SDL-2 |
| Standards Compliance | GB/T 7305-1987, ISO 6614:1983, ASTM D1401-1967 |
| Temperature Range | Ambient to 95 °C |
| Number of Test Stations | 5 |
| Cylinder Dimensions | Φ32 mm × 225 mm |
| Bath Dimensions | Φ300 mm × 300 mm (hardened glass) |
| Heating Power | 1.5 kW |
| Bath Stirrer Motor | AC 220 V, 25 W |
| Sample Agitator Motor | DC 24 V, 80 W |
| Timer Channels | 5 independent digital timers |
| Power Supply | AC 220 V, 50 Hz, 7.5 A |
| Control Unit Dimensions | 360 mm (W) × 400 mm (D) × 130 mm (H) |
| Test Chamber Dimensions | Φ360 mm × 590 mm (D × H) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ST1011 |
| Temperature Range | Ambient to 130 °C |
| Temperature Stability | ±0.2 °C |
| Number of Test Positions | 6 |
| Heating Power | 2 kW |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 260 × 450 × 455 mm |
| Weight | 20 kg |
| Construction | Full stainless-steel housing |
| Compliance | ASTM D130, IP 154, ISO 2160, GB/T 5096 |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | NOACK S2 |
| Price | Upon Request |
| Category | Laboratory Instrument |
| Test Parameter | Evaporation Loss of Lubricating Oils |
| Compliance Standard | ASTM D5800 |
| Dimensions (W×D×H) | 55 × 40 × 33 cm |
| Weight | 33.85 kg |
| Voltage | 220 V |
| Frequency | 50/60 Hz |
| Heating Method | Solid-State Metal Heater (Wood’s Metal-Free) |
| Vacuum System | Integrated Vacuum Pump with Automatic Control |
| Vacuum Level | 20 mm H₂O |
| Test Temperature | 250 °C (±0.1 °C accuracy) |
| Test Duration | 60 min |
| Safety Features | Over-Temperature Protection, Heat-Shield Enclosure |
| Certification | CE |
| Data Output | RS232 Serial Interface for Printer |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantum |
| Pricing | Upon Request |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SBT DC-II |
| Pricing | Upon Request |
| Dimensions (W×D×H) | 32 × 51 × 74 cm |
| Weight | ~36.3 kg |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Cooling Range | +90 °C to –45 °C (±0.1 °C stability) |
| Max. Cooling Rate | 60 °C/h |
| Heating Capability | Up to 90 °C |
| Sample Capacity | 2 simultaneous tests |
| Control | Single PC can manage up to 4 units |
| Safety Certifications | CE compliant |
| Transport Dimensions | ~81 × 76 × 104 cm |
| Transport Weight | ~125 kg |
| Compliant Standards | ASTM D5133, ASTM D7110, ILSAC GF-2 through GF-6 (A&B), API SL/SM/SN, GB 11121, SH/T 0732, JPI-5S-56-99 |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TanEV CDT |
| Product Type | Laboratory Instrument |
| Compliance Standards | ASTM D8544, SAE J3200 |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TanEV WCT |
| Product Type | Laboratory Instrument |
| Compliance | SAE J3200 (in development), ASTM method under preparation |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBR |
| Pricing | Upon Request |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBS2100E-F / TBS3000 |
| Price | Upon Request |
| Dimensions (Viscometer) | 18 × 30.5 × 35.5 cm |
| Dimensions (Control Unit) | 46 × 46 × 15 cm |
| Dimensions (Auto-sampler, optional) | 46 × 51 × 61 cm |
| Weight (Viscometer) | 15.5 kg |
| Weight (Control Unit) | 9 kg |
| Weight (Auto-sampler) | 25.4 kg |
| Voltage | 220–240 V AC |
| Frequency | 50/60 Hz |
| Sample Volume | 50 mL (recommended) |
| Test Duration per Sample | ~5–7 min |
| Temperature Range | 40 °C to 200 °C (±0.1 °C stability) |
| Shear Rate Range | 5×10⁴ s⁻¹ to 7×10⁶ s⁻¹ |
| Speed Steps | 12 discrete settings (800–8000 rpm) |
| Overtemperature Protection | Programmable safety limit |
| Compliance | CE-marked |
| Shipping Weight (Manual System) | 68 kg |
| Shipping Weight (Auto System) | 72.5 kg |
| Shipping Dimensions (Manual) | 61 × 81 × 89 cm |
| Shipping Dimensions (Auto) | 61 × 81 × 127 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBS 3000 |
| Product Type | Laboratory Instrument |
| Test Parameter | HTHS Viscosity |
| Compliance Standards | ASTM D4683, ASTM D6616, SAE J300, GB/T 6538 |
| Dimensions (W × D × H) | 66 × 66 × 48 cm |
| Weight | 38.5 kg |
| Power Supply | 100–240 VAC, ≤6 A, 50/60 Hz |
| Viscosity Range | 1–30 mPa·s (cP) |
| Sample Volume | 40 mL (recommended) |
| Test Duration per Sample | ~5–7 min |
| Auto-sampler Capacity | 1–40 samples per sequence |
| Temperature Control Setpoints | 80 °C, 100 °C, 150 °C (±0.1 °C) |
| Shear Rate Range | 5×10⁵ s⁻¹ to 3×10⁶ s⁻¹ (dependent on fluid viscosity and temperature) |
| Display | Digital touchscreen interface |
| Safety Features | Automatic torque motor and stator heater shutdown upon power interruption |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TEOST |
| Pricing | Upon Request |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TFAB |
| Product Type | Laboratory Instrument |
| Test Parameter | Foam Characteristics |
| Compliance Standards | ASTM D892, IP 146, ISO 6247 |
| Dimensions (W×D×H) | 61 × 61 × 53 cm |
| Weight | 72.5 kg |
| Power Supply | 220 V, Single-phase, 10 A, 50/60 Hz |
| Heating Medium | Forced Air |
| Motor | DC-driven, maintenance-free |
| Aeration Head | Stainless steel cylindrical head with pre-heated air supply |
| Air Flow System | Dual integrated mass flow meters |
| Air Flow Rate | 94–200 mL/min (±5 mL/min) |
| Temperature Range | 20–175 °C (±0.1 °C) |
| Test Programs | Four standardized sequences (I: 24 °C, II: 93.5 °C, III: 24 °C, IV: 150 °C) |
| Sample Volume | 200 mL |
| Test Capacity | Six 1000-mL graduated cylinders |
| Display | Touchscreen controller with real-time digital readouts, programmable alarms, and elapsed time tracking |
| Safety | Dual thermal protection (fuse + current-limiting fuse), CE certified |
| Shipping Weight/Dimensions | ~90 kg / 71 × 71 × 122 cm |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported Laboratory Instrument |
| Model | SB+2 |
| Application Scope | Lubricating Oil & Low-Temperature Fluid Characterization |
| Compliance Standards | ASTM D5133, D7110, D2983, D4684, D445, D97, D2500 |
| Temperature Range | +30 °C to –70 °C |
| Temperature Control Accuracy | ±0.1 °C (programmed), ±0.03 °C (manual) |
| Cooling Rate | 1 °C/h (for Brookfield Scan/Gel Index), Isothermal for Brotz–Feldt Viscosity |
| Bath Medium | Methanol (temperature-dependent) |
| Dimensions (W×D×H) | 48 × 61 × 69 cm |
| Net Weight | ~86 kg |
| Power Supply | 220 VAC, 50/60 Hz |
| Safety Certifications | CE |
| Transport Weight (Bath Unit) | ~123 kg |
| Transport Dimensions (Bath Unit) | 66 × 59 × 122 cm |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TS |
| Detection Principle | Combustion Microcoulometry |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur (S) |
| Measurement Range | 0.0020–500 mg absolute sulfur |
| Detection Limit | 0.020 mg/L |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D3229, ASTM D5453, ASTM D7039, ISO 20846, ISO 20884, IP 512, UOP 97, EN ISO 20846, SH/T 0689 |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 1600 |
| Pricing | Available Upon Request |
| Power Supply | 220 V / 50 Hz |
| Operating Temperature | 5–50 °C |
| Storage Temperature | –10–70 °C |
| Sulfur Detection Range | 1 ppb to 100 wt% (user-configurable) |
| Resolution | 1 ppb |
| Accuracy | ±2% of full scale |
| Repeatability | ±1% of full scale |
| Linearity | ±1% of full scale |
| Drift | <1% FS/24 h |
| Temperature Coefficient | 0.01% / °C |
| Analysis Time | <1 s per measurement |
| Interference Resistance | None (non-dispersive UV fluorescence principle) |
| Alarm Outputs | Solid-state 30 mA @ 24 V DC or mechanical relay 5 A @ 220 V AC (NO/NC configurable) |
| Display | 128 × 64 pixel monochrome LCD |
| Analog Output | Standard 4–20 mA (single channel), optional dual 4–20 mA |
| Optional Accessories | Auto-calibration module, heated sample probe & flow regulator, chemiluminescence trigger interface, data logger, process heater & temperature controller, RS-232/RS-485 serial interface, signal junction box |
| Hazardous Area Certification Options | Class I, Div. 2, Groups A–D (1700-series enclosure) |
| Dimensions (W×D×H) | 127 × 30 × 76 cm |
| Weight | 90 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP 661 |
| Temperature Control Range | Ambient to 99.9°C |
| Temperature Accuracy | ±0.3°C (bath), ±1°C (air) |
| Air Pressure Regulation Range | 0–98 kPa |
| Timing Accuracy | ±1 s |
| Display | LCD |
| Power Supply | AC 220 V ±10%, 50 Hz ±2.5% |
| Power Consumption | 1100 VA |
| Dimensions | 560 × 350 × 490 mm |
| Weight | 24 kg |
| Brand | TimePower |
|---|---|
| Model | TP 725 |
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Type | Fully Automated Ubbelohde Capillary Viscometer System |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Kinematic Viscosity Resolution | 0.00001 mm²/s |
| Power Supply | AC 220 V ±10%, 50 Hz ±10%, ≤1500 W |
| Dimensions | 370 × 300 × 650 mm |
| Weight | ~28 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP-611 |
| Detection Method | Closed-Cup Method |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 261, GB/T 3536, ASTM D92, ASTM D93 |
| Repeatability | ≤4 °C |
| Ignition Methods | Fully automatic electronic arc, gas flame, electric spark, and pilot flame ignition (user-selectable) |
| Temperature Range | −25 °C to 400 °C |
| Measurement Range | 40 °C to 370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <500 W |
| Display | 260K-color TFT LCD (480 × 272 pixels) |
| Cooling Method | Integrated forced-air cooling |
| Printer | Thermal printer, 36-character line, Chinese character support |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP-625 |
| Pricing | Available Upon Request |
| Temperature Control Range | 0–100 °C (with optional chiller for sub-ambient operation) |
| Temperature Accuracy | ±0.05 °C |
| Temperature Resolution | 0.01 °C |
| Bath Capacity | 4 test positions |
| Display | 5.0-inch capacitive touchscreen LCD |
| Control System | Microprocessor-based PID temperature regulation |
| Sensor | Imported high-stability platinum RTD (PT100) |
| Illumination | Integrated LED backlighting for capillary observation |
| Power Supply | AC 220 V ±10%, 50 Hz ±5 Hz |
| Heating Power | 1500 W |
| Dimensions (W×D×H) | 400 mm × 400 mm × 620 mm |
| Weight | 20 kg |
| Compliance | Designed and validated per ASTM D445, ISO 3104, and GB/T 265–1988 |
| Brand | Timepower |
|---|---|
| Model | TP-651 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP101 |
| Pricing | Available Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP101D |
| Pricing | Available Upon Request |
| Column Oven Temp Range | Ambient to 200 °C |
| Detector (FID) Temp Range | Ambient to 300 °C |
| Methanizer Temp | 380 °C |
| TCD Sensitivity | ≥1000 mV·mL/mg (benzene) |
| FID Detection Limit | ≤5×10⁻¹² g/s |
| TCD Baseline Noise | ≤0.1 mV |
| FID Baseline Noise | ≤1×10⁻¹² A/30 min |
| TCD Baseline Drift | ≤0.2 mV/30 min |
| FID Baseline Drift | ≤1×10⁻¹¹ A/30 min |
| Temperature Control Accuracy | ≤±0.3 °C |
| Display Resolution | 0.1 °C |
| Warm-up Stability Time | <1.5 h |
| Detection Limits | CH₄ 0.1 ppm, CO 1 ppm, CO₂ 1 ppm, H₂ 5 ppm, C₂H₂ 0.1 ppm, C₂H₄ 0.1 ppm, C₂H₆ 0.1 ppm |
| Dimensions | 620 × 445 × 485 mm |
| Weight | 31.8 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TP1050 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TP201 |
| Pricing | Upon Request |
| Detection Principle | Catalytic Bead (Pellistor) Sensor |
| Display | Backlit LCD |
| Power Supply | Rechargeable Ni-MH Battery |
| Operating Temperature | −5°C to +40°C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Storage Temperature | −20°C to +50°C |
| Detection Range | 0–100% LEL (Lower Explosive Limit) |
| Accuracy | ±5% FS |
| Response Time (T90) | ≤40 s |
| Static Current Draw | ≤110 mA |
| Alarm Current Draw | ≤160 mA |
| Backlight Current Draw | ≤130 mA |
| Dimensions | 127 × 58 × 29 mm |
| Weight | 300 g |
| Intrinsic Safety Rating | ia IICT3 |
| Sensor Type | High-Stability Catalytic Combustible Gas Sensor |
| Sample Intake | Diffusion-based |
| Compliance | GB 15322.1–2019, EN 60079-0, EN 60079-11, ATEX Directive 2014/34/EU (Category II 2G), IECEx SAA 20.0032X |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP201 |
| Pricing | Available Upon Request |
| Detection Principle | Catalytic Bead (Pellistor) Sensor |
| Operating Environment | −5 °C to +40 °C |
| Relative Humidity Range | Up to 95% RH |
| Storage Humidity | −20 °C to +50 °C |
| Power Supply | Rechargeable Ni-MH Battery (8+ hours continuous operation) |
| Detection Range | 0–100% LEL (Lower Explosive Limit) |
| Accuracy | ±5% FS |
| Response Time (T90) | ≤40 s |
| Static Current Draw | ≤110 mA |
| Alarm Current Draw | ≤160 mA |
| Backlight Current Draw | ≤130 mA |
| Dimensions | 127 × 58 × 29 mm |
| Weight | 300 g |
| Display | Backlit LCD with Digital Concentration Readout |
| Alarm Mode | Audible (≥75 dB at 30 cm) |
| Intrinsic Safety Certification | ia IICT3 |
| Sample Intake | Diffusion-based |
| Sensor Type | High-Stability Catalytic Bead (Pellistor) |
| Key Target Gases | H₂, CH₄, i-C₄H₁₀, C₃H₈, C₅H₁₂, acetylenes, alkenes, gasoline vapor, ethanol, methanol, xylene, and other combustible hydrocarbon vapors |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower |
| Country of Origin | China |
| Model | TP202 |
| Price | Upon Request |
| Measurement Range | 0–80 kV (RMS) |
| Accuracy | ±2% of reading |
| Voltage Division Ratio | 10,000:1 |
| Input Impedance | 1,000 MΩ |
| Operating Temperature | 15–35 °C |
| Relative Humidity Limit | ≤70% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤50 W |
| Dimensions | 310 × 290 × 280 mm |
| Weight | 1 kg |
| Display | 7.0-inch industrial-grade color TFT touch serial LCD (1024 × 600) |
| Battery | Rechargeable Li-ion, >8 h continuous operation |
| Environmental Rating | EMI-resistant, outdoor-capable, ruggedized enclosure |
| Compliance Reference | GB/T 507–2002 Clause 5.2.3 (auxiliary measurement device per “alternative standard method”) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TP205 |
| Pricing | Upon Request |
| Sensor Core | Vaisala DMT152 / DMT242 / DMT143 |
| Measurement Principle | Chilled-Mirror Condensation Hygrometry |
| Display | 5.7" True-Color TFT Touchscreen (Bilingual: English & Chinese) |
| Data Output | USB 2.0, RS-232 (Optional) |
| Power Supply | Rechargeable Li-ion Battery (≥8 h runtime, auto-cut-off charging protection) |
| Dimensions | 310 × 290 × 280 mm |
| Weight | 4.6 kg |
| Operating Ambient | −20 to +60 °C, 0–100 %RH |
| Sample Pressure Range | 0–10 bar (gauge) |
| Sample Flow Rate | Flow-independent measurement |
| Probe Protection | Stainless Steel Sintered Filter |
| Response Time (t₆₃% / t₉₀%) | 90 s / 450 s |
| Dew Point Range Options | −100 to 0 °C |
| Dew Point Accuracy | ±2 °C |
| Simultaneous Output Parameters | Dew Point Temperature (°C), Water Concentration (ppmᵥ), Relative Humidity (%RH), System Temperature (°C) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | TP205 |
| Measurement Principle | Chilled-Mirror Hygrometry (with Vaisala DMT242/142 Sensor Core) |
| Dew Point Range | −80 to +20 °C |
| Accuracy | ±1 °C (Td) |
| Response Time (63%/90%) | 90 s / 450 s |
| Operating Ambient | −20 to +60 °C, 0–100 %RH |
| Max Sample Pressure | 20 bar |
| Sample Flow Rate | Flow-Insensitive Design |
| Output Interface | RS232 Serial Port |
| Power Supply | Rechargeable Internal Battery (≥8 h charge time, auto-cut-off protection) |
| Probe Protection | Stainless Steel Sintered Filter |
| Display | True-Color Touchscreen (Bilingual: English/Chinese) |
| Data Handling | Real-Time Storage & Thermal Printing Capability |
| Dimensions | 310 × 290 × 280 mm |
| Weight | 4.6 kg |
| Compliance | Designed for ISO 8573-3, IEC 61215 (indirect), ASTM D6649, and GLP-aligned data integrity workflows |