| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FerroCheck 2000 |
| Price | Upon Request |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −30–85 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Weight | >3 kg |
| Dimensions | 17 cm × 20 cm × 13 cm |
| Shock & Vibration Certification | MIL-STD-810G |
| Electrical Safety | FCC Class B, CE |
| Environmental Rating | NEMA 3R, IP34 |
| Sample Type | In-service lubricating oils and hydraulic fluids |
| Measurement Principle | Magnetic susceptibility-based ferrous particle quantification |
| Response Time | ≤30 seconds per sample |
| Detectable Ferrous Particle Size Range | ~1 µm to >1 mm |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FerroCheck 2000 |
| Type | Portable Instrument |
| Detection Principle | Magnetic Susceptibility-Based Quantitative Ferrous Particle Measurement |
| Measurement Range | 0–10,000 ppm |
| Repeatability | <5 ppm |
| Particle Size Sensitivity | Nanoscale to Millimeter-Scale Ferromagnetic Particles |
| Analysis Time | <30 seconds per sample |
| Power Supply | Rechargeable Lithium-Ion Battery |
| Data Storage | Internal Non-Volatile Memory with USB Export Capability |
| Sample Requirement | No Pre-treatment or Organic Solvents Required |
| Compliance | Designed for ASTM D7684 (Standard Test Method for Quantitative Measurement of Wear Debris in Used Lubricants by Ferrography), ISO 4406, and GLP/GMP-Ready Data Traceability |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FerroCheck 2000 |
| Type | Portable Instrument |
| Compliance | ASTM D8120 |
| Detection Principle | Magnetic Susceptibility-Based Impedance Measurement |
| Sample Volume | 1.5 mL (oil), 0.75 mL (grease) |
| Analysis Time | ≤30 s |
| Detection Limit | <3 ppm Fe |
| Repeatability | ±2% RSD |
| Power | Rechargeable Li-ion battery (4 h runtime) |
| Data Output | CSV, AMS OilView-compatible |
| Calibration | Pre-loaded with certified calibration standards |
| Temperature Compensation | Automatic real-time coil current balancing |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58 |
| Product Type | Portable Instrument |
| Detection Capabilities | Elemental Analysis (XRF), Particle Counting, Kinematic Viscosity at 40 °C, FTIR-based Oxidation, Nitration, Soot, Water, TAN/TBN, Fuel & Glycol Contamination |
| Power Supply | Rechargeable Lithium-ion Battery |
| Dimensions | 487.68 × 386.08 × 228.6 mm (L × W × H) |
| Compliance | ASTM D6595, D7690, D7883, D7621, D7943, ISO 11171, ISO 4406, ISO 21468, ISO 21469, USP <1058>, FDA 21 CFR Part 11 (audit trail enabled in software) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58 |
| Power Supply | Rechargeable Lithium-ion Battery |
| Dimensions | 32 × 24 × 18 cm (L×W×H) |
| Weight | 6.8 kg |
| Analytical Methods | XRF Elemental Analysis, Differential Pressure Particle Counting (FPQ), Gravity Capillary Viscometry at 40 °C, FTIR Spectroscopy |
| Sample Volume | 3–5 mL per test |
| Test Time | <10 minutes per full suite |
| Connectivity | Wi-Fi 802.11 b/g/n, Bluetooth 5.0 |
| Compliance | ASTM D6595 (XRF), ISO 4406 / ISO 11500 (particle counting), ASTM D445 (viscosity), ASTM E2412 / D7414 (FTIR oil analysis), GLP-compliant audit trail |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | FieldLab 58 |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FluidScan 1000 |
| Product Type | Portable Instrument |
| Detection Principle | Direct Reading Infrared (DIR) Spectroscopy |
| Compliance | ASTM D7889, ASTM E2412, ASTM D4739, ASTM D664, ASTM E1655 |
| Key Parameters | TAN (mg KOH/g), TBN (mg KOH/g), Oxidation (Abs/0.1 mm), Nitration (Abs/mm²), Sulfation (Abs/mm²), Water (ppm), Glycol (%), Soot (%), FAME (%), Residual Carbon, Additive Depletion, Fuel Dilution, Oil Mismatch Index, FFA (%), Total Glycerin, Antioxidant Content (%) |
| Sample Volume | 1–2 drops |
| Measurement Time | ~60 seconds |
| Power | Rechargeable Li-ion battery (≥6 h operation) |
| Dimensions | 240 × 140 × 70 mm |
| Weight | 1.4 kg |
| Software | FluidScan Manager (PC-based, with trend analysis, asset management, automated reporting, audit trail, and data synchronization) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FluidScan 1000 |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FluidScan 1000 |
| Instrument Type | Portable Infrared Spectrometer |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Detection Targets | Water, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Contamination Index |
| Sample Volume | 1 drop (~50 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration Database | > 850 reference oils |
| Lubricant Compatibility | Mineral & synthetic engine oils, gear oils, turbine oils, hydraulic fluids, transmission fluids, greases, biodiesel, and fuel blends |
| Cleaning Method | Solvent-free |
| Measurement Principle | Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) Spectroscopy |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FluidScan 1000 |
| Product Category | Portable Instrument |
| Application Scope | In-service lubricant and grease condition monitoring |
| Compliance | ASTM D7889, JOAP Standard Practice |
| Detection Capability | Oxidation, Nitration, Sulfation, Additive Depletion, Base Number (BN), Acid Number (AN), Water Content (free & dissolved, down to 300 ppm), Glycol Contamination, Fuel Dilution, Soot Load, Oil Type Verification |
| Sample Volume | 1 drop (~25 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration | Factory-calibrated with industry-validated multivariate algorithms |
| Database | Pre-loaded spectral library of >700 commercial lubricants and greases |
| Reporting | On-device pass/fail alerts + automated PDF report generation |
| Software Integration | FluidScan Manager PC software (Windows-based) with trend analysis, fleet-level reporting, and audit-ready data export |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FluidScan 1000 Series |
| Instrument Type | Portable Analyzer |
| Measurement Parameters | Water Content, TAN (Total Acid Number), TBN (Total Base Number), Oxidation, Nitration, Sulfation, Glycol, Soot, Additive Depletion, Overall Oil Health Index |
| Compliance | ASTM D7889, ASTM E2412, ASTM E1655 |
| Sample Volume | 1 drop (~50 µL) |
| Analysis Time | < 60 seconds per sample |
| Calibration Database | > 850 reference spectra (mineral & synthetic oils, greases, biodiesel, fuels) |
| Cleaning Method | Solvent-free |
| Detection Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Portability | Handheld, battery-operated, field-deployable |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FluidScan 1100 |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FluidScan |
| Product Type | Portable Instrument |
| Detection Parameters | Contaminants, Oxidation, Acid Number (AN), Base Number (BN), Water Content (Free & Dissolved), Fluid Identity |
| Compliance | ASTM D7889, JOAP Standards |
| Measurement Principle | Mid-Infrared (MIR) Absorption Spectroscopy |
| Sample Volume | 1 Drop (~50 µL) |
| Analysis Time | ≤ 60 Seconds |
| Onboard Database | > 800 Lubricant & Grease Reference Spectra |
| Calibration | Factory-Calibrated with Industry-Validated Algorithms |
| Reporting | Automated PDF Report Generation |
| Software Integration | FluidScan Manager (Windows-based Database & Trending Software) |
| Regulatory Support | Audit Trail, User Access Control, Data Export for GLP/GMP Environments |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | InfraCal 2 ATR-E |
| Price | Upon Request |
| Measurement Principle | Attenuated Total Reflectance (ATR) Mid-Infrared Spectroscopy at 1045 cm⁻¹ (9.6 µm) |
| Ethanol Range | 0–20% and 70–98% v/v in gasoline |
| Repeatability | ±0.2% (0–20%), ±1.0% (70–98%) |
| Compliance | ASTM D4815 |
| Sample Interface | ATR crystal cell, solvent-free wipe cleaning |
| Display | Touchscreen LCD with multilingual UI (English, Spanish, French, Arabic) |
| Data Storage | Internal non-volatile memory with user, location, date/time stamping |
| Security | Password-protected calibration curves and data |
| Power | Rechargeable Li-ion battery (≥12 h operation), 18 V DC input |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Operating Environment | 5–40 °C |
| Analysis Time | <30 s per sample |
| Connectivity | USB 2.0, RS-232 |
| Calibration Options | Single or multi-point factory-certified standards (e.g., 403-1026: 0/5/10/15/20% v/v |
| 403-1027 | 70/80/90/95/100% v/v) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 ATR-E |
| Portability | Portable |
| Compliance | ASTM D4815 |
| Detection Range | 0–20% and 70–98% ethanol in gasoline |
| Repeatability | ±0.2% (0–20%), ±1.0% (70–98%) |
| Analysis Time | <30 seconds |
| Wavelength | 9.6 µm (1045 cm⁻¹) |
| Power | 18 V DC, 3.3 A |
| Battery Life | >12 hours (rechargeable Li-ion) |
| Weight | 2.6 kg (net), 3.2 kg (with battery) |
| Dimensions | 17 × 19.8 × 13.2 cm |
| Operating Temperature | 5–40 °C |
| Interface | USB, RS-232 |
| Data Storage | Internal, password-protected |
| Display | Touchscreen LCD |
| Language Support | English, Spanish, French, Arabic |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | InfraCal 2 |
| Detection Principle | Fixed-Filter Infrared Absorption (Near-IR) |
| Measurement Time | ≤10 s per sample |
| Sample Throughput | Continuous, sequential analysis |
| Power Supply | Rechargeable Li-ion battery (≥6 h operation) |
| Weight | <2.0 kg |
| Display | Touchscreen interface |
| Data Storage | Internal non-volatile memory with user, location, date/time stamps |
| Data Export | USB 2.0 port and removable USB flash drive support |
| Language Options | English, Spanish, French, Arabic |
| Calibration Security | Password-protected calibration curves and data management |
| Regulatory Alignment | Designed to support ASTM D7371 (Standard Test Method for Determination of Biodiesel (Fatty Acid Methyl Esters) in Diesel Fuel Oil by Mid Infrared Spectroscopy), ASTM D5798 (Ethanol in Gasoline), and EPA Method IO-3.2 compliance workflows |
| Software Compatibility | Standalone operation |
| Maintenance Requirements | No consumables beyond standard solvent wipes |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Spectro Scientific |
| Product Type | Imported Instrument |
| Model | LaserNet 200 |
| Pricing | Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 |
| Product Type | Laboratory Instrument |
| Particle Sizing Range | 4–100 µm |
| Max. Particle Concentration | 5,000,000 particles/mL |
| Viscosity Range (undiluted) | 15–320 cSt |
| Detection of Water Droplets & Air Bubbles | Yes |
| Compliance Standards | ISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL |
| Optional Modules | Ferrous Particle Monitoring (ppm + size distribution ≥25 µm), Morphological Imaging & Neural Network-Based Classification (≥20 µm), Kinematic & Dynamic Viscosity Measurement at 40 °C, Automated Sample Processor (ASP) for 24 samples |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 Series |
| Particle Sizing Range | 4–100 µm |
| Max. Particle Concentration | 10,000,000 particles/mL (<2% error) |
| Viscosity Compatibility | ISO VG 15–320 (no dilution required) |
| Ferrous Particle Detection Time | 20 s |
| Standards Compliance | ASTM D7596, ASTM D6786, ASTM D8120, ISO 4406, NAS 1638, SAE AS4059, NAVAIR 01-1A-17, GOST, HAL |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 Series |
| Type | Portable Instrument |
| Detection Parameters | Particle Counting, Ferrous Particle Concentration & Count (>25 µm), Morphological Wear Debris Classification, Free Water (ppm), Bubble/Contaminant Discrimination |
| Standards Compliance | ASTM D7596, ISO 4406, NAS1638, SAE AS4059, ASTM D6786, ISO 11171 |
| Imaging Technology | Direct High-Resolution CCD Imaging with Laser Illumination |
| Particle Size Range | ≥2 µm (morphology-resolved), ≥20 µm (automated classification), ≥25 µm (ferrous count) |
| Max Sample Contamination Tolerance | 5,000,000 particles/mL |
| Max Soot Tolerance | 2% w/w |
| Auto-Gain Control (AGC) | Yes |
| Onboard Data Management | Asset Tracking, Trend Analysis, Custom Cleanliness Thresholds |
| Dimensions | 35.6 cm H × 36.8 cm W × 78.7 cm D |
| Weight | 8.5 kg |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | LaserNet 230 |
| Product Category | Laboratory Instrument |
| Detection Scope | Tribological Wear & Contamination Analysis |
| Compliance | ASTM D7596, ASTM D8120, ISO 4406, NAS 1638, SAE AS4059, GOST, HAL, NAVAIR 01-1A-17 |
| Particle Sizing Range | 4–100 µm |
| Saturation Limit | ≤2% error at up to 10⁷ particles/mL |
| Viscosity Compatibility | ISO VG 15–320 (undiluted) |
| Ferrous Detection Time | 20 s |
| Ferrous Size Resolution | ≥25 µm |
| Non-Ferrous Particle Classification | ≥20 µm |
| Auto-Sampler Option | Yes (ASP, 24-position) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 230 |
| Detection Capabilities | Simultaneous particle counting, ferrous particle quantification (ppm & size distribution), and morphology-based wear debris classification |
| Particle Size Range (counting) | 4–100 µm |
| Max. Particle Concentration | 5,000,000 particles/mL |
| Viscosity Range | 15–320 cSt (no dilution required) |
| Soot Tolerance | up to 2% (w/w) |
| Counting Uncertainty | <2% (statistical repeatability) |
| Standards Compliance | ISO 4406, NAS 1638, SAE AS4059, ASTM D6786, NAVAIR 01-1A-17, GOST, HAL |
| Imaging Resolution | ≥20 µm for automated morphology classification |
| Ferrous Sensor Sensitivity | Sub-ppm detection limit for ferrous concentration |
| Analysis Time per Sample | ~4 minutes |
| Data Integration | Native export to SpectroTrack LIMS and AMS Asset Management System |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LNF220 |
| Type | Laser-based Direct Imaging Ferrography System |
| Detection Principle | Pulsed Laser Illumination + High-Speed CCD Imaging + AI-Powered Particle Classification |
| Output | Particle Count, Morphology Classification (Cutting, Sliding, Fatigue, Non-Metallic, Fiber, Bubble, Water) |
| Compliance | Designed for ASTM D7690 (Standard Practice for Analysis of Wear Debris Using Direct-Imaging Ferrography) |
| Software | Embedded Neural Network Algorithm Suite |
| Connectivity | Ethernet, USB 3.0 |
| Sample Throughput | Up to 12 samples/hour (automated mode) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MicroLab 30 |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MicroLab 30 |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MicroLab 30 |
| Detection Capabilities | Elemental Analysis (via Rotating Disc Electrode Atomic Emission Spectrometry), Infrared Spectroscopy, Kinematic Viscosity (at 40 °C and 100 °C), Acid Number, Oxidation, Nitration, Soot, Glycol, Water, Particle Count (optional module), Additive & Contaminant Elemental Profiling |
| Compliance | ASTM D7417 (Standard Test Method for Determination of Oxidation, Nitration, Soot, Glycol, Water, and Elemental Composition in Used Lubricating Oils Using Fourier Transform Infrared (FTIR) Spectroscopy, Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES), and Kinematic Viscosity) |
| Software | Embedded Expert System with >10,000 rule-based diagnostic scripts |
| Sample Throughput | ~15 minutes per sample (full suite of ASTM D7417–compliant tests) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Microlab 40 |
| Product Category | Laboratory Instrument |
| Detection Capabilities | Elemental Analysis (Wear Metals, Contaminants), Particle Counting, Viscosity, Oxidation/Nitration/Soot/Total Base Number (TBN), Glycol & Water Detection |
| Compliance | ASTM D6595 (Rotating Disc Electrode Emission Spectrometry), ISO 4406 (Particle Contamination Code), ASTM D2440 (TBN), ASTM D445 (Kinematic Viscosity), ASTM D7690 (On-Site Viscosity), FDA 21 CFR Part 11–ready Software Architecture |
| Sample Throughput | ≤15 min per sample (full suite of tests) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | Microlab 40 |
| Application | Elemental Analysis, Particle Counting, Viscosity, Oxidation/Nitration/Total Base Number (TBN), Coolant & Water Contamination, Soot Measurement |
| Compliance | ASTM D6595 (Rotary Disc Electrode Emission Spectrometry), ASTM D7690 (Automatic Particle Counting), ASTM D445 (Kinematic Viscosity), ASTM D2896/D4739 (TBN), ISO 4406:2017 (Particle Contamination Code) |
| Configuration | Benchtop, Integrated Lab-Scale Analyzer for On-Site or Centralized Lubricant Diagnostics |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MicroLab 40 |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MicroLab |
| Compliance | ASTM D7417 |
| Detection Time | ≤15 minutes per sample |
| Reporting | Full-color automated diagnostic report with visual alerting (red/yellow/green) |
| Integrated Data Sources | FerroCheck 2000 ferrographic analyzer, FDM 6001 fuel sniffing monitor |
| Software Platform | LubeTrak™ (5-year subscription included) |
| Operator Interface | Touchscreen GUI with one-touch workflow |
| Automation Level | Fully unattended sample processing (aspiration, dilution, analysis, cleaning, reporting) |