Petroleum Specialized Analytical Instruments
Filter
Showing 1051–1080 of 1348 results
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | T2FM500 |
| Application | Analytical Ferrography for Wear Particle Analysis in Lubricants, Hydraulic Fluids, Coolants, and Fuels |
| Compliance | ASTM D7684, ASTM D7690 |
| Particle Size Range | 0–800 µm |
| Operating Principle | Gravity-fed, Magnetic Deposition Ferrography |
| Sample Preparation Method | Solvent-assisted rinsing and air-drying of ferrogram slides |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Spectro Scientific |
| Country of Origin | Imported |
| Model | TruckCheck |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectrOil M |
| Pricing | Upon Request |
| Product Category | Laboratory Instrument |
| Analytical Capability | Multi-element Quantification (Metals, Additives, Contaminants) |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Model | STARDist micro |
| Sample Volume | 10 mL ± 0.3 mL |
| Analysis Time | < 10 minutes |
| Temperature Range | 0–500 °C |
| Temperature Resolution | 0.1 °C |
| Heating Power | 140 W |
| Power Supply | AC 100–240 V, 50/60 Hz, 300 W |
| Flash Point Prediction | Closed-cup flash point estimation for diesel and kerosene |
| Compliance | ASTM D7345, EN 17306, IP 596 (directly correlated to ASTM D86, ISO 3405, IP 123) |
| Operating System | Windows-based with capacitive touchscreen and stylus support |
| Form Factor | Benchtop, space-optimized design for mobile or constrained laboratories |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | SDW-150 |
| Positive Pressure Range | 0–600 kPa |
| Negative Pressure Range | 0–80 kPa |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 110–220 V, 50/60 Hz, ≤120 W |
| Integrated Pressure Sensor | Yes |
| Pressure Mode Switching | Dual-mode (positive/negative) |
| Portability | Compact, lightweight, handheld design |
| Brand | Starwood |
|---|---|
| Model | SDW-160 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Pricing | Upon Request |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | SDW-326 |
| Pricing | Available Upon Request |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | SDW-930 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SULF UV |
| Detection Target | Total Sulfur |
| Compliance Standards | ASTM D5453, AFNOR M-07-059, ISO 20846, SH/T 0689 |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | SV10 |
| Compliance | ASTM D7157 |
| Automation | Fully Automated Dilution, Titration & Cleaning |
| Temperature Control | High-Precision Patented Thermal Regulation |
| Sample Throughput | 3 Parallel Measurement Positions |
| Solvent Handling | Sealed Enclosure, Operator-Solvent Isolation |
| Application Scope | Crude Oil, Residua, Heavy Fuel Oils, Marine Bunker Fuels |
| Origin | Switzerland |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 200-Series |
| Price | Upon Request |
| Temperature Range | −10 °C to +80 °C |
| Temperature Accuracy | ±0.1 °C (external 4-wire Pt100 probe) |
| Pressure Range | Up to 200 bar (2,900 psi) |
| Pressure Accuracy | ±0.5% FS (DMS diaphragm sensor) |
| Total Volume | 450 mL |
| Recommended Liquid Fill Volume | ≤200 mL |
| Stirring Speed | 100–1,000 rpm (on/off control) |
| Optical Viewport | Sapphire window with wide-angle field of view |
| Illumination | Halogen/LED light source with fiber-optic delivery |
| Camera Resolution | 440,000 pixels (RGB/YC format) |
| Dimensions (W×D×H) | 120 × 80 × 35 cm |
| Weight | ~40 kg (excluding PC) |
| Power Supply | 230 V, 50 Hz, 2200 W |
| Origin | Switzerland |
|---|---|
| Type | Kinematic Viscosity Bath |
| Compliance | ASTM D445, IP 71 |
| Capacity | 20 L |
| Temperature Range | Ambient +5 °C to 150 °C |
| Temperature Resolution | ±0.01 °C |
| Temperature Stability | ±0.02 °C at 100 °C |
| Chamber Construction | Stainless Steel |
| Sample Ports | 5 × Ø51 mm |
| Control System | PID Digital Temperature Controller |
| Safety Features | Over/Under-Temperature Protection, Low-Level Fluid Detection |
| Sensor | PT100 Platinum Resistance Thermometer |
| Cooling | Integrated Helical Cooling Coil |
| Lid | Removable Stainless Steel Cover |
| Viewing Windows | Dual-Sided Double-Glazed (20 mm Air Gap) |
| Key | Origin: Switzerland |
|---|---|
| Model | D482 |
| Standards Compliance | ASTM D482, D874, D4422, IP 4, IP 163, ISO 3987, ISO 6245 |
| Max Operating Temperature | 1100 °C |
| Chamber Internal Dimensions (W×D×H) | 210 × 320 × 362.5 mm |
| External Dimensions (W×D×H) | 500 × 650 × 1625 mm |
| Power Supply | 220 V, 50 Hz, 3.9 kW |
| Door Type | Horizontal front-loading |
| Heating Configuration | Rear-mounted heating elements |
| Exhaust | Natural convection fume venting |
| Controller | Digital PID with safety interlocks |
| Insulation | Ceramic fiber thermal insulation |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | SYD-2806H |
| Pricing | Upon Request |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TCC-B |
| Temperature Range | Down to –90 °C |
| Bath Tank Material | Stainless Steel |
| Temperature Stability | ±0.05 °C |
| Communication Interface | RS232 Serial Port |
| Software | Included Free PC Control Software |
| Distribution Type | Authorized Distributor (Non-Manufacturer) |
| Import Status | Imported Instrument |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TFBT |
| Dimensions (L×W×H) | 280 × 350 × 620 mm |
| Weight | 11 kg |
| Power Supply | 85–264 VAC, 47–63 Hz, 40 W |
| Temperature Measurement | Range unspecified, Resolution 0.1 °C, Accuracy ±0.05 °C (IEC 751) |
| Pressure Measurement | Range 0–1500 mbar, Accuracy ±1 mbar, Nonlinearity 0.5 mbar |
| Volume Measurement | Range 0–300 mL, Linearity ±0.2 mL, Resolution ±0.5 mL |
| Timer Accuracy | ±0.001 s |
| FBT Index Range | 1.0–30 (lower values indicate better filterability) |
| Brand | Tamson Instruments |
|---|---|
| Origin | Netherlands |
| Model | TFBT |
| Standards Compliance | ASTM D2068, IP 387, SH/T 0895 |
| Test Methods | Integrated Method A & Method B |
| Display | 7-inch capacitive touchscreen with real-time pressure/flow/temperature curves |
| User Interface | Step-by-step graphical guidance |
| Calibration | Fully electronic (no mechanical adjustment required) |
| Output | Integrated thermal printer |
| Temperature Control | PID-regulated heating block (ambient to 100 °C, ±0.5 °C stability) |
| Flow Measurement | High-precision mass flow sensor (range: 0–200 mL/min, resolution: 0.1 mL/min) |
| Pressure Sensing | Digital differential pressure transducer (0–1000 kPa, accuracy: ±0.5% FS) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TV12LT |
| Temperature Range | −42 °C to +80 °C |
| Display Resolution | 0.01 °C (0.001 °C optional) |
| Test Positions | 4 |
| Bath Volume | 15 L |
| Construction Material | Stainless Steel |
| Illumination | Integrated LED Lighting |
| Cooling System | Built-in Compressor-Based Cooling |
| Observation Window | Heated, Removable Outer Pane for Easy Cleaning |
| Interface | RS232 for PC-based Temperature Programming and Data Logging |
| Standards Compliance | ASTM D445, ASTM D446, ASTM D1655, ASTM D2270, IP 71, EN ISO 3104, ISO 3105, DIN 51562 |
| Brand | TAMSON |
|---|---|
| Origin | Netherlands |
| Model | TV16000 |
| Temperature Range | 10–60 °C |
| Temperature Stability | ±0.005 °C |
| Bath Volume | 160 L |
| Temperature Resolution | 0.001 °C |
| Brand | TANAKA (Japan) |
|---|---|
| Origin | Japan |
| Model | AAP-6 |
| Standards Compliance | ASTM D611, ISO 2977, GB/T 262 |
| Temperature Range | Ambient to 160 °C |
| Heating Rate | 10 °C/min (up to 10 °C below expected aniline point), then 2 °C/min |
| Safety Cutoffs | Auto-stop at +10 °C above expected aniline point or at 170 °C (whichever occurs first) |
| Sample Handling | Modular dual-section test vessel (removable lower section for solid/semi-solid sampling and weighing) |
| Cleaning | In-situ tube cleaning without disassembly |
| Display Interface | Color-coded status indicators (standby / active test / completion) |
| Dimensions | Compact integrated footprint |
| Control System | Embedded microprocessor with repeat-test automation and no sample replacement required between runs |
| Cooling Requirement | External cooling bath or chilled vessel mandatory for ambient temperatures <20 °C |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ABL-8 |
| Test Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 21789, IP 170, ISO 13736, ISO 1516, ISO 1523 |
| Temperature Range | −30 °C to +80 °C |
| Ignition System | Dual-mode (Gas Flame & Electric Spark) |
| Repeatability | High |
| Cooling Method | Peltier-based Semiconductor Cooling |
| Display | 5.7-inch Color LCD |
| Data Storage Capacity | 200 Test Records |
| Atmospheric Pressure Compensation | Integrated Barometric Sensor |
| Safety Features | Auto Fire Suppression, Fault Diagnostics, Wind Shield Enclosure |
| Compliance Support | ASTM D3278, ISO/IEC 17025 Traceability Framework, GLP Audit Trail Ready |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACO-100 |
| Test Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ISO 2592, ASTM D92, IP 36 |
| Ignition Source | Electric or Gas Pilot Flame |
| Temperature Range | Ambient to 400 °C |
| Data Storage Capacity | 200 test records |
| Interface Options | USB, RS-232 |
| Optional Accessories | Thermal Printer, USB Keyboard, USB Flash Drive |
| Security | Password-protected test program |
| Safety Features | Auto-ignition detection, auto-extinguishing system (activated upon flash point confirmation or sustained flame ≥5 s) |
| Brand | Tanaka Scientific Instruments |
|---|---|
| Origin | Japan |
| Model | ACR-6 |
| Heating Power | 1.3 kW |
| Ignition System | Pilot Flame with Manual Lighting of Pilot Tube |
| Cooling Method | Forced Air Cooling via Fan |
| Temperature Monitoring | Thermocouple-Based Flame Detection |
| Control System | Electronic Time Relay |
| Power Supply | 100/220 V AC, 50/60 Hz, 1.4 kW |
| Compliance | ASTM D189, IP 13, GB/T 268 |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACR-M3 |
| Standards Compliance | ISO 10370, ASTM D4530, GB/T 17144 |
| Gas Flow Control | Auto-switching between 150 mL/min and 600 mL/min |
| Sample Capacity | 6 × large crucibles (5.0 g each) or 12 × small/medium crucibles (0.15–3.0 g each) |
| Heating Temperature | 500 °C ± 2 °C under inert gas atmosphere |
| Residue Weighing Resolution | 0.1 mg (requires external analytical balance) |
| Condensate Collection | Integrated high-temp resistant, explosion-proof condensate bottle |
| Front-panel Float Flowmeter | Visual flow verification and calibration support |
| Automation Level | Fully automated thermal ramping, dwell, cooling, and end-of-test audio alert (10 s) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AD-7 |
| Temperature Range | 0–450 °C |
| Condenser & Receiving Chamber Cooling | Peltier-based with internal recirculating coolant |
| Temperature Resolution | 0.1 °C |
| Condenser Temp Control Range | 0–69.9 °C (±0.2 °C accuracy) |
| Receiving Chamber Temp Control Range | 0–50 °C (±0.05 °C accuracy) |
| Distillate Rate Control | 2–10 mL/min (PID-regulated, factory default 4.5 mL/min) |
| Initial Boiling Point (IBP) Detection | Infrared photoelectric sensor |
| Dry Point Detection | Manual visual or optional automatic sensor |
| Heating System | 24 V/600 W vortex-type heater with forced-air cooling |
| Safety Systems | Flame detection sensor, automatic power cutoff, integrated fire suppressant discharge, flask support misalignment lockout, sensor fault monitoring |
| Data Storage | 5,000 test records |
| Test Method Presets | 200 programmable modes |
| Interfaces | RS-232C, Ethernet (for TDAS/LIMS), USB |
| Display | 10.4″ capacitive touchscreen LCD |
| Atmospheric Pressure Compensation | Automatic or manual input |
| Compliance | ASTM D86, ASTM D850, ASTM D1078, GB/T 6536 |
| Software | TDAS (Test Data Acquisition System) with curve export, remote operation, and printer output (thermal paper) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AFP-102 |
| Standards Compliance | ASTM D6371, IP 309, EN 116, JIS K2288, SH/T 0248 |
| Cooling Method | Integrated Peltier thermoelectric module (no formaldehyde or external chiller required) |
| Temperature Range | Ambient to –60 °C |
| Temperature Resolution | 0.1 °C |
| Cooling Modes | Linear ramp and stepwise (isothermal) cooling |
| Detection Principle | Dual-point optical meniscus tracking via LED-photodiode system with dedicated mechanical mounting bracket |
| Sample Compatibility | Diesel fuels, heating oils, biodiesel blends, and other middle distillates |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | APM-100 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D93, GB/T 261, ISO 2719 |
| Ignition Source | Dual-mode (Gas Flame & Electric Spark) |
| Temperature Range | Ambient to 370 °C |
| Data Storage Capacity | 200 test records |
| Interface | USB (for keyboard, flash drive, and LIMS export) |
| Security | Password-protected test program |
| Safety Features | Integrated thermal cutoff, flame detection interlock, and automatic lid closure |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASC-8C |
| Test Method | Closed-Cup Equilibrium Method |
| Operating Mode | Fully Automatic |
| Applicable Standards | ISO 3679, ISO 3680, ASTM D3278, ASTM D7236, IP 534 |
| Temperature Range | −30 °C to +100 °C |
| Ignition Source | Dual-mode (electric spark or gas flame) |
| Repeatability | High |
| Atmospheric Pressure Compensation | Integrated barometric sensor |
| Data Storage Capacity | 200 test records |
| Output Options | Thermal printer, USB export, LIMS integration |
| Security | Password-protected user interface |
| Compliance | Designed for GLP-compliant laboratories and routine QC environments |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASP-6 |
| Measurement Method | Ring-and-Ball (Dual-Sample) |
| Temperature Range | Ambient to 200 °C |
| Display | 5.7-inch LCD, 0.1 °C resolution |
| Temperature Sensor | PT100 platinum resistance thermometer |
| Interface | RS-232C serial port |
| Power Supply | AC 220 V, 50/60 Hz, 12 A |
| Dimensions (W×D×H) | 230 × 440 × 420 mm |
| Weight | Approx. 14 kg |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | AVP-30D2 |
| Test Range | 0–196 kPa (0–2.0 kgf/cm²) |
| Bomb Dimensions | 2/3 standard length, 1/3 standard volume |
| Pressure Sensor | Integrated semiconductor transducer |
| Display | 180 mm × 100 mm LCD |
| Oscillation | Lever-driven, ±15° tilt, 6 s cycle |
| Water Bath | Stainless steel, ~35 mL capacity, PID temperature control with motorized circulation |
| Power Supply | AC 220 V, 50/60 Hz, 15 A |
| Dimensions (W×D×H) | 400 × 600 × 740 mm |
| Weight | ~45 kg (empty bath) |