| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP553 |
| Pricing | Available Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TimePower TP553 |
| Pricing | Upon Request |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Compliance | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Display | 128×64 Graphic LCD |
| Resolution | 0.1 µg |
| Measurement Range | 3 µg – 100 mg H₂O |
| Max. Electrolysis Rate | 2.4 mg/min |
| Electrolysis Current | 0–400 mA |
| Stirring Speed | 10 adjustable levels |
| Electrolysis Gain | 10 adjustable levels |
| Data Storage | 256 timestamped records (10-year power-loss retention) |
| Interface | RS232 |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤30 W |
| Dimensions | 320 × 240 × 200 mm |
| Weight | 5 kg |
| Operating Temperature | 20–30 °C |
| Operating Humidity | ≤85% RH |
| Electrode Fault Detection | Open-circuit & short-circuit auto-diagnosis |
| Sample Compatibility | Liquids (oils, alcohols, solvents), solids (dissolved or homogenized), gases (via carrier gas adapter) |
| Accessories Included | Dual-compartment coulometric cell, 0.5 µL & 50 µL microsyringes, 1 mL glass syringe, vacuum grease, KF electrolyte (pyridine-free formulation available) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP553 |
| Pricing | Available Upon Request |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Compliance Standards | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Display | 128×64 Graphic LCD |
| Resolution | 0.1 µg |
| Detection Range | 3 µg – 100 mg H₂O |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±5% at 100 µg, ±0.5% above 100 µg (excluding sampling error) |
| Max. Electrolysis Rate | 2.4 mg/min |
| Electrolysis Current Range | 0–400 mA |
| Stirring Speed Adjustment | 10 steps |
| Electrolysis Gain Adjustment | 10 steps |
| Data Storage | 256 timestamped records with 10-year power-loss retention |
| Interface | RS232 serial port |
| Environmental Operating Conditions | 20–30 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤30 W |
| Dimensions | 320 × 240 × 200 mm |
| Weight | 5 kg |
| Electrode Fault Detection | Automatic open-circuit & short-circuit diagnostics |
| Electrolyte Compensation | Blank current compensation & endpoint drift correction |
| Cell Design | Waterproof sealed coulometric electrolytic cell with rapid equilibration |
| Safety Features | On-screen warnings for reagent exhaustion, electrode faults, and out-of-range conditions |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP572 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP572 |
| Voltage Ramp Rates | 2.0 kV/s and 3.0 kV/s (adjustable within 2.0–3.0 kV/s) |
| Measurement Range | 0–80 kV |
| Accuracy | ±2% of full scale |
| Resolution | 0.1 kV |
| Test Repetition | 1–9 cycles (default: 6) |
| Electrode Gap | Standardized per GB/T 507–1986 and DL 429.9–1991 |
| Stirring Mechanism | Magnetic stirrer with programmable agitation duration (0–59 min) |
| Standby Time | 15 min (adjustable 0–59 min) |
| Inter-test Interval | 3–5 min (adjustable 0–9 min) |
| Display | LCD panel with real-time voltage and status feedback |
| Protection | Overvoltage, overcurrent, and automatic zero-return safety interlocks |
| High-Voltage Source | Dry-type transformer assembly with sinusoidal waveform generation and stepless voltage regulation |
| Operating Environment | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Dimensions (W×D×H) | 610 × 410 × 425 mm |
| Weight | 45 kg |
| Compliance | GB/T 507–1986, DL 429.9–1991 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP575 |
| Compliance | GB/T 11142–1989, NB/SH/T 0810–2010 |
| Display | 7-inch capacitive touchscreen LCD |
| Temperature Control | 80 °C ±0.05 °C (adjustable range: ambient to 100 °C) |
| Voltage Application | 10 kV ±0.2 kV (50 Hz) |
| Test Duration | 5, 10, 50, or 120 min (automatically selected per standard) |
| Timing Accuracy | <±0.1 s |
| Hydrogen Inlet Pressure | 0.05–0.1 MPa |
| Stirring Speed | 1200 rpm |
| Temperature Resolution | 0.01 °C |
| Voltage Resolution | 0.01 kV |
| Data Storage | 1000 test records |
| Relative Humidity Limit | <85% RH |
| Heating Power | ≤1500 W |
| Total Power Consumption | ≤1700 W |
| Operating Ambient | 10–40 °C |
| Dimensions (Controller / HV Generator / Test Unit) | 320×305×195 mm / 320×305×380 mm / 320×305×590 mm |
| Safety | Integrated interlock switch, earth-grounding requirement, dry-bath protection logic |
| Output | Thermal printer (built-in) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP575 |
| Pricing | Available Upon Request |
| Display | 7-inch capacitive touchscreen LCD |
| Temperature Control Range | Ambient to 100 °C (standard test at 80 °C ± 0.05 °C) |
| Temperature Resolution | 0.01 °C |
| Test Voltage | 10 kV ± 0.2 kV (resolution: 0.01 kV) |
| Frequency | 50 Hz ± 10% |
| Test Duration Options | 5 min, 10 min, 50 min, 120 min (auto-configured per standard) |
| Timing Accuracy | < ±0.1 s |
| Hydrogen Inlet Pressure | 0.05–0.1 MPa |
| Stirring Speed | 1200 rpm |
| Ambient Operating Conditions | 10–40 °C, RH < 85% |
| Heating Power | ≤1500 W |
| Total Power Consumption | ≤1700 W |
| Dimensions (Controller / HV Generator / Test Unit) | 320×305×195 mm / 320×305×380 mm / 320×305×590 mm |
| Data Storage | 1000 test records |
| Safety Features | Grounding terminal, interlocked safety switch, dry-bath protection |
| Output | Thermal printer (integrated) |
| Compliance | GB/T 11142–1989, NB/SH/T 0810–2010 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP575 |
| Quotation | Upon Request |
| Display | 7-inch capacitive touchscreen LCD |
| Temperature Control Range | Ambient to 100 °C |
| Setpoint Accuracy | 80 °C ±0.05 °C |
| Temperature Resolution | 0.01 °C |
| Test Voltage | 10 kV ±0.2 kV |
| Voltage Resolution | 0.01 kV |
| Test Duration Options | 5 min, 10 min, 50 min, 120 min (automatically selected per standard) |
| Timing Accuracy | <±0.1 s |
| Hydrogen Inlet Pressure | 0.05–0.1 MPa |
| Stirring Speed | 1200 rpm |
| Heating Power | ≤1500 W |
| Total Power Consumption | ≤1700 W |
| Operating Ambient | 10–40 °C |
| Relative Humidity | <85% RH |
| Data Storage Capacity | 1000 test records |
| Safety Features | Interlocked high-voltage enclosure, earth-grounding requirement, automatic power cutoff on lid opening |
| Printer | Integrated thermal printer |
| Dimensions (Controller / HV Generator / Test Unit) | 320×305×195 mm / 320×305×380 mm / 320×305×590 mm |
| Accessories | Gassing cell, calibrated gas burette |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Model | TP582 |
| Origin | Beijing, China |
| Manufacturer | TimePower (Beijing Shidai Xinwei Measurement & Control Equipment Co., Ltd.) |
| Compliance | GB/T 5096, GB/T 7327, SH/T 0232, SH/T 0023, ASTM D130 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 600 W (main) + 1000 W (auxiliary) |
| Timing Range | 1 min to 24 h |
| Sample Capacity | 4–12 copper strips per test cycle |
| Dimensions | 420 × 315 × 550 mm |
| Weight | 16.8 kg |
| Power Supply | 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤1800 W |
| Operating Environment | 10–35 °C, RH ≤85% |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Quotation | Upon Request |
| Temperature Control Range | Ambient to 150 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 600 W (main) + 1000 W (auxiliary) |
| Temperature Sensor | Industrial Pt100 Platinum Resistance Thermometer |
| Timing Range | 1 min to 24 h |
| Time Display | LED digital |
| Temperature Display | 7-segment LED |
| Sample Capacity | 4 test cells (up to 12 samples per run) |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1800 W |
| Dimensions (W×D×H) | 480 mm × 360 mm × 520 mm |
| Net Weight | 18 kg |
| Compliance Standards | GB/T 5096, GB/T 7326, ASTM D130, ASTM D4048, SH/T 0232, SH/T 0023, ISO 6251 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Price | Upon Request |
| Power Supply | 220 V ±10%, 50 Hz |
| Temperature Sensor | Pt100 |
| Temperature Control Range | Ambient to 100 °C (adjustable) |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | Main heater 600 W + Auxiliary heater 1000 W |
| Timing Range | 1 min to 24 h (adjustable) |
| Sample Capacity | 4 sample wells (supports 4–12 test specimens per run) |
| Display | LED digital display for temperature and time |
| Ambient Operating Conditions | ≤35 °C, RH ≤85% |
| Overall Power Consumption | ≤1800 W |
| Dimensions | 420 × 315 × 550 mm |
| Weight | 16.8 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Quotation | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 150 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 600 W (main) + 1000 W (auxiliary) |
| Temperature Sensor | Industrial Pt100 Platinum Resistance Thermometer |
| Timing Range | 1 min to 24 h |
| Time Display | LED digital |
| Temperature Display | 7-segment LED |
| Sample Capacity | Up to 12 copper strips (4 test wells per bath, configurable multi-bath operation) |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1800 W |
| Dimensions (W×D×H) | 480 × 360 × 520 mm |
| Weight | 18 kg |
| Compliance Standards | GB/T 5096, GB/T 7326, ASTM D130, ASTM D4048, SH/T 0232, SH/T 0023, ISO 6251 |
| Brand | TimePower |
|---|---|
| Model | TP582 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | GB/T 5096, GB/T 7327, SH/T 0232, SH/T 0023, ASTM D130 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Sensor | Pt100 |
| Heating Power | Main 600 W + Auxiliary 1000 W |
| Timing Range | 1 min to 24 h |
| Sample Capacity | 4 sample wells (expandable to 12 test positions) |
| Display | LED digital display for temperature and time |
| Power Supply | 220 V ±10%, 50 Hz |
| Ambient Operating Conditions | ≤35 °C, RH ≤85% |
| Dimensions | 420 × 315 × 550 mm |
| Weight | 16.8 kg |
| Total Power Consumption | ≤1800 W |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP586 |
| Pricing | Upon Request |
| Temperature Sensor | Pt100 (JUMO Germany OEM) |
| Bath Temperature Range | 0–400 °C |
| Standardized恒温 Points & Accuracy | 150 ±1.0 °C, 180 ±1.0 °C, 250 ±1.0 °C |
| Programmable Setpoint | Yes |
| Temperature Control Accuracy | ±1 °C |
| Oil Bath Dimensions | Φ200 × 220 mm |
| Power Consumption | <2500 W |
| Rated Current | 10 A |
| Test Port Count | 3 |
| Thermometer Range | –5 to 400 °C, Graduation: 1.0 °C |
| Air Flowmeter Range | 40–70 L/min |
| Ambient Operating Conditions | 10–40 °C, RH 30–80% |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Net Weight | 45 kg |
| Overall Dimensions | 400 × 350 × 450 mm |
| Compliance Standards | GB/T 509, GB/T 8019 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP611 |
| Detection Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 261, ASTM D93 |
| Repeatability | ≤4 °C |
| Ignition Methods | Fully automatic electronic arc, gas flame, electric spark, pilot flame, and manual ignition modes |
| Temperature Range | −25 °C to 400 °C |
| Measurement Range | 40 °C to 370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <500 W |
| Display | 260K-color TFT LCD (480×272) |
| Cooling Method | Integrated forced-air cooling |
| Printer | Thermal printer (36-character Chinese/English support) |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup (ASTM D93 / GB/T 261) |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Display | 260k-color TFT LCD (480×272) |
| Cooling | Integrated forced-air cooling |
| Printer | Thermal printer (36-character Chinese/English support) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Environmental Operating Range | 5–40 °C, RH ≤85% |
| Atmospheric Pressure Compensation | Yes |
| Ignition Options | Switchable gas flame scanning or electronic spark ignition |
| Safety Features | Over-temperature cutoff, self-diagnostic system, automated test arm retraction |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP611 |
| Detection Method | Closed-Cup Method |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Display | 260k-color TFT LCD (480×272) |
| Cooling Method | Integrated Forced-Air Cooling |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Atmospheric Pressure Compensation | Yes |
| Ignition Options | Gas flame scanning or electronic spark ignition (user-selectable) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup (ASTM D93 / GB/T 261 compliant) |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Display | 260k-color TFT LCD (480×272) |
| Cooling | Integrated forced-air cooling |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup (ASTM D93 / GB/T 261) |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Display | 260k-color TFT LCD (480×272) |
| Cooling | Integrated forced-air cooling |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Environmental Operating Conditions | 5–40 °C, RH ≤85% |
| Safety Features | Over-temperature cutoff, self-diagnostic system, atmospheric pressure compensation, flame detection lockout |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP611 |
| Detection Method | Closed-Cup Method |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity | ≤85% |
| Display | 260k-color TFT LCD (480×272) |
| Cooling Method | Integrated forced-air cooling |
| Printer | Thermal printer (36-character width, Chinese character support) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup Method |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Display | 260k-color TFT LCD (480×272) |
| Cooling Method | Integrated forced-air cooling |
| Printer | Thermal printer (36-character Chinese/English output) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Atmospheric Pressure Compensation | Yes |
| Ignition Modes | Switchable gas flame scanning or electronic spark ignition |
| Safety Features | Over-temperature cutoff, self-diagnostic system, ventilation cabinet operation requirement |
| Environmental Operating Conditions | 5–40 °C, RH ≤85% |
| Compliance Standards | GB/T 261, ASTM D93 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup (Pensky-Martens / Tag Closed Cup) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 261, GB/T 3536, ASTM D92, ASTM D93 |
| Repeatability | ≤4 °C |
| Ignition Methods | Fully automatic electronic arc ignition, manual gas flame ignition, electric spark ignition, pilot gas flame ignition, and user-selectable scanning modes |
| Temperature Range | Ambient to 400 °C (standard configuration) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP611 |
| Detection Method | Closed-Cup Method |
| Standards Compliance | GB/T 261, ASTM D93 |
| Measurement Range | 40–370 °C |
| Accuracy | ±1 °C (for flash point < 110 °C) |
| Repeatability | ≤2 °C |
| Resolution | 0.1 °C |
| Display | 260k-color TFT LCD (480 × 272) |
| Cooling Method | Integrated Forced-Air Cooling |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10 %, 50 Hz ±10 % |
| Power Consumption | ≤500 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 13.5 kg |
| Environmental Operating Conditions | 5–40 °C, RH ≤85 % |
| Safety Features | Overtemperature cutoff, self-diagnostic system, atmospheric pressure compensation, flame-scan mode selection (gas or electronic ignition) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP611 (Open-Cup) / TP612 (Closed-Cup) |
| Detection Method | Cleveland Open-Cup (ASTM D92) and Pensky-Martens Closed-Cup (ASTM D93, GB/T 261) |
| Operation Mode | Fully Automatic |
| Temperature Range | 40–370 °C |
| Ignition Method | Motorized Electronic Igniter with Precise Positioning |
| Repeatability | ≤2 °C |
| Accuracy | ±1 °C for flash point <110 °C |
| Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH (non-condensing) |
| Display | 5.0-inch capacitive touchscreen, Chinese UI |
| Cooling Method | Integrated High-Flow Air Cooling System |
| Printer | Thermal printer, 36-character line, Chinese character support |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions (W×D×H) | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Included Accessories | Standard test cup (ASTM E1–compliant), motorized ignition arm, LPG gas regulator assembly (for butane/propane), calibration certificate |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower |
| Country of Origin | China |
| Model | TP612 |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536, ASTM D92 |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Temperature Sensor | Pt100 (stainless steel sheath) |
| Ignition Modes | Adjustable gas flame scanning or electronic arc ignition |
| Atmospheric Pressure Compensation | Yes |
| Cooling Method | Integrated forced-air cooling |
| Display | 480×272 TFT color LCD (260K colors) |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Environmental Operating Conditions | 5–40 °C, RH ≤85% |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Type | Domestic |
| Model | TP612 |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536, ASTM D92 |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Temperature Sensor | Imported Pt100 (stainless steel sheath) |
| Ignition Options | Adjustable gas flame scanning or electronic arc ignition |
| Atmospheric Pressure Compensation | Yes |
| Safety Features | Over-temperature cutoff, self-diagnostic system, automatic test arm retraction |
| Cooling Method | Integrated high-efficiency air cooling |
| Display | 480×272 TFT color LCD (260K colors) |
| Printer | Thermal, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Operating Environment | 5–40 °C, RH ≤85% |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Model | TP612 |
| Detection Method | Cleveland Open-Cup (COC) |
| Standards Compliance | GB/T 3536, ASTM D92 |
| Measurement Range | 79–370 °C |
| Accuracy | ±2 °C |
| Repeatability | ≤4 °C |
| Resolution | 0.1 °C |
| Temperature Sensor | Pt100 (stainless steel sheath) |
| Ignition Options | Adjustable gas flame scanning or electronic arc ignition |
| Atmospheric Pressure Compensation | Yes |
| Safety Features | Over-temperature cutoff, self-diagnostic system, automatic test arm retraction |
| Cooling Method | Integrated forced-air cooling |
| Display | 5.0-inch capacitive touch LCD (Chinese UI) |
| Printer | Thermal printer, 36-character Chinese/English output |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤600 W |
| Dimensions | 350 × 310 × 300 mm |
| Weight | 14.5 kg |
| Environmental Operating Conditions | 5–40 °C, RH ≤85% |