Petroleum Specialized Analytical Instruments
Filter
Showing 1201–1230 of 1348 results
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP652 |
| Pricing | Upon Request |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.5 °C |
| Air Flow Rate | 16–160 mL/min (adjustable via rotameter) |
| Air Source | Integrated quiet air pump (3 L/min) |
| Gas Diffusion Head Capacity | 3000–6000 mL/min at 2.45 kPa |
| Timing Resolution | ±1 s (automated) |
| Display | LCD interface |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max Power Consumption | ≤2300 W |
| Dimensions (W×D×H) | 340 × 340 × 740 mm |
| Net Weight | 23 kg |
| Operating Ambient | 5–40 °C, ≤85% RH |
| Printer | Thermal, 36-character Chinese/English output |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP652 |
| Temperature Control Range | 0 °C to 100 °C |
| Temperature Accuracy | ±0.5 °C |
| Air Flow Rate | 16–160 mL/min (adjustable via rotameter) |
| Air Source | Integrated silent air pump, 3 L/min output |
| Gas Diffusion Head Capacity | 3000–6000 mL/min at 2.45 kPa |
| Timing Resolution | ±1 s (automated) |
| Display | LCD interface |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤2300 W |
| Dimensions (W×D×H) | 340 × 340 × 740 mm |
| Net Weight | 23 kg |
| Operating Environment | 5–40 °C, RH ≤85% |
| Compliance | GB/T 12579, ISO 6247, ASTM D892 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP652 |
| Pricing | Upon Request |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.5 °C |
| Air Flow Rate | 16–160 mL/min (adjustable via rotameter) |
| Air Source | Integrated silent air pump (3 L/min) |
| Gas Diffusion Head Flow Capacity | 3000–6000 mL/min at 2.45 kPa |
| Timing Resolution | ±1 s (automated) |
| Display | LCD interface |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max Power Consumption | ≤2300 W |
| Dimensions | 340 × 340 × 740 mm |
| Net Weight | 23 kg |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Compliance Standards | GB/T 12579, ISO 6247, ASTM D892 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP652 |
| Pricing | Upon Request |
| Temperature Control Range | 0–100 °C (with optional immersion chiller) |
| Temperature Accuracy | ±0.5 °C |
| Air Flow Rate | 16–160 mL/min (adjustable via rotameter) |
| Air Source | Integrated silent air pump (3 L/min) |
| Gas Diffusion Head Capacity | 3000–6000 mL/min at 2.45 kPa |
| Timing Resolution | ±1 s (automated) |
| Display | LCD interface |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤2300 W |
| Dimensions | 340 × 340 × 740 mm |
| Net Weight | 23 kg |
| Operating Ambient | 5–40 °C, ≤85% RH |
| Printer | Thermal, 36-character Chinese/English output |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP653 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP653 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TP653 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Detection Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±5% at 100 µg, ±0.5% above 100 µg (excluding sampling error) |
| Electrolysis Current Control | 0–400 mA, auto-regulated |
| Display | 5.6-inch color TFT LCD touchscreen |
| Interface | RS-232 for balance & PC connectivity |
| Data Storage | Method storage for up to 6 pre-configured protocols (12 total methods) |
| Environmental Operating Conditions | 20–30 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10%, max. 40 W |
| Dimensions | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Electrolytic Cell | Hermetically sealed, low-equilibration-time design |
| Input Methods | Touchscreen + tactile membrane keys |
| Peripheral Support | Integrated micro-thermal printer, optional balance/PC synchronization |
| Compliance | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP653 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Display | 5.6-inch color touchscreen LCD |
| Electrolysis Current Range | 0–400 mA (auto-controlled) |
| Detection Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±3 µg (for 3 µg–1 mg) |
| Operating Temperature | 20–30 °C |
| Operating Humidity | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤40 W |
| Dimensions | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP653 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP653 |
| Pricing | Upon Request |
| Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±5% at 100 µg, ±0.5% above 100 µg (excluding sampling error) |
| Electrolysis Current Control | 0–400 mA, auto-regulated |
| Display | 5.6-inch color TFT-LCD touchscreen |
| Operating Temperature | 20–30 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤40 W |
| Dimensions (W×D×H) | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Sample Introduction | Manual syringe injection (0.5 µL / 50 µL / 1 mL), compatible with analytical balance input |
| Data Interface | RS-232 for balance & PC connectivity |
| Printer | Integrated thermal mini-printer |
| Compliance | GB/T 7600, GB/T 6283, SH/T 0246, SH/T 0255 |
| Sample Forms | Liquids, solids, gases |
| Electrolyte System | Iodine-generating coulometric cell with pyridine-free reagent option (SO₂, methanol, iodine precursor) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Type | Coulometric Titrator |
| Model | TP653 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Water Range | 3 µg – 100 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±20% at 3 µg, ±10% at 10 µg, ±1% at 100 µg, ±0.5% above 100 µg (excluding sample handling error) |
| Electrolysis Current | 0–400 mA |
| Display | Backlit Chinese LCD |
| Data Storage | Internal non-volatile memory |
| Printer | Thermal, 36-character Chinese/ASCII output |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <200 W |
| Dimensions (W×D×H) | 310 × 315 × 215 mm |
| Weight | 3.5 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Measurement & Control Co., Ltd. |
| Model | TP653 |
| Titration Method | Coulometric Karl Fischer |
| Electrolysis Current Range | 0–400 mA |
| Water Measurement Range | 3 µg – 100 mg |
| Resolution | 0.1 µg |
| Accuracy | ±20% at 3 µg H₂O |
| Display | Chinese-language LCD |
| Printer | Thermal, 36-character, Chinese-capable |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <40 W |
| Dimensions | 300 × 290 × 200 mm |
| Weight | 3.7 kg |
| Compliance | GB/T 1600, GB/T 7600, GB/T 683, GB/T 11133, SH/T 0246, SH/T 0255 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP655 |
| Pricing | Upon Request |
| Display | 480×272 color LCD, Chinese GUI |
| Control System | Microprocessor-based |
| Temperature Control | PID-regulated |
| Temp Range | 0–100 °C (with optional immersion chiller for sub-ambient operation) |
| Temp Accuracy | ≤ ±0.1 °C |
| Temp Resolution | 0.1 °C |
| Bath Capacity | Dual-sample wells |
| Stirring Speed | 1200 ± 12 rpm |
| Power Supply | AC 220 V ± 10 %, 50 Hz ± 10 % |
| Heating Power | ≤ 1500 W |
| Total Power Consumption | ≤ 1800 W |
| Dimensions | 510 × 365 × 470 mm |
| Weight | 20 kg |
| Ambient Operating Conditions | 5–40 °C, ≤ 85 % RH |
| Compliance | Designed per GB/T 1884–2000 (equivalent to ASTM D1298 and ISO 3675) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP 655 |
| Pricing | Upon Request |
| Temperature Control Range | 0–110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating Power | ≤1500 W |
| Total Power Consumption | 1800 W |
| Dual-Sample Capacity | 2 independent test positions |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Electrical Supply | AC 220 V ±10%, 50 Hz ±10% |
| Dimensions (W×D×H) | 510 × 365 × 470 mm |
| Net Weight | 20 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP656 |
| Heating Power | 200 W |
| Temperature Control Accuracy | ≤ ±1 °C |
| Magnetic Stirring Power | 3 W |
| Electric Stirring Power | 30 W |
| Magnetic Stirring Speed Range | 0–2400 rpm |
| Electric Stirring Speed Range | 0–3000 rpm |
| Total Power Consumption | ≤ 1200 W |
| Supply Voltage | AC 220 V ±10%, 50 Hz ±10% |
| pH Meter Range | 0.00–14.00 pH |
| pH Meter Accuracy | ±0.02 pH |
| pH Resolution | 0.01 pH |
| pH Repeatability | ≤1% |
| pH Stability | ±1% F.S./4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Compensation Range | 0.1–60.0 °C |
| Sample Temperature Range | 5–60 °C |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Brand | TimePower |
|---|---|
| Model | TP662 |
| Origin | Beijing, China |
| Manufacturer | TimePower Instruments Co., Ltd. |
| Type | Benchtop Automated ASTM D86 / ISO 3405 Compliant Distillation System |
| Temperature Range | 0–400 °C |
| Temperature Resolution | 0.1 °C |
| Distillate Volume Range | 0–100 mL |
| Volume Measurement Accuracy | ±0.1 mL |
| Condensate Chamber Temp Control | 10–40 °C |
| Cold Bath Temp Range | 0–60 °C |
| Ambient Operating Conditions | 10–35 °C, 10–70% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Max Power Consumption | 2 kW (adjustable) |
| Dimensions | 500 × 500 × 600 mm |
| Weight | 50 kg |
| Certified Compliance | ASTM D86, ISO 3405, GB/T 6536, IP 123 |
| Sensor | Pt100 Platinum Resistance Thermometer (DIN Class A) |
| Refrigeration | Secop (Danfoss) Hermetic Compressor |
| Optical Detection | Imported Photoelectric Volume Tracker |
| Atmospheric Pressure Compensation | Integrated Barometric Sensor with Real-Time Standardization to 101.3 kPa |
| Safety | Manual Nitrogen Purge Activation for Flash Fire Suppression |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Co., Ltd. |
| Model | TP662 |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Measurement Range | 1–111 mL |
| Volume Resolution | 0.1 mL |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Co., Ltd. |
| Model | TP662 |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Measurement Range | 1–111 mL |
| Volume Resolution | 0.1 mL |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower |
| Model | TP662 |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Detection Range | 1–111 mL |
| Volume Resolution | 0.1 mL |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Model | TP662 |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Measurement Range | 1–111 mL |
| Volume Resolution | 0.1 mL |
| Brand | TimePower |
|---|---|
| Model | TP662 |
| Origin | Beijing, China |
| Manufacturer | TimePower |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Measurement Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Brand | TimePower |
|---|---|
| Model | TP662 |
| Origin | Beijing, China |
| Manufacturer | TimePower (Producer) |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Measurement Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Model | TP662 |
| Temperature Range | 0–400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–60 °C |
| Distillation Rate | 1–11 mL/min |
| Volume Measurement Range | 1–111 mL |
| Volume Resolution | 0.1 mL |
| Atmospheric Pressure Compensation | Automatic |
| Recovery Chamber Temperature Control | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 500 × 500 × 600 mm |
| Weight | 50 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Model | TP6621 |
| Temperature Range | 0–460 °C |
| Temperature Resolution | 0.1 °C |
| Distillation Volume Range | 0–100 mL |
| Volume Measurement Accuracy | ±0.1 mL |
| Cold Bath Temperature Range | 0–80 °C |
| Recovery Chamber Temperature Range | 0–60 °C |
| Ambient Operating Temperature | 10–35 °C |
| Storage Temperature | −10–55 °C |
| Relative Humidity | 10–70% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤4 kW |
| Dimensions | 500 × 500 × 600 mm |
| Weight | 50 kg |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP671 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.2 °C (25–50 °C), ±0.3 °C (50–100 °C) |
| Oscillation Frequency | 275 ± 3 cycles/min |
| Oscillation Amplitude | 35 mm |
| Sample Capacity | 8 × 100 mL syringes or 4 × 250 mL Erlenmeyer flasks |
| Timing Resolution | ±10 s (0–99 min) |
| Power Consumption | ≤800 W |
| Dimensions | 500 × 350 × 370 mm |
| Weight | 30.5 kg |
| Noise Level | <40 dB(A) |
| Display | LCD with tactile-free membrane keypad |
| Operating Environment | 5–40 °C, RH ≤85% |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP671 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.2 °C (ambient–50 °C), ±0.3 °C (50–100 °C) |
| Oscillation Frequency | 275 ± 3 cycles/min |
| Oscillation Amplitude | 35 mm |
| Sample Capacity | 8 × 100 mL syringes or 4 × 250 mL Erlenmeyer flasks |
| Timing Resolution | ±10 s (0–99 min) |
| Power Consumption | ≤800 W |
| Dimensions | 500 × 350 × 370 mm |
| Weight | 30.5 kg |
| Noise Level | <40 dB(A) |
| Operating Environment | 5–40 °C, RH ≤85% |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower (Beijing Shidai Xinwei Measurement & Control Equipment Co., Ltd.) |
| Model | TP672 |
| Compliance | GB/T 507, DL 429.9 |
| Voltage Ramp Rates | 2.0 ± 0.2 kV/s and 3.0 ± 0.2 kV/s |
| Accuracy | ±2% of full scale |
| Measurement Range | 0–80 kV |
| Resolution | 0.01 kV |
| Test Repetition | 1–9 cycles (default 6) |
| Stirring Time | Magnetic stirring |
| Standby Time | 15 min (adjustable 0–59 min) |
| Inter-test Interval | 3–5 min (adjustable 0–9 min) |
| Display | LCD |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 610 × 410 × 425 mm |
| Weight | 45 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP672 |
| Pricing | Upon Request |
| Dielectric Strength Measurement Range | 0–80 kV |
| Accuracy | ±2% |
| Rise Rate Options | 2.0±0.2 kV/s and 3.0±0.2 kV/s |
| Resolution | 0.01 kV |
| Test Repetition | 1–9 cycles (default 6) |
| Stirring Method | Magnetic stirring |
| Standby Time | 0–59 min (default 15 min) |
| Inter-test Interval | 0–9 min (default 3–5 min) |
| Display | LCD |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 610 × 410 × 425 mm |
| Weight | 45 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP672 |
| Quotation | Upon Request |
| Standard Compliance | GB/T 507, IEC 60156 |
| Measurement Principle | AC Dielectric Breakdown Voltage (BDV) under Controlled Ramp Voltage |
| Voltage Range | 0–80 kV |
| Resolution | 0.1 kV |
| Accuracy | ±2% of full scale |
| Rising Rate Options | 2.0 kV/s and 3.0 kV/s (adjustable within 2.0–3.0 kV/s) |
| Test Repetition | 1–9 cycles (default: 6) |
| Oil Cup Configuration | Triple-cup station with magnetic stirring |
| Stirring Duration | Adjustable (0–59 min) |
| Resting Time | Default 15 min (0–59 min adjustable) |
| Inter-test Interval | Adjustable (0–9 min, default 3–5 min) |
| Display | LCD panel with real-time voltage and status feedback |
| Protection | Overvoltage, overcurrent, auto-zero reset, and fail-safe arc suppression |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 610 × 410 × 425 mm |
| Weight | 45 kg |
| Transformer Type | Dry-type, compact modular design |
| Data Handling | Internal non-volatile memory for test records |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP672 |
| Quotation | Upon Request |
| Dielectric Strength Measurement Range | 0–80 kV |
| Voltage Ramp Rates | 2.0 ± 0.2 kV/s and 3.0 ± 0.2 kV/s |
| Accuracy | ±2% |
| Resolution | 0.01 kV |
| Test Repetition | 1–9 cycles (default 6) |
| Stirring Method | Magnetic stirring |
| Standby Time | 0–59 min (default 15 min) |
| Inter-test Interval | 0–9 min (default 3–5 min) |
| Display | LCD |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 610 × 410 × 425 mm |
| Weight | 45 kg |