| Brand | Instron |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | E10000 Axial-Torsional |
| Test Force Capacity | ±10 kN (axial), ±100 N·m (torsional) |
| Frequency Range | up to 100 Hz |
| Frame Weight | 994 kg |
| Power Supply | Single-phase AC |
| Cooling | Temperature-controlled air cooling |
| Frame Footprint | < 0.8 m² (8.6 ft²) |
| Stroke | ±60 mm |
| Torsion Range | ±135° / ±16 revolutions |
| Control System | Instron Dynacell™ dynamic load cell + digital controller with stiffness-based tuning |
| Software Platform | Console™, compatible with WaveMatrix 3™ (dynamic), Bluehill® Universal™ (static), and application-specific modules |
| Brand | Instron |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | E3000 |
| Frequency Range | 100 Hz |
| Frame Weight | 240 kg |
| Power Supply | Single-phase AC |
| Maximum Dynamic Axial Load | ±3000 N |
| Maximum Static Axial Load | ±2100 N |
| Test Stroke | 60 mm |
| Footprint | < 0.3 m² (3.2 ft²) |
| Cooling Method | Temperature-Controlled Air Cooling |
| Frame Architecture | High-Stiffness Dual-Column with Top-Mounted Actuator |
| Actuator Technology | Direct-Drive Linear Motor |
| Load Sensing | Dynacell™ Dynamic Load Cell |
| Position Feedback | Optical Encoder with Dedicated Position Channel |
| Control System | Instron Digital Controller with Stiffness-Based Tuning Algorithm |
| Software Platform | Console™ (system control), Bluehill® Universal (static testing), WaveMatrix 3 (dynamic/fatigue testing) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Instron |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Instron (UK) Ltd. |
| Type | Imported |
| Model | E3000 Biaxial Tension-Torsion |
| Frequency Range | 0–100 Hz |
| Frame Weight | 250 kg |
| Power Supply | Single-phase AC |
| Max Dynamic Axial Load | ±3000 N |
| Max Dynamic Torque | ±25 N·m |
| Stroke | ±60 mm |
| Torsional Range | ±135° / ±16 revolutions |
| Cooling | Temperature-controlled air cooling |
| Frame Stiffness | High-rigidity dual-column architecture with optical encoder-based position feedback |
| Control System | Digital controller with stiffness-based tuning algorithm for axial and torsional channels |
| Software Compatibility | WaveMatrix 2 (dynamic), Bluehill Universal (quasi-static), ASTM/ISO-compliant test method libraries |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | HDX |
| Instrument Type | Hydraulic Universal Testing Machine |
| Frame Load Capacity | 1000 kN |
| Test Speed (Full Load) | 100 mm/min (39 in/min) |
| Position Resolution (Standard) | 6.35 µm (0.00025 in) |
| Position Accuracy (Standard) | ±1% or 0.254 mm (0.01 in), whichever is greater |
| Position Resolution (High-Resolution Option) | 1.27 µm (0.00004 in) |
| Position Accuracy (High-Resolution Option) | ±0.5% or 0.13 mm (0.005 in), whichever is greater |
| Actuator Stroke | 254 mm (10 in) |
| Crosshead Adjustment Speed | 300 mm/min (12 in/min) |
| Tensile Test Space (Open Crosshead) | 0–760 mm (0–30 in) |
| Tensile Test Space (Closed Crosshead) | 0–1270 mm (0–50 in) |
| Specimen Gauge Length Range (Open Crosshead) | 400–1050 mm (16–41.5 in) |
| Specimen Gauge Length Range (Closed Crosshead) | 400–1665 mm (16–65.5 in) |
| Compression Test Space | 0–1000 mm (0–39.5 in) |
| Horizontal Clearance | 741 mm (29.2 in) |
| Floor Footprint | 1228 mm W × 832 mm D (48.4 in × 32.8 in) |
| Maximum Operating Height | 3366 mm (132.5 in) |
| Brand | INSTRON |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | KPX |
| Instrument Type | Hydraulic Universal Testing Machine |
| Load Capacity Range | 600–3,500 kN (135,000–800,000 lbf) |
| Test Space Configuration | Single-Space Frame (Tension & Compression Capable) |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | KPX |
| Instrument Type | Hydraulic Universal Testing Machine |
| Load Capacity Options | 600 kN, 1500 kN, 2000 kN, 3500 kN |
| Actuator Speed | High-speed hydraulic actuation |
| Test Space | Single-column, single-test-space architecture |
| Stroke Length | Extended travel for large-scale specimens |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LX |
| Instrument Type | Hydraulic Universal Testing Machine |
| Load Capacity Options | 150 kN, 300 kN, 600 kN |
| Force Measurement Accuracy | ±0.5% of reading (down to 1/250 of load cell full scale) |
| Strain Measurement Accuracy | ±0.5% of extensometer reading (down to 1/50 of extensometer full scale) |
| Data Acquisition Rate | Up to 500 Hz synchronized across all channels |
| Power Supply | Single-phase 220 V ±10%, 50 Hz, 2750 VA |
| Dimensions (H×W×D) | 2356–2502 mm × 675–915 mm × 675–877 mm |
| Weight | 590–1474 kg |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MDX |
| Instrument Type | Hydraulic Universal Testing Machine |
| Control System | Instron 59-Series Controller (1000 Hz Closed-Loop Rate) |
| Drive System | High-Response Servo Valve (200 Hz Bandwidth) |
| Hydraulic Power Unit | Instron V11b Variable-Pressure Pump |
| Clamp Integration | Integrated Hydraulic Wedge Grips in Crosshead |
| Software | Instron Partner Software |
| Load Capacity Options | 600 kN, 1000 kN, 1500 kN |
| Brand | Instron |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | Instron Strain Gauge Measurement System |
| Instrument Type | Electromechanical Universal Testing Machine |
| System Composition | 4-Channel Dynamic Resistive Strain Amplifier |
| Required Hardware | Instron testing system equipped with 1–2 dedicated strain input channels |
| Brand | INSTRON |
|---|---|
| Origin | USA |
| Manufacturer | INSTRON Corporation |
| Product Type | Imported |
| Model | SVE3 |
| Pricing | Upon Request |
| Brand | Instron |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TMF |
| Instrument Type | Thermal-Mechanical Fatigue Tester |
| Compliance Standards | ASTM E2368, ISO 12111 |
| Brand | Instron |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | VHS |
| Test Machine Type | Electro-Hydraulic Servo Fatigue Testing System |
| Maximum Test Force | ±35 kN, ±40 kN, ±65 kN, ±160 kN |
| Velocity Range | Up to 20 m/s (VHS 65/80 optional at 25 m/s) |
| Machine Weight | 2500 kg, 2900 kg, or 5300 kg depending on configuration |
| Brand | Instytut Fotonowy |
|---|---|
| Origin | Poland |
| Model | Electrochemical Kelvin Probe |
| Weight | 15 kg |
| Dimensions | 40 × 40 × 45 cm |
| Power Supply | 230 V, 50 Hz or 115 V, 60 Hz |
| PC Interface | USB 2.0 |
| Measurement Principle | Dual-channel lock-in amplifier-based vibrating capacitor method |
| Contact Potential Difference (CPD) Range | −5 to +5 V |
| CPD Resolution | 0.15 mV |
| Current Ranges | 300 nA / 30 nA / 3 nA / 300 pA |
| Probe Tip | Au mesh, 2.5 mm diameter |
| Vertical Positioning Resolution | 20 µm |
| Typical CPD Measurement Gap | 0.2–1 mm |
| XY Motorized Stage | 50 × 50 mm travel range |
| Faraday Cage | Standard airtight version with inert gas flow system |
| Electrochemical Cell | PTFE body, Kapton-insulated sample substrate, Ag/AgCl reference electrode option |
| Optical Access | Fused silica window, UV-enhanced mirror, liquid light guide for bottom illumination |
| Environmental Sensors | Integrated temperature and humidity monitoring |
| Laser Guidance System | Visible alignment laser with automatic gap-sensing barrier |
| Brand | INTEC |
|---|---|
| Origin | Japan |
| Model | KE-6 / KE-6S / KE-6SS |
| Detection Method | Transmission optical imaging of aligned filaments |
| Max Single-Measurement Capacity | 100 (KE-6), 200 (KE-6S & KE-6SS) filaments |
| Segment Measurement Range | 1–6 segments |
| Total Measurable Filaments per Sample | up to 599 (KE-6), 999 (KE-6S & KE-6SS) |
| Filament Linear Density Range | 0.6–33 dtex (KE-6/KE-6S), 2–33 dtex (KE-6SS, TiO₂ ≤2.0% w/w) |
| Filament Count Adjustment Limit | Total dtex × filament count ≤ 50,000 (KE-6), ≤ 250,000 (KE-6S/KE-6SS) |
| Alignment Aid | Vibration bar for uniform filament arrangement |
| Image Acquisition | Real-time CCD-based transmission imaging with auto-focus assist |
| Illumination Monitoring | Integrated lux meter for ambient and backlight intensity control |
| Operation Mode | Manual (button) or foot-switch triggered scanning |
| Power Supply | 100 V / 220 V, 50/60 Hz, single-phase |
| [Brand | Interface |
|---|---|
| Origin | Beijing, China |
| Model | JK99CN |
| Measurement Range | 0–999.99 mN/m |
| Resolution | <0.05 mN/m |
| Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Time | 1–5 s (plate), 20–150 s (ring) |
| Power Supply | AC 220 V, 50 Hz, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999] |
| Brand | Interface |
|---|---|
| Origin | Beijing, China |
| Model | JK99F |
| Measurement Range | 0–999.99 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.01 mN/m |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sample Elevation Range | 0–50 mm |
| Elevation Precision | 0.1 µm |
| Mass Measurement Range | 0–150 g (0.1 mg resolution) |
| Sampling Time | Ring method: 20–150 s |
| Plate method | 1–5 s |
| Power Supply | AC 220 ±5 V, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | Interface |
|---|---|
| Origin | Beijing, China |
| Model | SCI2000A |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Sample Stage Dimensions | 120 × 100 mm |
| Imaging Resolution (min) | 1280 × 1024 pixels |
| Surface/Interfacial Tension Range | 5.0–2000 mN/m |
| Surface Tension Resolution | 0.001 mN/m |
| Imaging Speed (standard) | 25 fps |
| Optical Magnification | 0.7–5.0× continuous zoom |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 300 × 500 × 420 mm |
| Weight | 15 kg |
| Brand | Interface |
|---|---|
| Origin | Beijing, China |
| Model | SCI2000B |
| Instrument Type | Benchtop Laboratory Video Optical Contact Angle Meter |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Roll-Off Angle Measurement Range | 0–360° |
| Surface/Interfacial Tension Range | 5.0–2000 mN/m |
| Surface Tension Resolution | 0.001 mN/m |
| Sample Stage Dimensions | 120 × 100 mm |
| Minimum Image Resolution | 1280 × 1024 pixels |
| Optical Magnification | 0.7–5.0× continuous zoom (industrial-grade 60× effective magnification) |
| Frame Rate (standard) | 25 fps (upgradable to 2000 fps) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W × D × H) | 300 × 500 × 420 mm |
| Weight | 15 kg |
| Brand | Interface |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 120 × 100 mm |
| Minimum Image Resolution | 1280 × 1024 |
| Surface/Interfacial Tension Range | 5.0–2000 mN/m |
| Brand | Interface |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SCI2000D |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Fixed Sample Stage Dimensions | 120 × 100 mm |
| Minimum Image Resolution | 1280 × 1024 pixels |
| Surface/Interfacial Tension Measurement Range | 5.0–2000 mN/m |
| Brand | Interface |
|---|---|
| Origin | Beijing, China |
| Model | SCI2000G |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 120 × 100 mm |
| Minimum Image Resolution | 1280 × 1024 pixels |
| Surface/Interfacial Tension Range | 5.0–2000 mN/m |
| Imaging Speed (Standard) | 25 fps |
| Measurement Methods | Sessile Drop, Pendant Drop, Captive Bubble, Tilting Plate |
| Software Compliance | ASTM D724, ASTM D5946, ISO 15989 |
| Brand | Interface |
|---|---|
| Origin | Beijing, China |
| Model | SCI2000H |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Sample Stage Dimensions | 120 × 100 mm |
| Stage Temperature Range | Ambient to 400 °C |
| Imaging Resolution (Min) | 1280 × 1024 pixels |
| Frame Rate (Standard) | 25 fps |
| Surface/Interfacial Tension Range | 5.0–2000 mN/m |
| Surface Tension Resolution | 0.001 mN/m |
| Measurement Methods | Sessile Drop, Pendant Drop, Captive Bubble, Tilting Plate, and Immersion Plate |
| Software Compliance | Supports ASTM D724, ASTM D5946, ISO 15989 |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545-M |
| Temperature Range | –100 °C to +300 °C |
| Ramp Rate | Up to 18 °C/s |
| Temperature Accuracy | ±1.0 °C |
| Operating Modes | Air Mode & DUT Mode (Device-Under-Test Mode) |
| Thermocouple Interface | Type T |
| Compliance | Designed for semiconductor ATE integration (e.g., Advantest memory testers) |
| Application Focus | Non-volatile memory thermal qualification (NOR/NAND Flash, eMMC) |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545-M-k |
| High Temp Range | 0 to 225 °C |
| Low Temp Range | −75 to 0 °C |
| Thermal Shock Range | −75 to +225 °C (50 Hz) |
| Temperature Stability | ±1 °C |
| Ramp Rate (Heating) | ≤10 s from −55 to +125 °C |
| Ramp Rate (Cooling) | ≤10 s from +125 to −55 °C |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-710E |
| High-Temperature Range | 0 to 225 °C |
| Low-Temperature Range | −80 to 0 °C |
| Thermal Shock Range | −80 to +225 °C |
| Temperature Stability | ±1 °C |
| Heating Rate | ~10 s from −55 °C to +125 °C |
| Cooling Rate | ~10 s from +125 °C to −55 °C |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | inTEST ATS-710E |
| Quotation | Upon Request |
| High-Temperature Range (°C) | +225 |
| Low-Temperature Range (°C) | −75 |
| Thermal Shock Range (°C) | −75 to +225 (50 Hz) |
| Temperature Stability (°C) | ±0.1 °C |
| Heating Rate (°C/min) | −55 to +125 °C in ~10 s |
| Cooling Rate (°C/min) | +125 to −55 °C in ~10 s |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Display Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interfaces | Ethernet, IEEE-488 (GPIB), RS-232 |
| Control Interface | Touchscreen HMI with embedded real-time OS (Windows-free architecture) |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-770E |
| High Temperature Range | +225°C |
| Low Temperature Range | -95°C |
| Thermal Shock Range | -95°C to +225°C |
| Temperature Stability | ±0.01°C |
| Ramp Rate (Heating) | -55°C to +125°C in <10 s |
| Ramp Rate (Cooling) | +125°C to -55°C in <10 s |
| Airflow Capacity | 4–12 scfm (1.8–5.6 L/s) |
| Temperature Display Resolution | ±1°C |
| Temperature Display Accuracy | ±1°C (NIST-traceable calibration) |
| Control Interface | Touchscreen HMI |
| Communication Protocols | Ethernet, IEEE-488 (GPIB), RS-232 |
| Operating Modes | Air Mode, DUT Mode (T-type or K-type thermocouple support) |
| Compliance | CE-marked, CFC-free, GLP/GMP-ready architecture |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor (Imported) |
| Model | BT28 |
| High Temperature Range | +125°C |
| Low Temperature Range | −10°C |
| Thermal Shock Range | −10°C to +125°C |
| Temperature Stability | ±0.1°C |
| Heating Rate | −10°C to +125°C in ≤10 s |
| Cooling Rate | +125°C to −10°C in ≤10 s |
| Airflow Output | 14 scfm |
| Temperature Accuracy | ±1.0°C (NIST-traceable calibration) |
| Temperature Resolution | 0.1°C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interfaces | Ethernet, IEEE-488 (GPIB), RS-232, USB Serial |
| Overtemperature Protection | Factory-set at +225°C (user-configurable limits) |
| Dimensions (W×D×H) | 35.4 × 59.5 × 42.5 cm (base) |
| Weight | 38.3 kg (system), 31.8 kg (without arm/head) |
| Noise Level | <60 dBA (operational), <50 dBA (standby) |
| Refrigerant | Non-ozone-depleting, non-toxic, non-flammable blend |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ECO-710E |
| High Temp Range | +225 °C |
| Low Temp Range | −80 °C |
| Thermal Shock Range | −80 to +225 °C |
| Temperature Stability | ±0.1 °C |
| Ramp Rate (−55 to +125 °C) | ~10 s |
| Ramp Rate (+125 to −55 °C) | ~10 s |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-505 |
| Temperature Range | –20 °C to +225 °C |
| Ramp Rate | Up to 18 °C/s (heating/cooling) |
| Temperature Accuracy | ±1 °C |
| Control Interface | Rotary Knob Panel |
| Cooling Method | Compressed Dry Air + Integrated Refrigeration Unit |
| Heating Method | Resistive Heated Air Stream |
| Safety Protection | Adjustable Over-Temperature Cutoff (factory default: +230 °C) |
| Form Factor | Benchtop |