| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Sample Throughput | 4 measurements/h (isoperibol), 6 measurements/h (dynamic) |
| Heat Capacity Calibration Range | 40,000 J |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Cooling Medium | Tap water (12–27 °C), max. pressure 1.5 bar, flow rate 60–70 L/h (KV600 chiller compatible) |
| Max. Oxygen Pressure | 40 bar |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Ambient Operating Conditions | 20–25 °C, ≤80 % RH |
| Ingress Protection | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz, 2000 W |
| Compliance Standards | DIN 51900, DIN EN ISO 1716, DIN EN ISO 9831, DIN EN 15170, DIN CEN TS 14918, ASTM D240, ASTM D4809, ASTM D1989, ASTM D5865, ASTM E711, ISO 1928, GB/T 213 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/12 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| External Water Jacket Volume | ~8 L |
| Internal Water Jacket Volume | ~2.5 L |
| Max. Oxygen Pressure | 40 bar |
| Cooling Medium Flow Rate | 60–70 L/h (at 18 °C) |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Rated Input Power | 2000 W |
| Protection Rating | IP20 |
| Ambient Operating Conditions | 20–25 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Country of Origin | Imported |
| Model | C 7000 Basic Equipment Set 1 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol Dry-Mode Combustion Calorimetry (ISO 1928) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.2 % RSD (per 1 g benzoic acid, NIST SRM 39i) |
| Single-Sample Test Duration | ~3–5 min |
| Heat Capacity | 30,000 J/K |
| Cooling Medium | Tap water |
| Minimum Cooling Flow Rate | 120–180 L/h |
| Max Operating Oxygen Pressure | 40 bar |
| Max Cooling Medium Pressure | 9 bar |
| Ambient Temperature Range | 18–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Power Supply | 220–240 V, 50/60 Hz |
| Input Power | 260 W |
| Dimensions (W×D×H) | 310 × 395 × 490 mm |
| Weight | 50.162 kg |
| Interfaces | RS232 (balance, printer, PC), Centronics printer port |
| Oxygen Bomb Recognition | Automatic encoded detection |
| Compatible Crucibles | C14 combustion crucibles (retrofittable) |
| Software | C5040 CalWin v3.x (menu-driven, GLP-compliant data handling) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C200 |
| Measurement Modes | Isothermal, Fast Dynamic, Manual, Time-Controlled |
| Standards Compliance | DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711 |
| Max Energy Range | 40,000 J |
| Operating Voltage | 24 V DC (instrument), 100–240 V AC / 50–60 Hz (external power supply) |
| Power Consumption | ≤100 W (calorimeter), ≤120 W (system) |
| Dimensions (W×D×H) | 400 × 400 × 400 mm |
| Weight | 21 kg |
| Protection Class | IP21, Class III |
| Ambient Conditions | 20–25 °C, ≤80 % RH, up to 2,000 m altitude |
| Interfaces | 1× RS-232, 1× Centronics parallel port |
| Software | Calwin C 5040 (real-time monitoring, data export to Excel/Word) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C 3000 eco |
| Calorimetric Principle | Isoperibol Oxygen Bomb Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Measurement Time | 15 min |
| Heat Capacity Calibration Range | Up to 40,000 J |
| Outer Water Jacket Volume | Approx. 3.5 L |
| Inner Water Bucket Volume | Approx. 2.2 L |
| Operating Ambient Temperature | 20–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Rating | IP20 (DIN EN 60529) |
| Power Supply | 220–240 V, 50/60 Hz, 1700 W |
| Dimensions (W × D × H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Cooling Medium | Tap water or external chiller (e.g., RC 2 basic) |
| Oxygen Pressure | Up to 40 bar |
| Compliance Standards | ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, GB/T 213 |
| Data Interfaces | Ethernet, RS232, USB, SD card slot |
| Optional Accessories | C6010 & C6012 decomposition bombs, RC 2 basic recirculating chiller |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Modes | Adiabatic, Isoperibol (Isothermal), Dynamic |
| Temperature Range | 22–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (Adiabatic & Isothermal, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity Calibration Range | 40,000 J |
| Cooling Circulator | RC 2 Basic |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Max Oxygen Pressure | 40 bar |
| Cooling Medium | Tap water |
| Min Flow Rate | 60 L/h |
| Max Flow Rate | 70 L/h |
| Ambient Operating Temp | 20–25 °C |
| Relative Humidity Limit | ≤80% RH |
| Protection Class | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 2000 W |
| Dimensions (W×D×H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | E2K |
| Operating Temperature Range | 0–60 °C |
| Temperature Repeatability | ≤0.1% RSD |
| Temperature Resolution | 1 µK |
| Gross Calorific Value Resolution | 0.001 MJ/kg |
| Calibration | 10 stored calibration curves per smart bomb vessel, automatic standard deviation correction, integrated calibration sensors per vessel |
| Sample Throughput | Up to 10 samples/hour (standard configuration) |
| Measurement Time | 1.5–3 min per test |
| Dimensions (W×D×H) | 280×400×290 mm |
| Weight | 9 kg |
| Data Storage Capacity | >1000 test records with full metadata (operator ID, ambient conditions, calibration traceability) |
| Connectivity | Ethernet-enabled for multi-unit network (up to 7 units) |
| Ignition Control | Adjustable ignition energy, programmable high/low sample mass limits, customizable test cycle parameters |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | ROTATEMP Package |
| Instrument Type | Rotational Viscometer Accessory System |
| Mounting Style | Benchtop Fixed Installation |
| Operating Environment | Ambient Temperature |
| Viscosity Range (with ROTAVISC) | 1–320,000,000 mPa·s |
| Max. Operating Temperature | 300 °C |
| Minimum Sample Volume | 7 mL |
| Maximum Sample Volume | 13 mL |
| Sample Vessel | Dedicated cylindrical chamber |
| Dimensions (W×D×H) | 265 × 220 × 270 mm |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Ingress Protection | IP40 per DIN EN 60529 |
| Interface | RS232 |
| Voltage | 220–230 V AC |
| Frequency | 50/60 Hz |
| Rated Power Input | 300 W |
| Standby Power Consumption | 1.6 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Model | ROTAVISC hi-vi I Complete |
| Viscosity Range | 200 – 80,000,000 mPa·s |
| Temperature Range | −100 °C to 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Measurement Range | 1.4374 mN·m |
| Full-Scale Accuracy | ±1 % FSR |
| Repeatability | ±0.2 % FSR |
| Display | 4.3″ TFT touchscreen |
| Interfaces | RS232, USB |
| Power Supply | 100–240 V AC, 50/60 Hz |
| IP Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Compliance | DIN EN 60529, CE, RoHS |
| Brand | IKA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-assembled) |
| Model | ROTAVISC hi-vi I COMPLETE |
| Instrument Type | Portable Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 200 – 80,000,000 mPa·s |
| Temperature Accuracy | ±1% Full Scale Reading (FSR) |
| Speed Range | 0.01 – 200 rpm (infinitely variable) |
| Display | 4.3-inch TFT touchscreen with real-time viscosity curve plotting |
| Standard Accessories | SP7–SP12 spindle set, spindle guard stand, integrated Pt100 temperature probe |
| Measurement Accuracy | ±1% FSR |
| Repeatability | ±0.2% FSR |
| Compliance | ASTM D2196, ISO 2555, USP <911>, GLP-compliant data logging capability |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Benchtop Rotational Viscometer |
| Viscosity Range | 200 – 80,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | 4.3″ TFT touchscreen |
| Connectivity | RS-232, USB |
| Protection Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ROTAVISC hi-vi II Complete |
| Instrument Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 800 – 320,000,000 mPa·s |
| Temperature Range | −100 – 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Range | Up to 5.7496 mN·m |
| Full-Scale Accuracy | ±1 % FSR |
| Repeatability | ±0.2 % FSR |
| Display | 4.3″ TFT touchscreen |
| Interfaces | RS232, USB |
| Protection Rating | IP40 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Benchtop Rotational Viscometer |
| Viscosity Range | 800 – 320,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Range | up to 5.7496 mN·m |
| Display | 4.3″ TFT touchscreen |
| Interface | RS-232, USB |
| Compliance | DIN EN 60529 (IP40), CE, RoHS |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Weight | 7.1 kg |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01–200 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | TFT touchscreen |
| Interfaces | RS-232, USB |
| Protection Class | IP40 |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Operating Ambient | 0–40 °C, ≤80% RH |
| Compliance | DIN EN 60529, CE, RoHS |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | ROTAVISC LO-VI COMPLETE |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Range | 5–40 °C |
| Temperature Resolution | ±1 °C |
| Temperature Accuracy | ±1 °C |
| Display | 4.3″ TFT touchscreen |
| Measurement Accuracy | ±1 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Speed Control | Continuously variable (RAMP gradient function supported) |
| Included Accessories | SP1–SP4 standard spindle set, ROTASTAND manual lift stand, PT100 temperature probe, guard rail, USB A-to-Micro-B cable (2 m) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 15–6,000,000 mPa·s |
| Temperature Range | −100 to 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01–200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | 4.3″ TFT Touchscreen |
| Interfaces | RS-232, USB |
| Protection Rating | IP40 |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ROTAVISC me-vi Complete |
| Instrument Type | Benchtop Fixed-Position Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Torque Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1 % |
| Viscosity Repeatability (FSR) | ±0.2 % |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Interface | RS232, USB |
| IP Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Measurement Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1% |
| Viscosity Repeatability (FSR) | ±0.2% |
| Display | 4.3″ TFT Touchscreen |
| Interface | RS-232, USB |
| IP Rating | IP40 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Range | ROTAVISC lo-vi / me-vi / hi-vi I / hi-vi II Complete |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Control Range | −100 °C to +300 °C |
| Temperature Resolution | 0.1 K |
| Accuracy | ±1 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Speed Control | Continuously Variable (0.01–1,000 rpm) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #519 and #529 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #266 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | #434 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #471 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #321 / #322 / #343 |
| Pricing | Available Upon Request |
| Standards | DIN 53211 (Type #321), EN ISO 2431 (Type #322), ASTM D4212 (Type #343) |
| Orifice Diameters | 2–8 mm (Type #321) |
| Viscosity Range | 5–5000 mm²/s (kinematic viscosity) |
| Flow Time Range | 20–200 s |
| Materials | Anodized Aluminum (Type #321 & #343), Alumina Ceramic (Type #322) |
| Capacity | 100 mL nominal |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #508MC |
| Instrument Type | Gravel Impact Testing System |
| Compressed Air Supply | 6–10 bar (min. 6 bar, max. 10 bar), 13 mm ID hose |
| Operating Pressure Range | 0–3 bar (calibrated scale) |
| Gravel Feed Duration | 5–30 s (adjustable) |
| Power Supply | 230 V / 50 Hz (optional voltages available) |
| Gravel Specification | 4–5 mm sharp-edged granite particles (GHDiamant 06302) |
| Dimensions (L×D×H) | 175 × 50 × 122 cm |
| Net Weight | ~100 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | UNIMAT 050 / UNIMAT 052 |
| Quotation | Upon Request |
| Max Force Capacity | 2 kN (UNIMAT 050), 5 kN (UNIMAT 052) |
| Force Sensor Options | 10, 20, 50, 100, 200, 500, 1,000, 2,000, and 5,000 N |
| Position Resolution | 0.01 mm |
| Crosshead Speed Range | 0.2–1,000 mm/min (±0.5% accuracy at 2 mm/min) |
| Internal Width | 50 mm (UNIMAT 050), 300 mm (UNIMAT 052) |
| Max Crosshead Travel | 720 mm (UNIMAT 050), 860 mm (UNIMAT 052) |
| Power Supply | 230 V, 50/60 Hz |
| Dimensions (L×W×H) | 1020×310×310 mm (050M), 1020×310×390 mm (050S/SV), 1145×495×350 mm (052S/SV) |
| Weight | Approx. 20 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #475 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Type | Xenon arc exposure chamber |
| Model | #522 |
| Lamp power options | 1.5 kW / 2.5 kW |
| Illuminated area (W×D) | 280 × 220 mm / 420 × 200 mm |
| Chamber dimensions (W×D×H) | 750 × 390 × 400 mm / 890 × 390 × 400 mm |
| Weight | 29 kg / 31 kg |
| Sample capacity (15 × 30 mm) | >120 pcs / >180 pcs |
| Irradiance range | 0.25–1.0 kW/m² (290–800 nm) |
| Black panel temperature control | Yes |
| Chamber temperature & humidity display | Yes |
| Timer range | 0–9999 h |
| Timer preset | 0–999 h |
| Control interface | 4-line LCD display |
| Programmable test sequences | Up to 15 |
| Communication | RS232-C |
| Software | XEN 32 “Report” / “Rep+Cal” |
| Standard filter | 280 nm cutoff |
| Optional filters | 310 nm cutoff, IR rejection filter |
| Cooling | Water-cooled sample stage, air-cooling system |
| Humidity control | Integrated programmable water injection system (optional thermostatic control: 30–50 °C) |
| Stirring accessory | Magnetic stirrer for liquid samples |
| Power supply | 230 VAC, 50/60 Hz |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #606 & #608 Series |
| Price | Upon Request |
| Chamber Volume | 400 L / 1000 L / 2000 L (customizable for #608) |
| Sample Capacity | ~100 / ~180 / ~400 specimens (shape-dependent) |
| Specimen Racks | 3 units (18 specimens per rack) |
| Chamber Load Capacity | 300 kg (reinforced versions available) |
| Temperature Range | Ambient to +50 °C |
| Power Supply | 230 V / 400 V, 50 Hz (custom voltage options available) |
| Power Consumption | ~2000 VA / ~3000 VA / ~4000 VA |
| Compressed Air Pressure | 4–10 bar |
| Compressed Air Consumption | 6 Nm³/h |
| Deionized Water Supply Pressure | 2–8 bar |
| Drain & Exhaust Connection | Standard BSP/NPT fittings |
| Chamber Geometry | Cylindrical (dual 400 L or dual 1000 L configurations) and Rectangular (400 L / 1000 L / 2000 L variants) |
| Control Cabinet Depth | 1000 mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #610 |
| Pricing | Available Upon Request |