Physical Property Testing Instruments
Filter
Showing 12061–12090 of 12100 results
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | ZKTKY-100KN |
| Maximum Load Capacity | 100 kN |
| Loading Method | Electromechanical (AC Servo Motor + Precision Ball Screw) |
| Control Modes | Constant Rate of Force, Constant Rate of Displacement, Constant Rate of Strain |
| Frame Configuration | Bottom-Acting, Rigid Steel Frame |
| Force Measurement Accuracy | ±1% FS (per GB/T 3074.1–2021 and ISO 6892-1) |
| Safety Protections | Overload Cut-off, Specimen Fracture Detection, Piston Stroke Limit Switch |
| Compliance Standards | GB/T 3074.1–2021, GB/T 2611–2013, JJG 139–2014 |
| Software Interface | PC-based Control & Data Acquisition System with Audit Trail Capability |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZKWP-A |
| Price | USD 2,150 (FOB Beijing) |
| Heating Method | Electric Resistance Heating |
| Cooling Method | Liquid Nitrogen Cryogenic Cooling |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Range | −30 °C to +200 °C |
| Electrode Material | Brass |
| Electrode Diameter | 25 mm |
| Test Frequency Range | 20 Hz to 2 MHz |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150, IEC 60250 |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | ZKYHL-660936 |
| Instrument Type | Multi-functional Powder Flowability Tester |
| Measurable Parameter | Flow Time (s) |
| Funnel Outlet Diameter | 3.95–4.0 mm |
| Funnel Upper Inner Diameter | 123 mm |
| Funnel Upper Outer Diameter | 138.5 mm |
| Total Funnel Height | 190.5 mm |
| Upper Cone Angle | 60° |
| Lower Discharge Cone Angle | 15° |
| Maximum Sample Cup Capacity | 40 mL |
| Minimum Sample Mass | 10 g |
| Compliance Standard | GB/T 6609.36–2009 |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZMM 5000 |
| Pricing | Available Upon Request |
| Brand | ZOLLO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MJX-2000S |
| Capacity | 2000 L |
| External Dimensions (W×D×H) | 2395 × 760 × 1880 mm |
| Temperature Control Range | 0–50 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Control Range | 30–95 %RH |
| Humidity Uniformity | ±2 %RH |
| Heating/Cooling System | Imported Compressor + PID-Controlled Heating |
| Humidification Method | Ultrasonic Humidifier |
| Inner Chamber Material | Stainless Steel (304) |
| Door Structure | Quadruple Door with Triple-Layer Hollow Insulated Glass |
| Safety Features | Over-Temperature Protection, Sensor Fault Detection |
| Control Interface | Microprocessor-Based Touch Panel with Dual Digital Displays (Temp & RH) |
| Optional Functions | 30-Stage Programmable Cycle, RS485/USB PC Connectivity for Data Logging and Remote Control |
| Brand | ZOLLO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MJX-350S |
| Capacity | 350 L |
| Temperature Range | 0–50 °C |
| Temp. Uniformity & Accuracy | ±0.8 °C |
| Humidity Range | 30–95 %RH |
| Humidity Accuracy | ±2 %RH |
| Humidification Method | Ultrasonic |
| Construction | Stainless Steel Interior, Triple-Layer Insulated Glass Door, Lockable Frame |
| Control System | Microprocessor-Based Touch Interface with Dual Digital Displays (Temp & RH) |
| Safety Features | Over-Temperature Protection, Sensor Fault Detection |
| Optional | 30-Stage Programmable Controller or PC-Linked Data Logging |
| Brand | ZOLLO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MJX150S |
| Price | USD 1,250 (FOB Shanghai) |
| Capacity | 150 L |
| External Dimensions (W×D×H) | 594 × 594 × 1250 mm |
| Temperature Control Range | 0–50 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Control Range | 50–95 %RH |
| Humidity Uniformity | ±5 %RH |
| Humidification Method | Ultrasonic |
| Display | Dual digital LED (temp & RH) |
| Control System | Microprocessor-based touch interface |
| Safety Features | Over-temperature protection, sensor fault detection |
| Optional | 30-step programmable controller or PC-based remote monitoring via RS485/USB |
| Brand | SINOTEST |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZQP Series |
| Pricing | Available Upon Request |
| Brand | ZRTB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Model | JCY-3 |
| Price | USD 1,500 (approx.) |
| Compliance | GB/T 8627–2007, ASTM D2843 |
| Dimensions (L×W×H) | 740 × 500 × 900 mm |
| Weight | ~50 kg |
| Power Supply | 220 V ±10%, 50 Hz, 100 W |
| Operating Temp. | 0–40 °C |
| Relative Humidity | ≤85% RH |
| Gas Source | 95% propane (user-supplied) |
| Burner Pressure (main) | 276 kPa (adjustable) |
| Burner Pressure (pilot) | 210 ±5 kPa |
| Flame Application Time | 4 min |
| Light Source | 15 W, 6 V incandescent lamp |
| Photodetector | Silicon photovoltaic cell |
| Optical Measurement Range | 0–100% transmittance |
| Accuracy | ±3% |
| Calibration | Triple NIST-traceable neutral density filters (±3% verification error) |
| Control Interface | 5″ TFT touchscreen (800×480), RS232, FPGA-driven real-time display |
| Automation | Auto-ignition, auto-timing, auto-exhaust control, staged linear photometric correction |
| Enclosure Requirement | Fume hood installation mandatory |
| Airflow Constraint | No forced convection during test |
| Brand | SINOTEST |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZTH Series |
| Pricing | Available Upon Request |
| Brand | ZVISCO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | IV6600 |
| Instrument Type | Capillary Viscometer |
| Viscosity Range | 0.3–5000 mm²/s |
| Temperature Control Range | 15–65 °C |
| Temperature Uniformity & Stability | ≤ ±0.01 °C |
| Timing Resolution | 0.0001 s |
| Measuring Time Range | 0.01–9999.99 s |
| Cleaning/Drying Fluid Consumption per Cycle | < 13 mL |
| Compatible Capillaries | Ubbelohde, Micro-Ubbelohde, Dilution-type Ubbelohde (compliant with ISO 3105, GB/T 1632–1993, ASTM D 446, DIN 51562) |
| Software Platform | Windows XP/7/8/10 |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 1.9 kW |
| Dimensions (L×W×H) | 1300 × 600 × 600 mm |
| Brand | SINOTEST |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZXB Series |
| Pricing | Available Upon Request |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JF99M |
| Measurement Method | Washburn Capillary Rise Method |
| Pressure Range | 0–330 mbar |
| Pressure Resolution | 0.16 mbar |
| Operating Temperature | Ambient |
| Quartz Tube Dimensions | OD 10 mm, ID 8 mm or 6 mm |
| Power Supply | 220 V AC, 20 W |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK15A |
| Price Range | USD 7,000 – 14,000 |
| Surface Tension Range | 0–999.99 mN/m |
| Resolution | <0.05 mN/m |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Time | 1–5 s (plate), 20–150 s (ring) |
| Interfacial Tension Capability | Yes |
| Mass Measurement Range | 0–120 g (0.1 mg resolution) |
| Power Supply | AC 220 V, 50 Hz, <150 W |
| Operating Humidity | 30–85% RH |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK2000DM |
| Measurement Range | 0–500 mN/m |
| Resolution | <0.05 mN/m |
| Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Cycle | 1–5 s (Plate), 20–150 s (Ring) |
| Temperature Control | Integrated恒温 Platform (Compatible with External Circulating Bath) |
| Sensor | Imported Japanese High-Precision Force Transducer |
| Compliance | SY/T 5370–1999 |
| Power | AC 220 V ± 22 V, 50 Hz, <150 W |
| Operating Humidity | 30–85% RH |
| Optional Modules | Magnetic Stirring, Dynamic Contact Angle, Fiber Wettability, Density & Powder Wettability Kits |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99BM |
| Measurement Range | 0–500 mN/m |
| Sensitivity | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Resolution | 0.01 mN/m |
| Methods | Du Noüy Ring & Wilhelmy Plate |
| Sample Volume (Ring) | 40–50 mL |
| Sample Volume (Plate) | 20–30 mL |
| Sampling Time (Ring) | 150–200 s |
| Sampling Time (Plate) | 1–5 s |
| Power Supply | AC 220 V ±5%, <150 W |
| Temperature Sensing Accuracy | ±0.1 °C |
| Relative Humidity Range | 30–85% RH |
| Interface | RS-232 Serial Port |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986 |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Model | JK99H4 |
| Surface Tension Range | 0–500 mN/m |
| Resolution | 0.05 mN/m |
| Temperature Control Range | Ambient to 400 °C |
| Temperature Accuracy | ±1 °C |
| Measurement Methods | Du Noüy Ring & Wilhelmy Plate |
| Sampling Interval | 150–300 s (dual-speed adjustment) |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Power Consumption | <150 W |
| Operating Humidity | 30–85% RH |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99M Series |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.001 mN/m |
| Primary Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Interval | 1–5 s (plate), 20–150 s (ring) |
| Vertical Travel | 0–50 mm (standard), up to 110 mm (optional) |
| Positioning Precision | 0.1 µm |
| Data Acquisition Rate | 0.1 Hz (0.02 Hz optional) |
| Mass Measurement Range | 0–210 g (0.1 mg standard, 0.01 mg optional) |
| Temperature Sensing Accuracy | ±0.01 °C |
| Power Supply | AC 220 V ±5%, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99M |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.001 mN/m |
| Method | Du Noüy Ring & Wilhelmy Plate |
| Sampling Interval | Ring: 20–150 s |
| Plate | 1–5 s |
| Force Sensor | METTLER high-precision electromagnetic balance (0.1 mg / 0.01 mg optional) |
| Vertical Stage Travel | 0–50 mm (up to 110 mm optional) |
| Stage Precision | 0.1 µm |
| Speed Control | 0.1–500 mm/min |
| Temperature Monitoring | ±0.01 °C (external probe or internal liquid sensor optional) |
| Data Acquisition Rate | 0.1 Hz (0.02 Hz optional) |
| Power Supply | AC 220 ±5 V, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99M |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.001 mN/m |
| Method | Du Noüy Ring & Wilhelmy Plate |
| Sampling Interval | Ring method 20–150 s |
| Vertical Travel | 0–50 mm (optional 0–110 mm) |
| Positioning Precision | 0.1 µm |
| Data Acquisition Rate | 0.1 Hz (optional 0.02 Hz) |
| Temperature Sensing Precision | ±0.01 °C |
| Mass Measurement Range | 0–210 g (optional 0.01 mg resolution) |
| Power Supply | AC 220 V ±5%, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JML04C1M |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Trough Material | PTFE (Full Fluoropolymer) |
| Trough Dimensions | 200 mm × 80 mm |
| Compression Ratio | up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Vertical Dipping Speed | 0.22–45 mm/min |
| Dipping Modes | Upward/Downward |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 150 W |
| Operating Temperature | Ambient (with optional external thermostatic bath) |
| Relative Humidity | 30–85% RH |
| Software Interface | Windows-based GUI with data export, curve fitting, and post-processing capability |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JML04C2M |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Trough Material | PTFE (Full Fluoropolymer) |
| Trough Dimensions | 300 mm × 100 mm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upward & Downward |
| Power Supply | AC 220 V ±10%, 50 Hz, 150 W Max |
| Operating Temperature | Ambient (with optional external thermostatic bath) |
| Relative Humidity | 30–85% RH |
| Compliance | ASTM D971, ISO 6295, ISO 1409, USP <721>, GLP-ready data logging |
| Brand | ZYKX |
|---|---|
| Model | JPM2012M |
| Origin | Beijing, China |
| Power Supply | 220 V AC, 300 W |
| Dimensions (W×D×H) | 690 × 310 × 480 mm |
| Gas Flow Range | 0–500 mL/min (±0.5% accuracy, max pressure 0.5 MPa) |
| Foam Height Measurement | 0–280 mm via high-resolution video imaging |
| Minimum Sample Volume | 20 mL |
| Conductivity Sensing | 5-channel electrodes, resolution 0.01 µS/cm |
| Imaging System | 1300K-pixel digital camera, 25 fps, 5 mm macro lens |
| Foam Generator Pore Size (standard) | 1.0–1.6 µm |
| Temperature Control (optional) | ambient to 90 °C via integrated heating rod |
| Data Acquisition & Control | PC-based system with pre-installed proprietary software for real-time parameter configuration, curve visualization, and Excel-exportable reports |
| Optional Add-ons | top-view industrial CCD observation module, mechanical stirring foam generation unit |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JQ03E PRO |
| Measurement Range | 0–999.999 mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | ±0.01 mN/m |
| Sensitivity | 0.001 mN/m |
| Platinum Plate Method Sampling Time | 1–5 s |
| Platinum Ring Method Sampling Time | 50–200 s |
| CCD Imaging System | USB3.0 monochrome CMOS camera (1.3 MP, 54 fps), 0.7–4.5× continuous zoom, adjustable LED cold light source |
| Temperature Sensing Accuracy | ±0.1 °C (external probe optional) |
| Mass Measurement Range | 0–210 g (0.1 mg standard, 0.01 mg optional) |
| Vertical Stage Travel | 0–25 mm (0.1 mm standard, 1 µm optional) |
| Data Acquisition Rate | 0.1 s (0.02 s optional) |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986, SY/T 5370–1999 |
| Brand | Zykx |
|---|---|
| Model | JS94HX |
| Origin | Beijing, China |
| Type | Microelectrophoresis Instrument |
| Price Range | USD 7,000–14,000 |
| Particle Size Range | 0.5–20 µm (aqueous dispersions) |
| Zeta Potential Range | ±3000 mV |
| Measurement Accuracy | ±5% |
| pH Operating Range | 1.6–13.0 (0.1 resolution) |
| Temperature Control | 5–35 °C (±0.1 °C) |
| Sample Volume per Test | 0.5 mL |
| Optical System | Semiconductor-based blue/green LED illumination (low-power, <100 µW), 1200× magnification |
| Electrophoretic Cell | Integrated Ag/Pt/Ti electrodes in 0.5 cm-thick borosilicate glass cuvette |
| Voltage Polarity Switching | Adjustable from 0.30 to 1.20 s |
| Data Acquisition Time | 3–10 s per measurement |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JS94K2M |
| Price Range | USD 7,000 – 14,000 |
| Zeta Potential Range | ±3000 mV |
| Measurement Accuracy | ±5% |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.1 pH unit |
| Zeta Resolution | 1 mV |
| Temperature Range | −5.0 to 105.0 °C |
| Temperature Accuracy | ±0.1 °C |
| Optional Thermostatic Stage | −10 to 95 °C |
| Sample Volume per Measurement | 0.5 mL |
| Optical System | Semiconductor-based near-field blue/green LED illumination (λ ≈ 450–520 nm), 1200× digital magnification |
| Voltage Polarity Switching Time | Adjustable from 0.30 to 1.20 s |
| Measurement Cycle Time | 3–10 s |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 150 W |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Model | JS94KM |
| Zeta Potential Range | ±3000 mV |
| Accuracy | ±5% |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.1 pH |
| Zeta Resolution | 1 mV |
| Temperature Range | −5.0 to 105.0 °C (±0.1 °C) |
| Optional Thermostatic Stage | −10 to 95 °C |
| Sample Volume per Measurement | 0.5 mL |
| Optical System | Semiconductor-based near-field blue/green LED illumination (λ ≈ 450–520 nm), 1200× digital magnification |
| Electrophoresis Cell | Integrated Ag/Pt/Ti electrodes in 0.5 cm-thick borosilicate glass cuvette |
| Voltage Polarity Switching Time | 0.30–1.20 s (adjustable) |
| Sampling Duration | 3–10 s |
| Power Supply | 220 V AC, 50 Hz, 150 W |
| Compliance | Designed for GLP-aligned operation |
| Brand | Zykx |
|---|---|
| Model | JS94TM |
| Origin | Beijing, China |
| Type | Electrophoretic Light Scattering (ELS) Zeta Potential Analyzer |
| Particle Size Range | 0.2–50 µm (aqueous dispersions) |
| Zeta Potential Range | ±3000 mV |
| Accuracy | ±5% |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.1 pH unit |
| Zeta Resolution | 1 mV |
| Temperature Range | −5.0 to 105.0 °C (±0.1 °C) |
| Optional Thermostatic Stage | −10 to 95 °C |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 150 W |
| Sample Volume per Measurement | 0.5 mL |
| Electrode Configuration | Integrated Ag/AgCl–Pt–Ti tri-metal electrode system in precision-machined 0.5 cm-thick optical glass electrophoresis cell |
| Optical System | Near-field semiconductor illumination (blue/green LEDs, <100 µW), 1200× digital magnification, real-time dual-direction grayscale image capture |
| Voltage Control | Adjustable DC bias with polarity reversal (0.30–1.20 s interval), anti-polarization design |
| Data Acquisition | Automated temperature-compensated ELS image sequence capture and centroid velocity calculation |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-1100 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° (circle fitting method) |
| Sample Stage Dimensions | 20 × 20 mm |
| Optical Magnification | 55–320 pixel/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m |
| Maximum Operating Temperature | 1100 °C (long-term), 1700 °C (short-term peak) |
| Vacuum Level | ≤5 × 10⁻⁵ Pa |
| Heating Rate | 3–5 °C/min |
| Temperature Control | 40-segment programmable PID with K/S/B-type thermocouples |
| Cooling System | Water-cooled, 1200 W capacity, 5–35 °C setpoint, 10–20 L/min flow rate |
| Imaging | Industrial color CCD (0.0005 lux sensitivity), 750 TV lines, 30 fps standard (upgradable to 60/100 fps), 300 mm working distance lens with 0.7–5× continuous zoom |
| Software Analysis Methods | Tangent, Circle Fit, Ellipse Fit, Height/Width, Sessile Drop, Automatic Image-Based Analysis |
| Data Output | EXCEL-compatible reports with embedded temperature metadata, curve-fitting results, left/right angle differentiation, and AVI video export |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-1400 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° (circle fitting method) |
| Sample Stage Dimensions | 20 × 20 mm |
| Optical Magnification | 55–320 pixels/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m |
| Maximum Operating Temperature | 1400 °C (long-term), 1300 °C under vacuum |
| Base Vacuum Level | ≤5 × 10⁻⁵ Pa |
| Heating Control | 40-segment programmable PID with S-type thermocouple |
| Cooling System | Water-cooled, 1200 W capacity, flow rate 10–20 L/min, pressure 1.0–1.3 bar |
| Imaging System | Industrial color CCD (0.0005 lux sensitivity, 750 TV lines), 300 mm working distance telecentric lens, 0.7–5× continuous zoom |
| Software Analysis Methods | Tangent, Circle Fit, Ellipse Fit, Height Method, Angle Method, Automatic Image Analysis |