| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model | DSC7000 |
| Heating Rate | 0.01–100 °C/min |
| Temperature Range | –150 to 725 °C |
| Baseline Stability | ±5 µW |
| Sensitivity | <0.1 µW |
| Maximum Sample Power Capacity | ±350 mW |
| Atmosphere Options | Ambient Air, Inert Gas (N₂, Ar) |
| Cooling Options | Integrated Peltier Cooling (–80 to 500 °C), Optional Automated Liquid Nitrogen Cooling (–150 to 725 °C) |
| Optional Modules | Mass Flow Controlled Gas Delivery System, Auto Sampler Unit, UV Irradiation Unit (with Intensity Meter & Wavelength-Selective Filters), Real-Time Sample Observation Unit |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Product Type | Imported Instrument |
| Model | STA300 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy | ±0.2 K |
| Temperature Precision | ±0.07 °C |
| Heating/Cooling Rate | 0.01–150 K/min |
| Maximum Sample Mass | 0.2 g |
| Brand | Hitachi |
|---|---|
| Origin | Imported |
| Manufacturer | Hitachi High-Tech Corporation |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 °C to 600 °C |
| Frequency Range | Sinusoidal mode: 0.01–200 Hz |
| Composite waveform mode | simultaneous 5 frequencies |
| Compliance | ASTM D4065, ISO 6721, ISO 11357-4, USP <1031>, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | Hitachi |
|---|---|
| Model | DSC600 / DSC200 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Sample Throughput | Multi-sample simultaneous measurement |
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Application Scope | Polymer, Pharmaceutical, Chemical, Petrochemical, Food, and Metallic Materials Characterization |
| RealView® Imaging System | Integrated 20-MP camera with 50× digital zoom and 1.2 µm pixel resolution |
| Polarized Light Capability | Optional polarized optical module for birefringence and crystalline orientation analysis |
| Data Export Formats | CSV, Excel (.xlsx), plain text |
| Barcode Integration | Supported for automated method and sample metadata ingestion |
| Software Compliance | Audit-trail enabled |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model Variants | STA7200, STA7200RV, STA7300 |
| Heating Rate | 0.01–150 °C/min |
| Temperature Range | Ambient to 1100 °C |
| Temperature Stability | ±0.1 °C over full range |
| Maximum Sample Capacity | ±400 mg |
| Atmosphere Options | Ambient air, inert gas (N₂, Ar), optional gas flow control via mass flow meter |
| Real-Time Sample Imaging | Up to 1000 °C with RV-3TG optical module |
| Autosampler Compatibility | AS-3T (50-position) |
| Control Architecture | Digital horizontal differential balance with active drift compensation |
| Cooling Method | FRONT-STREAM low-thermal-mass design |
| Brand | Hitachi |
|---|---|
| Model | TMA7100 / TMA7300 |
| Temperature Range | TMA7100: −170 °C to 600 °C |
| TMA7300 | Ambient to 1500 °C |
| Displacement Range | ±5 mm |
| RMS Noise / Sensitivity | 0.005 μm / 0.01 μm |
| Load Range (Resolution) | ±5.8 N (9.8 μN) |
| Heating Rate | 0.01–100 °C/min |
| Sample Max Dimensions | Ø10 mm × 25 mm (TMA7100/TMA7300) |
| Probe Mounting | Cantilever-type |
| Atmosphere Control | Ambient air, inert gas, vacuum (~1.3 Pa) |
| Load Control Modes | Fixed load, constant-rate loading (9.8×10⁻²–9.8×10⁶ mN/min), frequency sweep (0.001–1 Hz), multi-step program (up to 40 steps) |
| Displacement Control Modes | Fixed displacement (±5000 μm), constant-rate displacement (0.01–10⁶ μm/min), frequency sweep (0.001–1 Hz), multi-step program (up to 40 steps) |
| Optional Accessories | Automated liquid nitrogen cooling system (−150 °C to 600 °C), electronic cooler (−60 °C to 450 °C), fan-assisted ambient cooling (RT to 600 °C or 1500 °C), LN₂ Dewar kit (−170 °C to 600 °C), mass flow controller, humidity control module, expansion/compression/penetration/tensile/bending probes (quartz or alumina), sapphire dilatometry fixture |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model | TMA7100 / TMA7300 |
| Temperature Range | –170 °C to 600 °C (TMA7100) |
| Displacement Range | ±5 mm |
| Sensitivity (RMS Noise) | 0.005 µm / Resolution: 0.01 µm |
| Load Range | ±5.8 N (Resolution: 9.8 µN) |
| Heating Rate | 0.01–100 °C/min |
| Sample Max Dimensions | Ø10 mm × 25 mm (cylindrical) or 5 mm × 1 mm × 25 mm (film) |
| Probe Mounting | Cantilever-type |
| Atmosphere Control | Ambient, inert gas, vacuum (~1.3 Pa), optional humidity & swelling modules |
| Load/Displacement Control Modes | Constant force, constant rate, oscillatory (0.001–1 Hz), multi-step sequences (up to 40 steps) |
| Optional Cooling | Automated LN₂ cooling (–150 °C to 600 °C), electronic cooler (–60 °C to 450 °C), forced-air cooling (RT–600 °C), LN₂ Dewar kit (–170 °C to 600 °C) |
| Sample Tube Materials | Quartz (TMA7100), Alumina (TMA7300) |
| Probe Types | Expansion/compression quartz, penetration (standard & conical), tensile (quartz & metal), bending, sapphire dilatometry |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model | TMA7100/TMA7300 |
| Heating Rate | 0.01–100 °C/min |
| Temperature Range | –170 to 600 °C (standard) |
| Temperature Stability | ±0.1 °C over –170 to 600 °C |
| Maximum Sample Mass | ±400 mg |
| Atmosphere Control | Ambient air, inert gas (N₂, Ar), vacuum (~13 Pa)*² |
| Cooling Options | Liquid nitrogen (40% reduced consumption vs. prior models), optional Peltier-based electronic cooling |
| Gas Flow Control | Integrated mass flow controller for automated gas switching and precise atmosphere regulation |
| Humidity Capability | Optional high-temperature/humidity module for swelling and hygrothermal testing |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-Strata920 |
| Price Range | USD 68,000 – 136,000 |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | HGS-W21 (Wireless Indoor Temp/RH Logger), HGS-R5 (433 MHz Wireless Data Concentrator) |
| Communication | 433 MHz ISM-band RF (licensed by China NRR) |
| Storage | Onboard non-volatile memory (≥32,000 records per unit) |
| Alarm | Configurable high/low thresholds with local buzzer |
| Compliance | Designed to support GSP (China Good Supply Practice), GLP (Good Laboratory Practice), and archival environmental control per DA-001–2021 (National Archives Administration of China) |
| Connectivity | Up to 250 wireless sensors per concentrator (HGS-R5) |
| Software | Windows-compatible (Win7–11), real-time graphing, statistical reporting (min/max/avg), audit trail export (CSV/PDF), alarm log with timestamp and event annotation |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | HMD-1 |
| Measurement Principle | Oscillating U-tube (Digital Density Determination) |
| Sample Volume | 2 mL |
| Display | Color LCD with backlighted viewing window |
| Power | Rechargeable battery (≥6 h continuous operation) |
| Accuracy | ±0.001 g/cm³ |
| Temperature Control | Peltier-assisted (±0.02 °C stability) |
| Compliance | ISO 12084, ASTM D4052, USP <841> |
| Brand | Huameike (LABULK) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HMK-200 (01081623) |
| Principle | Air Jet Sieving |
| Measurement Range | 3–5000 µm |
| Maximum Load | 2000 g |
| Sieve Stages | Single-stage |
| Brand | LABULK |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Intelligent |
| Display | Digital Readout Panel, Touchscreen, PC Interface |
| Measurement Principle | Fisher Air Permeability (HMK-22), Air Jet Sieving (HMK-200), Static Light Scattering / Mie Theory (AS-2011) |
| Size Range | 0.2–50 µm (HMK-22), 3–5000 µm (HMK-200), 0.1–500 µm (AS-2011) |
| Repeatability | ≤3% (HMK-22), ≤3% (HMK-200), <1% (AS-2011) |
| Porosity Range | 0.25–0.95 (HMK-22) |
| Air Pressure | 0–10 kPa (HMK-200), 5 kPa (HMK-22) |
| Power Supply | 220 V / 50 Hz (all models), 110 V / 60 Hz (HMK-22 optional) |
| Weight | 18 kg (HMK-22), 14.8 kg (HMK-200), N/A (AS-2011) |
| Dimensions | 41.8 × 24.6 × 73.7 cm (HMK-22), 58 × 35 × 35 cm (HMK-200), N/A (AS-2011) |
| Compliance | ISO 13320-1 (AS-2011), ASTM B330 (HMK-22), ISO 4497 (HMK-200) |
| Brand | Hmsense |
|---|---|
| Origin | United Kingdom |
| Model | VL7-100B |
| Instrument Type | Oscillating Viscometer |
| Viscosity Range | 0–100,000 cP |
| Temperature Range | –20 to +120 °C |
| Sample Volume (Standard) | 100 mL |
| Sample Volume (Mini Probe Option) | 10 mL |
| Repeatability | <1% |
| Probe Weight | 700 g (Standard), 500 g (Mini) |
| Display Unit Weight | 500 g |
| Total Length | 305 mm (Standard), 215 mm (Mini) |
| Wetted Materials | ASTM A240 Grade 316 Stainless Steel |
| Housing Material | Delrin® (Polyoxymethylene, POM) |
| IP Rating | IP65 |
| Power Supply | 4 × AA Alkaline Batteries |
| Integrated Temperature Sensor | Yes |
| Calibration Correction | Real-time viscosity/temperature compensation |
| Sensing Surface Finish | Electro-polished Alloy C-22 (N06022) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | HNMC |
| Pricing | Upon Request |
| Reciprocating Speed | 30 cycles/min |
| Load | 200 ±10 g (6 abrasive heads), 300 ±5 g (6 additional weights), 500 ±5 g (2 additional weights) |
| Counter Range | 0–9999 |
| Stroke Length | 120 mm |
| Arc Radius of Test Bed | R200 mm |
| Motor Power | 25 W |
| Dimensions (L×W×H) | 350 × 470 × 310 mm |
| Weight | 34 kg |
| Brand | Hokuto Instruments (HOKUTOcn) |
|---|---|
| Origin | Dongguan, Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Class | Video-Based Optical Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.001° |
| Sample Stage Dimensions | 130 × 150 mm (customizable) |
| Max Sample Size | 200 (W) × ∞ (L) × 30 (H) mm |
| Surface/Interfacial Tension Range | 0.1–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Tilt Mechanism | Motorized whole-stage tilting for advancing/receding angle and roll-off angle measurement |
| Imaging | Sony 1/1.8″ progressive-scan CMOS sensor (1280 × 1024), 80 fps, rolling shutter |
| Illumination | Imported industrial-grade cold white LED backlight (400–760 nm), PWM-dimmable, >50,000 h lifetime |
| Software | CA V2.0 Static/Dynamic Contact Angle & Surface Energy Analysis Suite (Windows 10 64-bit) |
| Calibration | Traceable certified angle standards (5°, 8°, 30°, 60°, 90°, 120° optional) |
| Data Management | Audit-trail-enabled reporting (PDF/Excel/Word), GLP-compliant history database, role-based user access (operator/admin) |
| Brand | Hokuto Instruments (HOKUTOcn) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | CA/300 |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Meter |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.001° |
| Standard Sample Stage Size | 300 × 300 mm (customizable up to 1000 × 1000 mm) |
| Maximum Sample Dimensions | 300 mm (W) × ∞ (L) × 50 mm (H), customizable |
| Surface/Interfacial Tension Range | 0.1–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Surface/Interfacial Tension Resolution | 0.001 mN/m |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | HO-ED-S-04A |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 482 |
| Quotation | Available upon Request |
| Torque Range | 2.83 N·m to 1130 N·m |
| Analog Output | ±5 V DC or ±10 V DC (user-selectable) |
| Digital Interface | RS232C |
| Combined Accuracy (nonlinearity + hysteresis + nonrepeatability) | ±0.2% FS (Code N) / ±0.15% FS (Code C) |
| Rotational Effect on Zero | ±0.05% FS (Code N) / ±0.025% FS (Code C) |
| Thermal Zero Drift | ±0.007% FS/°F (Code N) / ±0.003% FS/°F (Code C) |
| Thermal Span Drift | ±0.007% reading/°F (Code N) / ±0.003% reading/°F (Code C) |
| Temperature Compensation Range | +75 to +150 °F |
| Operating Temperature Range | +32 to +175 °F |
| Nominal Overrange Capacity | 30% FS |
| Bessel Filter Cutoff Frequencies | 0.1–200 Hz (11 steps: 1–2–5 sequence) |
| System Resolution | 0.02% FS (±10 V) / 0.04% FS (±5 V) |
| Supply Voltage | 10–15 V DC @ 200 mA nominal |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 590 |
| Pricing | Available Upon Request |
| Measurement Range | 4.52 N·m to 83,000 N·m |
| Output Signals | ±5 V DC, 4–20 mA, mV/V |
| Frequency Response | 0–500 Hz |
| Power Supply | 10.5–24 V DC (nominal 12 V DC battery compatible) |
| Accuracy (combined nonlinearity/hysteresis/nonrepeatability) | ≤±0.10 % FS |
| Thermal Zero Drift | ≤±0.0025 % FS/°F |
| Thermal Span Drift | ≤±0.0025 % RDG/°F |
| Compensated Temperature Range | +75 to +175 °F |
| Operating Temperature Range | −25 to +185 °F |
| Storage Temperature Range | −65 to +225 °F |
| Overrange Capability | ±33 % FS |
| Bandwidth Options | DC–500 Hz (high-frequency mode), DC–1 Hz (low-frequency mode) |
| Intrinsic Safety Certification | Compliant with IEC 60079-11 (Ed. 5.0) and UL 913 Class I, Div 1, Groups A, B, C, D |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 790 |
| Pricing | Upon Request |
| Torque Range (Flange-Mounted) | 22.6–678,000 N·m |
| Torque Range (Shaft-Mounted) | 4.52–452,000 N·m |
| Speed Range (Flange-Mounted) | 0 to ±8,000 rpm |
| Speed Range (Shaft-Mounted) | 0 to ±15,000 rpm |
| Frequency Response | 0–500 Hz |
| Output Signal | ±5 V or ±10 V (bi-directional, dual-range) |
| Supply Voltage | 10.5–24 VDC (standard), 18–24 VDC (option L) |
| Current Consumption | 100 mA (nominal) |
| Zero & Span Adjustment Range | ±5% of range (nominal) |
| Combined Error (nonlinearity + hysteresis + nonrepeatability) | ≤±0.15% (low range), ≤±0.12% (high range) |
| Temperature Effect on Zero | ≤±0.0025% / °F (low range), ≤±0.001% / °F (high range) |
| Compensated Temperature Range | +75 to +175 °F |
| Operating Temperature Range | −25 to +185 °F |
| Storage Temperature Range | −65 to +225 °F |
| Output Noise (rms) | 0.10% of range @ 500 Hz, 0.02% @ 1 Hz |
| Measurement Bandwidth | DC–500 Hz (high-frequency output), DC–1 Hz (low-frequency output), simultaneously available |
| Minimum Resistive Load | 10 kΩ |
| Maximum Capacitive Load | 0.05 µF |
| Source Impedance | <1 Ω |
| Overrange Capability | ±33% of range |
| Origin | USA |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | 480 |
| Pricing | Available Upon Request |
| Torque Range | 0.071–452,400 N·m |
| Overload Capacity | 200% FS |
| Output Signals | ±5 V DC, ±10 V DC |
| Frequency Response | 1–500 Hz |
| Accuracy (Combined) | ≤±0.15% FS (Standard), ≤±0.08% FS (High-Precision Variant) |
| Thermal Zero Drift | ≤±0.003% FS/°F (Standard), ≤±0.0015% FS/°F (High-Precision Variant) |
| Compensated Temperature Range | +75 to +175 °F |
| Operating Temperature Range | −25 to +185 °F |
| Storage Temperature Range | −65 to +225 °F |
| Power Supply | 10.5–24 V DC @ 85 mA nominal |
| Bandwidth | DC to 500 Hz (high-frequency mode), DC to 1 Hz (low-frequency mode) |
| Zero Balance | ≤±1% FS |
| Rotational Effect on Zero | ≤±0.10% FS (Standard), ≤±0.03% FS (High-Precision Variant) |
| Calibration Traceability | NIST-traceable at 75 °F |
| Brand | Hongri Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRJ-C |
| Price | USD 8,200 (FOB) |
| Maximum Output Voltage | 20 kV AC/DC |
| Compliance | GB/T 1408.1–2016, GB/T 13542.1–2009, GB/T 1695–2005, GB/T 3333–1999 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-300 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–600 µm |
| Repeatability | <1% |
| Measurement Time | 20 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LA-350 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 100 nm – 1000 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-960 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01–5000 µm |
| Repeatability | < 0.1% |
| Measurement Time | < 10 s |
| Compliance | ISO 13320 |
| Accuracy | ±0.6% |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-960 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5 mm |
| Repeatability | ≤0.06% |
| Measurement Time | <1 min |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LA-960 V2 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5000 µm |
| Repeatability | ±0.1% |
| Measurement Time | 10 seconds |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Partica CENTRIFUGE CN-300 |
| Measurement Principle | Centrifugal Sedimentation |
| Measured Range | 10 nm – 40 µm |
| Maximum Centrifugal Force | 30,000 × g |
| Temperature Control | Integrated Peltier Cooling for Sample Cell and Rotor |
| Measurement Modes | Density Gradient Mode & Homogeneous Mode |
| Sample Volume | As low as 2 µL (undiluted) or 10 µL (diluted) |
| Compliance | IEC 61010-1:2010 / IEC 61010-2-020:2016 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SA-9650 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Gas Adsorption) |
| Number of Analysis Stations | 1–3 |
| Specific Surface Area Range | 0.10 to >2000 m²/g |
| Repeatability | RSD < 1% |