Physical Property Testing Instruments
Filter
Showing 10381–10410 of 12278 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | HAAKE Falling Ball |
| Instrument Type | Falling Ball Viscometer |
| Viscosity Range | 0.5 – 100,000 mPa·s |
| Temperature Range | −1 °C to +26 °C |
| Repeatability | < 0.5 % |
| Reproducibility | < 1 % |
| Measurement Tube Material | Borosilicate Glass (Tubes 1, 2, G) |
| Ball Materials | Nickel–Iron Alloy (Balls 3, 4, 5, 6) |
| Compliance | DIN 53015, ISO 120587 |
| Optional Accessories | Digital Stopwatch, Ball G (for gas viscosity), PT100 Temperature Sensor for HAAKE D50 Circulator |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MARS 40/60 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 10⁻⁸ rpm |
| Frequency Range | 10⁻⁶–100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1×10⁻⁸ rpm |
| Frequency Range | 1×10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Normal Force Range | 0.01 – 50 N |
| Normal Force Resolution | 0.001 N |
| Vertical Travel | 240 mm |
| Gap Resolution | 0.5 µm |
| Minimum Vertical Speed | 0.02 µm/s |
| Maximum Vertical Speed | 20 mm/s |
| Temperature Range (with optional modules) | −150 °C to +600 °C |
| Dimensions (W×D×H) | 600 × 600 × 890 mm |
| Weight | 59 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Model | HAAKE MiniLab II |
| Instrument Type | Torque Rheometer |
| Screw Configuration | Co-rotating and Counter-rotating Conical Twin-Screw |
| Minimum Speed | 1 rpm |
| Maximum Speed | 360 rpm |
| Frequency Range | 0.1–37.7 rad/s |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Motor Power | 400 W |
| Barrel Volume | 7 cm³ (≈5 g PE) |
| Max Temperature | 350 °C (optional 420 °C) |
| Max Pressure | 200 bar |
| Barrel Material | Stainless Steel (HRC55) |
| Screw Material | Stainless Steel 1.4122 |
| Cooling Method | Air/Water (350 °C version), Air-only (420 °C version) |
| Integrated Bypass Valve | Automated |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Torque Rheometer |
| Model | PolyLab OS |
| Motor Bearing | Screw-driven |
| Minimum Speed | 1 rpm |
| Frequency Range | 0.1–115 rad/s |
| Maximum Speed | 250 rpm (up to 1100 rpm optional) |
| Maximum Torque | 120 mNm (dual-range: 120/400 Nm) |
| Torque Resolution | 0.01 / 0.1 Nm |
| Temperature Range | Up to 400 °C (optional 450–500 °C) |
| Heating/Cooling | Electric heating + compressed air cooling |
| Control Zones | 7–10 independent temperature zones |
| Pressure Capability | Up to 700 bar |
| Barrel Design | Modular, horizontally split |
| Screw Configurations | Single-screw (Ø19.05 mm), Conical counter-rotating twin-screw (Ø31.8/20 mm), Parallel co-rotating twin-screw (Ø16/24 mm), Banbury-type mixer (120/625 cm³ chamber volume) |
| Power Supply | 7 kW / 16 kW |
| L/D Ratios | 10:1, 25:1, 33:1 (single-screw) |
| 25 | 1 to 40:1 (twin-screw) |
| Extrusion Capacity | ~5 kg/h (polymer-dependent) |
| Compliance | DIN 1.4301 stainless steel (mixer), DIN 1.8550 nitrided steel (screws/barrels) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HAAKE PolyLab OS |
| Instrument Type | Torque Rheometer |
| Screw Bearing | Precision Ball Screw |
| Minimum Speed | 1 rpm |
| Frequency Range | 0.1–115 rad/s |
| Maximum Speed | 250 rpm (up to 1100 rpm optional) |
| Maximum Torque | 120 / 400 Nm |
| Torque Resolution | 0.01 / 0.1 Nm |
| Power Rating | 7 kW / 16 kW |
| Mixing Chamber Volume | 120 cm³ or 625 cm³ |
| Screw Diameter | 19.05 mm (single-screw), 31.8 / 20 mm (conical counter-rotating twin-screw), 16 mm or 24 mm (parallel co-rotating twin-screw) |
| Screw L/D Ratio | 10:1, 25:1, 33:1 (single) |
| 25 | 1 to 40:1 (twin-screw) |
| Extrusion Output | ~5 kg/h (typical polymer feedstock) |
| Temperature Range | Up to 400 °C (optional 450–500 °C) |
| Heating/Cooling | Electric heating + compressed air cooling |
| Barrel Configuration | Modular, horizontally split |
| Max Pressure | 700 bar |
| Gear Ratio | 3:2 (optional 2:3) |
| Torque Accuracy | ±0.15% of full scale |
| Temperature Control Zones | 7–10 independent zones |
| Construction Materials | DIN 1.4301 stainless steel (mixing chamber), DIN 1.8550 nitrided stainless steel (screws) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PolyLab QC |
| Instrument Category | Torque Rheometer |
| Drive Bearing | Single-screw configuration |
| Minimum Speed | 1 rpm |
| Frequency Range | 1–21 rad/s |
| Maximum Speed | 200 rpm |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Torque Accuracy | ±0.15% of full scale |
| Temperature Range | Up to 450 °C (heating via electric cartridge heaters |
| Screw Material | Nitrided stainless steel (DIN 1.8550) |
| Chamber Material | Stainless steel (DIN 1.4301) |
| Mixer Chamber Volume | 120 cm³ or 625 cm³ |
| Screw Diameter | 19.05 mm (single-screw unit) / 31.8 mm & 20 mm (conical counter-rotating twin-screw unit) |
| Screw L/D Ratio | 25 |
| Screw Length | 300 mm |
| Gear Ratio | 3:2 |
| Maximum System Pressure | 700 bar |
| Power Rating | 4 kW |
| Control Interface | USB or optional Ethernet (LAN) |
| Software Platform | HAAKE PolySoft v7.x (Windows-based) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HAAKE PolyLab QC |
| Instrument Type | Torque Rheometer |
| Drive Configuration | Single-Screw Motor Drive |
| Minimum Speed | 1 rpm |
| Frequency Range | 1–21 rad/s |
| Maximum Speed | 200 rpm |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HAAKE RheoStress 1 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 0.025 rpm |
| Frequency Range | 0.0001–100 rad/s |
| Maximum Rotational Speed | 1200 rpm |
| Maximum Torque | 100 mNm |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Rotational Viscometer |
| Model | VT C / VT D / VT E |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Accuracy | ±1 % FSD |
| Repeatability | 0.2 % FSD |
| Speed Range | 0.01 – 200 rpm |
| Compliance | ISO 2555, ASTM D1084/D2196/D2556/D2983/D3232, BS 6075/5350 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Viscotester D (R-Version) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Viscometer |
| Model | HAAKE Viscotester D |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Compliance | ISO 2555 |
| Rotor Geometry | Standard Spindle (e.g., LV, RV, HA, HB series) |
| Shear Rate Range | Dependent on spindle geometry and rotational speed (typically 0.1–1000 s⁻¹) |
| Accuracy | ±1% of full scale (per ISO 2555 calibration requirements) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer |
| Motor Bearing | Air-bearing-free (direct-drive torque sensor) |
| Minimum Angular Velocity | 0.001 rad/s |
| Maximum Angular Velocity | 157 rad/s (≈1500 rpm) |
| Torque Range | 0.2–100 mN·m |
| Torque Resolution | 0.002 mN·m (0.2% of full scale) |
| Oscillation Frequency Range | 0.01–100 Hz (with optional oscillatory module) |
| Temperature Control | Peltier-based, -10 to +130 °C (with coaxial cylinder or cone/plate geometry) |
| Geometry Auto-Recognition | Yes |
| Interface | 7″ capacitive touchscreen + USB host/device + Ethernet |
| Software | HAAKE RheoApp (standalone on USB drive) and HAAKE RheoWin (PC-based, GLP-compliant) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q5000IR, Q500, Q50 |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | HAAKE RotoVisco 1 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Mechanical Bearing |
| Minimum Speed | 0.0125 rpm |
| Maximum Speed | 1000 rpm |
| Maximum Torque | 50 mN·m |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HAAKE Viscotester 1 plus & 2 plus |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1 plus: 1.5–330 mPa·s |
| 2 plus | 0.3–4000 dPa·s (30–400,000 mPa·s) |
| Rotational Speed | 62.5 rpm |
| Temperature Capability | up to 150 °C |
| Repeatability | ±1% FSD |
| Standard Accuracy | ±5% FSD |
| Optional High-Accuracy Accuracy (VT 2 plus only) | ±1% FSD |
| Display Units | VT 1 plus defaults to mPa·s |
| Unit Conversion | 1 mPa·s = 1 cP |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | HAAKE Viscotester C / D / E |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | L-type: 15–6,000,000 mPa·s |
| R-type | 100–40,000,000 mPa·s |
| Accuracy | ±1% FSD |
| Repeatability | ±0.2% |
| Speed Range | C/D: 0.1–200 rpm (21 speeds) |
| E | 0.01–200 rpm (54 speeds) |
| Compliance | ASTM D1084, D1286, D1439, D2196, D2556, ISO 2555, BS 6075 |
| Power Supply | 100–240 V, 50–60 Hz |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HAAKE Viscotester Falling Ball C |
| Instrument Type | Falling Ball Viscometer |
| Viscosity Range | 0.5 – 100,000 mPa·s (cP) |
| Temperature Range | −20 °C to +150 °C |
| Repeatability | < 0.5 % |
| Reproducibility | < 1 % |
| Tube & Balls 1–2 & G | Borosilicate Glass |
| Balls 3–6 | Ni-Fe Alloy |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Viscotester iQ |
| Instrument Type | Rotational Rheometer |
| Bearing Type | Mechanical Bearing |
| Minimum Angular Velocity | 0.001 rad/s |
| Frequency Range | 0.1 Hz – 20 Hz |
| Maximum Angular Velocity | 157 rad/s |
| Maximum Torque | 100 mNm |
| Torque Resolution | 0.01 mNm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | VT550 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 2 – 10⁷ mPa·s |
| Speed Range | 0.5 – 800 rpm |
| Torque Range | 0.1 – 50 mN·m (up to 400 rpm), 0.1 – 20 mN·m (up to 800 rpm) |
| Temperature Range | −40 °C to +350 °C (dependent on optional temperature control unit) |
| Compliance Standards | ISO 2555, ISO 3219, DIN 53018, DIN 53019 |
| Control Mode | Preset Programs (10 built-in), Controlled Deformation (CD) mode for yield stress determination |
| Software Integration | RheoWin (HAAKE proprietary software) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 21Plus-C Online X-ray Thickness Gauge |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Oscillating U-tube Densimeter (Note: Correction — actual principle is gamma-ray transmission, not oscillating tube |
| Instrument Category | Benchtop Laboratory / Industrial In-Line Density Meter |
| Detection Method | Non-contact Gamma-Ray Transmission Densitometry |
| Radiation Sources | Cs-137 or Co-60 |
| Density Measurement Principle | Attenuation-based gamma-ray transmission through process media |
| Temperature Operating Range | –40 °C to +75 °C |
| Environmental Rating | NEMA 4X / IP65 |
| Detector Configuration | Integrated or Remote (Split) |
| Multiplexing Capability | Up to 4 independent measurement channels per microprocessor unit |
| Analog I/O | 4 × 4–20 mA inputs, 2 × 4–20 mA outputs, 2 × 0–10 V inputs, 2 digital inputs, 2 relay outputs |
| Communication Interfaces | RS232 / RS485, 10/100 M Ethernet with ESD protection, USB |
| Power Supply | 115/230 V AC ±10%, 50/60 Hz or 24 V DC |
| Certified Compliance | IEC 60068-2-6 (sinusoidal vibration), IEC 60068-2-64 (random vibration), IEC 60068-2-27 (shock), IEC 60068-2-38 (temp/humidity cycling) |
| Radiation Safety | Lead-shielded source housing |
| activity range | 1–10,000 mCi (Cs-137) or 1,000–3,000 mCi (Co-60) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Upright Temperature and Humidity Controlled Chamber |
| Model | 3961 |
| Internal Volume | 29 cu ft (821.2 L) |
| Temperature Range | 5°C above ambient to 60°C |
| Temperature Uniformity | ±0.4°C at 30°C, ±0.3°C at 37°C, ±0.5°C at 45°C |
| Temperature Stability | ±0.1°C |
| Control System | Enviro-Scan™ Microprocessor |
| Construction | Exterior – Powder-coated cold-rolled steel |
| Insulation | 2 in. (5.1 cm) fiberglass |
| Door | Heated triple-pane tempered glass |
| Shelves | 5 standard, up to 26 max., solid stainless steel, adjustable on 2 in. centers |
| Shelf Load Capacity | 13.6 kg (30 lb) per shelf |
| Dimensions (L×W×H) | 83.8 × 78.7 × 203.2 cm (33 × 38 × 80 in.) |
| Internal Dimensions (L×W×H) | 65.5 × 77.7 × 152.4 cm (25.8 × 30.6 × 60 in.) |
| Port Configuration | Two 2.4 in. (6.1 cm) I.D. access ports, one per side |
| Electrical Requirements | 200/230 V, 50/60 Hz, 5 A, 150 W |
| Safety Certifications | UL Listed, CE Marked |
| Overtemperature Protection | Independent mechanical thermostat + precision thermistor |
| Alarms | Audible/visual high/low temperature alarm |
| Data Output | Analog voltage output for external monitoring systems |
| Mobility | Locking casters + adjustable leveling feet |
| Brand | Thermo Scientific HAAKE |
|---|---|
| Origin | Germany |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air-bearing |
| Minimum Rotational Speed | 0.001 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Torque Range | 0.007 µNm – 150 mNm |
| Torque Resolution | 0.007 µNm |
| Frequency Range | 0.0001 – 209.4 rad/s |
| Frame Architecture | Folded H-Frame with Mineral Composite Base |
| Compliance | ASTM D4402, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11 (optional software module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | MARS iQ |
| Instrument Category | Rotational Rheometer |
| Bearing Type | Mechanical Ball Bearing |
| Minimum Rotational Speed | 0.01 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Frequency Range | 0.01–20 Hz |
| Maximum Torque | 125 mN·m |
| Torque Resolution | 2.0 µN·m |
| Brand | Thermo Scientific HAAKE |
|---|---|
| Origin | Germany |
| Model | MARS iQ |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Ball Bearing |
| Minimum Rotational Speed | 0.01 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Torque Range | 0.002–125 mNm |
| Torque Resolution | 2.0 µNm |
| Frequency Range | 0.001–209.4 rad/s |
| Frame Architecture | Folded H-Frame with Mineral Composite Construction |
| Temperature Control Interface | Auto-recognized, Color-Coded Modular System |
| Software Platform | HAAKE RheoWin (with optional 21 CFR Part 11 compliance module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer Coupling Module |
| Model | Rheonaut |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1 × 10⁻⁸ rpm |
| Frequency Range | 10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 0.1 nN·m |
| ATR Crystal Material | Diamond (Single-Reflection) |
| Temperature Control Options | Peltier (0–120 °C) or Electric Heating (RT–400 °C) |
| Detector | DTGS |
| Polarization Options | Manual/Automatic Dual-Axis Polarizers |
| Compliance | ASTM D3835, ISO 6721-10, USP <1043>, GLP/GMP-ready data audit trail support |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Materials Characterization |
| Instrument Type | Torque Rheometer |
| Motor Bearing | Not Applicable |
| Minimum Rotational Speed | Not Specified |
| Maximum Rotational Speed | Not Specified |
| Frequency Range | Not Specified |
| Maximum Torque | Not Specified |
| Torque Resolution | Not Specified |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific Process Thickness Gauge |
| Price Range | USD 70,000 – 140,000 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Models | FD910, FD950, FD960, FD900, ID900, PD900 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop & In-line Process |
| Application Focus | Petroleum, Petrochemical, Chemical, LNG, and Power Generation |
| Density Range (Liquid) | 0–2100 kg/m³ |
| Density Range (Gas) | 0–1000 kg/m³ (FD900/ID900), 0–250 kg/m³ (PD900) |
| Accuracy (Liquid) | ±0.1 kg/m³ |
| Repeatability (Liquid) | 0.02 kg/m³ |
| Temperature Compensation | Integrated 4-wire PT100 (1/3 DIN) |
| Operating Temp (Liquid) | −50°C to +180°C |
| Operating Temp (Gas) | −200°C to +200°C |
| Pressure Rating | Up to 170 bar (FD900), 150 bar (ID900), 100–150 bar (PD900) |
| Enclosure Rating | IP65 / NEMA 4X |
| Hazardous Area Certifications | ATEX Ex ia IIC T4/T6, CSA Class I Div 1 Groups B, C, D, IECEx, NACE MR0175/ISO 15156 compliant |
| Output Options | 4–20 mA + HART (HME900), Frequency/Modulated Current (CM515), Dual-Channel PT100 |
| Calibration | NIST-traceable, performed in ISO/IEC 17025-accredited laboratory |