Physical Property Testing Instruments
Filter
Showing 10411–10440 of 12278 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ELITE |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ThermoConcept |
| Pricing | Upon Request |
| Brand | NANJING DAZHAN |
|---|---|
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Max Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static/dynamic) |
| Balance Resolution | 0.1 µg |
| Balance Accuracy | ±0.01 mg |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit color touchscreen |
| Communication | USB 2.0 bidirectional interface |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, GLP-compliant report generation |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | TGA 1000 |
| Temperature Range | RT–1000°C |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.1–300 K/min |
| Maximum Sample Mass | 0.4 g |
| Sample Capacity | Single |
| Environment | High-Temperature/Controlled-Atmosphere |
| Construction | Stainless Steel Gas Pathway |
| Cooling | Water-Cooled Furnace |
| Software Platform | Infinity Pro for Windows |
| Compliance | ASTM E1131, ISO 11358, USP <691>, GLP-Ready |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | TGA 1500 |
| Temperature Range | RT–1000 °C |
| Balance Sensitivity | 0.1 μg |
| Heating/Cooling Rate | 0.1–300 K/min |
| Maximum Sample Mass | 0.4 g |
| Sample Capacity | Single |
| Environment | High-Temperature/Controlled-Atmosphere |
| Construction | Stainless-Steel Dual-Gas Purge System |
| Software Platform | Infinity Pro for Windows |
| Optional Modules | EGA Interface with Heated Transfer Line, Auto Gas Switching, Step ISO Compliance Mode, Water-Cooled Furnace |
| Brand | Thermtest |
|---|---|
| Origin | Canada |
| Model | TLS-100 |
| Measurement Principle | Transient Line Source Method |
| Thermal Conductivity Range | 0.1–5 W/m·K |
| Thermal Resistance Range | 0.2–10 m·K/W |
| Accuracy | ±5% |
| Repeatability | ±2% |
| Measurement Duration | 120 s |
| Operating Temperature Range | −40 to 100 °C |
| Minimum Sample Dimensions | Ø50 mm × 100 mm (L) |
| Probe Diameter | 1.6 mm |
| Data Storage | Internal memory + SD card (FAT32 formatted, up to 32 GB) |
| Compliance | ASTM D5334-22 |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Weight | 1.2 kg |
| Dimensions (L×W×H) | 50 mm × 100 mm × 220 mm |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Theta-3D |
| Instrument Class | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Angular Resolution | 0.1° |
| Sample Stage Dimensions (L × W × H) | Unlimited × 180 mm × 22 mm |
| Image Resolution | 1280 × 960 pixels |
| Surface & Interfacial Tension Range | 0–1000 mN/m |
| Brand | Theva |
|---|---|
| Origin | Germany |
| Model | TAPESTAR™ |
| Critical Current Range | 50–400 A (TAPESTAR™), 50–1000 A (TAPESTAR™ XL) |
| Measurement Principle | Non-contact magnetic induction (perpendicular field scanning with multi-channel Hall sensor array) |
| Operating Temperature | Liquid nitrogen (77 K) |
| Tape Speed | 0–55 m/h (TAPESTAR™), 0–200 m/h (TAPESTAR™ XL) |
| Axial Resolution | 0.5 mm @ 55 m/h (TAPESTAR™), 1 mm @ 55 m/h (TAPESTAR™ XL) |
| Transverse Resolution | 0.6 mm (4 mm tape), 1.5 mm (10 mm tape) |
| Magnetic Field Range | 0–40 mT (TAPESTAR™), 0–120 mT (TAPESTAR™ XL) |
| Sensor Channels | 7 (TAPESTAR™), 21 (TAPESTAR™ XL) |
| Accuracy | ±3% (≥15 A, calibrated reference sample) |
| Tape Width Customization | Up to 12.4 mm |
| Max. Tape Thickness | 200 µm |
| Tape Tension Control | 5 N (TAPESTAR™), 5–11 N (TAPESTAR™ XL) |
| Power Supply | 220 V / 50 Hz / 250 W (TAPESTAR™), 400 V / 3-phase / 50 Hz / 3 kW (TAPESTAR™ XL) |
| Dimensions (L×W×H) | 750 × 710 × 860 mm (TAPESTAR™), 2630 × 880 × 1550 mm (TAPESTAR™ XL) |
| Weight | 98 kg (TAPESTAR™), 475 kg (TAPESTAR™ XL) |
| Environmental Requirements | 5–35 °C, 10–90% RH (non-condensing), vibration-isolated installation |
| Brand | Thicktest |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | SKT-500 |
| Pricing | Upon Request |
| Brand | Thorlabs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MC2000 |
| Pricing | Upon Request |
| Brand | Thorlabs |
|---|---|
| Origin | USA |
| Model | SPL-LEDD |
| Output Current Range | 0–1000 mA (DC4100 variant), 0–2000 mA (DC2100 variant), 0–1200 mA (LEDD1B variant) |
| Forward Voltage Compliance | 5 V (DC4100), 12 V (LEDD1B), 24 V (DC2100) |
| Modulation Bandwidth | DC–100 kHz (sine/arbitrary), up to 100 MHz internal (DC3100 series) |
| Trigger Input | 0–5 V TTL-compatible |
| USB Interface | USB 2.0 with CDC-class enumeration |
| Control Modes | Constant Current, Analog Modulation, External Trigger, PWM Pulse Sequencing |
| Software Support | µManager plugin, Thorlabs Kinesis, LabVIEW VIs |
| Compliance | CE, RoHS, FCC Class B |
| Key Features | Three-chamber design (hot, cold, test chambers) |
|---|---|
| Controller options | TEMI880 color touchscreen programmable temperature/humidity controller (English/Chinese switchable) or TEMI300 membrane-key programmable controller (English only) |
| Protection functions | Compressor overheat/overcurrent/overpressure protection, heater dry-run prevention, chamber over-temperature alarm, low-water-level detection |
| Standard configuration | Double-glazed tempered observation window |
| Temperature/humidity control | Balanced Temperature and Humidity Control System (BTSC) |
| Operating ambient | +5°C to +35°C |
| Heating | Nickel-chromium alloy wire heaters |
| Humidification | Surface evaporation type |
| Air circulation | Wide-band forced-air system (top discharge, bottom intake) |
| Cooling method | Air-cooled |
| Refrigeration | Original French “Tecumseh” hermetic compressors |
| Refrigeration circuit | Single- or dual-stage low-temperature loop design |
| Construction | Outer shell — SUS304B stainless steel |
| Airflow | Multi-wing centrifugal blower |
| Compliance | Designed to support ISO 16750-4, JEDEC JESD22-A104, MIL-STD-810H Method 503.5, IEC 60068-2-14, and ASTM D4332 test protocols |
| Key | High-Temp Zone: +60 °C to +200 °C |
|---|---|
| Low-Temp Zone Options | −10 °C to −40 °C / −10 °C to −60 °C / −10 °C to −70 °C |
| Test Chamber Range | 0 °C to −40 °C / −10 °C to −55 °C / −10 °C to −65 °C |
| Temp. Fluctuation | ±0.5 °C |
| Temp. Uniformity | ±3 °C |
| Temp. Recovery Time | 3–5 min |
| Heat-up Rate (HT Zone) | ~5 °C/min (avg.) |
| Cool-down Rate (LT Zone) | ~1.5 °C/min (avg.) |
| Dwell Time per Stage | ≥30 min |
| Transfer Time (Chamber-to-Chamber) | ≤15 s |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +150 °C |
| Thermal Shock Conditions | −40 °C ↔ +70 °C and −55 °C ↔ +85 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Stability | ≤ ±0.5 °C |
| Transfer Time (Cold ↔ Hot) | ≤ 5 s |
| Temperature Recovery Time | ≤ 5 min |
| Control Resolution | 0.1 °C / 1 s |
| Programmable Capacity | 10 programs × 99 segments |
| Compliance | GB/T 2423.22–1989, GJB 150.5A–2009, MIL-STD-810G Method 503.5 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | –40 °C to +150 °C (optional down to –120 °C) |
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Cooling Rate | 0.7–1.0 °C/min |
| Heating Rate | 2.0–3.0 °C/min |
| Control System | TEMI880 Color LCD Touchscreen Programmable Controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G |
| Inner Chamber Material | SUS304 Stainless Steel |
| Outer Casing | SUS304 Stainless Steel or A3 Steel with Electrostatic Powder Coating |
| Compliance | GB/T 5170.2–1996, GB/T 5170.5–1996, GB 2423.1–1989, GB 2423.2–1989, GB 2423.22–1987, GB 10589–1989, GB 10592–1989, GB 11158–1989 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | –40 °C to +150 °C (optional down to –120 °C) |
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temp. Uniformity | ±0.5 °C |
| Temp. Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 Color LCD Touchscreen Programmable Controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G |
| Inner Chamber Material | SUS304 Stainless Steel |
| Compliance | GB/T 5170.2, GB/T 5170.5, GB 2423.1, GB 2423.2, GB 2423.22, GB 10589, GB 10592, GB 11158 |
| Key Features | Three-zone design (high-temperature chamber, low-temperature chamber, test chamber) |
|---|---|
| Programmable memory | 100 test profiles, up to 9999 cycles, max 999 h 59 min per segment |
| Data logging | paperless real-time curve display and archival |
| Compliance | MIL-STD-202, IEC 60068-2-14, JIS C 60068-2-14 |
| Optional | LN₂ rapid-cooling module, RS-485/RS-232C communication interface, external temperature data logger |
| Safety | PLC-controlled fault detection, automatic emergency shutdown on power fluctuation, dual thermal overprotection |
| Key Features | Three-zone design (hot zone, cold zone, test zone) |
|---|---|
| Temperature Range | Hot Zone: +80°C to +200°C |
| Cold Zone | −10°C to −70°C |
| Test Zone Operating Range | −10°C to +150°C |
| Temperature Control Accuracy | ±2°C |
| Resolution | 0.1°C |
| Hot Zone Ramp Rate | ~60 min (from ambient to +150°C) |
| Cold Zone Ramp Rate | ~120 min (from ambient to −60°C) |
| Test Zone Recovery Time | ≤3 min (with standard 2 kg I.C. load) |
| Internal Dimensions (Test Zone) | 500 × 350 × 500 mm (W×H×D) |
| External Dimensions | Approx. 1600 × 2050 × 2220 mm (W×H×D) |
| Construction | SUS304 stainless steel interior |
| Exterior | High-tensile cold-rolled steel with solvent-free powder coating |
| Insulation | Fire-retardant PU foam + glass wool, 100 mm thick |
| Compliance | GB10592–1989, GB2423.1, GB2423.2, GJB150.3, GJB150.4, IEC 60068-2-14, MIL-STD-810G |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | High Zone: +150°C to +200°C |
| Low Zone | -70°C to -40°C |
| Test Zone | -65°C to +180°C |
| Transition Time (5% Recovery) | ≤15 s (Typical, per IEC 60068-2-14) |
| Cycle Count | Up to 9999 Cycles |
| Soak Time per Zone | Adjustable 1–9999 min |
| Cooling System | Dual-Stage Cascade Refrigeration (Air-Cooled or Water-Cooled Options) |
| Control Interface | 7″ Full-Color TFT LCD Touchscreen with Bilingual (English/Chinese) GUI |
| Data Logging | Optional External Recorder or PC-Connected USB/RS485 Interface |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810H Method 503.5, GJB 150.5A-2009, GB/T 2423.22–2012, ASTM D6279–20 |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model Range | THV-1000 |
| Temperature Range | -70°C to +100°C |
| Humidity Range | 30–98% RH |
| Temperature Uniformity | ≤2°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±2°C |
| Humidity Uniformity | ±2/−3% RH (≥75% RH) |
| Internal Dimensions | 1000 × 1000 × 1000 mm |
| Static Load Capacity | 50 kg |
| Air Velocity | 1.0–3.0 m/s (VFD-controlled) |
| Power Supply | 380 V, 50 Hz, 3-phase 5-wire |
| Total Power | 36 kW |
| Compliance Standards | GB 10586–1989, GB 10592–1989, GJB 150.16–1986 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FP-2260 |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Electromechanical Universal Testing System |
| Temperature Range | 21–176.7 °C (70–350 °F) |
| Maximum Load Capacity | 10 kgf (22 lbf) |
| Crosshead Travel | 355 mm (14 in) |
| Test Area | 225 mm × 350 mm |
| Load Cell Options | 1, 2, 5, and 10 kgf |
| Display | 240 × 64 pixel LCD |
| Data Storage | 128 test records |
| Communication Interfaces | USB & RS-232 |
| Compliant Standards | ASTM D1894, D4521, D2534, D6862, D6252, D3330, D1876, F88 |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | HOM |
| Maximum Test Force | 1000 g |
| Frequency Range | 50/60 Hz |
| Host Weight | 22.2 kg |
| Measurement Range | 0–100 g / 0–1000 g |
| Resolution | 0.1 g |
| Adjustable Slit Widths | 5, 10, 20 mm and 1/4 in |
| Display | 2 × 40-character LCD |
| Power Supply | 220 V ±10%, 50 Hz |
| Sample Size | 203.3 mm × 203.2 mm |
| Dimensions (L×W×H) | 304.8 × 254.0 × 317.5 mm |
| [Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | PCA-1270 |
| Load Cell Options | 500 g, 2000 g (standard), 5000 g, 10000 g |
| Force Accuracy | ±0.25% F.S. |
| Bending Mode Speed | 11.46°/sec |
| Score (Unfolding) Mode Speed | 5–500 mm/min |
| Angular Range | 0–90° (adjustable) |
| Angular Resolution | <0.2° |
| Displacement Accuracy | ±0.1% F.S. |
| Sample Width (Bending) | up to 152.4 mm |
| Sample Length (Score) | 25.4–457.2 mm |
| Pneumatic Pressure Requirement | 5.2 bar (75 psi) |
| Power Supply | 220 V ±10%, 50 Hz, 250 VA |
| Standby Power | 11 W |
| Test Power | 90 W |
| Fuse | 0.5 A @ 230 VAC |
| Analog Output | 1 V |
| Dimensions (W×D×H) | 610 × 483 × 1143 mm |
| Net Weight | 41 kg |
| Display Units | g, oz, lb, N, kg (force) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Progage |
| Pricing | Upon Request |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | ProGage Touch Thickness Tester |
| Measuring Range | 40–500 mil (1–12.7 mm) |
| Accuracy | ±0.00004–±0.0005 in (±0.001–±0.013 mm) |
| Display Resolution | 0.00001–0.0001 in (0.01–0.1 µm) |
| Parallelism | ±0.00004–±0.0005 in (±0.001–±0.013 mm) |
| Pressure Foot Diameter | 0.19–2.221 in (4.83–56.41 mm) |
| Anvil Diameter | 2.5 in (63.5 mm) standard, 4.25 in (107.9 mm) optional |
| Dwell Time | 0–20 s adjustable |
| Measurement Speed | 0.013–12.7 mm/sec |
| Sampling Rate | 128 Hz |
| Power | 120–230 VAC, 50–60 Hz, 36 VA |
| Dimensions | 255 × 318.5 × 403.9 mm |
| Net Weight | 24.7 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QC-3A |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Type | Electromechanical Universal Testing Machine |
| Model | Vantage |
| Force Capacity | 0–1 kN |
| Optional Load Cells | 5 N to 1 kN |
| Force Accuracy | ±0.25% of reading |
| Crosshead Travel | 609.6 mm |
| Vertical Test Space | 89 mm |
| Speed Range | 1.27–1016 mm/min |
| Power Supply | 220 V, 60 Hz |
| Safety Features | Emergency stop button, upper/lower limit switches, overload protection |
| Interface | RS-232 serial port |
| Control Software | MAP (Materials Analysis Program) for Windows |
| Actuation | Electronically controlled pneumatic grips |
| Calibration | Automated electronic zeroing and simplified calibration routine |
| Control Panel | Magnetic, repositionable |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VantageNX Series |
| Price Range | USD $38,000 – $64,000 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacities | 1 kN, 2 kN, 5 kN (VantageNX Duo), 10 kN (EJA Vantage Series) |
| Frame Configurations | Single-Column (406 mm × 432 mm footprint), Dual-Column (584 mm × 483 mm footprint) |
| Software | MAP4 v5.x (Windows 10 compatible, PC required, not included) |
| Compliance Standards | ASTM E4, ASTM F88, ASTM D790/D791/D882/D3330, ISO 5893/7500-1/9283, EN 10002-1 to -4, TAPPI T494/T541/T811/T825/T839, DIN, FINAT, PSTC, WSP |