Physical Property Testing Instruments
Filter
Showing 1231–1260 of 12269 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M4 TORNADO |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | Opterra II |
| Type | Multipoint Scanning Confocal Microscope |
| Application Focus | Live-Cell Quantitative Imaging |
| Optical Architecture | Dual-Galvo Scanning with High-Density Pinhole Array |
| Excitation Compatibility | 405–640 nm Laser Lines |
| Z-Step Resolution | Adjustable down to 100 nm |
| Maximum Z-Stack Acquisition Speed | ≤60 s for 56 slices at 2 µm intervals |
| Field Uniformity | <±1.5% Intensity Variation Across FOV |
| Phototoxicity Profile | Optimized for Extended Time-Lapse Imaging of Sensitive Specimens |
| Compliance | Designed for GLP/GMP-Compliant Workflow Integration |
| Software Platform | Prairie View™ v6.x with FDA 21 CFR Part 11 Audit Trail Support |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PI 89 |
| Pricing | Available Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SKYSCAN 1273 |
| X-ray Source Energy | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel, 3072 × 1944 pixels |
| Spatial Resolution | < 5 µm (3D) |
| Voxel Size | < 3 µm |
| Maximum Sample Dimensions | Ø300 mm × H500 mm, up to 20 kg |
| Field of View | Ø250 mm × H250 mm |
| Image Matrix | up to 4800 × 4800 pixels |
| Detector Output Speed | High-frame-rate acquisition enabled |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1273 |
| X-ray Source | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel (3072 × 1944 pixels) |
| Spatial Resolution | < 5 µm |
| Voxel Size | < 3 µm |
| Max Sample Dimensions | Ø250 mm × H250 mm |
| Max Sample Weight | 20 kg |
| Reconstructed Volume | up to 4800 × 4800 pixels |
| External Dimensions | 1250 × 815 × 820 mm (W × D × H) |
| Radiation Leakage | < 1 µSv/h at any point on external surface |
| Power Supply | 100–240 V, 50–60 Hz, 3 A |
| Weight | 400 kg (net) |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan 1275 |
| X-ray Source | 20–100 kV, 10 W, < 5 µm focal spot size at 4 W |
| Detector | 3 MP CMOS flat-panel detector (1944 × 1536 effective pixels) |
| Spatial Resolution | < 4 µm (nominal, at maximum magnification) |
| Density Resolution | < 4 µm (nominal, inferred from spatial resolution and contrast transfer performance) |
| Sample Capacity | Max height 120 mm, max diameter 96 mm |
| Dimensional Measurement Accuracy | Consistent with < 4 µm spatial resolution under calibrated conditions |
| Density Measurement Accuracy | Supported by high dynamic range (16-bit) detector and beam-hardening correction algorithms |
| Power Requirement | Standard 230 V AC, 50/60 Hz, single-phase outlet |
| Radiation Safety | Compliant with IEC 61000-6-3, IEC 61000-6-4, and national regulatory requirements for Class II B radiation devices |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 2211 |
| X-ray Source | 20–190 kV, 4/10/25 W, sub-micron focal spot size, 5-position filter wheel |
| X-ray Target | Tungsten (standard) |
| Detector | 3 MP CMOS flat panel (1920 × 1536 px) or 11 MP cooled CCD (4032 × 2670 px) |
| Reconstruction Volume (CMOS) | up to 3776 × 3776 × 1160 px (dual offset mode) |
| Reconstruction Volume (CCD) | up to 8000 × 8000 × 2272 px (dual offset mode) |
| Spatial Resolution | down to 100 nm (detector-limited, geometry-dependent) |
| Sample Capacity | Ø204 mm × L200 mm, max. 25 kg |
| Sample Positioning | direct-drive air-bearing rotation stage with integrated piezo-driven micro-positioning (5.5 mm travel) |
| Reconstruct Time | 1 min 12 sec (600 projections, 2K × 2K × 1K) |
| Radiation Safety | <0.5 µSv/h at 10 cm from surface (measured at 190 keV, 4 W on target) |
| Power Supply | 100–130 V or 200–240 V AC, 50–60 Hz |
| Cooling & Air Supply | integrated closed-loop water chiller and oil-free air compressor with particle filters and desiccant dryer |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Voxel Resolution | <0.35 µm (16 MP detector) / <0.45 µm (11 MP detector) |
| Max Reconstructed Volume | 14456 × 14456 × 2630 px (16 MP) or 11840 × 11840 × 2150 px (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm (standard) |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Spatial & Density Resolution | <0.35 µm (16 MP) / <0.45 µm (11 MP), isotropic voxel capability |
| Reconstruction Engine | InstaRecon® real-time GPU-accelerated 3D reconstruction |
| Scan Modes | Cone-beam, helical, phase-contrast enabled, dynamic time-lapse |
| Compliance | Fully compatible with ASTM E1441, ISO 15732, and USP <1059> for non-destructive volumetric analysis |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Reconstruction Volume | 14456 × 14456 × 2630 px (16 MP detector) or 11840 × 11840 × 2150 px (11 MP detector) |
| Spatial Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Density Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | TI 980 |
| Instrument Type | Nanoindentation and Scratch Tester |
| Key Technology | Three-Plate Capacitive Transduction |
| Compliance | ASTM E2546, ISO 14577, ISO 20503, USP <1062> |
| Optional Modules | High-Temperature Stage, Electrical Characterization Module, Humidity Control Chamber, Cryogenic Stage, Raman Coupling Interface |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TI 980 |
| Price Range | USD $260,000 – $390,000 |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | TI 990 |
| Drive Technology | Electrostatic actuation |
| Noise Floor | <0.1 nm RMS displacement noise |
| Maximum Load Resolution | 50 nN |
| Depth Resolution | <0.01 nm |
| Active Vibration Isolation | Integrated pneumatic + electromagnetic hybrid system |
| Platform | Precision granite base with environmental enclosure |
| Control Architecture | Performech III dual-lock-in parallel processing module |
| Software Platform | Tribo iQ v4.x (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready reporting) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TI Premier II |
| Instrument Type | Nanoindentation and Scratch Tester |
| Measurement Principle | Capacitive Displacement Sensing with Electromechanical Actuation |
| Compliance Framework | ASTM E2546, ISO 14577, ISO 20519, USP <1062>, GLP/GMP-Ready Data Integrity Architecture |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TriboLab CMP |
| Instrument Type | Multifunctional Tribological Tester |
| Maximum Friction Force | 200 N |
| Friction Force Resolution | 10 mN |
| Maximum Operating Temperature | 1000 °C |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | TriboLab |
| Instrument Type | Multi-Function Tribological Tester |
| Maximum Friction Force | 2000 N |
| Force Resolution | 10 mN |
| Maximum Temperature | 1000 °C |
| Vertical Travel | 150 mm (0.5 µm resolution) |
| Horizontal Travel | 75 mm (0.25 µm resolution) |
| Linear Drive Speed | 0.002–10 mm/s |
| Rotational Drive Speed | 0.1–5000 rpm |
| Reciprocating Frequency | 0.1–60 Hz |
| Stroke Range | 0.1–25 mm |
| Torque Capacity | 5 N·m @ 100 rpm / 2.5 N·m @ 5000 rpm |
| Data Acquisition | 16-bit, up to 200 kHz (8 standard channels, expandable to 16) |
| Environmental Control Options | −30 °C to 1000 °C temperature chamber, 5–85% RH humidity control, liquid immersion cell, cryogenic cooling, programmable fluid pump (2.2–480 mL/min) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution Scientific CMOS Sensor |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | 2 µm |
| Density Resolution | <1% |
| X-ray Energy | 110 kV |
| Maximum Sample Dimensions | Ø110 mm × 300 mm (H) |
| Max Sample Weight | 5 kg |
| System Footprint | 1250 × 960 × 690 mm (L × D × H) |
| Precision Level | Nanoscale |
| Configuration | Modular Benchtop Micro-CT Platform |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution sCMOS Semiconductor Sensor |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | ≤2 µm (JIMA-verified) |
| System Architecture | Modular, Field-Upgradable |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NY-715E2 |
| Pricing | Upon Request |
| Test Stations | 2 |
| Sample Size | 140 × 140 mm |
| Rotational Speed | 60 ± 2 rpm |
| Tumbler Geometry | Octagonal, Flat-to-Flat Width 224.5 mm, Depth 228 mm |
| Snagging Pins per Tumbler | 4 rods × 20 pins each |
| Pin Diameter | 1 mm |
| Pin Inclination Angle | 60° |
| Pin Protrusion Length | 5 mm |
| Sample Mounting Tube ID | 25 ± 1 mm, Wall Thickness: 3 ± 0.5 mm, Length: 70 ± 1 mm (4 tubes per tumbler) |
| Cycle Counter Range | 0–999,999, Programmable |
| Control Interface | Industrial Touchscreen HMI |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BS5852 |
| Pricing | Available Upon Request |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Instrument |
| Model | M-560 / M-565 |
| Temperature Range | Ambient to 400 °C |
| Heating Rates | 0.1, 0.2, 0.5, 1, 1.5, 2, 2.5, 3, 5, 10, 20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.3 °C (≤100 °C), ±0.5 °C (≤250 °C), ±0.8 °C (≤400 °C) |
| Capillary Dimensions | 80 mm length × 1 mm diameter |
| Sample Capacity | 3 samples for melting point determination (M-565: automated & visual) |
| Temperature Resolution | 0.1 °C |
| Display | 3.5″ color TFT (320 × 240) |
| Heating Time | ~4 min (50 → 350 °C) |
| Cooling Time | ~10 min (350 → 50 °C) |
| Power Consumption | 150 W |
| Certifications | CE, UL |
| Dimensions (W × D × H) | 190 × 200 × 370 mm |
| Weight | 4.5 kg |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMP10 |
| Pricing | Available Upon Request |
| Brand | Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 630 (FOB) |
| Standards Compliance | ISO 2759, ASTM D2210, TAPPI T403, GB/T 6545, JIS L1004/L1018/L1031, QB/T 1057 |
| Test Principle | Hydraulic (Silicone Oil-Based) Diaphragm Bursting |
| Clamping Method | Pneumatic Dual-Plate Clamp |
| Display | High-Resolution LCD with Onboard Data Storage (50 Tests) |
| Output | Integrated Thermal Printer |
| Safety | Emergency Stop Button, Real-Time Air Pressure Gauge |
| Sample Thickness Range | Up to 18 mm |
| Repeatability | ≤±2.0% (per ISO 2759 Annex B) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 630 (FOB) |
| Standards Compliance | ISO 2759, ASTM D2210, TAPPI T403, GB/T 6545, JIS L1004/L1018/L1031, QB/T 1057 |
| Brand | A2PS/A2 Photonic Sensors |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | BUZZ-1015 |
| Pricing | Upon Request |
| Measurement Principle | Impulse Excitation / Laser Doppler Vibrometry |
| Frequency Range | 0.5 Hz – 2.5 MHz |
| Accuracy | Better than ±1.0% (resonance frequency), ±0.1% typical for fundamental mode identification |
| Test Duration | Seconds per measurement |
| Damping Factor Range | 10⁻⁵ – 10⁻¹ |
| Sample Dimensions | ≤ 200 × 180 × 180 mm (rectangular or cylindrical) |
| Temperature Range | Ambient to 1500 °C (protection limit) |
| Vacuum Level | < 1 × 10⁻² Pa (operational), < 5 × 10⁻⁸ Torr (base pressure) |
| Compliant Standards | ASTM C1259, ASTM E1876, ISO 12680 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Buzz-1500NV |
| Pricing | Upon Request |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | A-0510 |
| Viscosity Range | 0.50–5.50 St (Stokes) |
| Tube Count | 20 calibrated glass tubes (A through T) + 2 Grade-A blank tubes |
| Tube Internal Diameter | 10.65 ± 0.025 mm |
| Bubble Path Length | 73 mm |
| Compliance | ASTM D1545, ISO 2431 (bubble method), DIN 53211 |
| Temperature Control Required | Yes (standardized at 25 °C or 30 °C per ASTM) |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK-3501 (25–2000 µm) / BYK-3504 (5–150 µm) |
| Construction | Hexagonal stainless steel body |
| Measurement principle | Mechanical comb gauge (contact-based stepwise interpolation) |
| Compliance | Designed per ISO 2808, ASTM D1212, and DIN 53210-1 |
| Brand | BYK-Gardner |
|---|---|
| Origin | Germany |
| Model | BYK 5120 / 5121 / 5122 / 5123 / 5125 / 5126 / 5127 / 5128 |
| Standards Compliance | ASTM D3359, ASTM D3002, DIN EN ISO 2409, DIN 53151 |
| Blade Spacing | 1.0 mm, 1.5 mm, 2.0 mm, or 3.0 mm |
| Number of Cutting Edges | 6 or 11 |
| Cutting Edge Count per Head | 6 or 1 |
| Accessories Included | Hex Key Wrench (for models 5123/5125/5126/5127/5128) |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Trident Film |
| Instrument Type | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | Better than 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | Better than 1% |
| Compliance | ISO 22007-2, ASTM D7984, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident HotDisk |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | Better than 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | Better than 1% |
| Standards Compliance | ISO 22007-2, ASTM D7984, ASTM D5334, ASTM D5930, GB/T 32064 |