Empowering Scientific Discovery

Ruyaa Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeDistributor
Origin CategoryImported
ModelAET Extension Tube
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelAccuSeries
PriceUpon Request
Measurement PrincipleIon-Selective Electrode (ISE)
Range0–10,000 ppb Na⁺
Accuracy±1% of Full Scale
Linearity±1% of Full Scale
Repeatability±1% of Full Scale
Response Time3–12 minutes
Operating Temperature−20 °C to +60 °C
Dimensions1016 mm × 406 mm × 241 mm
Weight45.3 kg
Power Supply10–32 VDC or 90–240 VAC
Power Consumption100 W
Analog OutputsUp to eight 4–20 mA isolated outputs
Communication ProtocolsModbus RTU (RS232/RS485), Modbus TCP/IP, USB, GUI direct PC connection
Relay OutputsConfigurable alarm and control relays
Sample PathwaysUp to six independent flow paths
Enclosure RatingIP65-rated corrosion-resistant cabinet (H₂S/Cl₂ resistant, moisture-proof)
System ArchitecturePhysically segregated electronics and fluidic modules
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeDistributor
Origin CategoryImported
ModelAPS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeDistributor
Origin CategoryImported
ModelASP Gas Measurement Probe
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMonitek Turbidimeter
ConfigurationOnline Process Turbidimeter
Measurement Range0–8000 mg/L (as SiO₂)
Resolution0.1 mg/L
Operating Ambient Temperature−10 °C to +50 °C
Accuracy±1 % of reading
Optical Principle12° forward scatter detection
Wavelength Range390–900 nm
Repeatability±1 %
Process ConnectionDN25–DN125 (½″–5″)
Max Process PressurePN16 / ANSI Class 150
Max Process Temperature140 °C
Sensor Housing Material316L stainless steel (Ti, Mn-Co alloy optional)
Window MaterialSapphire or metal-backed glass
Gasket OptionsFKM (FFKM, EPDM, silicone available)
Enclosure RatingIP65 / NEMA 4X
CleaningOptional integrated spray nozzle
SterilizationCIP-compatible
Hazardous Area CertificationATEX Zone 1 or Zone 2
Power Supply90–260 VAC, 50–60 Hz (24 VAC/DC optional)
Power Consumption≤50 VA
Analog OutputsUp to 4 × 4–20 mA (isolated)
Digital InterfaceRS-232C / RS-485 Modbus RTU (optional)
Relay Outputs4 programmable relays (48 V / 2 A)
Digital Inputs4 × 5 V (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
ModelAccuseries-LPA Online Analyzer
TypeOnline Analyzer
Measurement PrinciplePyrazolone-based Colorimetric Method
Detection Range0–1 ppm CN⁻
Communication Interfaces4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs
Sample HandlingUp to 6 Independent Flow Paths
Enclosure RatingCorrosion-Resistant Design (H₂S/Cl₂ Resistant, Humidity-Protected)
ComplianceDesigned for Continuous Emission Monitoring Systems (CEMS) and Industrial Wastewater Compliance Applications
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelRubotherm-DynTHERM
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelEyeTech Online Oil-in-Water Analyzer
PriceUpon Request
Measurement ParametersParticle Size & Shape
Concentration Range0–2000 ppm
Particle Size Range2–300 µm
Accuracy±4% or ±4 ppm
Sample Temperature2–120 °C
Sample PressureUp to 20 bar
Automation LevelFully Automatic
Cleaning SystemIntegrated Thermal Boosted Water Wash
Real-time OutputAlarm triggers on oil concentration threshold, particle size threshold, and wash pressure failure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelMonitek Nickel Ion Online Analyzer
Price RangeUSD 13,500 – 27,000
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Fluoride Ion Online Monitor
Instrument TypeFluoride Ion Analyzer
Measurement PrinciplePotentiometric Ion-Selective Electrode (ISE)
Range0–20 ppm
Accuracy±5% of reading or full scale
Resolution0.001 ppm
Repeatability±5% of reading or full scale
Cycle Time2 minutes
Sample Flow Rate50–900 mL/min
Sample Interface1/4" compression fitting
Sample Temperature5–70 °C
Max. Suspended Solids2% w/w, max. particle size 1.27 mm
Sample Pressure0–50 psig
Waste Outlet3/4" NPT male, open drain
Alarm OutputsUser-programmable digital outputs
Analog Output4–20 mA, fully configurable
Power Supply100–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
Dimensions (W×H×D)610 × 640 × 330 mm
Weight~36 kg (fully assembled)
MountingWall-mounted with included hardware
CertificationsCE-compliant, designed to meet general requirements for industrial environmental monitoring installations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
TypeIn-line Process Turbidimeter
ModelMoniTurb-F
Measurement Range0–500 NTU
Resolution±2% of full scale
Accuracy±0.5% of full scale
Operating Ambient Temperature−10 °C to +60 °C
Process Temperatureup to 140 °C
Process Pressureup to 220 psi (15 bar) at ambient temperature
Wetted Materials316L stainless steel (1.4404) standard, customizable
Optical Path Lengthpipe-diameter-dependent
Cable Lengthup to 100 m
Enclosure RatingNEMA 4X / IP66
Hazardous Area OptionsClass I, Div. 1
Output InterfaceCompatible with Monitek® Messenger transmitter
Detection Principle12° forward scatter photometry
Optional ConfigurationsMoniTurb-S (90° side scatter), MoniTurb-FS (dual-angle scatter)
Calibration Interval12 months
Color CompensationYes
Optional Air/Water Jet Cleaning SystemAvailable
Process ConnectionsDIN, ANSI, SMS, NPT, APV, TH, Tri-Clamp
Units SupportedNTU, JTU, AU, EBC, ppm, g/L, % concentration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
ModelAccuseries LPA Online Analyzer
Instrument TypeOnline Chloride Analyzer
Measurement Range0–50 ppm
Detection Limit0.1 ppm
Response Time8 min
Accuracy±1% of reading
Operating Temperature Range−20 °C to +60 °C
Communication Interfaces4–20 mA, Modbus TCP/IP, RS232, RS458, USB, GUI PC Direct Connection, Relay Outputs
Sample StreamsUp to 6 independent flow paths
Analytical MethodPotentiometric Titration
Enclosure RatingIP65 (corrosion-resistant, H₂S/Cl₂ tolerant, moisture-proof)
Service LifeDesigned for continuous 24/7 operation with automated reagent management
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Chromium Ion Online Monitor
PriceUpon Request
Instrument TypeMulti-Ion Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRuboLab
OriginSwitzerland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDASH
Hydrogen Generation PrincipleRare-Earth Alloy-Based Reversible Hydride Absorption/Desorption
Output Flow Rate150 L/min (STP)
Output Pressure Range0–20 MPa
Hydrogen Purity99.9999% (v/v)
Power ConsumptionApplication-Dependent — Typically <1 kW for thermal management during desorption cycles
ComplianceCE, PED 2014/68/EU, ASME BPVC Section VIII Div. 2 (design basis), ISO 16111:2017 (Hydrogen Technologies – Gaseous Hydrogen Storage)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRuboLab
OriginGermany
ModelRuboHyCo
Hydrogen Generation PrincipleMetal Hydride-Based Thermal Desorption
Output Flow Rate800 mL/min (per compression station)
Output Pressure20 MPa (2,900 psi) or 70 MPa (10,000 psi)
Hydrogen Purity99.9999%
Power ConsumptionNot specified (device is thermally actuated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMetorex C100
Detection PrincipleEnergy-Dispersive X-ray Fluorescence (EDXRF)
PortabilityFixed-Installation
AnalyteTotal Sulfur
Measurement Range0.5 ppm to 10 wt%
Analysis ModeReal-Time Continuous Monitoring
Detection Limit0.5 ppm (S, in liquid hydrocarbons)
AccuracyCompliant with ASTM D4294 and ASTM D7212
Regulatory ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Chromium Ion Online Monitor
PriceUpon Request
Instrument TypeMulti-Ion Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRuboLab
OriginGermany
ModelRuboSORP 50 / 150 / 350 / 700
Measurement PrincipleMagnetic Suspension Balance (Gravimetric)
Temperature Range−196 °C to 500 °C
Pressure Range0–700 bar
Ultimate Vacuum1 × 10⁻⁷ mbar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGalvanic
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMonitek Zinc Ion Online Analyzer
Price RangeUSD 14,000 – 28,000
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelRH-200 Relative Humidity Generator
PriceUpon Request
RH Range3–95% RH
RH Control Accuracy±1.0% RH
Temperature Control RangeAmbient to 50 °C
Dew Point Range−25 °C to 50 °C
Standard Flow Rate500 mL/min (Optional High-Flow: up to 5 L/min)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentinel Hydrochloric Acid Concentration Analyzer
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOtO
OriginTaiwan
ModelSW2860-050
Wavelength Range900–1700 nm
Detector256-pixel InGaAs linear array
CoolingThermoelectric (TE)
Usage Duration2 years
Warranty≥3 years
ConditionRefurbished, Fully Tested
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSentine Phosphate Online Monitor
Instrument TypePhosphate (Orthophosphate) Analyzer
Accuracy±2% of reading or full scale
Resolution0.001 mg/L
Repeatability±2% of reading or full scale
Measurement Cycle5 minutes
Sample Flow Rate50–900 mL/min
Sample Interface1/4" compression fitting
Sample Temperature Range5–70 °C
Max. Suspended Solids2% w/w, max. particle size 1.27 mm
Sample Pressure Range0–345 kPa (0–50 psig)
Drain Outlet3/4" NPT male, atmospheric discharge
Alarm OutputsUser-programmable digital outputs
Analog Output4–20 mA, fully configurable
Power Supply100–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
MountingWall-mounted with included hardware
Dimensions (W×H×D)387 × 406 × 210 mm
Weight~36 kg (fully configured)
CertificationsCE compliant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRubolab
ModelSmart Filtration Kit
OriginSpain
Instrument TypeOnline Monitoring System
Measured ParametersFoam Characteristics, Particle Count (ISO/NAS Code), Demulsibility Indicator (via OilWear Sensor Platform), Optional Water Content (ppm)
Flow ControlIntegrated Flow Meter & Regulator
ComplianceISO 4406, ISO 11171, ASTM D892, ASTM D2711, ISO 6247
SoftwareRubolab OilWear™ Cloud Platform with Audit Trail & Exportable CSV/Excel Reports
CertificationsCE, RoHS, Designed for GLP/GMP Environments
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0