| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AET Extension Tube |
| Pricing | Upon Request |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Range | 0–10,000 ppb Na⁺ |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 3–12 minutes |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 100 W |
| Analog Outputs | Up to eight 4–20 mA isolated outputs |
| Communication Protocols | Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, GUI direct PC connection |
| Relay Outputs | Configurable alarm and control relays |
| Sample Pathways | Up to six independent flow paths |
| Enclosure Rating | IP65-rated corrosion-resistant cabinet (H₂S/Cl₂ resistant, moisture-proof) |
| System Architecture | Physically segregated electronics and fluidic modules |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | APS |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ASP Gas Measurement Probe |
| Pricing | Upon Request |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Monitek Turbidimeter |
| Configuration | Online Process Turbidimeter |
| Measurement Range | 0–8000 mg/L (as SiO₂) |
| Resolution | 0.1 mg/L |
| Operating Ambient Temperature | −10 °C to +50 °C |
| Accuracy | ±1 % of reading |
| Optical Principle | 12° forward scatter detection |
| Wavelength Range | 390–900 nm |
| Repeatability | ±1 % |
| Process Connection | DN25–DN125 (½″–5″) |
| Max Process Pressure | PN16 / ANSI Class 150 |
| Max Process Temperature | 140 °C |
| Sensor Housing Material | 316L stainless steel (Ti, Mn-Co alloy optional) |
| Window Material | Sapphire or metal-backed glass |
| Gasket Options | FKM (FFKM, EPDM, silicone available) |
| Enclosure Rating | IP65 / NEMA 4X |
| Cleaning | Optional integrated spray nozzle |
| Sterilization | CIP-compatible |
| Hazardous Area Certification | ATEX Zone 1 or Zone 2 |
| Power Supply | 90–260 VAC, 50–60 Hz (24 VAC/DC optional) |
| Power Consumption | ≤50 VA |
| Analog Outputs | Up to 4 × 4–20 mA (isolated) |
| Digital Interface | RS-232C / RS-485 Modbus RTU (optional) |
| Relay Outputs | 4 programmable relays (48 V / 2 A) |
| Digital Inputs | 4 × 5 V (optional) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries-LPA Online Analyzer |
| Type | Online Analyzer |
| Measurement Principle | Pyrazolone-based Colorimetric Method |
| Detection Range | 0–1 ppm CN⁻ |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Handling | Up to 6 Independent Flow Paths |
| Enclosure Rating | Corrosion-Resistant Design (H₂S/Cl₂ Resistant, Humidity-Protected) |
| Compliance | Designed for Continuous Emission Monitoring Systems (CEMS) and Industrial Wastewater Compliance Applications |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rubotherm-DynTHERM |
| Price | Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EyeTech Online Oil-in-Water Analyzer |
| Price | Upon Request |
| Measurement Parameters | Particle Size & Shape |
| Concentration Range | 0–2000 ppm |
| Particle Size Range | 2–300 µm |
| Accuracy | ±4% or ±4 ppm |
| Sample Temperature | 2–120 °C |
| Sample Pressure | Up to 20 bar |
| Automation Level | Fully Automatic |
| Cleaning System | Integrated Thermal Boosted Water Wash |
| Real-time Output | Alarm triggers on oil concentration threshold, particle size threshold, and wash pressure failure |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Monitek Nickel Ion Online Analyzer |
| Price Range | USD 13,500 – 27,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Fluoride Ion Online Monitor |
| Instrument Type | Fluoride Ion Analyzer |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) |
| Range | 0–20 ppm |
| Accuracy | ±5% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±5% of reading or full scale |
| Cycle Time | 2 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Max. Suspended Solids | 2% w/w, max. particle size 1.27 mm |
| Sample Pressure | 0–50 psig |
| Waste Outlet | 3/4" NPT male, open drain |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Dimensions (W×H×D) | 610 × 640 × 330 mm |
| Weight | ~36 kg (fully assembled) |
| Mounting | Wall-mounted with included hardware |
| Certifications | CE-compliant, designed to meet general requirements for industrial environmental monitoring installations |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Type | In-line Process Turbidimeter |
| Model | MoniTurb-F |
| Measurement Range | 0–500 NTU |
| Resolution | ±2% of full scale |
| Accuracy | ±0.5% of full scale |
| Operating Ambient Temperature | −10 °C to +60 °C |
| Process Temperature | up to 140 °C |
| Process Pressure | up to 220 psi (15 bar) at ambient temperature |
| Wetted Materials | 316L stainless steel (1.4404) standard, customizable |
| Optical Path Length | pipe-diameter-dependent |
| Cable Length | up to 100 m |
| Enclosure Rating | NEMA 4X / IP66 |
| Hazardous Area Options | Class I, Div. 1 |
| Output Interface | Compatible with Monitek® Messenger transmitter |
| Detection Principle | 12° forward scatter photometry |
| Optional Configurations | MoniTurb-S (90° side scatter), MoniTurb-FS (dual-angle scatter) |
| Calibration Interval | 12 months |
| Color Compensation | Yes |
| Optional Air/Water Jet Cleaning System | Available |
| Process Connections | DIN, ANSI, SMS, NPT, APV, TH, Tri-Clamp |
| Units Supported | NTU, JTU, AU, EBC, ppm, g/L, % concentration |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries LPA Online Analyzer |
| Instrument Type | Online Chloride Analyzer |
| Measurement Range | 0–50 ppm |
| Detection Limit | 0.1 ppm |
| Response Time | 8 min |
| Accuracy | ±1% of reading |
| Operating Temperature Range | −20 °C to +60 °C |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS458, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Streams | Up to 6 independent flow paths |
| Analytical Method | Potentiometric Titration |
| Enclosure Rating | IP65 (corrosion-resistant, H₂S/Cl₂ tolerant, moisture-proof) |
| Service Life | Designed for continuous 24/7 operation with automated reagent management |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Chromium Ion Online Monitor |
| Price | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Brand | RuboLab |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DASH |
| Hydrogen Generation Principle | Rare-Earth Alloy-Based Reversible Hydride Absorption/Desorption |
| Output Flow Rate | 150 L/min (STP) |
| Output Pressure Range | 0–20 MPa |
| Hydrogen Purity | 99.9999% (v/v) |
| Power Consumption | Application-Dependent — Typically <1 kW for thermal management during desorption cycles |
| Compliance | CE, PED 2014/68/EU, ASME BPVC Section VIII Div. 2 (design basis), ISO 16111:2017 (Hydrogen Technologies – Gaseous Hydrogen Storage) |
| Brand | RuboLab |
|---|---|
| Origin | Germany |
| Model | RuboHyCo |
| Hydrogen Generation Principle | Metal Hydride-Based Thermal Desorption |
| Output Flow Rate | 800 mL/min (per compression station) |
| Output Pressure | 20 MPa (2,900 psi) or 70 MPa (10,000 psi) |
| Hydrogen Purity | 99.9999% |
| Power Consumption | Not specified (device is thermally actuated |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Metorex C100 |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Portability | Fixed-Installation |
| Analyte | Total Sulfur |
| Measurement Range | 0.5 ppm to 10 wt% |
| Analysis Mode | Real-Time Continuous Monitoring |
| Detection Limit | 0.5 ppm (S, in liquid hydrocarbons) |
| Accuracy | Compliant with ASTM D4294 and ASTM D7212 |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Chromium Ion Online Monitor |
| Price | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Brand | RuboLab |
|---|---|
| Origin | Germany |
| Model | RuboSORP 50 / 150 / 350 / 700 |
| Measurement Principle | Magnetic Suspension Balance (Gravimetric) |
| Temperature Range | −196 °C to 500 °C |
| Pressure Range | 0–700 bar |
| Ultimate Vacuum | 1 × 10⁻⁷ mbar |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Monitek Zinc Ion Online Analyzer |
| Price Range | USD 14,000 – 28,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RH-200 Relative Humidity Generator |
| Price | Upon Request |
| RH Range | 3–95% RH |
| RH Control Accuracy | ±1.0% RH |
| Temperature Control Range | Ambient to 50 °C |
| Dew Point Range | −25 °C to 50 °C |
| Standard Flow Rate | 500 mL/min (Optional High-Flow: up to 5 L/min) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Hydrochloric Acid Concentration Analyzer |
| Price | Upon Request |
| Brand | OtO |
|---|---|
| Origin | Taiwan |
| Model | SW2860-050 |
| Wavelength Range | 900–1700 nm |
| Detector | 256-pixel InGaAs linear array |
| Cooling | Thermoelectric (TE) |
| Usage Duration | 2 years |
| Warranty | ≥3 years |
| Condition | Refurbished, Fully Tested |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentine Phosphate Online Monitor |
| Instrument Type | Phosphate (Orthophosphate) Analyzer |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 mg/L |
| Repeatability | ±2% of reading or full scale |
| Measurement Cycle | 5 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature Range | 5–70 °C |
| Max. Suspended Solids | 2% w/w, max. particle size 1.27 mm |
| Sample Pressure Range | 0–345 kPa (0–50 psig) |
| Drain Outlet | 3/4" NPT male, atmospheric discharge |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully configured) |
| Certifications | CE compliant |
| Brand | Rubolab |
|---|---|
| Model | Smart Filtration Kit |
| Origin | Spain |
| Instrument Type | Online Monitoring System |
| Measured Parameters | Foam Characteristics, Particle Count (ISO/NAS Code), Demulsibility Indicator (via OilWear Sensor Platform), Optional Water Content (ppm) |
| Flow Control | Integrated Flow Meter & Regulator |
| Compliance | ISO 4406, ISO 11171, ASTM D892, ASTM D2711, ISO 6247 |
| Software | Rubolab OilWear™ Cloud Platform with Audit Trail & Exportable CSV/Excel Reports |
| Certifications | CE, RoHS, Designed for GLP/GMP Environments |
Show next