| Brand | OPUS/OPSIS |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DI-110 |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Reagent Reservoir Capacity | 2 L |
| Construction Materials | Borosilicate Glass Condenser & Vessel, Fluoroelastomer (FKM) Tubing |
| Vacuum Source | Integrated Acid-Resistant Negative-Pressure Pump |
| Footprint | Compact Design for Benchtop Integration Adjacent to Digestion Units |
| Control Interface | 6-Step Programmable Suction Profile |
| Compliance | Designed for ASTM D3682, ISO 11733, and EPA Method 3050B-Compatible Sample Prep Environments |
| Brand | OPSS/OPSIS |
|---|---|
| Origin | Sweden |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DI-210 |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Semi-Automatic |
| Digestion Positions | 10 |
| Max Heating Temperature | 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Principle | Resistive Electric Heating |
| Reagent Channels | 10 |
| Sample Capacity | Up to 15 mL liquid or 5 g solid per tube |
| Programmable Step Duration | 0–999 min per stage |
| Continuous Operation | 24 h |
| Interface | RS232 and USB |
| Display | LCD with real-time temperature & timer |
| Safety Features | Over-Temperature Protection with Audible Alarm |
| Cooling Mode | Auto-cooling post-digestion |
| Temperature Sensor | Self-Calibrating Electronic Sensor |
| Language Options | Multi-Language UI (English, German, French, Spanish, Chinese) |
| Upgradeability | Hardware and firmware upgradable |
| Brand | OPSEUS/OPSIS |
|---|---|
| Country of Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | 200 Series |
| Instrument Type | Electric Heating Digestion Instrument |
| Automation Level | Fully Automatic |
| Digestion Positions | 10 |
| Maximum Heating Temperature | 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Principle | Electrical Resistive Heating |
| Reagent Channels | 1 |
| Brand | OPSEUS/OPSIS |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DI-220 |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 20 |
| Max. Heating Temperature | 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Principle | Resistive Electric Heating |
| Reagent Channels | 20 |
| Brand | OPSEUS/OPSIS |
|---|---|
| Origin | Sweden |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DI-310 |
| Instrument Type | Electric Block Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 20 |
| Temperature Range | Ambient to 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Principle | Electric Resistive Heating |
| Reagent Channels | 20 |
| Power Supply | 220 V / 50 Hz, 1200 W |
| Max. Overtemperature Protection | 500 °C (alarm + auto-hold) |
| Programmable Ramp Profiles | Yes |
| Digestion Time Range | 1–999 min |
| Integrated Lift Mechanism | Motorized Sample Rack Elevation/Depression |
| Sensor Diagnostics | Auto-detection, calibration status monitoring, and fault alerting |
| Compliance Standards | AOAC, EPA, DIN, ISO |
| Brand | OPSS/OPSIS |
|---|---|
| Origin | Sweden |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DI-320 |
| Pricing | Upon Request |
| Digestion Capacity | 20 samples per batch |
| Digestion Time | <60 min |
| Temperature Range | Ambient to 450 °C (digital display) |
| Temperature Control Accuracy | ±0.5 °C |
| Over-Temperature Protection | 500 °C with audible/visual alert |
| Heating Duration Setting | 1–999 min |
| Power Supply | 220 V / 50 Hz, 2200 W |
| Compliance | AOAC, EPA, DIN, ISO |
| Brand | OPSEUS/OPSIS |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DI-320 |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 20 |
| Max. Heating Temperature | 450 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Principle | Resistive Electric Heating |
| Reagent Channels | 20 |
| Brand | PARR |
|---|---|
| Model | Parr Acid Digestion Bomb |
| Construction | Stainless Steel Body with PTFE (Teflon) Liner |
| Max Operating Temperature | 250 °C |
| Max Operating Pressure | 1800–5000 psig |
| Sample Volume Capacity | 23–125 mL |
| Application | Closed-Vessel Acid Digestion for Trace Element Analysis |
| Compliance | Designed for ASTM D5174, EPA Method 3050B/3051A/3052, ISO 11466, and USP <231> sample preparation workflows |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Vessel Capacity | 100 mL |
| Material Options | PTFE (Standard), Optional Upgraded PTFE (Microwave-Grade) |
| Compliance | Designed for Compatibility with Parr Instrument Company Standard 4740/4742/4744 Series Internal Vessels |
| Safety Design | Dual-Chamber Pressure Relief Architecture with Controlled Deformation Zone |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Microwave Digestion Vessel |
| Pricing | Upon Request |
| Max Operating Temperature | 250 °C |
| Max Operating Pressure | 1200 psig |
| Sample Volume Capacity | 23–45 mL |
| Construction | Reinforced High-Performance Polymer Outer Sleeve with PTFE Liner |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-08S |
| Pricing | Upon Request |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-08S2 |
| Heating Element Type | Opal White Quartz Tube with Embedded Resistive Heating Alloy |
| Radiation Spectrum | Predominantly Far-Infrared (λ = 3–10 µm) |
| Max Operating Temperature | 550 °C (Continuous), 600 °C (Short-Term) |
| Temperature Control Accuracy | ±2 °C |
| Ramp Rate | Programmable, 0.1–20 °C/min |
| Sample Capacity | 8 × 16 mm or 8 × 20 mm Digestion Tubes |
| Power Supply | 220 V AC, 50/60 Hz |
| Safety Compliance | IEC 61010-1, GB/T 12804-2022 |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-08S2 |
| Heating Method | Quartz Infrared Tubular Heater |
| Number of Digestion Ports | 8 |
| Temperature Range | Ambient to 550 °C |
| Temperature Stability | ±1% of setpoint |
| Ramp Time | ≤10 min to 400 °C (preheating) |
| Power Supply | AC 220 V |
| Rated Power | 1600 W |
| External Dimensions (W×D×H) | 655 × 320 × 210 mm |
| Digestion Tube Dimensions | Ø42 × 300 mm |
| Safety Features | Dual independent switches (power & heating), over-current protection, earth-leakage circuit breaker, stainless-steel fume hood with integrated SO₂ scrubbing duct |
| Control System | Microcontroller-based digital PID temperature controller |
| Compliance | CE-marked heating module |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-08S3 |
| Pricing | Available Upon Request |
| Control Interface | LCD Display with Timer + Multi-Stage Programmable Ramp |
| Heating Method | Infrared Radiation via Quartz Tube |
| Number of Digestion Ports | 8 |
| Temperature Range | Ambient to 680 °C |
| Preheating Time to 400 °C | ≤15 min |
| Temperature Stability | ±1 °C |
| Insulation | Dual-Layer (Ceramic Fiber + Air Gap) |
| Input Voltage | AC 220 V |
| Rated Power | 1.6 kW |
| Digestion Tube Dimensions & Material | 300 mm × 42 mm OD, High-Purity Fused Quartz |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-08S3 |
| Heating Method | Infrared radiation via opal white quartz tubes |
| Number of Digestion Ports | 8 |
| Temperature Range | Ambient to 550 °C |
| Temperature Stability | ±1 °C |
| Ramp Time | 15 min to 400 °C (preheat) |
| Control Interface | LCD display with n-step programmable ramping and timer |
| Insulation | Dual-layer (ceramic fiber + air gap) |
| Power Supply | AC 220 V |
| Rated Power | 1.6 kW |
| Safety Features | Dual independent switches (power & heating), over-current protection, earth leakage protection, integrated explosion-proof cap, corrosion-resistant stainless steel fume hood with lift mechanism and acid-resistant tray |
| Compliance | CE-marked |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-18S2 |
| Pricing | Available Upon Request |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-18S2 |
| Heating Method | Infrared radiation via quartz tubes |
| Number of Digestion Ports | 18 |
| Temperature Range | Ambient to 680 °C |
| Temperature Stability | ±1 °C |
| Ramp Time to 400 °C | 15 min |
| Dual Insulation | Ceramic fiber (silica-alumina) + air gap |
| Power Supply | AC 220 V |
| Rated Power | 1600 W |
| Digestion Tube Dimensions | Ø25 mm × 300 mm |
| Control System | Digital PID with 64-step programmable ramping and timer |
| Safety Features | Over-temperature, over-current, and over-pressure protection |
| Exhaust System | Stainless steel fume duct with integrated SO₂ absorption path |
| Optional Accessories | 5000-program touchscreen controller, SF-100 acid gas neutralization system, explosion-proof sample covers |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-20S2 |
| Control System | Microcontroller-based (64-step programmable ramp + timer) |
| Heating Method | Far-infrared radiation from opal milky quartz tubes |
| Number of Digestion Ports | 20 |
| Temperature Range | Ambient to 550 °C |
| Ramp Time | 20 min (ambient to 400 °C) |
| Temperature Stability | ±1 °C |
| Voltage | AC 220 V |
| Power Consumption | 1950 W |
| Dimensions (L×W×H) | 655 × 340 × 210 mm |
| Digestion Tube Compatibility | Ø42 × 300 mm |
| Safety Features | Dual independent switches (power & heating), over-current protection, earth-leakage circuit breaker, stainless steel fume hood with SO₂ scrubbing duct |
| Optional Accessory | Sample explosion guard |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-20S3 |
| Heating Method | Infrared radiation via quartz tubes |
| Number of Digestion Ports | 20 |
| Temperature Range | Ambient to 680 °C |
| Temperature Stability | ±1 °C |
| Programmable Control | LCD display with timer and multi-stage ramp/soak programming |
| Ramp Time | ≤20 min to 400 °C |
| Insulation | Dual-layer (ceramic fiber + air gap) |
| Voltage | AC 220 V |
| Power Rating | 1.95 kW |
| Digestion Tube Dimensions | Ø30 × 42 mm (quartz) |
| Safety Features | Overcurrent protection, earth leakage protection, dual independent power switches (main power + heating module), integrated stainless-steel fume hood with exhaust port for SO₂ and acid vapors |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-20S3 |
| Heating Method | Far-infrared quartz radiation |
| Number of Digestion Ports | 20 |
| Temperature Range | Ambient to 550 °C |
| Temperature Stability | ±1 °C |
| Programmable Control | LCD-based, multi-step ramping (timer + n-segment program) |
| Power Supply | AC 220 V |
| Rated Power | 1950 W |
| Thermal Insulation | Dual-layer (ceramic fiber + air gap) |
| Safety Features | Over-current protection, earth-leakage circuit breaker, integrated explosion-proof vent, corrosion-resistant stainless steel fume hood with lift mechanism and acid-resistant tray |
| Compliance | CE-marked |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-20T |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 20 |
| Max Heating Temperature | 680 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Principle | Infrared Radiation via Quartz Heaters |
| Programmable Temperature Stages | ≥64 |
| Safety Features | Overcurrent Protection, Earth Leakage Protection, Dual Independent Power/Heating Switches |
| Control System | PID-Based Digital Temperature Controller |
| Sample Vessel Material | PTFE (Polytetrafluoroethylene) Digestion Tubes |
| Compliance | CE Certified |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-48S2 |
| Number of Digestion Positions | 48 |
| Temperature Range | Ambient to 680 °C |
| Heating Rate | 22 min (to 400 °C, empty chamber) |
| Temperature Uniformity | ±1 °C |
| Voltage | AC 220 V |
| Power Rating | 1950 W |
| Digestion Tube Dimensions | 25 mm × 300 mm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MPS 320™ |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Titan MPS |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 16 × 75 mL vessels or 8 × 100 mL vessels |
| Max Temperature | 260 °C |
| Max Pressure | 100 bar |
| Pressure & Temperature Monitoring | Direct Optical Pressure Control™ (DPC) and Direct Optical Temperature Control™ (DTC) per vessel |
| Vessel Material | TFM™ fluoropolymer |
| Cavity Lining | PFA-coated cylindrical stainless steel |
| Gas Management | Integrated acid-resistant fume capture and continuous cavity venting |
| Software Platform | Linux-based embedded GUI with network-enabled remote access (no client software required) |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | PIE |
|---|---|
| Origin | USA |
| Model | EM-KLEEN |
| RF Frequency | 13.56 MHz |
| RF Power | 75 W |
| Control | Fully Automated |
| Gas Configuration | Single- or Triple-Gas Mixing System (O₂, H₂, Ar, N₂, CF₄, NF₃, NH₃, HF, H₂S) |
| Plasma Type | Remote Inductively Coupled Plasma (ICP), Non-Microwave, Non-Underfill, Non-Wafer-Specific |
| Chamber Compatibility | Direct integration with SEM, FIB-SEM, TEM, XPS, ALD, CD-SEM, EBR, EBI, EUVL, and other UHV/XHV systems |
| Sample & Chamber Cleaning | Simultaneous in-situ cleaning of both specimen surface and vacuum chamber interior |
| Plasma Intensity Monitoring | Integrated real-time plasma emission sensor |
| Flow Control | Pressure-feedback-based automated mass flow control (no manual needle valve) |
| User Interface | Capacitive touchscreen with 60 programmable cleaning protocols |
| Safety Modes | Dual-mode operation (Smart Safety Mode + Expert Control Mode) |
| Scheduling | SmartSchedule™ logic triggered by chamber venting cycles, sample load count, or time-based intervals |
| Electromagnetic Compatibility | Low-EMI architecture |
| Optional Upgrades | Sapphire plasma tube assembly |
| Brand | PIE Scientific |
|---|---|
| Origin | USA |
| Model | Tergeo Basic |
| RF Frequency | 13.56 MHz |
| RF Power | 75 W (optional 150 W) |
| Chamber Internal Diameter × Depth | 110 mm × 280 mm |
| Chamber Volume | 2.6 L |
| Chamber Material | High-Purity Fused Quartz |
| Gas Inlets | 2 standard, optional 3rd |
| Control Interface | 7-inch full-color touchscreen, fully automated |
| Plasma Type | Capacitively Coupled RF Plasma (CCP), non-microwave, non-underfill, non-wafer-specific |
| Compliance | CE, RoHS, FCC Class A |
| Brand | PIE Scientific |
|---|---|
| Model | Tergeo EM |
| Origin | USA |
| RF Frequency | 13.56 MHz |
| RF Power | 75 W (optional 150 W) |
| Chamber Dimensions | Ø110 mm × Depth 280 mm |
| Chamber Volume | 2.6 L |
| Chamber Material | High-Purity Fused Quartz |
| Gas Inlets | 2 standard, optional 3rd inlet |
| Control Interface | 7-inch full-color touchscreen, fully automated |
| Plasma Type | Capacitively Coupled RF Plasma (CCP), no microwave, no downstream-only, no wafer-specific configuration |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | PIE Scientific |
|---|---|
| Origin | USA |
| Model | SEMI-KLEEN |
| RF Frequency | 13.56 MHz |
| RF Power Output | 0–100 W (continuously adjustable) |
| Max Input Power | 200 W |
| Vacuum Interface | KF40 (NW40) flange |
| Ignition Pressure | <0.1 mTorr |
| Operating Pressure Range | <0.1 mTorr to >1.0 Torr |
| Leak Rate | <0.005 sccm |
| Gas | Ambient air (no external gas supply required) |
| Control | Microprocessor-based touchscreen interface with programmable cleaning protocols |
| Plasma Monitoring | Integrated real-time plasma intensity sensor |
| Automatic RF Matching | Yes |
| Particle Filtration | Dual-stage proprietary particulate filter compliant with semiconductor-grade cleanliness requirements |
| Compliance | Designed for GLP/GMP-adjacent vacuum system maintenance |
| [Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Model | PDC-36G |
| Input Voltage | 110/220 V, 50/60 Hz |
| Power Consumption | <100 W |
| RF Output Frequency | 13.56 MHz |
| DC Bias Settings | Low (680 V / 10 mA / 6.8 W), Medium (700 V / 15 mA / 10.5 W), High (720 V / 25 mA / 18 W) |
| Chamber Dimensions | Ø75 mm × 165 mm (borosilicate glass) |
| Vacuum Requirement | ≥160 L/min pumping speed, ultimate pressure ≤200 mtorr (0.27 mbar) |
| Gas Compatibility | Air, O₂, Ar, N₂, or mixed non-flammable gases |
| External Vacuum Gauge Option | Pirani-based resistive gauge (range: atmospheric to 0.1 Pa, non-corrosive gases only) |
| Dimensions (W×D×H) | 200 × 250 × 210 mm |
| Net Weight (excl. pump) | 8 kg |
| Warranty | 12 months standard, lifetime technical support] |
| Brand | Europlasma |
|---|---|
| Origin | Belgium |
| Model | CD1836 |
| RF Power | 5 kW |
| Chamber Dimensions | 1600 × 1350 × 850 mm |
| Chamber Volume | 1836 L |
| Chamber Material | Anodized Aluminum |
| Process Gases | O₂, Ar, and other non-halogenated process gases |
| Control System | Fully Automated PLC-Based Interface |
| Vacuum System | Dry Scroll Pump with Pirani Gauge |
| Electrical Supply | 380 V AC, 3-Phase, 50 Hz, 63 A |
| Certifications | CE Compliant |
| Safety Features | Emergency Stop, Vacuum Interlock, Thermal Overload Protection |