Sample Prep/Digestion Equipment
Filter
Showing 811–840 of 1206 results
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qcut 800 A |
| Cutting Wheel Diameter | Up to 800 mm (32") |
| Max. Sample Diameter | 295 mm |
| Max. Sample Dimensions (W×H×D) | 1100 × 450 × 800 mm |
| Max. Cutting Distance | 225 mm (with 600 mm wheel) |
| Flange Size | Ø32/40 mm |
| Auto X-Axis Travel | 700 mm |
| Auto Y-Axis Travel | 450 mm |
| Auto Z-Axis Travel | 700 mm |
| Z-Axis Positioning Accuracy | 0.1 mm |
| Table Size (W×D) | 1150 × 800 mm |
| T-Slot Width | 12 mm |
| Spindle Speed Range | 1000–2000 rpm |
| Motor Power | 30 kW (S1 continuous duty) |
| Supply Requirement | 50 kVA, 3-phase |
| Machine Dimensions (W×H×D) | 2200 × 2175 × 1840 mm |
| Weight | ~3500 kg |
| Cooling | Integrated Closed-Loop Water Circulation System |
| Lubrication | Centralized Automatic Pneumatic Lubrication (6 bar required) |
| Control Interface | Touchscreen HMI with QATM Software Suite |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | QETCH 1000 |
| Dimensions (L×W×D) | 330 × 220 × 400 mm |
| Weight | ~7 kg |
| Power Supply | 2 kVA |
| Max. Output Voltage | 90 V DC |
| Max. Current | 14 A |
| Polishing Time Range | 1 s – 25 min |
| Etching Time Range | 1 s – 5 min |
| Electrolyte Volume | 1 L (sealed, exchangeable cell) |
| Control Interface | Touchscreen with QATM proprietary software |
| Programmable Methods | Up to 200 user-defined protocols with password protection |
| Real-time Display | Simultaneous current & voltage monitoring |
| Compliance | Designed for fume hood integration |
| Cleaning | Automated water-based rinse cycle |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | QETCH 100M |
| Dimensions (L×W×D) | 380 × 355 × 180 mm |
| Max. Power | 160 W |
| Max. Voltage | 90 V DC |
| Max. Current | 2 A |
| Electrolyte Capacity | 1 L |
| Weight | ~8.5 kg (without electrolyte) |
| Operating Mode | Microprocessor-Controlled Automatic Cycle |
| Display | Color LED + LCD (showing real-time voltage, current, elapsed time) |
| Polishing Area | Ø ~9 mm |
| Power Source | Rechargeable Lithium-Ion Battery |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | QGRIND 100 |
| Belt Speed | 7 m/s |
| Belt Dimensions | 100 × 920 mm / 100 × 915 mm |
| Number of Grinding Belts | 2 |
| Overall Dimensions (L×W×D) | 630 × 250 × 520 mm |
| Weight | ~55 kg |
| Power Supply | 1.4 kVA (0.75 kW, S6/60% duty cycle) |
| Water Inlet | R½", max. 6 bar |
| Water Outlets | dual Ø40 mm (left & right) |
| Cooling | integrated water-cooled wet grinding system |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | QGRIND XL |
| Speed Range | 1000–2000 rpm (grinding wheel) / 30–160 rpm (specimen holder) |
| Grinding Wheel Diameter | up to 356 mm |
| Specimen Holder Diameter | 160–204 mm |
| Applied Force Range | 50–750 N (center-loaded, electronically controlled) |
| Material Removal Resolution | ±0.1 mm (display), 0.1–10 mm total removal range |
| Grinding Wheel Motor Power | 4 kW (S1 duty) |
| Specimen Holder Motor Power | 0.75 kW (S1 duty) |
| Electrical Supply | 400 V / 50 Hz (3Ph/N/PE), 480 V / 60 Hz (3Ph/N/PE), or 220 V / 60 Hz (3Ph/N/PE) |
| Total Power Requirement | 9 kVA |
| Dimensions (L×W×H) | 1055 × 860 × 1623 mm |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qmount |
| Type | UV Curing Hot Mounting Press |
| Max Sample Support Area | 200 × 260 mm |
| Max Sample Height | 40 mm |
| UV Wavelength | 365 nm |
| Adjustable Curing Time | 0–100 min |
| Polymerization Temperature Range | 70–90 °C |
| Input Voltage | 100–240 V, 50/60 Hz, 1Ph/N/PE |
| Dimensions (W×H×D) | 377 × 172 × 436 mm |
| Weight | 14.5 kg |
| LED Lifetime | >20,000 h |
| Safety | Optional Vacuum Extraction Interface Compatible |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpol 200 M |
| Disc Diameter | Ø 200 mm |
| Disc Quantity | 1 |
| Speed Range | 20–600 rpm (continuously adjustable) |
| Dimensions (L×W×D) | 401 × 286 × 603 mm |
| Weight | ~20–25 kg |
| Power Supply | 200–240 V / 50/60 Hz (1Ph/N/PE) or 100–120 V / 50/60 Hz (1Ph/N/PE) |
| Rated Power | 0.7 kVA |
| Optional Accessory | Qdoser ONE automated dispensing system |
| Brand | QATM (formerly ATM) |
|---|---|
| Origin | Germany |
| Model | Qpol 250 BOT (SAPHIR X-Change) |
| Dimensions (L×W×D) | 1320 × 1500 × 800 mm |
| Grinding/Polishing Disc Count | 1 |
| Disc Diameter | 250 mm |
| Disc Speed | 50–600 rpm |
| Control Head Speed | 30–150 rpm |
| Material Removal Control Resolution | 0.1 mm |
| Input Water Pressure | ≤6 bar |
| Drain Outlet | DN50 |
| Compressed Air Supply | 6 bar, NG8 coupling |
| Rated Power (Main Drive) | 1.1 kW (S3/40%) |
| Control Head Motor Power | 0.17 kW (S1) |
| Clamp Max. Diameter | 160 mm |
| Sediment Tank Capacity | 45 L |
| Safety Features | Light Curtain, Semi-Enclosed Work Area with Shielding Panel |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpol 250 M1 |
| Speed Range | 30–600 rpm, continuously adjustable |
| Platen Diameter | Ø 200 / 250 mm |
| Number of Platens | 1 |
| Dimensions (L×W×D) | 511 × 265 × 710 mm |
| Power Supply | 1.0 kVA |
| Rated Output (S1 duty) | 0.55 kW |
| Weight | ~25–30 kg |
| Water Inlet | R½", max. 6 bar |
| Optional Dosing System | Qdoser GO or Qdoser ONE |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpol 250 M2 |
| Speed Range | 30–600 rpm, continuously adjustable |
| Platen Diameter | Ø 200 / 250 mm |
| Number of Platens | 2 |
| Dimensions (L×W×D) | 901 × 265 × 710 mm |
| Power Supply | 1.0 kVA |
| Rated Output (S1 duty) | 0.55 kW |
| Weight | ~45–49 kg |
| Water Inlet | R½", max. 6 bar |
| Optional Dosing System | Qdoser GO or Qdoser ONE |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpol 250A1-ECO |
| Dimensions (L×W×D) | 511 × 265 × 710 mm |
| Number of Grinding/Polishing Plates | 1 |
| Plate Diameter | 200–300 mm |
| Plate Speed | 30–600 rpm |
| Head Speed | 30–160 rpm |
| Load Force Range (Single Point) | 5–80 N |
| Central Load Force Range | 20–285 N (up to 350 N in Professional Mode) |
| Power Supply | 2.3 kVA |
| Motor Power (Plate Drive) | 0.55 kW (S1) |
| Motor Power (Head Drive) | 0.18 kW (S1) |
| Water Inlet | R½", max. 6 bar |
| Weight | 64–72 kg |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpol 250A2 |
| Dimensions (L×W×D) | 901 × 530–610 × 710 mm |
| Number of Platters | 2 |
| Platter Diameter | Ø 200 / 250 mm |
| Rotational Speed Range | 30–600 rpm |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpol 30 |
| Motor Drive | Dual-micromotor control unit with integrated gear reduction |
| Speed Range | 1,000–40,000 rpm (continuously adjustable) |
| Platen Diameter | 30 mm |
| Number of Platens | 1 |
| Dimensions (L×W×D) | 130 × 97 × 254 mm |
| Weight | ~2.3 kg |
| Power Supply | 230 V, 50–60 Hz |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | QPOL 300 A1-ECO+ |
| Disc Diameter | Ø250/300 mm |
| Disc Quantity | 1 |
| Rotational Speed (Platen) | 30–600 rpm |
| Rotational Speed (Head) | 30–160 rpm |
| Platen Spin-Dry Function | 750 rpm for 3 s |
| Sample Capacity (Single Point) | 1–6 specimens (Ø50 mm) |
| Center Load Pressure Range | 20–350 N |
| Single-Point Load Pressure Range | 5–80 N |
| Dimensions (L×W×D) | 511 × 530–610 × 710 mm |
| Weight | 64 kg |
| Power Supply | 2.8 kVA |
| Motor Rating (Platen) | 0.75 kW (S1) |
| Motor Rating (Head) | 0.18 kW (S1) |
| Water Inlet | R½", max. 6 bar |
| Optional Dosing System | Qdoser ECO / Qdoser ONE |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | QPOL 300 A2-ECO+ |
| Disc Diameter | 250/300 mm |
| Number of Discs | 2 |
| Rotational Speed (Platen) | 30–600 min⁻¹ |
| Rotational Speed (Head) | 30–160 min⁻¹ |
| Platen Cleaning Spin Speed | 750 min⁻¹ (3 s) |
| Sample Capacity (per station) | 1–6 pcs (Ø50 mm) |
| Central Load Range | 20–350 N |
| Single-Point Load Range | 5–80 N |
| Power Supply | 3.3 kVA |
| Motor Power (Platen) | 0.75 kW (S1) |
| Motor Power (Head) | 0.18 kW (S1) |
| Dimensions (L×W×H) | 901 × 530–610 × 710 mm |
| Weight | ~78 kg |
| Water Inlet | R½", max. 6 bar |
| Optional Dosing System | Qdoser ECO / Qdoser ONE |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | QPOL 300 BOT |
| Platen Diameter | 300 mm |
| Number of Platens | 1 |
| Enclosure Material | Anodized Aluminum |
| Automation Level | Fully Sequential, Step-to-Step Process Control |
| Sample Holder Capacity per Station | Up to 6 specimens (configurable) |
| Safety Compliance | Integrated Light Curtain (EN ISO 13857), Emergency Stop Circuit (EN 60204-1) |
| Programmable Steps | Up to 11 sequential operations (pre-grinding, grinding, polishing, cleaning, drying, etc.) |
| Control Interface | 10.1″ TFT Touchscreen with Multi-Language GUI (English, German, French, Chinese) |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpol 300 M1 |
| Rotational Speed | 30–600 rpm, continuously adjustable |
| Platen Diameter | Ø 250 / 300 mm |
| Number of Platens | 1 |
| Dimensions (L×W×D) | 511 × 265 × 710 mm |
| Weight | ~37–45 kg |
| Power Supply | 1.8 kVA |
| Rated Output (S1 duty) | 0.75 kW |
| Water Inlet | R½", max. 6 bar |
| Optional Accessories | Qpol GO automatic grinding/polishing head, Qdoser GO or Qdoser ONE dosing system |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpol 300M2 |
| Disc Diameter | Ø250/300 mm |
| Speed Range | 30–600 rpm, continuously adjustable |
| Dimensions (L×W×D) | 901 × 265 × 710 mm |
| Weight | ~57–65 kg |
| Power Supply | 2.3 kVA |
| Motor Rating | 2 × 0.75 kW (S1 duty) |
| Water Inlet | R½", max. 6 bar |
| Disc Rotation | Clockwise & Counterclockwise |
| Optional Accessories | Qpol GO automatic polishing head, Qdoser GO / Qdoser ONE dosing system |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpol Vibro (Saphir Vibro) |
| Dimensions (L×W×D) | 510 × 300 × 590 mm |
| Polishing Dish Count | 1 |
| Polishing Dish Diameter | 300 mm |
| Drive Mechanism | Electromagnetic vibratory drive with automatic frequency control (60–120 Hz) |
| Weight | 45 kg |
| Sample Capacity | Up to 21 specimens simultaneously (using standard 30 mm / 1.25″ holders) |
| Interface | Touchscreen HMI with preloaded preparation protocols |
| Programmability | Up to 200 user-defined protocols via USB |
| Safety Features | Interlocked buffer shield, exhaust port for external fume extraction, intermittent vibration post-cycle, vibration-damping chassis |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | QPOL XL |
| Drive Motor Power (Platen) | 2.2 kW (S1) |
| Drive Motor Power (Head) | 0.75 kW (S1) / 1.1 kW (S3) |
| Platen Diameter | 300 / 350 mm |
| Platen Speed | 50–600 rpm |
| Head Rotation Speed | 50–350 rpm |
| Applied Force Range | 50–750 N |
| Force Control | Electronic load cell with real-time feedback |
| Number of Liquid Dispensers | Up to 6 |
| Safety Hood | Motorized, interlocked |
| Weight | ~390 kg |
| Dimensions (L×W×H) | 1055 × 860 × 1600 mm |
| Electrical Supply | 400 V / 50 Hz (3Ph/N/PE), 480 V / 60 Hz (3Ph/N/PE), or 220 V / 60 Hz (3Ph/N/PE) |
| Max. Power Consumption | 6 kVA |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Qpress 40 (formerly ATM Opal 410) |
| Mounting Cylinder Diameter Range | Ø25.2–50 mm (6 standard sizes) |
| Clamping System | Threaded lid closure |
| Heating Range | 20–200 °C |
| Heating Time | 0–30 min (adjustable) |
| Cooling Time | 0–30 min (adjustable) |
| Maximum Pressure | 450 bar (pressure output varies with die size) |
| Power Supply | 3.1 kVA |
| Heating Power | 4 × 500 W = 2000 W |
| Dimensions (W × H × D) | 350 × 400 × 450 mm |
| Weight | ~40 kg |
| Cooling Method | Integrated water-cooling circuit |
| Automation Level | Fully automatic hydraulic cycle control with sequential process execution |
| Die Change | Tool-free quick-change mounting cylinder assembly |
| Enclosure Material | Powder-coated aluminum alloy chassis |
| Brand | QATM (Odemag) |
|---|---|
| Origin | Germany |
| Model | Qpress 50 |
| Instrument Type | Hot Mounting Press |
| Mounting Modules | 2 (Qpress 50-2) or 4 (Qpress 50-4) |
| Mold Diameter Options | 25.2, 30, 32, 38, 40, 50 mm |
| Heating Range | 20–200 °C |
| Heating Power | 1200 W |
| Basic Unit Power Input | 1.6 kVA |
| Additional Module Power Input | 1.5 kVA |
| Operating Pressure Range | 250–350 bar (dependent on mold size) |
| Dimensions (Basic Unit) | 402 × 382 × 563 mm (W × H × D) |
| Dimensions (Additional Module) | 187 × 382 × 449 mm (W × H × D) |
| Weight | ~50 kg |
| Brand | QATM (formerly ATM) |
|---|---|
| Origin | Germany |
| Model | Saphir 550 (compatible with Rubin 520 grinding/polishing head) |
| Dimensions (L×W×D) | 560 × 550–650 × 660 mm |
| Number of Grinding/Polishing Plates | 1 |
| Plate Diameter | Ø 200–300 mm |
| Main Plate Speed | 50–600 rpm |
| Rubin 520 Head Speed | 30–150 rpm |
| Sample Capacity (per cycle, single-point loading) | 1–6 specimens (up to Ø 50 mm) |
| Single-Point Load Range | 5–100 N |
| Central Load Range | 20–400 N |
| Power Supply | 3.2 kVA |
| Base Unit Power Consumption (S6/40% duty cycle) | 0.75 kW |
| Rubin Head Power Consumption (S1 continuous) | 0.17 kW |
| Operating Water Pressure | ≤ 6 bar (R½" inlet) |
| Weight | ~85 kg |
| Precision Material Removal Control | ±0.1 mm depth resolution |
| Brand | QATM |
|---|---|
| Origin | Germany |
| Model | Saphir 560 (Rubin 520) |
| Speed Range | 50–600 rpm |
| Platen Diameter | 200–300 mm |
| Number of Platens | 2 |
| Dimensions (L×W×D) | 1020 × 550–650 × 660 mm |
| Single-Point Load Force | 5–100 N |
| Center-Load Force | dependent on chuck configuration |
| Grinding Head Speed | 30–150 rpm |
| Power Supply | 5.5 kVA |
| Base Unit Power Rating | 2 × 0.75 kW (S6/40%) |
| Grinding Head Power Rating | 0.17 kW (S1) |
| Weight | ~110 kg |
| Water Inlet | R½", max. 6 bar |
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Model | ABN-PCM-001 |
| Instrument Type | Benchtop Low-Temperature RF Plasma Surface Treater |
| Working Gases | Dual-Channel (Ar, O₂, N₂, H₂, CF₄ compatible) |
| Control Method | Dual-Independent Mass Flow Control |
| Chamber Material | Fused Quartz |
| Vacuum System | Integrated Rotary Vane Pump (Ultimate Pressure ≤ 5 × 10⁻² mbar) |
| RF Power Supply | 13.56 MHz, 0–100 W Adjustable |
| Chamber Volume | 8 L |
| Operating Temperature | Ambient to 60 °C (non-thermal plasma regime) |
| Brand | BROT-LAB |
|---|---|
| Origin | France |
| Model | W 05 02 |
| Cutting Wheel Diameter | 400 mm (up to 500 mm optional) |
| Max Cutting Depth | 125 mm |
| Max Core Length | 300 mm (1000 mm optional) |
| Coolant | Water or Oil |
| Power Supply | 220 V AC, 50 Hz, 4000 W |
| Weight | 320 kg |
| Instrument Type | Precision Core Cutting Machine |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | CNC2 |
| Weight | 150 kg |
| Dimensions (W×D×H) | 1230 × 830 × 830 mm |
| Power Supply | 220–240 VAC, 50 Hz, Single-Phase |
| Spindle Power | 1.5 kW |
| Spindle Speed Range | 2,400 – 24,000 rpm |
| XYZ Travel Range (approx.) | 600 × 300 × 175 mm |
| Worktable Size | 910 × 480 mm |
| Guidance System | High-Precision Linear Rails & Ball Screws |
| Safety Enclosure | Fully Interlocked, Light-Protected Cabinet with Internal LED Lighting and Emergency Stop |
| Control Software | FlashCut CNC (PC-Based, Not Included) |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Auto GDA-36 |
| Instrument Type | Graphite Digestion System |
| Automation Level | Fully Automated |
| Sample Capacity | 36 positions |
| Max Heating Temperature | 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Electrically Heated Graphite Conduction |
| Reagent Channels | 12 independent channels |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Auto GDA-72 |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Fully Automated |
| Sample Capacity | 72 positions |
| Max Heating Temperature | 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Graphite Block with PTFE Coating |
| Reagent Channels | 12 independent, corrosion-resistant reagent delivery lines |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | M36 |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Semi-Automatic |
| Sample Capacity | 36 positions |
| Temperature Range | Ambient to 450 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Principle | Electric Resistive Heating |
| Reagent Channels | 36 |