| Brand | Hesix |
|---|---|
| Origin | Hunan, China |
| Model | DD5 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–5000 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 500 mL |
| Acceleration/Deceleration | 10-step programmable |
| Timer Range | 1–99 min, continuous, or short-spin mode |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Motor | Brushless AC servo motor |
| Display | TFT-LCD color touchscreen with bilingual (English/Chinese) interface |
| Certifications | CFDA registered, ISO 9001:2015 & ISO 13485:2016 certified |
| Dimensions (L×W×H) | 630 × 500 × 420 mm |
| Weight | 65 kg |
| Brand | Hesix |
|---|---|
| Model | DD5M |
| Type | Floor-standing centrifuge |
| Maximum capacity | 6 × 500 mL |
| Maximum speed | 5000 rpm |
| Maximum RCF | 4800 × g |
| Temperature range | Not refrigerated (optional refrigeration available) |
| Dimensions (L×W×H) | 740 × 620 × 900 mm |
| Weight | 85 kg (non-refrigerated) / 180 kg (refrigerated) |
| Power supply | AC 220 V, 50 Hz |
| Noise level | ≤65 dB(A) |
| Acceleration/deceleration | 10-step control |
| Programmable methods | 20 user-defined protocols |
| Certifications | CFDA registered, ISO 9001:2015 & ISO 13485:2016 compliant |
| Brand | Hesix |
|---|---|
| Model | HR26M |
| Type | Floor-standing refrigerated centrifuge |
| Max. Capacity | 4 × 1000 mL |
| Max. Speed | 25,000 rpm |
| Max. RCF | 58,695 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤65 dB(A) |
| Dimensions (L×W×H) | 840 × 730 × 960 mm |
| Weight | 260 kg |
| Power Supply | AC 220 V, 50 Hz |
| Refrigerant | R404a (non-CFC) |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Compliance | EU EMC Directive 2014/30/EU, IEC 61131-2:2007, NEMA 4, CE, RoHS 2015/863 |
| Brand | Hesix |
|---|---|
| Origin | Hunan, China |
| Model | HR26M Continuous-Flow |
| Instrument Type | Floor-Standing Centrifuge |
| Max Speed | 25,000 rpm |
| Max RCF | 58,695 × g |
| Max Capacity | 4 × 1000 mL (batch) / 3 L/h (continuous flow) |
| Temperature Range | –20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Refrigerant | R404a (non-CFC) |
| Dimensions (L×W×H) | 840 × 730 × 960 mm |
| Weight | 260 kg |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Certifications | CFDA Registered, ISO 9001:2015 & ISO 13485:2016 Certified |
| Drive System | AC Frequency-Controlled Motor |
| Rotor Material | Forged Titanium Alloy (continuous-flow rotor), Anodized Aluminum (fixed-angle rotors) |
| Display | TFT-LCD Touchscreen with Multilingual UI (EN/CN) |
| Brand | Hesix |
|---|---|
| Origin | Hunan, China |
| Model | TD5 |
| Instrument Type | Benchtop Centrifuge |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 4800 ×g |
| Maximum Capacity | 4 × 250 mL |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Power Supply | AC 220 V, 50 Hz |
| Noise Level | ≤60 dB(A) |
| Timer Range | 1 min–99 h 59 min / Continuous / Short Spin |
| Acceleration/Deceleration | 10-step control |
| Stored Programs | 20 user-defined protocols |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Rotor Material | Forged aluminum (angle rotors), polyamide fiber adapters available |
| Safety | Airtight biocontainment angle rotor with RoHS-compliant silicone sealing ring, 304 stainless steel chamber, triple-layer steel protection housing, brushless DC motor with electronic imbalance detection, over-speed/over-temperature/under-voltage/over-voltage protection, soft-lock motorized door latch |
| Brand | Hesix |
|---|---|
| Origin | Hunan, China |
| Instrument Type | Benchtop Centrifuge |
| Maximum Speed | 6000 rpm |
| Maximum RCF | 4800 ×g |
| Maximum Capacity | 4 × 250 mL |
| Acceleration/Deceleration Steps | 10-step adjustable |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Certifications | CFDA Registered & Manufactured, ISO 9001:2015, ISO 13485:2016 |
| Rotor Types | Fixed-angle, Horizontal, Microplate (96-well), and Vacuum Blood Tube Configurations |
| Brand | Hesix |
|---|---|
| Origin | Hunan, China |
| Model | TGL20MW |
| Maximum Capacity | 6 × 250 mL |
| Maximum Speed | 20,600 rpm |
| Maximum RCF | 30,550 × g |
| Temperature Range | −20 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Refrigerant | R404a (non-CFC) |
| Dimensions (W×D×H) | 630 × 760 × 400 mm |
| Weight | 110 kg |
| Noise Level | ≤60 dB(A) |
| Acceleration/Deceleration Control | 10 selectable rates |
| Programmable Protocols | 20 user-defined methods |
| Rotor Recognition | Automatic |
| Timer Range | 1 min – 99 h 59 min (including continuous and short-spin modes) |
| Power Supply | 220 V / 50 Hz |
| Total Power | 1.8 kW |
| Speed Accuracy | ±50 rpm |
| Brand | Hesix |
|---|---|
| Model | TL8R |
| Type | Floor-standing refrigerated centrifuge |
| Max. Speed | 8,000 rpm |
| Max. RCF | 6,142 ×g |
| Max. Capacity | 4 × 750 mL (horizontal rotor) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Noise Level | ≤65 dB(A) |
| Power | 2.0 kW |
| Dimensions (W×D×H) | 710 × 560 × 770 mm |
| Weight | 150 kg |
| Acceleration/Deceleration | 10-step control |
| Programs Stored | 20 user-defined |
| Rotor Recognition | Automatic |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Brand | Hesiy |
|---|---|
| Origin | Hunan, China |
| Model | HR/T20MM |
| Instrument Type | Floor-standing refrigerated centrifuge |
| Speed Range | 10,000–20,600 rpm |
| Max RCF | 29,280 ×g |
| Max Capacity | 4 × 750 mL (horizontal rotor) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 710 × 560 × 770 mm |
| Weight | 150 kg |
| Power Supply | AC 220 V, 50 Hz |
| Motor | Brushless AC frequency-controlled motor |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Compliance | RoHS 2015/863 (silicone O-ring sealing) |
| Rotor Auto-ID | Yes |
| Acceleration/Deceleration | 10 programmable rates |
| Programmable Methods | 20 user-defined protocols |
| Brand | Hesiy |
|---|---|
| Origin | Hunan, China |
| Model | MBB-TD5 |
| Instrument Type | Benchtop Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 250 mL |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 100–230 V, 50/60 Hz |
| Weight | 35 kg |
| Certifications | CFDA Registered, ISO 9001:2015 & ISO 13485:2016 Certified |
| Rotor Type | Horizontal Swing-Bucket Microplate Rotor (2×2×96-well format) |
| Acceleration/Deceleration | 10-step programmable |
| User Programs | 20 stored protocols |
| Brand | Hesiyi |
|---|---|
| Model | 3H24RI |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 24,000 rpm |
| Max RCF | 41,470 ×g |
| Max Capacity | 4 × 100 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10 selectable rates |
| Noise Level | ≤60 dB(A) |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 710 × 630 × 350 mm |
| Weight | 75 kg |
| Refrigerant | R404a (non-CFC) |
| Rotor Recognition | Automatic |
| Display | 4.3″ TFT color touchscreen |
| Programmable Methods | 100 stored protocols |
| Motor | Brushless DC frequency-controlled motor |
| Safety | Triple-layer steel rotor chamber, imbalance detection, overspeed protection, overtemperature cutoff, auto-lock door mechanism |
| Brand | Hesiyi |
|---|---|
| Origin | Hunan, China |
| Model | HR26M |
| Type | Floor-standing centrifuge |
| Max Speed | 25,000 rpm |
| Max RCF | 58,695 ×g |
| Max Capacity | 4 × 1000 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤65 dB(A) |
| Power | 4.0 kW |
| Dimensions (L×W×H) | 840 × 730 × 960 mm |
| Weight | 260 kg |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Compliance | CE, RoHS 2015/863, NEMA 4, IEC 61131-2:2007, EU EMC Directive 2014/30/EU |
| Brand | Hesiyi |
|---|---|
| Origin | Hunan, China |
| Model | LXL-HR21M |
| Instrument Type | Floor-Standing Centrifuge |
| Max Speed | 21,000 rpm |
| Max RCF | 48,811 ×g |
| Max Capacity | 6 × 500 mL (fixed-angle) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10 programmable ramps |
| Display | 4.3″ TFT color touchscreen |
| Power Supply | AC 220 V / 50 Hz / 30 A |
| Noise Level | <65 dB(A) |
| Dimensions (L×W×H) | 820 × 710 × 950 mm |
| Weight | 240 kg |
| Certifications | ISO 9001, ISO 13485 |
| Refrigerant | R404a (non-ozone-depleting) |
| Brand | Hesley |
|---|---|
| Origin | Hunan, China |
| Model | 3H30RI |
| Type | Benchtop Refrigerated High-Speed Centrifuge |
| Max Speed | 30,000 rpm |
| Max RCF | 62,400 ×g |
| Max Capacity | 4 × 100 mL |
| Temperature Range | −20 °C to 40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10 selectable rates |
| Noise Level | ≤58 dB(A) |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 710 × 630 × 350 mm |
| Weight | 75 kg |
| Refrigerant | R404a (non-CFC) |
| Rotor Recognition | Automatic |
| Timer Range | 0–99 h 59 min |
| Motor | Brushless AC frequency-controlled |
| Display | 4.3″ TFT color touchscreen |
| Programmable Methods | 100 stored protocols |
| Safety Certifications | Triple-layer steel rotor chamber, imbalance detection, overspeed/overtemperature/door interlock protection |
| Sterilization Compatibility | Metal rotors autoclavable at 121 °C |
| Brand | Hesley |
|---|---|
| Origin | Hunan, China |
| Model | TD5A |
| Type | Benchtop Centrifuge |
| Max Speed | 5500 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 250 mL |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤60 dB(A) |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Power Supply | AC 220 V, 50 Hz |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Display | TFT-LCD touch + physical keys |
| Motor | High-torque brushless DC motor |
| Safety | Airtight biocontainment rotor (RoHS-compliant silicone seal), 304 stainless steel chamber, triple-layer steel protection housing, imbalance/over-speed/over-temperature/under-voltage/over-voltage protection, automatic door lock |
| Brand | Hesley |
|---|---|
| Model | DD5 |
| Type | Low-Speed Benchtop Centrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 2780 ×g |
| Max Capacity | 4 × 250 mL (conical-bottom tubes) |
| Timer Range | 1 min – 99 h 59 min, continuous & short-spin modes |
| Power Supply | 220 V AC or 12/24 V DC (vehicle-compatible) |
| Noise Level | ≤60 dB(A) |
| Dimensions (W×D×H) | 630 × 500 × 420 mm |
| Weight | 65 kg |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Safety | RoHS-compliant silicone gasket, 304 stainless steel rotor chamber, triple-damping suspension, electronic lid lock, multi-parameter real-time monitoring (overspeed, overtemperature, imbalance, under/over-voltage) |
| Brand | Hesley |
|---|---|
| Origin | Hunan, China |
| Model | DD5M |
| Type | Floor-Standing Centrifuge |
| Max Capacity | 6 × 500 mL |
| Max Speed | 5000 rpm |
| Max RCF | 4800 × g |
| Dimensions (L×W×H) | 740 × 620 × 900 mm |
| Weight | 85 kg (non-refrigerated) / 180 kg (refrigerated option) |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Motor | AC Brushless Inverter Motor |
| Control System | Microprocessor-Based with TFT-LCD Touchscreen Interface |
| Programmable Methods | 20 User-Defined Protocols |
| Acceleration/Deceleration | 10 Steps Each |
| Certifications | CFDA Registered, ISO 9001:2015 & ISO 13485:2016 Compliant |
| Refrigeration Option | Optional R404a Compressor System (Temp Range: –20°C to +40°C) |
| Brand | Hesley |
|---|---|
| Origin | Hunan, China |
| Model | NJ-LR6M |
| Type | Floor-standing refrigerated centrifuge |
| Max. Speed | 4200 rpm |
| Max. RCF | 5167 ×g |
| Max. Capacity | 6 × 1000 mL (horizontal rotor) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Programs Stored | 16 user-defined |
| Noise Level | <65 dB(A) |
| Dimensions (L×W×H) | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Power Supply | AC 220 V / 50 Hz / 30 A |
| Total Power | 4.0 kW |
| Refrigerant | R404a (non-CFC) |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Brand | Hesley |
|---|---|
| Origin | Hunan, China |
| Model | TD5 WRV Centrifuge |
| Instrument Type | Benchtop Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 250 mL |
| Acceleration/Deceleration | 10-step control |
| Timer Range | 1–99 h 59 min / Continuous / Short-spin |
| Speed Accuracy | ±50 rpm |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Compliance | GB/T 29286–2012 |
| Brand | Hesley |
|---|---|
| Origin | Hunan, China |
| Model | TD5A |
| Instrument Type | Benchtop Centrifuge |
| Maximum Speed | 4000 rpm |
| Maximum RCF | 2650 ×g |
| Maximum Capacity | 4 × 50 mL |
| Rotor Type | Horizontal (Swinging-Bucket) Rotor |
| Acceleration/Deceleration Control | 10-step programmable |
| Timer Range | 1–99 h 59 min, continuous, or short-spin mode |
| Speed Accuracy | ±50 rpm |
| Power Supply | AC 220 V, 50 Hz |
| Noise Level | ≤60 dB(A) |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Certifications | CFDA Registered Device, ISO 9001:2015 & ISO 13485:2016 Certified |
| Compliance | RoHS 2015/863 (Silicone Sealing Ring), FDA-recognized design principles for clinical specimen processing |
| Brand | Hesley |
|---|---|
| Origin | Hunan, China |
| Model | TD5A |
| Instrument Type | Benchtop Centrifuge |
| Maximum Speed | 4000 rpm |
| Maximum RCF | 2100 ×g |
| Maximum Capacity | 4 × 50 mL |
| Rotor Type | Horizontal Swing-Out Rotor (sterilizable) |
| Acceleration/Deceleration Control | 10-step programmable |
| Timer Range | 1–99 h 59 min, continuous, or short-spin mode |
| Power Supply | AC 220 V, 50 Hz |
| Noise Level | ≤60 dB(A) |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Compliance | RoHS 2015/863 (silicone O-ring seal), GLP-ready design |
| Brand | Hesley |
|---|---|
| Origin | Hunan, China |
| Model | TDL6M |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 6500 rpm |
| Max RCF | 4800 × g |
| Max Capacity | 4 × 500 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤65 dB(A) |
| Dimensions (L×W×H) | 630 × 760 × 400 mm |
| Weight | 110 kg |
| Power | 1.8 kW |
| Timer Range | 1 min – 99 h 59 min |
| Certified | ISO 9001:2015, ISO 13485:2016, CFDA Registered |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 3H16RI |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (High-Speed) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Level | Cellular & Bacterial |
| Max Capacity | 4 × 100 mL |
| Max Speed | 16,800 rpm |
| Max RCF | 20,320 × g |
| Dimensions | 710 × 630 × 350 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤60 dB(A) |
| Power Supply | 220 V, 50 Hz |
| Weight | 75 kg |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registered |
| Rotor Recognition | Automatic |
| Display | TFT-LCD touchscreen + physical keys |
| Language Options | English, Chinese, Russian, Portuguese |
| Refrigerant | R404a (non-ozone-depleting, RoHS 2015/863 compliant) |
| Safety | Airtight biocontainment rotors with silicone sealing, triple-layer steel protection housing, rear stainless-steel chamber, brushless DC motor with 3-stage damping, real-time imbalance detection, overspeed/overtemperature/under-voltage/over-voltage protection |
| Pre-cooling & Hold-at-Temp | Yes |
| Defrost Mode | Electric heating defrost |
| Programmability | 100 user-defined protocols, parameter editing during run, last-program recall on startup |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | Hettich 710BY |
| Price Range | USD 1,400 – 4,200 |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Low-Speed Centrifuge (≤ 5,000 rpm) |
| Function | General-Purpose Centrifuge |
| Configuration | Fixed-Angle Rotor System |
| Maximum Capacity | 4 × 250 mL |
| Max. Rotational Speed | 4,000 rpm |
| Max. RCF | 2,578 × g |
| Dimensions (W × D × H) | 330 × 330 × 251 mm |
| Acceleration/Deceleration Stages | 10-step programmable |
| Construction | AISI 304 stainless steel chamber + powder-coated steel housing + triple-layer reinforced safety shield |
| Control Interface | Bluetooth 5.0 + WeChat Mini Program (iOS/Android) |
| Operational Range | Up to 10 m line-of-sight |
| Connectivity Features | Real-time Bluetooth signal strength monitoring, auto-reconnect on dropout, parameter retention after power cycle, runtime logging with timestamped event records |
| Key | Brand: Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 7116R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–16,500 rpm |
| Max RCF | 22,500 × g |
| Max Capacity | 48 × 2.0 mL tubes |
| Temperature Range | −20 °C to +40 °C |
| Display | 7-inch capacitive touchscreen |
| Dimensions (W×D×H) | 650 × 350 × 325 mm |
| Rotor Configuration | Fixed-angle rotor standard (compatible with PCR 8-tube strips, 0.2–2.0 mL microtubes) |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BE-6100H |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 2500 rpm |
| Max RCF | 500 × g |
| Max Capacity | 2 × 96-well PCR plates |
| Rotor Configuration | Vertical fixed-angle rotor for microplates |
| Power Supply | 110–220 V, 50–60 Hz |
| Power Consumption | 20 W |
| Dimensions (W × D × H) | 210 × 190 × 190 mm |
| Weight | 3 kg |
| Compliance | CE-marked per IEC 61010-1 for laboratory equipment |
| Intended Use | Low-speed pelleting of liquids in standard microplates for molecular biology workflows |
| Brand | Hettich |
|---|---|
| Model | DD5 |
| Centrifuge Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 500 mL |
| Acceleration/Deceleration | 10-step control |
| Timer Range | 1–99 min, continuous, or short-spin mode |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Motor | Brushless AC motor |
| Weight | 65 kg |
| Dimensions (L×W×H) | 630 × 500 × 420 mm |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Compliance | RoHS 2015/863 (silicone O-ring sealing) |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich DD5M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 0–5,000 rpm |
| Max RCF | 4,800 × g |
| Max Capacity | 6 × 500 mL (horizontal rotor) |
| Temperature Range | –20 °C to +40 °C |
| Refrigerant | R404a (non-ozone-depleting, RoHS-compliant) |
| Control Interface | TFT-LCD touchscreen + physical keys |
| Language Support | English, Chinese, Russian, Portuguese |
| Safety Certifications | CFDA Registered & Licensed, ISO 9001:2015, ISO 13485:2016 |
| Drive System | AC brushless motor with Infineon driver module and custom control board |
| Vibration Damping | Triple-stage damping + composite shock absorption |
| Door Lock | Electromechanical silent latch with auto-engagement |
| Acceleration/Deceleration | 10-step programmable |
| User Programs | 20 stored protocols |
| Chamber Material | AISI 304 stainless steel |
| External Casing | Powder-coated steel with reinforced front panel and triple-layer safety housing |
| Rotor Seal | Integrated silicone gasket (EU RoHS 2015/863 compliant) |
| Pre-cooling & Hold Cooling | Yes |
| Defrost Function | Electric heating defrost |
| Dimensions (W×D×H) | 740 × 620 × 900 mm |
| Net Weight | Approx. 125 kg |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Hettich DD5M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Category | Low-Speed Centrifuge (≤ 5,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Max Capacity | 6 × 500 mL |
| Max Speed | 5,000 rpm |
| Max RCF | 4,800 × g |
| Dimensions (W×D×H) | 740 × 620 × 900 mm |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R404a (non-ozone-depleting, RoHS-compliant) |
| Drive System | AC Brushless Frequency-Controlled Motor |
| Control Interface | TFT-LCD True-Color Touchscreen + Physical Keypad |
| Language Support | English, Chinese, Russian, Portuguese |
| Safety Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registered Device |
| Rotor Seal | Integrated Silicone Rubber Gasket (EU RoHS 2015/863 Compliant) |
| Chamber Material | AISI 304 Stainless Steel |
| Door Lock | Electromechanical Interlocked Lid with Auto-Engagement |
| Acceleration/Deceleration | 10-Step Programmable Ramp Control |
| User Programs | 20 Storage Slots |
| Vibration Damping | Triple-Stage Composite Damping System |
| Additional Features | Pre-cooling, Hold-at-Temperature Standby Mode, Defrost Heating, Real-Time Parameter Adjustment During Run, RCF Display Key, Audible & Visual Alarms for Overspeed, Overtemperature, Imbalance, Under/Over Voltage |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | EBA 270 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4,000 rpm |
| Max RCF | 2,254 × g |
| Max Capacity | 6 × 15 mL |
| Dimensions (H×W×D) | 239 × 326 × 389 mm |
| Weight | 14 kg |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 130 VA |
| Electromagnetic Compatibility | EN/IEC 61326-1 Class B |
| Timer Range | 1–99 min, ∞ (continuous), and short-spin mode |
| Safety Certification | Compliant with IEC 61010-1 for laboratory equipment |