| Brand | AYAO Instruments |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LithoMaskless |
| Exposure Mode | Projection-Based |
| Resolution | 0.5 µm |
| Light Source | UV LED |
| Wavelength Options | 365 nm / 385 nm / 405 nm |
| Maximum Exposure Area | 100 mm × 100 mm |
| DMD Chip Size | 0.65-inch |
| Compatibility | Broad photoresist & substrate support (Si, SiO₂, glass, quartz, flexible polymers) |
| Alignment Method | Integrated high-magnification optical alignment with real-time feedback |
| Brand | AYAO Instruments |
|---|---|
| Origin | Hubei, China |
| Model | OPA |
| Type | Optical Power-Based Thermal Dilatometer & Phase Transition Analyzer |
| Measurement Principle | Optical Interferometry (for thermal expansion) + Reflectance Power Monitoring (for phase transition) |
| Sample Form | Free-standing films, substrate-supported thin films, bulk materials |
| Minimum Film Thickness | 1 nm |
| Non-Destructive Testing | Yes |
| Dual-Parameter Output | Coefficient of Thermal Expansion (CTE) and Phase Transition Temperature (e.g., crystallization, melting, glass transition) |
| Compliance Context | Designed for R&D environments requiring traceable, repeatable thermal property data in accordance with ISO 11359 (thermomechanical analysis), ASTM E831 (linear thermal expansion), and GLP-aligned data integrity practices |
| Brand | Ayao Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HET |
| Pricing | Upon Request |
| Instrument Type | Variable-Temperature Hall Effect Tester |
| Measurement Principle | Van der Pauw Method |
| Sample Form | Thin Films & 2D Layers |
| Compatible Materials | Si, ZnO, SiGe, SiC, GaAs, InGaAs, InP, GaN (n-type & p-type) |
| Temperature Range | Cryogenic to 500 K (configurable with optional cryostat or furnace) |
| Magnetic Field Range | ±1.5 T (standard electromagnet), up to ±9 T (with superconducting magnet option) |
| Current Source Accuracy | ±0.05% of reading |
| Voltage Measurement Resolution | 100 nV |
| Data Acquisition Rate | Up to 100 samples/sec per channel |
| Software Compliance | Supports ASTM F76, ISO/IEC 17025 traceability logs, GLP-compliant audit trail (optional) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | AbsorptoMeter |
| Standards Compliance | ASTM D2414, ASTM D3493, ASTM D6854 |
| Construction | Stainless steel housing |
| Automation | Software-controlled titration system |
| Titration Range | Adjustable dosing rate, suitable for viscosities up to 1,000,000 mPa·s |
| Solvent Compatibility | Compatible with aggressive solvents (e.g., NMP) |
| Data Management | Real-time result comparison, scheduled measurements, CSV/Excel export |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | FarinoGraph |
| Compliance | ICC, AACCI, ISO 5530-1, ISO 21415 |
| Measurement Unit | Brabender Unit (BU) / Farinograph Unit (FU) |
| Stirring Capacity | 10 g to 300 g |
| Water Dosage | Automated via AquaInject module |
| Data Management | MetaBridge web-based software |
| Connectivity | LIMS/ERP integration supported |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TwinLab |
| Configuration | Modular Twin-Screw / Single-Screw / Batch Mixer |
| Drive Unit | MetaStation |
| Control Software | MetaBridge |
| Temperature Range | Up to 500 °C |
| Throughput Range | 0.05–100 kg/h |
| Screw Diameter Options | 19 mm, 25 mm, and scalable modular configurations |
| Barrel Design | Split-barrel with removable liners |
| Material Compatibility | Liquids, powders, granules, high-abrasive & high-corrosive compounds |
| Compliance | Designed for GLP/GMP-aligned workflows, data audit trail capable (21 CFR Part 11–ready architecture) |
| Data Export | CSV, PDF, email-integrated reporting |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction (DIN EN ISO 15512:2019) |
| Resolution | 0.0001% H₂O |
| Application | Residual Moisture Analysis in Thermoplastics & MFR Sample Preparation |
| Compliance | Fully compliant with DIN EN ISO 15512:2019 for selective water determination in plastics |
| Software | Aquatrac Control Software with LIMS/ERP integration capability |
| Data Integrity | Audit trail, user access levels, electronic signatures (21 CFR Part 11 ready) |
| Brand | AppNano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | VertiSense |
| Instrument Type | Material Science AFM-Compatible SThM Module |
| Primary Function | Nanoscale Thermal Property Mapping (Topography + Thermal Conductivity + Temperature Distribution) |
| Brand | Accurion |
|---|---|
| Origin | Germany |
| Model | Nanofilm_EP4 |
| Spectral Range | 190–2750 nm |
| Spot Size | 1 µm |
| Angle of Incidence | 38°–90° |
| Sample Diameter | 2–12 inches |
| Spectral Resolution | 0.1 nm |
| Thickness Measurement Accuracy | 0.1 nm |
| Thickness Repeatability | 0.01 nm |
| Brand | Accurion |
|---|---|
| Origin | Germany |
| Model Series | Atlas (Heavy-Duty Modular), Reactio Plus (Desktop) |
| Load Capacity | Atlas Module: 300–1000 kg/unit |
| Reactio Plus | 120–150 kg |
| Vibration Isolation Range | ≥1 Hz |
| Isolation Performance | ≥12 dB at 1 Hz |
| Module Dimensions (Atlas) | 240 × 240 × 110 mm |
| Application Target | High-Precision Optical Benches, Moving XY Stages, Audio Equipment, Electron Microscopy, Interferometry |
| Brand | Aiyao Instruments |
|---|---|
| Origin | Taiwan |
| Model | XW-A300 |
| Measurement Principles | Spectral Interferometry (IR), White-Light Interferometry (WLI), Optical Reflectometry |
| Sample Compatibility | 4″–12″ wafers |
| Probe Configuration | Single or Dual (top/bottom) |
| Compliance | SEMI S2/S8 |
| Motion Platform | Air-bearing vibration-isolated stage |
| Software | WaferSpect™ with full mapping, statistical analysis, and GLP-compliant audit trail |
| Brand | AiYao Instruments |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IRIS S |
| Pricing | Available Upon Request |
| Brand | Aiyao Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | AY1000 |
| Output Interface | RS422 Digital Output |
| Operating Frequency Range | ≥0.01 Hz |
| Noise Floor | Ultra-Low (Typ. <10 ng/√Hz below 1 Hz) |
| Form Factor | Miniaturized, Low-Power, Lightweight Design |
| Compliance | Fully Domesticated Architecture |
| Brand | AiYao Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TRT |
| Pricing | Available Upon Request |
| Brand | Aiyao Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PCA |
| Pricing | Available Upon Request |
| Brand | Aiyao Instruments |
|---|---|
| Model | TEA |
| Measurement Principle | Optical Interferometry |
| Sample Type | Transparent Bulk & Thin-Film Materials |
| Heating Method | IR Heater with PID + Fuzzy Logic Control |
| Temperature Control Mode | Programmable Ramp & Isothermal Hold |
| Vacuum Port | Yes |
| Cooling Interface | Water-Cooled Heat Exchanger & Optional Cryogenic/Gas Purge Connection |
| Origin | Hubei, China |
| Distributor Type | Authorized Domestic Distributor |
| Compliance | Designed for ISO 11359-2 and ASTM E228 Conformance Context |
| Brand | Aiyao Instruments |
|---|---|
| Model | TCT |
| Measurement Principle | 3ω Method |
| Sample Form | Micro/Nano Thin Films (Supported & Freestanding) |
| Temperature Range | Ambient to 400 °C (Optional Cryogenic Extension Available) |
| Thermal Conductivity Range | 0.1–1000 W/(m·K) |
| Resolution | <0.5% of Full Scale |
| Data Acquisition | High-Precision Digital Source Meter + Dual-Phase Lock-in Amplifier |
| Compliance | ASTM E1461, ISO 22007-2 (Adapted), GLP-Compatible Audit Trail Logging |
| Brand | NORMALAB |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SC CLASSIC |
| Pricing | Available Upon Request |
| Brand | Onto Innovation |
|---|---|
| Model | Dragonfly® G3 |
| Origin | Malaysia |
| Equipment Type | Inline AOI for Front-End & Advanced Packaging |
| Minimum Detectable Line Width/Spacing | 0.7 µm |
| Wafer Size Support | 100 mm – 330 mm |
| Maximum Substrate Area | >6400 mm² |
| 翘曲晶圆 & Taiko Handling | Supported |
| Imaging Modes | Brightfield, Darkfield, Oblique Illumination, IR Transmission |
| 3D Metrology | Truebump® (Multi-Modal 3D Profilometry) |
| Residue Detection | Clearfind® |
| Software Platform | nLINE™ with Real-Time Analysis, Offline Review, and Exploratory Bump-Level Data Analytics |
| Compliance Framework | Supports ASTM F2598 (Wafer Defect Classification), ISO 14644-1 (Cleanroom Integration), and GLP/GMP-aligned Audit Trail Logging |
| Brand | Endress+Hauser Metrology |
|---|---|
| Origin | Germany |
| Model | MX608 |
| Wafer Diameter Support | 150 mm, 200 mm, 300 mm |
| Thickness Range | 500–800 µm |
| Max Warp | 100 µm |
| Resistivity Range | 0.001–200 Ω·cm |
| Thickness Accuracy | ±0.3 µm |
| TTV Accuracy | ±0.1 µm |
| Thickness Repeatability | ±0.05 µm |
| Resistivity Accuracy | ±1% (0.001–80 Ω·cm), ±5% (200 Ω·cm) |
| Resistivity Repeatability | ±0.2% (0.001–80 Ω·cm), ±2% (200 Ω·cm) |
| Edge Measurement Capability | up to 130 mm (150 mm wafers), up to 180 mm (200 mm wafers) |
| Single-Point Measurement Time | ~7 s |
| Full-Surface Scan (130/180 points) | ~10 s |
| Multi-Angle Radial Scan (18 scans @ 10° intervals) | ~3 min |
| Carrier Type Detection | P/N identification via Surface Photovoltage (SPV) |
| Brand | Ayao Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CARS |
| Instrument Type | Coherent Anti-Stokes Raman Scattering (CARS) Microscope |
| Excitation Wavelength | 1032 nm |
| Spectral Coverage | 500–5000 cm⁻¹ |
| Spatial Resolution | < 0.7 µm |
| Imaging Speed | 3 fs per pixel (typical acquisition time at video rate) |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Model | GDA 750 / GDA 550 |
| Detection Principle | Glow Discharge Optical Emission Spectroscopy (GD-OES) |
| Spectral Range | 190–800 nm (standard PMT system) |
| Spectral Resolution | <20 pm FWHM (PMT) |
| Optical System | Paschen-Runge mount, 750 mm focal length, holographically ruled grating (2400 lines/mm) |
| Max. Analytical Depth | >200 µm |
| Depth Resolution | ≤1 nm |
| Elemental Coverage | H, O, N, Cl, C, and all elements from Li to U |
| Detection Limits | Sub-ppm (matrix-dependent) |
| Sputter Diameter | 1–8 mm (adjustable, same source) |
| DC Source | Up to 1500 V, 250 mA, fully programmable |
| RF Source | Up to 150 W, pulsed mode optional (GDA 750 only) |
| Sample Thickness Range | 50 µm – 45 mm |
| Vacuum System | Dual-stage rotary vane pump (<50 dB), oil-free pump for source chamber |
| Optional Accessories | High-resolution CCD optical system, RF pulse generator, load-lock transfer chamber, 100-position autosampler, monochromator with triple-grating turret |
| Brand | Optomet |
|---|---|
| Origin | Germany |
| Model | Vector-Micro |
| Laser Wavelength | 632 nm |
| Spot Diameter | ~3 µm |
| Frequency Range | 0–25 MHz |
| Integrated Camera | 12 MP (4K resolution) |
| Application Domain | MEMS, microelectronics, precision microstructure vibration analysis |
| Compliance | Designed for ISO 18431-1, ISO 2041, and ASTM E1876-compliant modal testing workflows |
| Software Architecture | Native support for GLP/GMP audit trails, FDA 21 CFR Part 11–compliant data handling |
| Brand | G&N |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MPS R300 CM |
| Pricing | Upon Request |
| Drive Motor | 3.7 kW |
| Spindle Speed at 50 Hz | 2300 rpm |
| Power Supply Connection | 6 kVA |
| Rotary Table Diameter | 400 mm |
| Table Speed Range | 0–30 rpm |
| Axial Runout | < 2 µm |
| Grinding Wheel Diameter | 200 mm |
| Maximum Grinding Height (Ceramic Wheel) | 45 mm |
| Maximum Grinding Height (CBN/Diamond Wheel) | 110 mm |
| Fine Cross-Feed Travel Range | approx. 170 mm |
| Minimum Feed Increment | 1 µm per pass |
| Machine Dimensions (L × W) | 1550 × 1130 mm |
| Net Weight | 1130 kg |