Empowering Scientific Discovery

Shanghai Aiyao Scientific Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAYAO Instruments
OriginSouth Korea
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelLithoMaskless
Exposure ModeProjection-Based
Resolution0.5 µm
Light SourceUV LED
Wavelength Options365 nm / 385 nm / 405 nm
Maximum Exposure Area100 mm × 100 mm
DMD Chip Size0.65-inch
CompatibilityBroad photoresist & substrate support (Si, SiO₂, glass, quartz, flexible polymers)
Alignment MethodIntegrated high-magnification optical alignment with real-time feedback
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAYAO Instruments
OriginHubei, China
ModelOPA
TypeOptical Power-Based Thermal Dilatometer & Phase Transition Analyzer
Measurement PrincipleOptical Interferometry (for thermal expansion) + Reflectance Power Monitoring (for phase transition)
Sample FormFree-standing films, substrate-supported thin films, bulk materials
Minimum Film Thickness1 nm
Non-Destructive TestingYes
Dual-Parameter OutputCoefficient of Thermal Expansion (CTE) and Phase Transition Temperature (e.g., crystallization, melting, glass transition)
Compliance ContextDesigned for R&D environments requiring traceable, repeatable thermal property data in accordance with ISO 11359 (thermomechanical analysis), ASTM E831 (linear thermal expansion), and GLP-aligned data integrity practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAyao Instruments
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelHET
PricingUpon Request
Instrument TypeVariable-Temperature Hall Effect Tester
Measurement PrincipleVan der Pauw Method
Sample FormThin Films & 2D Layers
Compatible MaterialsSi, ZnO, SiGe, SiC, GaAs, InGaAs, InP, GaN (n-type & p-type)
Temperature RangeCryogenic to 500 K (configurable with optional cryostat or furnace)
Magnetic Field Range±1.5 T (standard electromagnet), up to ±9 T (with superconducting magnet option)
Current Source Accuracy±0.05% of reading
Voltage Measurement Resolution100 nV
Data Acquisition RateUp to 100 samples/sec per channel
Software ComplianceSupports ASTM F76, ISO/IEC 17025 traceability logs, GLP-compliant audit trail (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelAbsorptoMeter
Standards ComplianceASTM D2414, ASTM D3493, ASTM D6854
ConstructionStainless steel housing
AutomationSoftware-controlled titration system
Titration RangeAdjustable dosing rate, suitable for viscosities up to 1,000,000 mPa·s
Solvent CompatibilityCompatible with aggressive solvents (e.g., NMP)
Data ManagementReal-time result comparison, scheduled measurements, CSV/Excel export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelFarinoGraph
ComplianceICC, AACCI, ISO 5530-1, ISO 21415
Measurement UnitBrabender Unit (BU) / Farinograph Unit (FU)
Stirring Capacity10 g to 300 g
Water DosageAutomated via AquaInject module
Data ManagementMetaBridge web-based software
ConnectivityLIMS/ERP integration supported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelTwinLab
ConfigurationModular Twin-Screw / Single-Screw / Batch Mixer
Drive UnitMetaStation
Control SoftwareMetaBridge
Temperature RangeUp to 500 °C
Throughput Range0.05–100 kg/h
Screw Diameter Options19 mm, 25 mm, and scalable modular configurations
Barrel DesignSplit-barrel with removable liners
Material CompatibilityLiquids, powders, granules, high-abrasive & high-corrosive compounds
ComplianceDesigned for GLP/GMP-aligned workflows, data audit trail capable (21 CFR Part 11–ready architecture)
Data ExportCSV, PDF, email-integrated reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar Brabender
OriginGermany
ModelAquatrac-V
Measurement PrincipleCalcium Hydride Reaction (DIN EN ISO 15512:2019)
Resolution0.0001% H₂O
ApplicationResidual Moisture Analysis in Thermoplastics & MFR Sample Preparation
ComplianceFully compliant with DIN EN ISO 15512:2019 for selective water determination in plastics
SoftwareAquatrac Control Software with LIMS/ERP integration capability
Data IntegrityAudit trail, user access levels, electronic signatures (21 CFR Part 11 ready)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAppNano
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelVertiSense
Instrument TypeMaterial Science AFM-Compatible SThM Module
Primary FunctionNanoscale Thermal Property Mapping (Topography + Thermal Conductivity + Temperature Distribution)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAccurion
OriginGermany
ModelNanofilm_EP4
Spectral Range190–2750 nm
Spot Size1 µm
Angle of Incidence38°–90°
Sample Diameter2–12 inches
Spectral Resolution0.1 nm
Thickness Measurement Accuracy0.1 nm
Thickness Repeatability0.01 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAccurion
OriginGermany
Model SeriesAtlas (Heavy-Duty Modular), Reactio Plus (Desktop)
Load CapacityAtlas Module: 300–1000 kg/unit
Reactio Plus120–150 kg
Vibration Isolation Range≥1 Hz
Isolation Performance≥12 dB at 1 Hz
Module Dimensions (Atlas)240 × 240 × 110 mm
Application TargetHigh-Precision Optical Benches, Moving XY Stages, Audio Equipment, Electron Microscopy, Interferometry
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAiyao Instruments
OriginTaiwan
ModelXW-A300
Measurement PrinciplesSpectral Interferometry (IR), White-Light Interferometry (WLI), Optical Reflectometry
Sample Compatibility4″–12″ wafers
Probe ConfigurationSingle or Dual (top/bottom)
ComplianceSEMI S2/S8
Motion PlatformAir-bearing vibration-isolated stage
SoftwareWaferSpect™ with full mapping, statistical analysis, and GLP-compliant audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAiYao Instruments
OriginMalaysia
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelIRIS S
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAiyao Instruments
OriginShanghai, China
ModelAY1000
Output InterfaceRS422 Digital Output
Operating Frequency Range≥0.01 Hz
Noise FloorUltra-Low (Typ. <10 ng/√Hz below 1 Hz)
Form FactorMiniaturized, Low-Power, Lightweight Design
ComplianceFully Domesticated Architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAiYao Instruments
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTRT
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAiyao Instruments
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPCA
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAiyao Instruments
ModelTEA
Measurement PrincipleOptical Interferometry
Sample TypeTransparent Bulk & Thin-Film Materials
Heating MethodIR Heater with PID + Fuzzy Logic Control
Temperature Control ModeProgrammable Ramp & Isothermal Hold
Vacuum PortYes
Cooling InterfaceWater-Cooled Heat Exchanger & Optional Cryogenic/Gas Purge Connection
OriginHubei, China
Distributor TypeAuthorized Domestic Distributor
ComplianceDesigned for ISO 11359-2 and ASTM E228 Conformance Context
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAiyao Instruments
ModelTCT
Measurement Principle3ω Method
Sample FormMicro/Nano Thin Films (Supported & Freestanding)
Temperature RangeAmbient to 400 °C (Optional Cryogenic Extension Available)
Thermal Conductivity Range0.1–1000 W/(m·K)
Resolution<0.5% of Full Scale
Data AcquisitionHigh-Precision Digital Source Meter + Dual-Phase Lock-in Amplifier
ComplianceASTM E1461, ISO 22007-2 (Adapted), GLP-Compatible Audit Trail Logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNORMALAB
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSC CLASSIC
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOnto Innovation
ModelDragonfly® G3
OriginMalaysia
Equipment TypeInline AOI for Front-End & Advanced Packaging
Minimum Detectable Line Width/Spacing0.7 µm
Wafer Size Support100 mm – 330 mm
Maximum Substrate Area>6400 mm²
翘曲晶圆 & Taiko HandlingSupported
Imaging ModesBrightfield, Darkfield, Oblique Illumination, IR Transmission
3D MetrologyTruebump® (Multi-Modal 3D Profilometry)
Residue DetectionClearfind®
Software PlatformnLINE™ with Real-Time Analysis, Offline Review, and Exploratory Bump-Level Data Analytics
Compliance FrameworkSupports ASTM F2598 (Wafer Defect Classification), ISO 14644-1 (Cleanroom Integration), and GLP/GMP-aligned Audit Trail Logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEndress+Hauser Metrology
OriginGermany
ModelMX608
Wafer Diameter Support150 mm, 200 mm, 300 mm
Thickness Range500–800 µm
Max Warp100 µm
Resistivity Range0.001–200 Ω·cm
Thickness Accuracy±0.3 µm
TTV Accuracy±0.1 µm
Thickness Repeatability±0.05 µm
Resistivity Accuracy±1% (0.001–80 Ω·cm), ±5% (200 Ω·cm)
Resistivity Repeatability±0.2% (0.001–80 Ω·cm), ±2% (200 Ω·cm)
Edge Measurement Capabilityup to 130 mm (150 mm wafers), up to 180 mm (200 mm wafers)
Single-Point Measurement Time~7 s
Full-Surface Scan (130/180 points)~10 s
Multi-Angle Radial Scan (18 scans @ 10° intervals)~3 min
Carrier Type DetectionP/N identification via Surface Photovoltage (SPV)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAyao Instruments
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCARS
Instrument TypeCoherent Anti-Stokes Raman Scattering (CARS) Microscope
Excitation Wavelength1032 nm
Spectral Coverage500–5000 cm⁻¹
Spatial Resolution< 0.7 µm
Imaging Speed3 fs per pixel (typical acquisition time at video rate)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSPECTRUMA
OriginGermany
ModelGDA 750 / GDA 550
Detection PrincipleGlow Discharge Optical Emission Spectroscopy (GD-OES)
Spectral Range190–800 nm (standard PMT system)
Spectral Resolution<20 pm FWHM (PMT)
Optical SystemPaschen-Runge mount, 750 mm focal length, holographically ruled grating (2400 lines/mm)
Max. Analytical Depth>200 µm
Depth Resolution≤1 nm
Elemental CoverageH, O, N, Cl, C, and all elements from Li to U
Detection LimitsSub-ppm (matrix-dependent)
Sputter Diameter1–8 mm (adjustable, same source)
DC SourceUp to 1500 V, 250 mA, fully programmable
RF SourceUp to 150 W, pulsed mode optional (GDA 750 only)
Sample Thickness Range50 µm – 45 mm
Vacuum SystemDual-stage rotary vane pump (<50 dB), oil-free pump for source chamber
Optional AccessoriesHigh-resolution CCD optical system, RF pulse generator, load-lock transfer chamber, 100-position autosampler, monochromator with triple-grating turret
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOptomet
OriginGermany
ModelVector-Micro
Laser Wavelength632 nm
Spot Diameter~3 µm
Frequency Range0–25 MHz
Integrated Camera12 MP (4K resolution)
Application DomainMEMS, microelectronics, precision microstructure vibration analysis
ComplianceDesigned for ISO 18431-1, ISO 2041, and ASTM E1876-compliant modal testing workflows
Software ArchitectureNative support for GLP/GMP audit trails, FDA 21 CFR Part 11–compliant data handling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandG&N
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMPS R300 CM
PricingUpon Request
Drive Motor3.7 kW
Spindle Speed at 50 Hz2300 rpm
Power Supply Connection6 kVA
Rotary Table Diameter400 mm
Table Speed Range0–30 rpm
Axial Runout< 2 µm
Grinding Wheel Diameter200 mm
Maximum Grinding Height (Ceramic Wheel)45 mm
Maximum Grinding Height (CBN/Diamond Wheel)110 mm
Fine Cross-Feed Travel Rangeapprox. 170 mm
Minimum Feed Increment1 µm per pass
Machine Dimensions (L × W)1550 × 1130 mm
Net Weight1130 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0