- All
- Favorite
- Popular
- Most rated
| Brand | Auniontech |
|---|---|
| Origin | Germany |
| Type | Gas Laser System |
| Model | V5-10.6 |
| Output Wavelength | 10.6 µm |
| Maximum Output Power | 1650 W |
| Power Tunability Range | 100 W – 1650 W (5–100% of rated power) |
| Beam Quality (M²) | <1.3 |
| Beam Diameter | 14 mm |
| Beam Pointing Stability | ≤0.1 mrad |
| Polarization | Linear |
| Rated Lifetime | >40,000 h (laser head maintenance-free) |
| Operating Mode | True CW (no modulation artifacts) |
| Brand | auniontech (Distributor) |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | SID4-Fast |
| Price | Contact for Quote |
| Brand | Auniontech |
|---|---|
| Origin | Canada |
| Model | NS/ASN Series |
| Wavelength Range | 514–1550 nm |
| Pulse Width | 0.7–1.5 ns |
| Avg. Power | 0.5–10 W |
| Cooling | Air-cooled |
| Beam Quality (M²) | <1.1 |
| Timing Jitter | <10 ps RMS |
| Trigger Mode | Internal/External TTL |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (Software Optional) |
| Brand | auniontech (Distributor) |
|---|---|
| Origin | Germany |
| Manufacturer | Cinogy GmbH |
| Model | CinCam Pico CMOS-1201-Pico |
| Sensor Type | CMOS |
| Active Area | 5.7 mm × 4.3 mm |
| Pixel Count | 2560 × 1920 |
| Pixel Size | 2.2 µm × 2.2 µm |
| Spectral Range (Standard) | 400–1150 nm |
| Optional Ranges | 150–1150 nm (UV), 240–1150 nm (OM), 320–1150 nm (RT), 400–1320 nm + 1470–1605 nm (IR) |
| Dynamic Range | 70 dB |
| Mechanical Dimensions | 15 mm × 15 mm × 11.5 mm |
| Interface | USB 2.0 |
| Mount | C-mount / F-mount compatible |
| Software | RayCi-Lite / Standard / Pro |
| Data Export Formats | TIFF, PNG, PDF, Excel, AVI, MP4 |
| Compliance | CE, RoHS, ISO 9001 manufacturing environment |
| Brand | Auniontech (Distributor) |
|---|---|
| Origin | Lithuania |
| Laser Type | Diode-Pumped Solid-State Q-Switched Laser |
| Pulse Duration | 2–5 ns |
| Repetition Rate | Up to 100 Hz |
| Pulse Energy | Up to 40 mJ (1163/1177 nm), 20 mJ (1300/1317 nm), 30 mJ (1551/1571 nm) |
| Average Power | Up to 1 W |
| Cooling | Air-Cooled |
| Pump Diode Lifetime | >2 Gshots |
| Optional Harmonic Generators | SHG, THG, FHG (H-SMART series) |
| Compliance | CE, RoHS, IEC 60825-1:2014 Class 4 Laser Product |
| Brand | Aurea Technology |
|---|---|
| Origin | France |
| Model | SPD_NIR_OEM_120MHz |
| Spectral Range | 900–1700 nm |
| Max. Trigger Rate | 120 MHz |
| Quantum Efficiency | Adjustable 5–30% (5% steps) |
| Timing Jitter | <150 ps @ 30% QE |
| Dark Count Rate | <5.0 × 10⁻⁶ per ns @ 10% QE (SMF) |
| Dead Time | Adjustable 500 ns – 999 µs |
| Cooling | Integrated Thermoelectric Cooler (TEC) |
| Interface | USB 2.0 |
| Fiber Compatibility | SMF or MMF |
| TEC Stabilization Time | <2 min @ 25 °C |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | HERA |
| Spectral Range (Lens Mode) | 380–780 nm |
| Spectral Resolution (FWHM) | 2.3 nm |
| Integration Time | 2.5 ms – 20 s |
| Stray Light | <0.03% |
| Nonlinearity | <1% |
| Luminance Range | 0.05–6000 cd/m² |
| Wavelength Accuracy | ±0.5 nm |
| Luminance Accuracy (CIE A) | ±4% |
| Chromaticity Accuracy (CIE x,y) | ±0.002 |
| Repeatability (2σ, 250 cd/m²) | <0.3% (luminance), ±0.0005 (x,y) |
| Measurement Spot Size (20 mm lens, 50 mm WD) | 20.5 mm |
| Field of View | ±0.3° |
| Interface | High-Speed USB (USBTMC/SCPI), RS232, Ethernet, External Trigger |
| Dimensions (L×W×H, body only) | 100 × 80 × 55 mm |
| Weight | 0.35 kg |
| Operating Temperature | 10–35 °C |
| Power | 1250 mW (USB-powered) |
| Optical Configurations | Fixed lens, cosine corrector, or fiber-coupled input (HERA01–HERA04 variants) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Hyperion Wide-Spectrum Series |
| Spectral Range | 200–1100 nm |
| Spectral Resolution (FWHM) | 2.3 nm |
| Integration Time | 4.8 ms – 60 min |
| Dark Noise (RMS) | ~3–5 counts (16-bit ADC) |
| Stray Light | <0.03% |
| Nonlinearity | <1% |
| Detector Cooling | Thermoelectrically cooled CCD to −10 °C |
| Optical Interface | 20 mm lens (spot size: 20.5 mm @ 50 mm WD, 21 mm @ 100 mm WD, 21.5 mm @ 150 mm WD) |
| Field of View | ±0.3° |
| Interfaces | High-Speed USB (USBTMC compliant), RS232, Ethernet, External Trigger |
| Dimensions (L×W×H) | 230 × 195 × 82.5 mm (body only) |
| Weight | 3.3 kg |
| Operating Temperature | 10–35 °C |
| Power Supply | 15 V DC (14.5–15.5 V range) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | MSE_colorimeters |
| Optical Spot Size | 10 mm (standard), 20 mm (MSE+ variant) |
| Spectral Response | CIE 1931 XYZ-matched via interference-filtered Si photodiodes |
| Measurement Speed | Up to 200 color measurements/sec @ 200 cd/m² |
| Luminance | 22,000 samples/sec |
| Dynamic Range | 0.05–3000 cd/cm² (MSE), 0.05–15,000 cd/cm² (MSE+) |
| Accuracy | Luminance Y ±0.06% (≥150 cd/m²), Chromaticity x,y ±0.0002 (≥150 cd/m², calibrated) |
| Repeatability | Y ±0.15% @ 1 cd/m² |
| Resolution | 15-bit for X,Y,Z channels |
| Integration Time | 1 ms – 5 s |
| Interface | USB 2.0, RS-232, TTL Trigger In/Out |
| Mechanical Shutter | >1 million cycles, 70–120 ms actuation |
| Operating Temperature | 10–35 °C |
| Dimensions (w/o lens) | 63 × 24 × 65 mm |
| Weight | 250 g |
| Mounting | 12× M3 threaded holes |
| Compliance | Designed for GLP/GMP-aligned manufacturing environments |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | PCM2X-271 |
| Luminance Range | 2.5×10⁻⁵ to 3×10⁴ cd/m² |
| Chromaticity Accuracy Range | 2.5×10⁻⁴ to 3×10⁴ cd/m² |
| Sampling Rate (XYZ) | 600 kS/s |
| Field of View | ±5° |
| Spot Size | 30 mm @ 25 mm Working Distance |
| CIE Standard Observer | 2° CIE 1931 & CIE 170-2:2015 |
| Flicker Analysis | FFT-based (FMA, JEITA, user-defined), time-domain FMA (VRR), FIR-filtered |
| Shutter | Mechanical, USB-MTC compliant |
| OS Compatibility | Windows, Linux, macOS |
| Software Interface | VISA, LabVIEW, LabWindows CVI, Visual Studio |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | HYPERION 2.1 mm |
| Optical Spot Size | 2.1 mm (focused lens configuration) |
| Measurement Principle | Tristimulus CIE 1931 XYZ colorimetry |
| Luminance Range | 0.001–200,000 cd/m² (typical, dependent on integration time and lens) |
| Sampling Rate | up to 2000 samples/s for Y (luminance) flicker measurement |
| Interface | USB-TMC compliant |
| Operating Systems | Windows, Linux (x86_64, i686, ARM), macOS |
| Software Integration | Native VISA support for LabVIEW, LabWindows/CVI, Visual Studio (.NET) |
| Compliance | USB-TMC 1.0, JEITA CP-3405 (flicker), CIE S 026/E:2015 (photopic luminous efficiency), ISO/CIE 11664-1:2019 (colorimetry fundamentals) |
| Mechanical Shutter | Integrated |
| Dynamic Range | >120 dB (typical, 24-bit ADC with auto-ranging) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Rhea Spectrometers |
| Spectral Range | 200–1100 nm |
| Cooling | Thermoelectrically cooled CCD (operating at –10 °C) |
| Spectral Resolution (FWHM) | 2.3 nm |
| Integration Time | 4.8 ms – 60 min |
| Dark Noise (RMS) | ~3–5 counts (16-bit ADC) |
| Stray Light | <0.03% |
| Nonlinearity | <1% |
| Optical Input | Fixed or customizable fiber coupling |
| Interface | High-speed USB (USBTMC compliant), RS232, Ethernet, TTL trigger |
| Dimensions (L×W×H) | 230 × 195 × 82.5 mm (excl. lens) |
| Weight | 3.3 kg |
| Operating Temperature | 10–35 °C |
| Power Supply | 14.5–15.5 V DC |
| Spot Size (with 20 mm lens) | 20.5 mm @ 50 mm WD, 21 mm @ 100 mm WD, 21.5 mm @ 150 mm WD |
| Field of View | ±0.3° |
| Onboard Processing | Yes |
| Neutral Density Filter Wheel | Integrated |
| Dynamic Range Enhancement | Yes |
| Linearity | Engineered for <1% nonlinearity across full intensity range |
| Compliance | USBTMC, SCPI command set, suitable for GLP/GMP-aligned data acquisition workflows |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Hyperion |
| Detection Angles | 0°, 30°, 45°, 60° |
| Spectral Response | CIE 1931-compliant XYZ tristimulus |
| Luminance Range | 0.02–20,000 cd/m² |
| Chromaticity Accuracy (x,y) | ±0.001 (post-calibration), down to ±0.0002 at 150 cd/m² |
| Flicker Measurement Speed | 2000 samples/sec (flicker mode) |
| Color Measurement Speed | ≤22 ms per acquisition |
| Dynamic Range | >80 dB |
| A/D Resolution | 16-bit (X,Y,Z) |
| Interface | USB 2.0, RS-232 |
| Operating Temperature | 10–35 °C |
| Weight | 1.5 kg |
| Dimensions (w/o lens) | 195 × 194 × 64 mm |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Asteria-Colormeters |
| Instrument Type | Benchtop Spectrocolorimeter |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Steropes LED |
| Spectral Range | 200–1100 nm |
| Repeatability | <0.5% (ΔY), 0.0002 (ΔY at low luminance) |
| Detector | Silicon Photodiode with CIE 1931 Photopic Response Matching |
| Luminance Range | 0.002–15,000 cd/m² |
| Illuminance Range | 0.01–200,000 lux |
| Sampling Rate | Up to 180,000 samples/sec |
| Internal Memory | 250,000 measurements |
| Measurement Speed | 4–100 Hz (luminance/illuminance), real-time flicker analysis |
| Operating Temperature | 10–35 °C |
| Dimensions (L×W×H) | 69×31×93 mm (body only) |
| Weight | ~0.35 kg |
| Interface | USB 2.0, RS-232 |
| Trigger Support | External TTL trigger input |
| Software Compatibility | LabVIEW, LabWindows/CVI, Visual Studio (C++, C#, VB.NET) |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Hyperion_colorimeters |
| Detector | Triple silicon photodiodes with XYZ interference filters |
| Spectral Response | CIE 1931 standard observer (close match) |
| Luminance Range | 0.005–20,000 cd/m² |
| Chromaticity Accuracy (x,y) | ±0.001 (calibrated) |
| Luminance Accuracy | ±4% of reading |
| Flicker Measurement | JEITA & Contrast methods |
| Sampling Rate | Up to 40 Hz (at ≥5 cd/m²) |
| Dynamic Range | >80 dB |
| Resolution | 16-bit for X, Y, Z |
| Integration Time | 0.5 ms – 1 s |
| Optical Field of View | 5° (±2.5°) |
| Spot Size | 13.5 mm @ 50 mm WD |
| Interface | USB 2.0, RS-232 |
| Power | USB bus-powered + optional 9 V DC |
| Dimensions (w/o lens) | 53 × 70 × 147 mm |
| Weight | 670 g |
| Operating Temperature | 10–35 °C |
| Shutter Lifetime | >1 million cycles |
| Shutter Speed | 250–300 ms |
| Color Spaces | CIE XYZ, Yxy, Yu’v’, CCT, Duv, Dominant Wavelength (DWL), Flicker (%, dB) |
| Brand | Admesy |
|---|---|
| Model | PCM2-100 |
| Measurement Principle | CIE 1931 / CIE 170-2:2015 Tristimulus Matching |
| Luminance Range | 0.0003–15,000 cd/m² (UHL Mode up to 95,000 cd/m²) |
| Chromaticity Accuracy | ±0.003 Δu'v' (typ.) |
| Luminance Accuracy | ±2% (≥0.01 cd/m²), ±5% (0.0003–0.01 cd/m²) |
| Aperture Angle | 5° (±2.5°) |
| Spot Size | 18.7 mm @ 100 mm WD |
| Sampling Rate | Up to 3125 Hz (flicker mode) |
| Interface | USB 2.0 compliant with USBTMC |
| OS Support | Windows, Linux, macOS |
| Software SDK | VISA-compatible (LabVIEW, LabWindows/CVI, Visual Studio) |
| Internal Flicker Calculation | JEITA-compliant, customizable algorithm |
| Mechanical Shutter | Integrated, TTL-controlled |
| Compliance | USBTMC 1.0, CIE S 014-2/E:2016, ISO/CIE 11664-3:2018, IEC 62341-6-3 (OLED display testing) |
| Brand | Admesy |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PCM2-051 |
| Brightness Range | 0.0003–15,000 cd/m² (UHL mode up to 95,000 cd/m²) |
| Chromaticity Range | 0.003–15,000 cd/m² |
| Measurement Spot Size | 5 mm (at 5 mm working distance ±2 mm) |
| Field of View | ±6° |
| Sampling Rate | 2000 / 3000 / 3125 Hz |
| CIE Standard Observer | 2° CIE 1931 & CIE 170-2:2015 |
| Flicker Calculation | Internal JEITA-compliant (custom algorithms supported) |
| Shutter | Mechanical, USB-MTC compliant |
| OS Compatibility | Windows, Linux, macOS |
| Software Integration | VISA-compatible for LabVIEW, LabWindows/CVI, Visual Studio |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Prometheus X27 |
| Measurement Principle | CIE 1931 / CIE 170.2:2015-compliant photopic luminance and tristimulus colorimetry |
| Luminance Range | 0.0001–20,000 cd/m² |
| Minimum Measurement Time | 1 s (at 0.0001 cd/m²) |
| Y-Channel Sampling Rates | 3.125 kS/s, 2 kS/s, or 800 kS/s |
| Filter Accuracy | Factory-calibrated interference filters matching CIE standard observer functions |
| Compliance | CIE 1931, CIE 170.2:2015, JEITA TR-006 (flicker), USB Device Class MTC v1.0 |
| OS Compatibility | Windows, Linux, macOS |
| API Support | Native SDK for C#, C++, VB.NET, LabVIEW, MATLAB, Python |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Prometheus |
| Detector Type | Cooled CCD |
| Viewfinder Type | Pritchard Mirror-Based Camera Viewfinder |
| Interface | USB (USBTMC/SCPI), RS232, Ethernet |
| Dynamic Range | High (with内置 mechanical shutter & OD filter wheel) |
| Polarization Sensitivity | Very Low |
| Linearity Error | ±0.5% (internally compensated) |
| Dark Current Compensation | Full integration-range zero offset correction |
| Wavelength Monitoring | Integrated real-time wavelength drift correction |
| Calibration | Factory-calibrated for spectral radiance, luminance, chromaticity (CIE 1931 xy, u’v’) |
| Compliance | USBTMC, SCPI, ISO/CIE-compliant measurement architecture |
| Software Support | SDK for Python, C++, LabVIEW, MATLAB, .NET |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Prometheus LF |
| Sampling Rate | 800 kS/s |
| Photopic V(λ) Filter Compliance | CIE 1931 Standard Observer |
| Flicker Metrics | Contrast Ratio (Min/Max/RMS), JEITA, VESA |
| Operating Systems | Windows, macOS, Linux |
| API Support | VISA-compliant (LabVIEW, LabWindows/CVI, C++, C#, Python) |
| Trigger I/O | TTL-compatible input/output |
| Auto-ranging | Yes |
| User Calibration | Supported |
| Memory | High-capacity onboard buffer |
| Measurement Modes | Luminance (cd/m²), Flicker Waveform Capture, Temporal Analysis |
| Optical Aperture | 17 mm |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Atlas-Colorimeters |
| Spectral Range | 380–780 nm |
| Wavelength Resolution (FWHM) | 2.3 nm |
| Camera Options | 8 MP (3312 × 2488) or 16 MP (4872 × 3248), 12-bit output |
| Nonlinearity | < 1% |
| SNR | 60 dB |
| Exposure Time | 1 ms – 16 s |
| Integral Time (Spectrometer) | 1.4 ms – 20 s |
| Stray Light | < 0.03% |
| Lens Options | Componon-S f/4.0–f/5.6, focal lengths 80–102 mm |
| Field of View (Diagonal) | 12.6°–19.2° (depending on model & working distance) |
| Compliance | ISO/CIE photopic and colorimetric standards, NIST-traceable calibration protocols |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Cronus |
| Spectral Range | 380–780 nm |
| Spectral Resolution (FWHM) | 2.3 nm |
| Integration Time | 2.5 ms – 20 s |
| Linearity Error | < 0.5% |
| Dynamic Range (Spectrometer) | >150,000 |
| Dynamic Range (Colorimeter) | >10,000,000 |
| Luminance Measurement Speed | >50,000 readings/s |
| Colorimetric Accuracy (Y, x, y) | ±4%, ±0.002 |
| Colorimetric Repeatability (Y, x, y) | <0.5%, ±0.0002 |
| Detector | Silicon photodiodes with XYZ interference filters conforming to CIE 1931 color matching functions |
| Optical Input Options | Cosine corrector (fixed or fiber-coupled), integrating spheres (75 mm / 150 mm / 250 mm), lens systems (5 mm / 10 mm / 20 mm focal lengths) |
| Interface | High-speed USB (USBTMC-compliant), RS-232, Ethernet, external trigger I/O |
| Mechanical Shutter Lifetime | >1 million cycles |
| Operating Temperature | 10–35 °C |
| Compliance | USBTMC standard, SCPI command set |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | Hyperion Series |
| Detector | Triple silicon photodiodes with XYZ interference filters |
| Spectral Response | CIE 1931-compliant |
| Weight | 670 g |
| Dimensions (w/o lens) | 53 × 70 × 147 mm |
| Mounting | 12× M3 threaded holes |
| Power Supply | USB-powered + optional 9 V DC |
| Interfaces | USB 2.0, RS-232 |
| Measurement Parameters | XYZ, Yxy, Yu’v’, CCT, DWL, Flicker (JEITA & Contrast methods) |
| Luminance Range | 0.003–12,000 cd/m² |
| Luminance Accuracy | ±2% (at 150 cd/m², white field) |
| Chromaticity Accuracy (x,y) | ±0.001 (at 150 cd/m², white field) |
| Repeatability (Y) | ±0.1% (≥5 cd/m²) |
| Chromaticity Repeatability (x,y) | ±0.0002 (≥5 cd/m²) |
| Flicker Sampling Rate | 2000 Hz (XYZ & flicker simultaneously) |
| Minimum Detectable Flicker Frequency | 1 Hz |
| Measurement Speed | Up to 40 Hz (at ≥5 cd/m²) |
| Integration Time | 0.5 ms – 1 s |
| Dynamic Range | >80 dB |
| A/D Resolution | 16-bit per channel |
| Operating Temperature | 10–35 °C |
| Shutter Lifetime | >1 million cycles |
| Shutter Actuation Time | 250–300 ms |
| Optical Configurations | Standard 5° FOV (10 mm or 20 mm lens) |
| Brand | Hinds Instruments |
|---|---|
| Origin | USA |
| Model | DV-193 |
| Wavelength Range | 180–200 nm (optimized at 193 nm) |
| Measurement Principle | Dual-PEM Modulated Photoelastic Polarimetry |
| Stokes Parameter Acquisition Rate | >100 Hz |
| Accuracy (180–200 nm) | ±1% |
| Sensitivity | <0.0005 |
| Repeatability (3σ, 180–200 nm) | ≤0.01 |
| Repeatability (3σ, 200–400 nm) | ≤0.0035 |
| PEM Resonant Frequency | 37–100 kHz |
| Compliance | ASTM E284, ISO 15382, USP <857>, GLP/GMP-ready data audit trail |
Show next