Added to wishlistRemoved from wishlist 0
Add to compare
BrandSINGER
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelRoToR HDA
Instrument TypeMicroarray Chip System
Base Dimensions (L×W×H)1150 × 480 × 800 mm
Weight110 kg
Voltage240 V
Power Consumption250–300 W
Air Supply Requirement3 L/min at 4 bar
Compatible Plate FormatsSBS-standard 96-, 384-, 768-, 1536-, 3072-, and 6144-density agar or liquid culture plates
Transfer ModesReplica plating, mating (hybridization), re-arraying, backup, and serial dilution
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELECTROTEK
OriginUnited Kingdom
ModelAW200SG
Chamber Capacity220 Petri Dishes
Transfer Lock Capacity10 Petri Dishes
Gas Mixture10% H₂ + 10% CO₂ + 80% N₂ (Anaerobic) / 5% O₂ + 10% CO₂ + 85% N₂ (Microaerophilic)
Temperature RangeAmbient +4°C to 45°C
Temp. Stability±0.5°C at 37°C
Dimensions (W×D×H)648×635×572 mm
Power Supply220 V, 50 Hz, 300 W
Humidity ControlActive Condensation-Based System with Removable Water Collection Bottle
SafetyIntegrated Earth Leakage Protection, Auto Diagnostics (Low Pressure, Leak, Airflow Anomaly)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBWB
OriginUnited Kingdom
ModelBWB FL
Detection RangeNa: 0.05–1000 ppm, K: 0.05–1000 ppm, Li: 0.1–1000 ppm, Ca: 2.5–1000 ppm, Ba: 5–1000 ppm
Detection LimitNa/K: 0.02 ppm, Li: 0.05 ppm, Ca: 1.0 ppm, Ba: 2.0 ppm
Response Time<15 s
RepeatabilityCV <1% at 100 ppm (n=20, >10 min post-stabilization)
Sample Uptake Rate3.0–5.5 mL/min
Air SupplyIntegrated silent air compressor (switchable to external source)
ComplianceCE-marked, GLP-compliant architecture, FDA 21 CFR Part 11-ready software support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBWB
OriginUnited Kingdom
ModelFL
Detection RangeNa: 0.1–1000 ppm
K0.05–1000 ppm
Li0.1–1000 ppm
Ca2.5–1000 ppm
Detection LimitNa/K: 0.02 ppm
Li0.05 ppm
Ca1.0 ppm
Response Time<15 s
Repeatability<1% RSD (at ≤100 ppm, n=20 over 10 min)
Sample Uptake Rate3.0–5.5 mL/min
Air SupplyIntegrated silent air compressor (switchable to external source)
ComplianceCE-marked
Data InterfacesRS232 and USB
Calibration ModesTwo-point, multi-point, and multi-ion calibration
Display Unitsppm, mg/L, mmol/L, meq/L
Safety FeaturesFlame-out detection, auto-shutdown, power-on self-diagnosis
Added to wishlistRemoved from wishlist 0
Add to compare
OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTRIO.BAS DUO
Price RangeUSD 6,800 – 13,600 (FOB)
Sampling PrincipleIsokinetic Impaction via Precision Laser-Drilled Stainless Steel Nozzle Array
Flow Rate200 L/min (selectable 100/200 L/min)
Flow Accuracy±2.5% of reading
Sampling Duration0–10 min (programmable in segments)
Operating Temperature−10 °C to +40 °C
Operating Relative Humidity0–80 % RH
Sample Dish Compatibility60 mm and 90 mm Petri Dishes
DisplayBacklit LCD (32 × 64 mm)
Control Interface4 Membrane Waterproof Keys
Wireless ConnectivityIntegrated Bluetooth 5.0
Power SupplyRechargeable Ni-MH Battery (12 V, 4500 mAh)
Charging InputAC 100–240 V, 50/60 Hz
USB Charging Port5 V, 500 mA
Weight1.9 kg (main unit only)
Dimensions260 × 280 × 140 mm
CertificationsCE (EN 61010-1:2010, EN 61326-1:2006, EN 62321:2009), ATEX II 2G Ex eb IIB T4 Gb (EN 60079-0:2012, IEC 60079-15:2010)
Data Integrity ComplianceFDA 21 CFR Part 11–ready audit trail & electronic signature support
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAW 500SG
Price RangeUSD 13,500–67,500 (est.)
Temperature Control RangeAmbient +4°C to 42°C
Temperature Uniformity & Stability±0.5°C at 37°C
Humidity Range30–100% RH
Chamber Capacity500 Petri Dishes
Transfer Lock Capacity60 Petri Dishes
Gas Supply OptionsSingle-gas (10% H₂ + 10% CO₂ + 80% N₂) or Dual-gas (premixed + pure N₂)
External Dimensions (W×D×H)1473 × 700 × 667 mm
Power Supply220 V, 50 Hz, 500 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSINGER
OriginUnited Kingdom
ModelPIXL
Dimensions (L×W×H)718 × 630 × 810 mm
Weight70 kg
Power Supply240 V, 10 A (2400 W)
ThroughputUp to 130 microplates per hour
Supported Plate Formats96-well, 384-well, 1536-well SBS-compliant plates, Petri dishes, shallow/deep well plates, agar plates
Picking ModesLiquid-to-liquid, liquid-to-agar, agar-to-liquid
SterilizationIntegrated UV lamp + anti-contamination front shield
ImagingHigh-resolution static/dynamic colony morphology analysis
Fluorescence CapabilityMulti-channel fluorescence module for GFP/RFP/mCherry and other standard fluorophores
Software InterfaceGraphical user interface (GUI) with drag-and-drop workflow configuration
External IntegrationAPI-enabled for LIMS, robotic arms, and third-party liquid handlers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPunmicro
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelPunmicro Anaero Mark
Instrument TypeAutomated Anaerobic Incubator
O₂ Concentration Range0–21% (adjustable in 0.1% increments)
CO₂ Concentration Range0–20% (adjustable in 0.1% increments)
Chamber Volumes1.35 L / 2.5 L / 2.75 L / 3 L / 6 L / 7 L / 10 L / 15 L (user-selectable)
Temperature RangeAmbient +5°C to 70°C
Temperature Uniformity±0.5°C
Max Working Pressure≥1.5 bar
CatalystRegenerable Palladium-Based Hydrogen Catalyst (O₂ < 5 ppm)
Gas Interface3 gas cylinder ports + 4 incubation chamber ports + 1 reserved port
Vacuum PumpOil-free
Gas Consumption~2 L per 12×90 mm plates (microaerophilic)
Self-Test Duration≤5 s at power-on
Program Switching Time≤10 s
Anaerobic Condition Establishment<3 min
Microaerophilic Condition Establishment<1 min
Pre-reduction Module Capacity≥10×90 mm plates
Data TraceabilityBuilt-in thermal printer + optional data export module
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBWB
OriginUnited Kingdom
ModelBWB-XP
Detection ElementsNa, K, Li, Ca, Ba
Calibration ModesTwo-point, Multi-point, Multi-ion
Output Options0–1 V analog, RS232, USB
Air SupplyIntegrated silent air compressor (switchable to external source)
Sample Uptake Rate3.0–5.5 mL/min
RepeatabilityCV <1% at ≤100 ppm over 20 injections (≥10 min post-stabilization)
Detection LimitsNa/K: 0.02 ppm
Li0.05 ppm
Ca1.0 ppm
Ba10 ppm
Linear Range (multi-point)Na/K: 0.05–1000 ppm
Li0.1–1000 ppm
Ca2.5–1000 ppm
Ba30–3000 ppm
Response Time<15 s (from sample introduction to stable signal)
Drift≤1% after 30 min stabilization
Interference (Na/K/Li at <100 ppm)<0.5%
Display ModeReal-time simultaneous readout of all five elements (ranked high-to-low)
SoftwareFP-PC v3.x with GLP-compliant reporting, audit trail, data export (up to 10-sample reports), operator/sample metadata tagging, network archiving
ComplianceCE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINLABTEC
OriginSwitzerland
ModelSerial Diluter TA
Pipette Range0–10 mL (graduated standard pipettes)
Accuracy±0.05 mL at 1 mL
Tube Diameter CompatibilityØ8–15 mm
Tube Length Compatibility150–350 mm
Liquid Level DetectionCapacitive sensor-based
Pumping Error≤0.6% (≤±54 µL at 9 mL)
Pump Speed Control25–99% adjustable
Mixing TimeAuto-optimized or manually set from 0.5–99 s
Sterilizable Dilution Bag Holder316 stainless steel, autoclavable
Max. Bag Capacity6 bags
Compatible DiluentsAqueous solutions only (non-strongly acidic/basic, non-organic)
Self-Diagnostic AlertsEmpty reagent bottle detection, full pipette tip overflow detection, audible + visual alarm
Dimensions (main unit)175 × 180 × 480 mm (W×D×H)
Bag Holder Dimensions433 × 165 × 170 mm (W×D×H)
Environmental Operating Range10–40 °C, RH ≤80% @ 31 °C
Power Supply100–240 V ±10%, 50–60 Hz ±10%, 18 W
Contamination Protection ClassIP20 (IEC 60529)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPUNMICRO
ModelICON
TypeFully Automated Colony Counter
Counting SpeedFull-Petri-Dish Counting in 3 Seconds
Imaging System4K Color CCD Camera (20 MP), Auto-Zoom & Auto-Focus
Data TransferGigabit Ethernet (1000 Mbps)
Sample ChamberLight-Tight Enclosure
IlluminationTop LED Machine-Vision Light Source + Bottom Diffused LED Light Source + Optional 365 nm UV Fluorescence Source
Processor ArchitectureAviation-Grade Chipset
SoftwarePM-Suit Colony Analysis Suite with Built-in Swiss Sanitized® Reference Colony Library
Security & ComplianceThree-Tier User Permission System, Audit Trail, ALCOA+ Data Integrity Support, Cluster Networking Capability
Optional AccessoryBarcode Scanner
Dimensions (W×H×D)300 × 470 × 290 mm
Weight~11 kg
Power Supply100–240 V AC, 50–60 Hz, 60 W
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAW 400SG
Price RangeUSD 13,500–67,500 (est.)
Temperature RangeAmbient + 4°C to 42°C
Temperature Uniformity & Stability±0.5°C at 37°C
Humidity Range30–100% RH
Chamber Capacity400 Petri Dishes
Transfer Lock Capacity60 Petri Dishes
Gas Supply OptionsSingle-gas (10% H₂ + 10% CO₂ + 80% N₂) or Dual-gas (premixed + pure N₂)
External Dimensions (W×D×H)1283 × 700 × 667 mm
Power Supply220 V, 50 Hz, 500 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPUNMICRO
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelIPAN
Oxygen Concentration Range0–21% (operational anaerobic range: ≤5 ppm O₂)
Temperature Control RangeAmbient +4°C to 48°C
Temperature Uniformity & Stability±0.5°C
Temperature Accuracy±0.1°C
Humidity Range0–100% RH (controlled via precision condensation dehumidification)
Gas Supply ConfigurationDual-gas system (high-purity N₂ + anaerobic gas mixture: 80% N₂ / 10% CO₂ / 10% H₂)
Chamber Volume480 L
Transfer Lock Capacity60 standard Petri dishes
Sample Capacity500–810 × 90 mm Petri dishes or 90 × 250 mL Erlenmeyer flasks
LightingAdjustable monochromatic LED system (625 nm red / 470 nm blue / 525 nm green
Internal IlluminationDiffuse LED, 300 lux
Viewing Window7° ergonomic tilt angle
Chamber MaterialNPL-UV specialty polymer with long-term pressure-tight integrity
Safety SystemsLeak self-diagnostic with automatic gas cutoff, marine-grade arc-resistant circuitry, explosion-proof heating elements, arc-resistant internal power sockets
Pressure ManagementPneumatic auto-depressurization system with water-level monitoring and alarm
Catalyst ModuleSuper-Pd oxygen scavenger (maintenance-free, no baking required)
DecontaminationUV-C (254 nm) lamp + integrated alcohol spray bottle + compatibility with NaOCl, H₂O₂ vapor, and ethanol protocols
Oxygen SensorIn-situ ppm-grade electrochemical sensor, resolution 1 ppm, display on dual-layer ITO touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELECTROTEK
OriginUnited Kingdom
ModelAW 300SG
Incubation Temperature Range+4 °C to 48 °C
Temperature Uniformity & Stability±0.5 °C
Humidity Range35–100 % RH
Chamber Capacity300 Petri Dishes
Transfer Lock Capacity10 Petri Dishes
Gas SystemSingle-Cylinder Mixed-Gas (N₂/H₂/CO₂) with Integrated Catalyst
Anaerobic VerificationANO2 Indicator System with Chemical Reagent
ConstructionAcrylic-Modified Polypropylene Housing with Condensation-Resistant Viewing Panels
Control SystemMicroprocessor-Based with Programmable Temperature & Humidity Profiles
Safety AlarmsLeak Detection, Low Gas Pressure, Catalyst Exhaustion, and Environmental Deviation Alerts
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSinger
OriginUnited Kingdom
ModelMSM 400
CategoryLife Science Instrument / Microbiology Detection Instrument / Yeast Inoculator
Manufacturer TypeAuthorized Distributor
Origin ClassificationImported
PricingAvailable Upon Request