Ultra Pure Water System
Filter
Showing 151–180 of 372 results
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | CYPAKKITEX |
| Pricing | Available Upon Request |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CYPAKKIT00 |
| Pricing | Available Upon Request |
| Brand | ELGA Veolia |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MEDICA–R 200 |
| Purified Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Resistivity | 10–18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <10 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particulates (>0.1 µm) | <0.2 µm per mL |
| Flow Rate | 18–30 L/min (distribution network) |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | Aquinity |
| Pure Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count | <0.1 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Flow Rate | 1.8 L/min |
| Production Capacity | 3 / 7 / 10 L/h |
| Recovery Rate | 35% |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Aquintus Mid-Size |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 3 ppb |
| Microbial Count | < 1 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (> 0.1 µm) | < 1 particle/mL |
| Daily Output Capacity | 100 L/day |
| Feed Water Compatibility | Secondary RO water, deionized water, or EDI-produced high-purity water |
| Flow Rate (Standard/Analytical) | 1.5 L/min |
| Flow Rate (Life Science Variant) | 1.0 L/min |
| Feed Conductivity Monitoring | Integrated real-time conductivity sensor with alarm threshold control |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer | membraPure GmbH |
| Product Type | Imported Laboratory Ultra-Pure Water System |
| Model | EDI Compact |
| Pure Water Grade | ASTM Type II |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 3 ppb |
| Microbial Count | < 10 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Conductivity | < 1.0 µS/cm |
| Flow Rate Range | 5–330 L/h |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model Series | EDI-5, EDI-10, EDI-20, EDI-40, EDI-55, EDI-75, EDI-120, EDI-180, EDI-260, EDI-310 |
| Output Flow Rate | 5–310 L/h |
| Resistivity | ≥18.2 MΩ·cm (at 25 °C) |
| Conductivity | ≤0.5 µS/cm (Nankai University validation: 0.07–0.1 µS/cm) |
| Total Organic Carbon (TOC) | <10 ppb |
| Feed Water Requirement | Municipal tap water (pre-treated via integrated RO) |
| Configuration Options | Standalone or Centralized Distribution System |
| Regeneration | Fully automatic, continuous electrochemical regeneration — no chemical reagents or cartridge replacement required |
| Compliance | Designed to meet ASTM D1193 Type I, ISO 3696 Grade 1, and CLSI EP21-A2 specifications for clinical and research-grade ultrapure water |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Milli-Q Advantage A10 |
| Purified Water Grade | Type I (ASTM D1193-22) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | ≤5 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particles/mL |
| [Brand | Merck |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Ultra-Pure Water System |
| Model | Elix® Essential |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm @ 25 °C (typical 10–15 MΩ·cm @ 25 °C) |
| Conductivity | <0.2 µS/cm @ 25 °C (typical 0.067–0.1 µS/cm @ 25 °C) |
| TOC | <30 ppb (typical) |
| Microbial Count | <10 CFU/mL (with optional UV lamp) |
| Endotoxin | <0.001 EU/mL (with terminal 0.22 µm filter) |
| Particles (>0.1 µm) | <1 particle/mL |
| Flow Rate | 3–15 L/h (selectable) |
| Operating Ambient | 5–35 °C, 20–80% RH |
| Power Supply | 100–230 V AC ±10%, 50–60 Hz |
| Feed Water Pressure | 0.5–6 bar] |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Milli-Q Integral |
| Pure Water Grade | Type II |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 5 ppb |
| Microbial Count | < 0.1 CFU/mL |
| Endotoxins | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Pure Water Flow Rate | 3–15 L/h |
| Ultra-Pure Water Flow Rate | 2 L/min |
| Silicon Rejection Rate | >99.9% |
| TOC in Pure Water Output | <30 ppb |
| Brand | Merck |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IPAK Gard® |
| Pricing | Available Upon Request |
| Purified Water Grade | Type I (Ultra-Pure Water) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 5 ppb |
| Microbial Count / Endotoxins | < 0.001 EU/mL |
| Particles (> 0.1 µm) | < 1 particle/mL |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Milli-Q IQ 7000 |
| Pure Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 2 ppb (typical ≤ 5 ppb) |
| Microbial Count | < 0.001 CFU/mL |
| Endotoxins | < 0.001 EU/mL |
| Particles (>0.1 µm) | Zero particles > 0.22 µm per 100 mL |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Milli-Q Reference |
| Price Range | USD 13,500 – 40,500 (est.) |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 5 ppb (µg/L) |
| Microbial Count | < 0.1 CFU/mL |
| Endotoxins | < 0.001 EU/mL (pyrogen-free) |
| Particles (>0.1 µm) | < 1 particle/mL |
| RNase | < 1 pg/mL (with BioPak) |
| DNase | < 5 pg/mL (with BioPak) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | EQ7000 |
| Water Grade | Type I (ASTM D1193-22, ISO 3696:1987, CLSI EP28-A3c) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | ≤ 5 ppb |
| Endotoxins | < 0.001 EU/mL |
| Microbial Count | < 1 CFU/100 mL |
| Particulates (>0.22 µm) | Not Detectable |
| Flow Rate | Up to 2 L/min (Q-POD® arm, three manual settings) |
| Display | 7-inch color touchscreen interface |
| Connectivity | Ethernet (DHCP/fixed IP), USB data export |
| Terminal Purifier Compatibility | Millipak®, Millipak® Gold, Biopak®, EDS-Pak®, LC-Pak®, VOC-Pak® |
| Compliance | Meets or exceeds ASTM, ISO, CLSI, and USP <1231> specifications for purified water and water for injection (WFI)-grade applications when paired with appropriate POD-Pak® modules |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | IX7003 / IX7005 / IX7010 / IX7015 |
| Purified Water Grade | ASTM Type II |
| Resistivity | >5 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <1 ppb |
| Total Organic Carbon (TOC) | ≤30 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Merck Milli-Q |
|---|---|
| Origin | France |
| Manufacturer | Merck KGaA |
| Product Type | Imported OEM Cartridge |
| Model | Milli-Q Q-GARD Purification Cartridge |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particles/mL |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | Direct-Q3 |
| Pure Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Ultrapure Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | < 10 ppb (without UV), < 5 ppb (with optional 185/254 nm dual-wavelength UV lamp) |
| Endotoxins | < 0.001 EU/mL |
| Microbial Count | < 1 CFU/mL |
| Particles (>0.22 µm) | < 1 particle/mL |
| Flow Rate (Ultrapure) | ≥ 0.5 L/min (up to 30 L/hr) |
| Flow Rate (Pure) | ≥ 3 L/hr |
| Internal Reservoir | 6 L (RO water) |
| Conductivity Sensor Electrode Constant | 0.01 cm⁻¹ |
| Temperature Compensation Accuracy | ±0.1 °C |
| Brand | Merck |
|---|---|
| Origin | France |
| Model | Direct-Q5 |
| Pure Water Grade | Type III (ASTM D1193-06) |
| Ultrapure Water Grade | Type I (ASTM D1193-06, ISO 3696 Class 1, CLSI EP21-A) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| TOC | < 5 ppb (with 185/254 nm UV lamp) |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Microbial Count | < 1 CFU/mL |
| Endotoxins | < 0.001 EU/mL |
| Particles (>0.22 µm) | < 1/mL |
| Flow Rate (Ultrapure) | ≥ 0.5 L/min (up to 30 L/hr) |
| Flow Rate (Pure) | ≥ 5 L/hr |
| UV Lamp | Dual-wavelength 185/254 nm |
| Terminal Filtration Options | Millipak® Express 20 (0.22 µm), BioPak® UF (for endotoxin/RNase/DNase removal) |
| Reservoir Compatibility | Optional 30 L or 60 L integrated tank |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Elix Advantage |
| Price Range | USD 6,500 – 13,000 (est.) |
| Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Optional Tank Capacities | 30 L, 60 L, 100 L |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Elix Intelligent Pure Water Module |
| Price Range | USD 13,500 – 40,500 (est.) |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >10 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb (<10 ppb with optional UV-oxidation module) |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | Elix Reference |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Contamination | <10 CFU/mL (with optional UV lamp) |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | Elix Reference 3 / 5 / 10 / 15 |
| Purified Water Grade | ASTM D1193 Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm (at 25 °C) |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Contamination | <0.25 CFU/mL |
| Heavy Metals & Soluble Silica | Compliant per ISO 3696 and ASTM D1193 |
| Particulates (>0.1 µm) | Not specified |
| Feed Water | Municipal tap water |
| Storage Tank Options | 30 L / 60 L / 100 L (PE, cylindrical with conical bottom, CO₂-absorbing air filter) |
| Data Logging | 1-year automatic水质 history |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | Milli-Q IQ7000 |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <2 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Merck Millipore |
|---|---|
| Origin | France |
| Model | RiOs 30 |
| Feed Water Requirement | Municipal tap water or pretreated water |
| Resistivity | >10 MΩ·cm (at 25°C) |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <0.001 CFU/mL |
| Particles (>0.1 µm) | <1/mL |
| Purification Grade | ASTM Type III Reagent Water |
| Compliance | Meets ISO 3696:1987, CLSI EP21-A, and USP <1231> for purified water |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | RiOs Smart Pure Water Module |
| Price Range | USD 13,500 – 40,500 (based on configuration) |
| Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >10 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb (optional <10 ppb with UV oxidation module) |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Simplicity |
| Quotation Range | USD 6,800 – 13,600 (est.) |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particles/mL |
| Flow Rate | >0.5 L/min |
| Integrated Reservoir | 2 L |
| UV Option | Dual-wavelength (185 nm + 254 nm) lamp available for TOC reduction |
| Final Filtration | Optional BioPak ultrafiltration cartridge (sterile, pyrogen-free, nuclease-free output) |
| Brand | MICHEM |
|---|---|
| Model | MW-D10 / MW-D20 / MW-D30 / MW-D50 |
| Origin | Beijing, China |
| Production Capacity | 10–50 L/h |
| Feed Water | Municipal tap water (TDS < 360 ppm, pressure > 0.2 MPa) |
| Pure Water Resistivity | 1–5 µS/cm |
| Ultra-Pure Water Resistivity | 10–18.25 MΩ·cm @ 25 °C |
| Conductivity Sensor | 0.01 cm⁻¹ stainless steel electrode, ±0.1 °C temp. compensation |
| Optional Terminal Filtration | Sartorius 0.22 µm filter |
| Power Supply | AC 220 V / 50 Hz / 5 A |
| Noise Level | < 20 dB(A) |
| Certifications | Compliant with GB/T 6682–2008, ASTM D1193–20, CLSI EP22-A, and NSF/ANSI 61 components |
| Brand | MICHEM |
|---|---|
| Model | MW-D10 / MW-D20 / MW-D30 / MW-D50 |
| Production Origin | Beijing, China |
| Purification Technology | Integrated Reverse Osmosis + Dual-Stage Deionization + UV Oxidation + 0.22 µm Final Filtration |
| Conductivity of Pure Water Output | 1–5 µS/cm |
| Resistivity of Ultrapure Water Output | 10–18.25 MΩ·cm @ 25 °C |
| Feed Water Requirement | Municipal tap water, TDS < 360 ppm, pressure > 0.2 MPa |
| Power Supply | AC 220 V / 50 Hz / 5 A |
| Noise Level | < 20 dB(A) |
| Dimensions (W×D×H mm) | 440×555×700 (MW-D10/D20) |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model Series | MW-150D, MW-1T, MW-1.5T, MW-2T |
| Resistivity | 18.25 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 10 ppb |
| Microbial Count | < 1 CFU/mL |
| Endotoxin Level | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Output Flow Rate | 150 L/h to 2000 L/h (model-dependent) |
| Feed Water | Municipal tap water (TDS < 360 ppm, pressure > 0.2 MPa) |
| Compliance | GB/T 6682–2008 Grade I, ASTM D1193–20, NCCLS EP21-A, CAP Laboratory Standards |
| Brand | MICHEM |
|---|---|
| Origin | Beijing, China |
| Model | MW-D10 |
| Pure Water Grade | Type I (GB/T 6682) |
| Resistivity | 18.25 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | ≤ 10 ppb |
| Microbial Count | < 1 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |