| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A160WE |
| Price | Upon Request |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | GL-1000 |
| Instrument Type | Benchtop |
| Wavelength Type | Single Wavelength |
| Blue Light Peak Emission | 470 nm |
| Excitation Area | 100 × 150 mm |
| Illumination Source | 108 high-output, long-life LEDs |
| Filter Cover | Full-size transparent acrylic filter lid |
| Power Input | DC 24 V via external adapter |
| Dimensions (W×D×H) | 210 × 210 × 30 mm |
| Net Weight | 1.3 kg |
| LED Lifetime | ≥10,000 hours |
| Compliance | CE-marked, RoHS-compliant, GLP-supportive design |
| Brand | Kylin-Bell |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GL-312 |
| Instrument Type | Benchtop |
| Wavelength Type | Single Wavelength |
| UV Wavelength | 312 nm |
| Number of UV Lamps | 6 |
| UV Filter Size | 200 × 150 mm |
| UV Transillumination Area | 200 × 150 mm |
| UV Lamp Specification | 312 nm, 8 W each |
| Total Power Consumption | 48 W |
| Input Voltage | AC 220 V |
| External Dimensions | 420 × 300 × 65 mm |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | UV-2000F |
| Instrument Type | Benchtop |
| Wavelength Range | 250–450 nm |
| Optical Resolution | ±1 nm |
| Measurement Area | 0.67 cm² |
| Dynamic Range | 2.7 AU |
| Light Source | Pulsed Xenon Flash Lamp |
| Detector | Custom Concave Holographic Grating Diode Array Spectrometer |
| Compliance Standards | AS/NZS 4399:2017, EN 13758-1:2007, AATCC TM183-2014, GB/T 18830:2009, JIS L 1096 & JIS L 1925 |
| Software Platform | Windows XP/7 Compatible, FDA 21 CFR Part 11–Ready Audit Trail Mode (Optional), GLP/GMP-Compliant Reporting |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | UV-2000S |
| Instrument Type | Benchtop |
| Wavelength Range | 250–450 nm |
| Measurement Speed | <5 seconds per sample |
| Compliance | COLIPA UVA-PF, ISO 24443:2012, FDA 2011 Sunscreen Final Rule, Revised Boots Star Rating |
| Optical Configuration | Double-beam spectrophotometric transmittance system with integrating sphere detection |
| Sample Platform | Manual precision XYZ stage with pre- and post-irradiation baseline capture |
| Calibration Standards | NIST-traceable wavelength and transmittance standards covering six critical UV bands |
| Software | UV-2000S Control & Analysis Suite (v5.x) with 21 CFR Part 11-compliant audit trail and electronic signature support |
| Ozone Generation | None |
| Fluorescence Interference Rejection | Enabled via spectral deconvolution algorithm |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | UV2000 |
| Instrument Type | Benchtop |
| Wavelength Range | 250–450 nm |
| Light Source | Pulsed Xenon Lamp |
| Detector | High-Performance Diode Array Spectrometer |
| Optical Integration | Spectralon® Integrating Sphere |
| Wavelength Accuracy | ±1 nm |
| Measurement Time | <5 s per sample |
| UV Band Calculation | UVA (315–400 nm), UVB (280–315 nm) |
| Compliance Standards | AS/NZS 4399:1996, EN 13758-1:2001, AATCC TM 183-2000, ISO 17166:2019, GB/T 18830, CIE S107/E |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Benchtop |
| Blue Light Wavelength | 470 nm |
| Filter Type | Magnetic Amber Filter |
| UV Filter Dimensions | 18 × 20.5 × 2.2 cm |
| Transillumination Area | 15 × 15 cm |
| Power Consumption | 20 W |
| LED Lifetime | ≥30,000 h |
| Uniformity | ≥90% |
| Brightness Control | Continuous Rotary Adjustment |
| Input Voltage | AC 200–240 V |
| Housing Dimensions (L×W×H) | 19 × 20.5 × 1.5 cm |
| Max Gel Cutting Area | 15 × 15 cm |
| Filter–Housing Design | Removable for Cleaning |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | MB99-1 |
| Price | USD 2,850 (FOB Shanghai) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | MD99-2 |
| Price | USD 3,450 (FOB Shanghai) |
| UV Wavelengths | 220, 254, 280, 340 nm |
| Timer Range | 1 s – 9999 min |
| Flow Rate | 0.1–10 mL/min |
| Drop Counting Range | 1–9999 drops |
| Fraction Capacity | 12 mL × 100 tubes |
| Data Interface | USB 2.0 |
| Software Compatibility | Windows 10/11 (64-bit), .CSV/.TXT export |
| Brand | PacificImage |
|---|---|
| Model | UV TI2621D |
| Type | Darkroom-style transilluminator |
| Wavelength Options | 302 nm and 365 nm |
| UV Filter Area | 21 × 26 cm |
| UV Lamps | 8 W × 5 (302 nm) + 8 W × 6 (365 nm) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Operating Frequency | 40 kHz |
| Illumination Method | Transillumination |
| Intensity Control | High/Low dual-level adjustment |
| UV Protective Shield | Integrated acrylic shield with interlock safety design |
| Dimensions (W×H×D) | 340 × 255 × 94 mm |
| Weight | 4.0 kg |
| Certifications | CE, FCC |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6D |
| Price | Upon Request |
| Spectral Response | 250–400 nm (ACGIH SWF-weighted) |
| Field of View | 60° |
| Display Range | 0.03–10.00 hours |
| Operating Temperature | 0–40°C |
| Power Supply | 9V alkaline battery (200-hour typical life) |
| Dimensions | 15 × 8 × 3.8 cm |
| Weight | 200 g |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Model 511 |
| Pricing | Upon Request |
| Spectral Range | 280–400 nm |
| Measurement Range | 0–16 UV Index |
| Angular Response | Within ±5% of ideal cosine response for incident angles < 70° |
| Operating Temperature | −30 to +55 °C |
| Environmental Rating | NEMA 4X |
| Display | Five-color LED array (Green → Red) |
| Sensor Type | Erythemally Weighted Photodiode |
| Calibration Interval | Every 24 months |
| Power Supply | 110 VAC, 60 Hz input |
| Sensor Cable Standard Length | 10 m (extendable) |
| Enclosure Dimensions | 61 cm H × 28 cm W × 18 cm D |
| Weight | 4.5 kg (10 lbs) |
| Power Cord Length | 30 m |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | SL-3201 |
| Instrument Type | Portable Radiometer |
| Wavelength Capability | Multi-band (UV-B & UVC) |
| UV-B Range | 0–19.99 MED/h |
| UVC Range | 0–19.99 mW/cm² |
| Resolution | 0.01 MED/h or mW/cm² |
| Accuracy | ±0.2% FS |
| Nonlinearity | ≤0.02% FS |
| Temperature Coefficient | ≤50 ppm/°C |
| Operating Temp | 0–50°C (instrument) |
| Power | 4×AA NiCd/alkaline or 9–12 V DC/AC adapter |
| Weight | 480 g |
| Dimensions | 10 × 19.5 × 4.5 cm |
| UV-B Detector Spectral Response | 280–320 nm |
| UVC Detector Spectral Response | 275–285 nm |
| Cosine Error | ±5% (0–60°) |
| Data Logging | Internal memory with PC export (CSV/Excel-compatible) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | SPF601 |
| Spectral Range | 290–400 nm (UVA + UVB) |
| Output Configuration | Six independent 8-mm square irradiation ports |
| Irradiance Control | Individual manual knob per port + optional XPS-300 programmable power supply |
| Maximum Irradiance | Up to 4 MED/min per port |
| Solar Simulation Fidelity | >90% spectral match to CIE Reference Solar Spectrum (ISO 17166:2019/Erythema Action Spectrum) |
| Mechanical Positioning | Integrated precision locking gooseneck arm with UV-stable optical coupling |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-1 |
| Wavelengths | 254 nm and 365 nm |
| Type | Portable (handheld) |
| Wavelength Configuration | Dual-band UV |
| Compliance | CE-marked for laboratory use |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Safety Features | UV-blocking acrylic shield, automatic shutoff timer (optional), thermal protection circuit |
| Certifications | ISO 9001 manufacturing quality system |
| Intended Use | Non-clinical laboratory fluorescence visualization and documentation |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-20C / ZF-20D |
| UV Wavelengths | 254 nm & 365 nm (dual-band, independently switchable) |
| UV Lamp Configuration | 2 × 6 W @ 254 nm + 2 × 6 W @ 365 nm |
| Filter Dimensions | 150 mm × 70 mm |
| Filter UV Transmission | ≥20% at designated wavelengths |
| Input Voltage | AC 220 V, 50 Hz |
| Power Consumption | ≤22 W (total) |
| Lamp Lifetime | ≈500 h |
| Enclosure Type | Fully enclosed darkroom with integrated electronic ballast ignition |
| Portability | Benchtop portable design (hand-carried form factor) |
| Compliance | Designed for laboratory-grade qualitative fluorescence visualization in accordance with standard molecular biology workflows |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model Variants | ZF-7A (254 nm + 365 nm), ZF-7B (365 nm only), ZF-7C (254 nm only), ZF-7D (310 nm only) |
| Input Voltage | 220 V AC, 50 Hz |
| Rated Power | 16 W |
| UV Filter Dimensions | 50 mm × 150 mm |
| UV Lamp Quantity | 16 lamps |
| UV Wavelength Options | 254 nm, 310 nm, 365 nm |
| Device Form Factor | Handheld / Portable |
| Compliance | CE-marked for laboratory use, conforms to IEC 61010-1 safety standards for electrical equipment for measurement, control, and laboratory use |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | UVJLY-1 |
| Price | ¥12,800 |
| Instrument Type | Benchtop |
| Wavelength Options | 254 nm (standard), optional 312 nm and 365 nm |
| UV Lamp Configuration | Five 10 W low-pressure mercury lamps |
| Total Power Consumption | 60 W |
| Exposure Time Range | 0–999.9 min |
| Energy Dose Range | 0–99.99 J/cm² |
| Exposure Chamber Dimensions | 34 × 26 × 15 cm |
| External Dimensions | 36 × 34 × 31 cm |
| Display | Backlit Chinese LCD with non-volatile memory |
| Control Interface | Touch-sensitive keypad with UV-blocking viewing window |
| Chamber Material | Stainless steel |