BrandELTRA
OriginGermany
ModelON-p
Instrument TypeOxygen and Nitrogen Analyzer
Analysis Range0.1 ppm – 2%
Analysis Time90 s
Detection Limit (N)0.01 ppm
Furnace Max Temperature3000 °C
Furnace Power8.5 kW
Detection PrincipleInert Gas Fusion Coupled with IR Absorption (O) and Thermal Conductivity (N)
Carrier Gas OptionsHe or Ar
SoftwareELTRA Analytical Software (Supports CFR 21 Part 11 Compliance, Audit Trail, Multi-Point Calibration, Report Export, Comment Annotation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelH-500
Instrument TypeHydrogen Analyzer
Analysis Range (Low-H)0.1 ppm – 200 ppm
Analysis Range (High-H)10 ppm – 2%
Accuracy (Low-H)±0.1 ppm or ±1%
Accuracy (High-H)±2 ppm or ±1%
Sensitivity (H)0.01 ppm
Analysis Time2–3 min
Maximum Sample Mass10 g
Sample Dimensions≤ 0.8 × 6 cm
Furnace Max Temperature1000 °C (1 °C adjustable)
Carrier GasHigh-purity N₂
Detector ConfigurationDual thermal conductivity cells with differential sensitivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelOH-p 2
Instrument TypeOxygen/Hydrogen Analyzer
Analysis Time120–180 s
Pulse Furnace PowerUp to 8,500 W
Detection PrincipleNon-Dispersive Infrared (NDIR) for Oxygen, Thermal Conductivity Detection (TCD) for Hydrogen
Sample Form CompatibilitySolid rods, granules, powders
Max. Sample Weight2 g
Compliant StandardsASTM E1019, DIN EN 3976
Carrier Gas OptionsArgon (economical), Helium
OptionalAutomatic Graphite Crucible Cleaner
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelOH-p
Instrument TypeOxygen/Hydrogen Analyzer
Analysis RangeOxygen 0.1 ppm – 2.0 wt%, Hydrogen 0.01 ppm – 1000 ppm
Analysis TimeOxygen 85 s, Hydrogen 100 s
Furnace Max Temperature3000 °C
Furnace Power8.5 kW
Detection PrincipleInert Gas Fusion Coupled with IR Absorption (O) and Thermal Conductivity Detection (H)
Sample FormSolid, granular, or chip-shaped inorganic materials (e.g., metals, ceramics, refractories)
CalibrationSingle-point and multi-point linear regression
Cooling OptionsTap water, recirculating chiller, or heat exchanger
Compliance SupportASTM E1019, ISO 14284, ISO 22371, USP <232>/<233>, GLP/GMP-ready data audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelON-p 2
Analysis Time120–180 s
Pulse Furnace PowerUp to 8.5 kW
Maximum Furnace Temperature3000 °C
Sample Weight CapacityUp to 2000 mg
Detection PrincipleNon-Dispersive Infrared (NDIR) for Oxygen, Thermal Conductivity Detection (TCD) for Nitrogen
ComplianceASTM E1019, DIN EN 3976
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelELEMENTRAC ONH-p 2
Analysis ElementsOxygen, Nitrogen, Hydrogen
Analysis RangeO: 0.1 ppm–2.0 wt%
N0.1 ppm–2.0 wt%
H0.01 ppm–1000 ppm
Detection LimitsO: 0.1 ppm
N0.1 ppm
H0.01 ppm
Analysis Time120–180 s (typical)
Pulse Furnace Powerup to 8.5 kW
Maximum Furnace Temperature3000 °C
Detection PrincipleO by Non-Dispersive Infrared (NDIR) Absorption
Carrier GasesHe (99.995% purity), N₂ or Ar (99.995% purity), 2–4 bar
Power Supply3-phase, 400 V, 50/60 Hz, max. 8.5 kVA
Dimensions (W×H×D)56 × 78 × 64 cm
Weight~165 kg