| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | ON-p |
| Instrument Type | Oxygen and Nitrogen Analyzer |
| Analysis Range | 0.1 ppm – 2% |
| Analysis Time | 90 s |
| Detection Limit (N) | 0.01 ppm |
| Furnace Max Temperature | 3000 °C |
| Furnace Power | 8.5 kW |
| Detection Principle | Inert Gas Fusion Coupled with IR Absorption (O) and Thermal Conductivity (N) |
| Carrier Gas Options | He or Ar |
| Software | ELTRA Analytical Software (Supports CFR 21 Part 11 Compliance, Audit Trail, Multi-Point Calibration, Report Export, Comment Annotation) |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | H-500 |
| Instrument Type | Hydrogen Analyzer |
| Analysis Range (Low-H) | 0.1 ppm – 200 ppm |
| Analysis Range (High-H) | 10 ppm – 2% |
| Accuracy (Low-H) | ±0.1 ppm or ±1% |
| Accuracy (High-H) | ±2 ppm or ±1% |
| Sensitivity (H) | 0.01 ppm |
| Analysis Time | 2–3 min |
| Maximum Sample Mass | 10 g |
| Sample Dimensions | ≤ 0.8 × 6 cm |
| Furnace Max Temperature | 1000 °C (1 °C adjustable) |
| Carrier Gas | High-purity N₂ |
| Detector Configuration | Dual thermal conductivity cells with differential sensitivity |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | OH-p 2 |
| Instrument Type | Oxygen/Hydrogen Analyzer |
| Analysis Time | 120–180 s |
| Pulse Furnace Power | Up to 8,500 W |
| Detection Principle | Non-Dispersive Infrared (NDIR) for Oxygen, Thermal Conductivity Detection (TCD) for Hydrogen |
| Sample Form Compatibility | Solid rods, granules, powders |
| Max. Sample Weight | 2 g |
| Compliant Standards | ASTM E1019, DIN EN 3976 |
| Carrier Gas Options | Argon (economical), Helium |
| Optional | Automatic Graphite Crucible Cleaner |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | OH-p |
| Instrument Type | Oxygen/Hydrogen Analyzer |
| Analysis Range | Oxygen 0.1 ppm – 2.0 wt%, Hydrogen 0.01 ppm – 1000 ppm |
| Analysis Time | Oxygen 85 s, Hydrogen 100 s |
| Furnace Max Temperature | 3000 °C |
| Furnace Power | 8.5 kW |
| Detection Principle | Inert Gas Fusion Coupled with IR Absorption (O) and Thermal Conductivity Detection (H) |
| Sample Form | Solid, granular, or chip-shaped inorganic materials (e.g., metals, ceramics, refractories) |
| Calibration | Single-point and multi-point linear regression |
| Cooling Options | Tap water, recirculating chiller, or heat exchanger |
| Compliance Support | ASTM E1019, ISO 14284, ISO 22371, USP <232>/<233>, GLP/GMP-ready data audit trail |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | ON-p 2 |
| Analysis Time | 120–180 s |
| Pulse Furnace Power | Up to 8.5 kW |
| Maximum Furnace Temperature | 3000 °C |
| Sample Weight Capacity | Up to 2000 mg |
| Detection Principle | Non-Dispersive Infrared (NDIR) for Oxygen, Thermal Conductivity Detection (TCD) for Nitrogen |
| Compliance | ASTM E1019, DIN EN 3976 |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | ELEMENTRAC ONH-p 2 |
| Analysis Elements | Oxygen, Nitrogen, Hydrogen |
| Analysis Range | O: 0.1 ppm–2.0 wt% |
| N | 0.1 ppm–2.0 wt% |
| H | 0.01 ppm–1000 ppm |
| Detection Limits | O: 0.1 ppm |
| N | 0.1 ppm |
| H | 0.01 ppm |
| Analysis Time | 120–180 s (typical) |
| Pulse Furnace Power | up to 8.5 kW |
| Maximum Furnace Temperature | 3000 °C |
| Detection Principle | O by Non-Dispersive Infrared (NDIR) Absorption |
| Carrier Gases | He (99.995% purity), N₂ or Ar (99.995% purity), 2–4 bar |
| Power Supply | 3-phase, 400 V, 50/60 Hz, max. 8.5 kVA |
| Dimensions (W×H×D) | 56 × 78 × 64 cm |
| Weight | ~165 kg |