Empowering Scientific Discovery

Verder (Shanghai) Instrumentation & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelON-p
Instrument TypeOxygen and Nitrogen Analyzer
Analysis Range0.1 ppm – 2%
Analysis Time90 s
Detection Limit (N)0.01 ppm
Furnace Max Temperature3000 °C
Furnace Power8.5 kW
Detection PrincipleInert Gas Fusion Coupled with IR Absorption (O) and Thermal Conductivity (N)
Carrier Gas OptionsHe or Ar
SoftwareELTRA Analytical Software (Supports CFR 21 Part 11 Compliance, Audit Trail, Multi-Point Calibration, Report Export, Comment Annotation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCS-d
Measurement PrincipleInfrared Absorption
Heating SystemHigh-Frequency Induction Furnace & Resistance Furnace
Carbon Range0.0012–70 mg
Sulfur Range0.0006–30 mg
Sensitivity0.01 ppm
Accuracy±0.2 ppm or ±0.5% RSD
Analysis Time45 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEltra
OriginGermany
ModelCS-i
Measurement PrincipleInfrared Absorption
Heating SystemHigh-Frequency Induction Furnace (2.2 kW, up to 2,000 °C)
Measurement RangeC: 0.6 ppm – 6.0 wt%, S: 0.6 ppm – 4.5 wt%
SensitivityC: 0.1 ppm, S: 0.1 ppm
Accuracy±0.2 ppm
Analysis Time40 s
Detector ConfigurationUp to 4 tunable infrared cells (including optional gold-plated cells for halogen- or acid-resistant applications)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelH-500
Instrument TypeHydrogen Analyzer
Analysis Range (Low-H)0.1 ppm – 200 ppm
Analysis Range (High-H)10 ppm – 2%
Accuracy (Low-H)±0.1 ppm or ±1%
Accuracy (High-H)±2 ppm or ±1%
Sensitivity (H)0.01 ppm
Analysis Time2–3 min
Maximum Sample Mass10 g
Sample Dimensions≤ 0.8 × 6 cm
Furnace Max Temperature1000 °C (1 °C adjustable)
Carrier GasHigh-purity N₂
Detector ConfigurationDual thermal conductivity cells with differential sensitivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelOH-p 2
Instrument TypeOxygen/Hydrogen Analyzer
Analysis Time120–180 s
Pulse Furnace PowerUp to 8,500 W
Detection PrincipleNon-Dispersive Infrared (NDIR) for Oxygen, Thermal Conductivity Detection (TCD) for Hydrogen
Sample Form CompatibilitySolid rods, granules, powders
Max. Sample Weight2 g
Compliant StandardsASTM E1019, DIN EN 3976
Carrier Gas OptionsArgon (economical), Helium
OptionalAutomatic Graphite Crucible Cleaner
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEltra
OriginGermany
ModelCS-r
Measurement PrincipleInfrared Absorption
Heating SystemHorizontal Resistance Furnace (600–1550 °C)
Max. Sample Weight500 mg
Detection Range20 ppm to 100%
IR CellsUp to 4
ComplianceASTM, DIN, EN, ISO
Optional ElementsC, S, H (configurable combinations)
Sample PortOptimized Low-Blank Design
Detector CellGold-Plated IR Cells
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCS-580A
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating SystemVertical Resistance Furnace with Ceramic Tube
Max. Furnace Temperature1550 °C (adjustable in 1 °C increments)
Sample Weight CapacityUp to 500 mg
Analysis Time60–120 s per sample
Combustion Power OutputUp to 2000 W
Carbon Range0.005–100 wt% (customizable)
Sulfur Range0.005–20 wt% (customizable)
Detector ConfigurationUp to four gold-coated NDIR cells
Autosampler Options36-position or 130-position ceramic crucible carousel
ComplianceDesigned for ISO 9556 (steel), ISO 4935 (ferrous alloys), ASTM E1019, and USP <231> elemental impurity testing workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCHS-580A
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemVertical Resistance Furnace (Ceramic Tube, Max. 1550 °C, Adjustable in 1 °C Increments)
Sample CapacityUp to 500 mg (Including Heterogeneous Materials)
Analysis Time60–180 s per Sample
Combustion PowerUp to 2000 W
C Range0.005–100 wt%
H Range0.01–15 wt%
S Range0.005–20 wt% (Customizable Ranges Available)
Autosampler Options36-position or 130-position Crucible Carousels
IR Cell EnhancementGold-Coated Optical Path for Extended Lifetime and Compatibility with Halogen- or Acid-Containing Samples
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCW-800M
Measurement PrincipleInfrared Absorption
Heating SystemResistance Furnace
Temperature RangeUp to 1000 °C (adjustable in 1 °C increments)
CO₂ Measurement Range0–70 %
H₂O Measurement Range0–20 %
Sensitivity0.0001 % for both CO₂ and H₂O
Accuracy±0.02 %
Analysis Time2–30 minutes
Detection CellsDual independent gold-coated IR cells
Atmosphere OptionsO₂ or inert gas (e.g., N₂)
Programmable Temperature StepsUp to 5 per method
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelOH-p
Instrument TypeOxygen/Hydrogen Analyzer
Analysis RangeOxygen 0.1 ppm – 2.0 wt%, Hydrogen 0.01 ppm – 1000 ppm
Analysis TimeOxygen 85 s, Hydrogen 100 s
Furnace Max Temperature3000 °C
Furnace Power8.5 kW
Detection PrincipleInert Gas Fusion Coupled with IR Absorption (O) and Thermal Conductivity Detection (H)
Sample FormSolid, granular, or chip-shaped inorganic materials (e.g., metals, ceramics, refractories)
CalibrationSingle-point and multi-point linear regression
Cooling OptionsTap water, recirculating chiller, or heat exchanger
Compliance SupportASTM E1019, ISO 14284, ISO 22371, USP <232>/<233>, GLP/GMP-ready data audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelON-p 2
Analysis Time120–180 s
Pulse Furnace PowerUp to 8.5 kW
Maximum Furnace Temperature3000 °C
Sample Weight CapacityUp to 2000 mg
Detection PrincipleNon-Dispersive Infrared (NDIR) for Oxygen, Thermal Conductivity Detection (TCD) for Nitrogen
ComplianceASTM E1019, DIN EN 3976
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelELEMENTRAC ONH-p 2
Analysis ElementsOxygen, Nitrogen, Hydrogen
Analysis RangeO: 0.1 ppm–2.0 wt%
N0.1 ppm–2.0 wt%
H0.01 ppm–1000 ppm
Detection LimitsO: 0.1 ppm
N0.1 ppm
H0.01 ppm
Analysis Time120–180 s (typical)
Pulse Furnace Powerup to 8.5 kW
Maximum Furnace Temperature3000 °C
Detection PrincipleO by Non-Dispersive Infrared (NDIR) Absorption
Carrier GasesHe (99.995% purity), N₂ or Ar (99.995% purity), 2–4 bar
Power Supply3-phase, 400 V, 50/60 Hz, max. 8.5 kVA
Dimensions (W×H×D)56 × 78 × 64 cm
Weight~165 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelSURFACEC-800
Measurement PrincipleInfrared Absorption
Heating SystemResistance Furnace
Measurement Range (Low)0.1–100 µg C/cm²
Measurement Range (High)1–1,000 µg C/cm²
Analysis Time60–90 s
Maximum Furnace Temperature1000 °C (1 °C adjustable)
Carrier GasOxygen
Detection SystemDual Independent IR Cells
CalibrationCertified Reference Materials or Standard Gases
Flow ControlElectronic Mass Flow Controller
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCHS-r
Measurement PrincipleInfrared Absorption (CO₂, SO₂, H₂O detection)
Furnace TypeHorizontal Resistance Furnace with Ceramic Tube
Temperature Range600 °C to 1550 °C
Sample Weight CapacityUp to 500 mg
Detection Range20 ppm to 100 wt%
ComplianceASTM D5373, ASTM D7289, ISO 11725, ISO 20362, DIN 51721, EN 15407
Key FeaturesTriple IR detection cells (C, H, S), gold-plated IR cells, low-blank sample inlet, oxygen flow control with electronic mass flow meter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCW-800
Measurement PrincipleInfrared Absorption
Heating SystemResistance Furnace (up to 1000 °C, adjustable in 1 °C increments)
Sample IntroductionQuartz Boat
Carrier GasNitrogen (standard)
DetectionDual Independent IR Cells (CO₂ and H₂O)
Cell MaterialGold-Plated IR Cells
CalibrationSingle-Point and Multi-Point
Gas Flow ControlElectronic Mass Flow Controller
ComplianceDesigned for GLP/GMP environments
SoftwareMultilingual, customizable reporting, real-time process monitoring
Analysis Time~2–3 min per sample
Sample FormSolids (powders, granules, pellets)
MaintenanceMaintenance-free gas path
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelELEMENTRAC CN-r
Analysis PrincipleDumas Combustion Method
Sample Throughput<3 min per sample
DetectionTotal Carbon (C) and Total Nitrogen (N), Protein Calculation (N × conversion factor)
AutomationIntegrated Autosampler with RFID/Barcode Sample Recognition
Control SystemBuilt-in Industrial PC with Touchscreen Interface
Gas SupplyHigh-Purity Oxygen Flow
CatalystChromium-Free Oxidation Catalyst
ComplianceDesigned for GLP/GMP environments
Sample FormsSolids, Powders, Liquids, Pastes
MaintenanceFull consumables replacement in <20 min
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0