BrandELTRA
OriginGermany
ModelCS-d
Measurement PrincipleInfrared Absorption
Heating SystemHigh-Frequency Induction Furnace & Resistance Furnace
Carbon Range0.0012–70 mg
Sulfur Range0.0006–30 mg
Sensitivity0.01 ppm
Accuracy±0.2 ppm or ±0.5% RSD
Analysis Time45 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEltra
OriginGermany
ModelCS-i
Measurement PrincipleInfrared Absorption
Heating SystemHigh-Frequency Induction Furnace (2.2 kW, up to 2,000 °C)
Measurement RangeC: 0.6 ppm – 6.0 wt%, S: 0.6 ppm – 4.5 wt%
SensitivityC: 0.1 ppm, S: 0.1 ppm
Accuracy±0.2 ppm
Analysis Time40 s
Detector ConfigurationUp to 4 tunable infrared cells (including optional gold-plated cells for halogen- or acid-resistant applications)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEltra
OriginGermany
ModelCS-r
Measurement PrincipleInfrared Absorption
Heating SystemHorizontal Resistance Furnace (600–1550 °C)
Max. Sample Weight500 mg
Detection Range20 ppm to 100%
IR CellsUp to 4
ComplianceASTM, DIN, EN, ISO
Optional ElementsC, S, H (configurable combinations)
Sample PortOptimized Low-Blank Design
Detector CellGold-Plated IR Cells
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCS-580A
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating SystemVertical Resistance Furnace with Ceramic Tube
Max. Furnace Temperature1550 °C (adjustable in 1 °C increments)
Sample Weight CapacityUp to 500 mg
Analysis Time60–120 s per sample
Combustion Power OutputUp to 2000 W
Carbon Range0.005–100 wt% (customizable)
Sulfur Range0.005–20 wt% (customizable)
Detector ConfigurationUp to four gold-coated NDIR cells
Autosampler Options36-position or 130-position ceramic crucible carousel
ComplianceDesigned for ISO 9556 (steel), ISO 4935 (ferrous alloys), ASTM E1019, and USP <231> elemental impurity testing workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCHS-580A
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemVertical Resistance Furnace (Ceramic Tube, Max. 1550 °C, Adjustable in 1 °C Increments)
Sample CapacityUp to 500 mg (Including Heterogeneous Materials)
Analysis Time60–180 s per Sample
Combustion PowerUp to 2000 W
C Range0.005–100 wt%
H Range0.01–15 wt%
S Range0.005–20 wt% (Customizable Ranges Available)
Autosampler Options36-position or 130-position Crucible Carousels
IR Cell EnhancementGold-Coated Optical Path for Extended Lifetime and Compatibility with Halogen- or Acid-Containing Samples
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCW-800M
Measurement PrincipleInfrared Absorption
Heating SystemResistance Furnace
Temperature RangeUp to 1000 °C (adjustable in 1 °C increments)
CO₂ Measurement Range0–70 %
H₂O Measurement Range0–20 %
Sensitivity0.0001 % for both CO₂ and H₂O
Accuracy±0.02 %
Analysis Time2–30 minutes
Detection CellsDual independent gold-coated IR cells
Atmosphere OptionsO₂ or inert gas (e.g., N₂)
Programmable Temperature StepsUp to 5 per method
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelSURFACEC-800
Measurement PrincipleInfrared Absorption
Heating SystemResistance Furnace
Measurement Range (Low)0.1–100 µg C/cm²
Measurement Range (High)1–1,000 µg C/cm²
Analysis Time60–90 s
Maximum Furnace Temperature1000 °C (1 °C adjustable)
Carrier GasOxygen
Detection SystemDual Independent IR Cells
CalibrationCertified Reference Materials or Standard Gases
Flow ControlElectronic Mass Flow Controller
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCHS-r
Measurement PrincipleInfrared Absorption (CO₂, SO₂, H₂O detection)
Furnace TypeHorizontal Resistance Furnace with Ceramic Tube
Temperature Range600 °C to 1550 °C
Sample Weight CapacityUp to 500 mg
Detection Range20 ppm to 100 wt%
ComplianceASTM D5373, ASTM D7289, ISO 11725, ISO 20362, DIN 51721, EN 15407
Key FeaturesTriple IR detection cells (C, H, S), gold-plated IR cells, low-blank sample inlet, oxygen flow control with electronic mass flow meter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELTRA
OriginGermany
ModelCW-800
Measurement PrincipleInfrared Absorption
Heating SystemResistance Furnace (up to 1000 °C, adjustable in 1 °C increments)
Sample IntroductionQuartz Boat
Carrier GasNitrogen (standard)
DetectionDual Independent IR Cells (CO₂ and H₂O)
Cell MaterialGold-Plated IR Cells
CalibrationSingle-Point and Multi-Point
Gas Flow ControlElectronic Mass Flow Controller
ComplianceDesigned for GLP/GMP environments
SoftwareMultilingual, customizable reporting, real-time process monitoring
Analysis Time~2–3 min per sample
Sample FormSolids (powders, granules, pellets)
MaintenanceMaintenance-free gas path