- All
- Favorite
- Popular
- Most rated
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS200 DIGIT CA |
| Principle | Electromagnetically Driven Vibratory Sieving |
| Measurement Range | 20 µm – 25 mm |
| Max. Load | 3 kg |
| Max. Sieve Stack Height | 510 mm |
| Sieve Levels | 9 or 17 |
| Amplitude Control | Digital, 0.2–3.0 mm |
| Sieving Time | 1–99 min (digital display) |
| Intermittent Mode | Fixed 10 s on/off cycles |
| Sieve Diameters Supported | 100 mm, 200 mm, 203 mm (8") |
| Enclosure Rating | IP21 |
| Net Weight | ~35 kg |
| Compliance | CE |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER ONLINE |
| Application Sector | Pharmaceutical Manufacturing |
| Instrument Type | Dynamic In-line Analyzer |
| Measurement Range | 22 µm – 35 mm |
| Measured Parameters | 32 morphological parameters including dimensional, shape, surface roughness, density, transparency, and true 3D characterization |
| Imaging Speed | Up to 100 high-resolution images per second |
| Design | Compact, explosion-proof (ATEX/IECEx compliant), integrated auto-cleaning mechanism |
| Compliance | Designed for GMP environments with audit-trail-ready data handling |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 CS ECO |
| Instrument Type | Rockwell Hardness Tester |
| Force Range | 1–250 kg (9.81–2452 N) |
| Test Height | 250 mm |
| Throat Depth | 157 mm |
| Maximum Specimen Weight | 100 kg |
| Machine Weight | 77 kg |
| Display | 7-inch capacitive color touchscreen |
| Force Application | Electromechanical, fully automated |
| Power Supply | 100–240 V AC, 45–65 Hz, ~60 W |
| Compliance | ASTM E18, ISO 6508, DIN 50103, GB/T 230.2 |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CAMSIZER XL |
| Application Field | Pharmaceutical |
| Instrument Type | Dynamic |
| Measurement Range | 160 µm – 135 mm |
| Camera Resolution | 2560 × 2048 pixels, up to 62 frames per second at maximum resolution |
| Measured Parameters | Dimensional parameters (15), Shape/Shape Factor parameters (13), Surface Roughness (3), Density, Transparency, and 3D Morphology |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | TGA Thermostep ML |
| Temperature Range | 50–1000 °C |
| Temperature Accuracy | ±1 K |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 5 g |
| Simultaneous Sample Capacity | Up to 19 samples |
| Operating Environment | High-temperature inert or oxidative atmospheres (N₂, air, O₂) |
| Instrument Type | Benchtop manual-operation TGA system |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | PT200 |
| Sample Inlet Size | ≤ 10 mm |
| Rotation Speed | 50 rpm |
| Dividing Ports | 1–3 (configurable) |
| Split Ratio Range | 1:5 to 1:26 per port |
| Slit Width Adjustment | 0–159 mm (1-port), 0–110 mm (2-port), 0–53 mm (3-port) |
| Time Setting | Digital, 1–60 min or continuous |
| Container Capacity | 250 mL / 500 mL (collection), 30 L (waste) |
| Power Supply | 100–240 V, 50/60 Hz |
| Dimensions (W×H×D) | 520 × 1050 × 551 mm (base unit) |
| Weight | ~46 kg (incl. DR 100) |
| Compliance | CE, DIN 51701 |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | PT600 |
| Sample Capacity | 6,000–15,000 mL |
| Dividing Modules | 4 / 6 / 8 / 10-way (batch) or 1-way (with reject) |
| Rotational Speed | 18–53 rpm |
| Vibration Feeder | Digital control |
| Rejection Mode | Continuous single-stream discharge |
| Observation Window | Illuminated |
| Hopper Volume | 70 L |
| Dimensions (W×H×D) | 1180 × 1620 × 750 mm |
| Net Weight | ~230 kg |
| Power Supply | 240 V, 50 Hz, Single-phase |
| Compliance | CE-marked |
| Application Scope | Bulk granular & powdered materials in agriculture, geology, construction, pharma, food, metallurgy, environmental analysis |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | RT |
| Division Ratio | 1:1 (2-way split) |
| Max. Feed Size (RT 75) | ~50 mm |
| Max. Batch Capacity (RT 75) | 16 L |
| Dimensions (W×H×D, RT 75) | 620 × 420 × 260 mm |
| Net Weight (RT 75) | ~12.5 kg |
| Compliance | DIN 51701-4 |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | THERMOSTEP |
| Maximum Operating Temperature | 1000 °C |
| Temperature Resolution | 1 °C |
| Sample Capacity | Up to 19 positions |
| Maximum Sample Mass | 5 g |
| Balance Resolution | 0.0001 g |
| Software | Windows®-based, Multilingual, Customizable Reporting |
| Compliance | Designed for ASTM D3172, D3174, D3175, ISO 1171, ISO 562, USP <281>, EN 15169, and GLP/GMP-aligned data integrity workflows |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CAMSIZER X2 |
| Application Fields | Pharmaceutical, Chemical, Materials Science, Additive Manufacturing, Battery Materials |
| Instrument Type | Dynamic Imaging Analyzer |
| Number of Lenses | Dual-Lens System (ISO 13322-2 Compliant) |
| Measurement Range | 0.8 µm – 8 mm |
| Sample Dispersion Methods | X-Jet (Compressed Air Jet Disperser), X-Flow (Wet Dispersion with Ultrasonic Agitation), X-Fall (Gravity-Based Free-Fall Dry Dispersion) |
| Optical Resolution | 0.8 µm per pixel (effective particle detection limit) |
| Measured Morphological Parameters | Aspect Ratio, Symmetry, Sphericity, Convexity, Solidity, Circularity, Elongation, Roundness, Compactness, Transparency Index, Density Estimation (via grayscale calibration) |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 M EVO / QNESS 750 M EVO / QNESS 3000 M EVO |
| Testing Force Range | QNESS 250 M EVO: 1–250 kgf (9.81–2450 N) |
| QNESS 750 M EVO | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 M EVO | 0.3–3000 kgf (2.94–29430 N) |
| Max Test Height | 510 mm |
| Throat Depth | 320 mm |
| Anvil Dimensions | 584 × 450 mm |
| Weight | 490 kg |
| Imaging | 5 MP industrial Ethernet camera, up to 270 fps |
| Turret | 2-position standard or 8-position optional |
| Software | Qpix T2 (optional Qpix CONTROL 2 M) |
| OS | Windows 10 IoT |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max Power Consumption | ~480 W |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 / 750 / 3000 CS/C EVO |
| Test Force Range | QNESS 250 CS: 1–250 kg (9.81–2450 N) |
| QNESS 750 CS | 0.3–750 kg (2.94–7358 N) |
| QNESS 3000 CS | 0.3–3000 kg (2.94–29430 N) |
| QNESS 250 C | 1–250 kg (9.81–2450 N) |
| QNESS 750 C | 0.3–750 kg (2.94–7358 N) |
| QNESS 3000 C | 0.3–3000 kg (2.94–29430 N) |
| Test Height | C version: 395 mm |
| CS version | 175 mm |
| Throat Depth | 220 mm |
| Anvil Diameter | Ø100 mm |
| Turret Configuration | 2-position standard or 8-position optional |
| Imaging System | 5 MP industrial Ethernet camera, up to 270 FPS |
| Objective Lenses | XLED 1, XLED 2, XLED 5, 5×, 10×, 20×, 50×, 100× |
| Field of View | 0.113 × 0.084 mm (at 100×) to 7.98 × 5.97 mm (at XLED 1) |
| Display | 12″ capacitive touchscreen |
| Operating System | Windows 10 IoT |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max. Power Consumption | ~480 W |
| Weight | QNESS 250/750 CS: 250 kg |
| QNESS 3000 CS & all C versions | 300 kg |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 60 A/A+ EVO |
| Instrument Type | Microhardness Tester |
| Test Force Range | 0.25 g – 62.5 kgf |
| Indenter | ASTM- and DAkkS-certified Vickers diamond |
| Turret | 8-position motorized |
| Illumination | White LED with electric iris shutter |
| Software | Qpix Control2 with intuitive 3D control interface |
| Positioning System | Direct-read linear encoders on X/Y/Z axes (0.5 µm resolution) |
| Optional Feature (A+ only) | Panoramic camera with automated image acquisition (49 × 37 mm field of view) |
| Microstructural Analysis Module | INSPECT (modularly licensable) |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 R |
| Instrument Type | Rockwell Hardness Tester |
| Test Force Range | 1–250 kg (9.81–2450 N) |
| Test Height / Throat Depth | 260 mm / 180 mm |
| Extended Test Height (Optional) | 450 mm |
| Vertical Adjustment Speed | up to 6 mm/s |
| Anvil/Cross Table Dimensions | 250 × 260 mm |
| Data Interfaces | 3× USB, 1× Ethernet, 1× RS232 |
| Unit Weight | 95 kg (112 kg with height extension) |
| Max. Specimen Weight | 100 kg |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~240 W |
| Software | Qpix T2R |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS200 Jet |
| Principle | Air jet sieving (dynamic air-assisted vibration) |
| Measurement Range | 10 µm – 4 mm |
| Maximum Sample Load | 0.3 g – 100 g (standard operation) |
| Sieve Stack Capacity | 1 sieve (2-stage separation possible when combined with integrated cyclone separator) |
| Sieve Diameter Compatibility | 200 mm (8") |
| Vibration Frequency | 280 min⁻¹ (4.67 Hz) |
| Tapping Intensity | 150 taps per cycle |
| Operating Mode | Fixed-amplitude, digitally controlled air pulse modulation |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 A/A+ |
| Instrument Type | Rockwell Hardness Tester |
| Test Force Range | 1–250 kg (9.81–2450 N) |
| Test Height / Throat Depth | 187 mm / 180 mm (extendable to 377 mm) |
| Maximum Specimen Weight | 50 kg |
| Motorized Cross-Table Dimensions | 170 × 250 mm |
| Height Adjustment Speed | up to 6 mm/s |
| Power Supply | 230 V~1/N/PE or 110 V~1/N/PE |
| Max. Power Consumption | ~240 W |
| Host Weight | 120 kg (137 kg with height extension) |
| Interface | 3× USB |
| Software | Qpix Control2 |
| Optional Features | Dual high-resolution camera system (up to 2×), panoramic camera (A+ only), motorized anvil/cross-table, Jominy fixture, multi-specimen holders, interchangeable indenters and objectives |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | PT100 |
| Sample Division Principle | Rotating Cone Divider (Rotary Splitter) |
| Dividing Ports | 6, 8 or 10 |
| Rotation Speed | 110 rpm (electronically regulated, load- and frequency-independent) |
| Maximum Feed Size | ≤10 mm |
| Batch Capacity | Up to 5000 mL |
| Container Options | 100 mL, 250 mL or 500 mL wide-neck or Duran® laboratory bottles |
| Timer Range | 1–60 min or continuous operation |
| Dimensions (W×H×D) | 580 × 910 × 420 mm (including optional DR 100 dosing unit) |
| Net Weight | ~33.5 kg |
| Compliance | CE-marked |
| Maintenance | Maintenance-free drive |
| Noise Level | Low-noise operation |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 A/A+, QNESS 750 A/A+, QNESS 3000 A/A+ EVO |
| Test Force Range | QNESS 250 A/A+: 1–250 kgf (9.81–2450 N) |
| QNESS 750 A/A+ | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 A/A+ | 0.3–3000 kgf (2.94–29430 N) |
| Test Height Adjustment | Motorized asynchronous Z-axis, up to 3200 kg clamping force |
| Throat Depth / Max Vertical Clearance | 362 mm / 320 mm |
| XY Stage Travel | X 460 mm × Y 350 mm |
| Stage Size | 450 × 297 mm (motorized cross-slide) |
| Imaging System | 5 MP panoramic camera (A+ models only) |
| Software | Qpix Control2 with 3D UI, Ethernet interface (RJ45) |
| Compliance | Designed for ASTM E10, E18, E92, E384, ISO 6506, ISO 6507, ISO 6508, ISO 20422, and EN ISO 1463 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS CHD MASTER+ |
| Hardness Testing Methods | Vickers, Knoop, Brinell |
| Test Load Range | 0.49 – 98.1 N (50 g – 10 kgf) |
| Turret | 6-position, motorized |
| X/Y/Z Travel | 150 × 150 × 145 mm |
| Specimen Weight Capacity | ≤ 50 kg |
| Host Weight | 58 kg |
| Camera System | 5 MP color CMOS |
| Positioning Repeatability | ±3.5 µm |
| Interface | 1× USB 3.0 (hardness tester–PC), optional QDAS/PCI/AMS/REMOTE modules |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~200 W |
| Objective Lenses | 4×, 20×, 40× |
| Certified Vickers Indenters | DakkS-accredited |
| Sample Holders | CHD Master+: single-position (Ø30/40/50 mm), quad-position (Ø30/40/50 mm), octo-position (Ø30/40 mm) |
| Brand | Microtrac MRB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PARTAN 3D |
| Application Sector | Pharmaceutical |
| Instrument Type | Dynamic |
| Measurement Range | 22 µm – 35 mm |
| Camera Resolution | 2560 × 2048 pixels |
| Measured Parameters | Dimensional (length, width, thickness), Shape (13 descriptors), Surface Roughness (3 parameters), Density, Transparency, 3D Morphology |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Q10 CHD MASTER/Plus |
| Instrument Type | Microhardness Tester |
| Control System | Electromechanical closed-loop sensor actuation |
| Turret | 6-position motorized turret |
| Operating Concept | 3D intuitive human-machine interface |
| Test Automation | Fully programmable sequence-based testing with adaptive dwell-time termination |
| Data Output | Configurable report templates with embedded hardness conversion algorithms |
| Image Quality | High-resolution optical imaging system with LED illumination and digital autofocus capability |
| Testing Space | Large X-Y-Z travel range (X: 200 mm, Y: 200 mm, Z: 150 mm) |
| Connectivity | Ethernet, USB 3.0, RS-232, optional integration with LIMS and MES systems |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | AS200 Digital |
| Measurement Range | 20 µm – 25 mm |
| Max. Sample Load | 3 kg |
| Max. Sieve Stack Mass | 6 kg |
| Sieve Diameter Options | 100 mm / 150 mm / 200 mm / 203 mm (8") |
| Sieve Stack Height | up to ~450 mm |
| Dimensions (W × H × D) | 400 × 230 × 350 mm |
| Net Weight | ~30 kg |
| Drive Type | Electromagnetic, 3D oscillation |
| Programmable Methods | 9 stored parameter sets |
| Compliance | CE, DIN EN ISO 9000 series, GLP-ready |
| Brand | Retsch |
|---|---|
| Origin | Germany |
| Model | RT100 |
| Sample Capacity | ≤ 30 L |
| Number of Subsamples | 2 |
| Adjustable Groove Width | 12–108 mm (in 12-mm increments) |
| Dimensions (W×H×D) | 72 × 70 × 46 cm |
| Net Weight | ~55 kg |
| Compliance | DIN 51701 |
| Power Requirement | None (manual operation) |
| Brand | QATM |
|---|---|
| Country of Origin | Austria |
| Model | Q150 R / Q150 A / Q150 A+ |
| Hardness Scales | Rockwell (R), Brinell (B), Vickers (HV), Knoop (HK) |
| Automation Levels | Manual (R), Semi-Automatic & Fully Automatic (A), Fully Automatic with Integrated Panoramic Imaging (A+) |
| Test Force Range | 1–3000 kgf (A/A+ models) |
| Sample Height Clearance | Up to 280 mm |
| Max. Sample Weight | 50 kg |
| Interface Options | RS232, Ethernet, USB |
| Compliance | CE, ISO 6508 (Rockwell), ISO 6506 (Brinell), ISO 6507 (Vickers), ISO 4545 (Knoop), ASTM E18, E10, E384, E92 |
| Software | Qpix T2R v5.x (GLP-compliant data logging, audit trail, user access levels, report export to PDF/CSV/XLSX) |
Show next