Water Oil Bath Constant Temperature Tank
Filter
Showing 331–360 of 709 results
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | CS-5B |
| Temperature Stability | ±0.03 °C |
| Bath Volume | 4.5 L |
| Circulation Type | Internal & External |
| Temperature Control | Heating & Cooling |
| Heating Method | Stainless Steel Immersion Heater |
| Control Technology | PID1 + ACC Algorithm |
| Calibration | ATC1 Single-Point Self-Calibration |
| Safety Features | Overtemperature Protection, Low-Level Float Switch with Audio-Visual Alarm & Power Cut-off, Lockable Power Plug, Dry-Run Prevention |
| Noise Level | Low-Noise Design |
| Dimensions (W×L×H) | 17 × 33 × 36 cm |
| Bath Opening/Depth | 15 × 15 / 15 cm |
| Time to Boil | 15 min |
| Pump Flow Rate | 6 L/min at 0.1 bar |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | DD |
| Instrument Type | Heating Circulating Bath |
| Temperature Range | +5 °C to +200 °C |
| Temperature Stability | ±0.01 °C |
| Display | 3.5" TFT Color Screen |
| Heating Power | 2 kW |
| Pump Flow Rate | 8–23 L/min |
| Pump Pressure | 0.1–0.6 bar |
| Max. Fluid Viscosity | 50 cSt |
| External PT100 Input | Yes |
| Compliance | DIN 12876-1 Class III (FL) for Flammable Liquids |
| Dimensions (W×L×H) | 13.2 × 16 × 35.5 cm |
| Weight | 2.5 kg |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | DD-201FS |
| Temperature Range | –20 °C to +150 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 3–4 L |
| Internal/External Circulation | Yes |
| Cooling/Heating Type | Dual-mode |
| Stirring Speed | 100–1600 rpm |
| Stirring Position | 1 |
| Compliance | EN 61010, EN 61326, DIN 12876-1 Class III (FL), WEEE/RoHS |
| Interface | USB, M16×1 male external circulation port |
| Safety Features | Overtemperature protection, low-level float switch with audiovisual alarm and auto-shutdown, ATC self-calibration, Safety-lock power connector |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | DT-31A / DT-18V / DT-16G |
| Temperature Range | Ambient +5 °C to +150 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 13–40 L |
| Circulation | Internal & External |
| Display Resolution | 0.01 °C |
| Compliance | ASTM D445, ISO 3104, ISO 12185 |
| Vacuum-Insulated Viewing Windows (DT-18V | 185 × 245 mm, multi-layer) |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | DD-200F |
| Temperature Range | −20 °C to +200 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 3–4 L |
| Circulation Type | Internal & External |
| Control Method | PID with ATC3 Multi-Point Calibration |
| Display | 3.5" TFT Color Screen |
| Heating Power | 2 kW |
| Refrigeration Power (Ethanol, −20 °C) | 0.02 kW |
| Pump Flow Rate | 8–27 L/min |
| Pump Pressure | 0.1–0.7 bar |
| Max. Fluid Viscosity | ≤50 cSt |
| Bath Opening/Depth | 13 × 15 / 15 cm |
| Internal Tubing Diameters | 8 mm & 12 mm |
| Refrigerant | R134a (70 g, GWP = 1430) |
| Safety Class | DIN 12876-1 Class III (FL) |
| Interface Options | USB (standard), RS232 or Analog I/O (optional) |
| Ambient Operating Temp. | 5–40 °C |
| Dimensions (W×L×H) | 23 × 39 × 65 cm |
| Weight | 25.7 kg |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model Series | DD-201F, DD-200F, DD-300F, DD-601F, DD-600F, DD-900F, DD-1000F, DD-1001F |
| Temperature Range | −20 °C to +200 °C (up to −50 °C in select models) |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 3–56 L |
| Heating Power | up to 2 kW |
| Refrigeration Power (in ethanol) | 0.02–1.0 kW (model- and temperature-dependent) |
| Pump Flow Rate | 8–27 L/min |
| Max. Pump Pressure | 0.7 bar |
| Control Interface | 3.5″ TFT color display with rotary encoder |
| Compliance | DIN 12876-1 Class III (FL) for flammable media |
| Cooling Method | Air-cooled, front-intake/rear-exhaust design |
| Refrigerant | R134a or R449A (low-GWP) |
| Safety Certification | Integrated overtemperature, low-level, and dry-run protection |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | DYNEO Series |
| Temperature Range | Room Temperature +5 °C to 200 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 3–26 L |
| Heating Power | 2–8 kW |
| Pump Flow Rate | 0.1–0.7 bar (adjustable) |
| Bath Opening/Depth | 13×15 cm / 15 cm to 26×35 cm / 20 cm |
| External/Internal Circulation | Selectable via front-panel lever |
| Compliance | DIN 12876-1 Class III (FL) for flammable bath fluids |
| Control Interface | 3.5" TFT color display with PID2 control, ATC3 multi-point calibration, TCF adaptive temperature control |
| Communication Options | USB (standard), optional RS232 or analog output |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | F25-HL |
| Temperature Range | −28 °C to +200 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 4.5 L |
| Circulation Type | Internal & External |
| Control Mode | Heating & Cooling |
| Display | VFD/LCD with Backlight |
| Temperature Control Technology | ICC (Intelligent Control Circuit) + TCF (Thermal Control Function) |
| Calibration | ATC3 Three-Point Calibration |
| Pump | Smartpump™ Adjustable Pressure Output |
| Communication | RS232, Optional RS485/Profibus |
| External Sensor Interface | Integrated Pt100 Input |
| Safety Features | Low-Level Detection, Overtemperature Cut-off, IP65 Waterproof Keypad |
| Power Supply | 230 V / 50 Hz / 12 A |
| Refrigerant | R134a (GWP = 1430) |
| Cooling Method | Air-Cooled Single-Stage Compressor |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), Classification III (FL) |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | F25-MA |
| Bath Volume | 4.5 L |
| Temperature Range | −28 °C to +200 °C |
| Temperature Stability | ±0.02 °C |
| Control Method | PID2 |
| Calibration | ATC3 Three-Point Calibration |
| Pump Flow Rate | 11–16 L/min |
| Max. Pump Pressure | 0.45 bar |
| Heating Power | 2 kW |
| Refrigeration Power | 0.6 kW at −20 °C |
| Refrigerant | R134a (GWP = 1430) |
| Communication Interface | RS232 |
| Safety Classification | DIN 12876-1 Class III (FL) |
| Dimensions (W×L×H) | 23 × 42 × 61 cm |
| Weight | 31 kg |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | F25-ME |
| Temperature Range | -28 to +200 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 4.5 L |
| Circulation Type | Internal & External |
| Control Mode | Heating & Cooling |
| Heating Power | 2 kW |
| Refrigeration Power | 0.26 kW (at 20 °C), 0.2 kW (at 0 °C), 0.6 kW (at −20 °C) |
| Pump Flow Rate | 11–16 L/min |
| Pump Pressure | 0.23–0.45 bar |
| Display | VFD LCD |
| Control Algorithm | PID3 with ATC3 three-point calibration |
| External Sensor Interface | PT100 |
| Communication | RS232 |
| Safety Features | Low-level detection, overtemperature cutoff, adjustable alarm threshold |
| Compressor Refrigerant | R134a (GWP 1430) |
| DIN 12876-1 Classification | Class III (FL) |
| Dimensions (W×L×H) | 23 × 42 × 61 cm |
| Weight | 31 kg |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | F32-MA |
| Bath Volume | 8 L |
| Temperature Range | −35 °C to +200 °C |
| Temperature Stability | ±0.02 °C |
| Control Method | PID2 |
| Calibration | ATC3 Three-Point Calibration |
| Pump Flow Rate | 11–16 L/min |
| Max. Pump Pressure | 0.45 bar |
| Heating Power | 2 kW |
| Refrigeration Power (at 20/0/−20/−30 °C) | 0.45/0.39/0.15/0.06 kW |
| Compressor Type | Single-stage, R134a |
| Communication Interface | RS232 (optional Profibus) |
| Safety Classification | DIN 12876-1 Class III (FL) |
| Dimensions (W×L×H) | 31 × 42 × 64 cm |
| Weight | 37 kg |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | F34-HE |
| Temperature Range | −30 to +150 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 20 L |
| Circulation Type | Internal & External |
| Control Mode | Heating & Cooling |
| Display | VFD White High-Brightness LCD |
| Temperature Calibration | ATC3 Three-Point Calibration |
| Pump Control | SmartPump™ Adjustable Pressure |
| Communication Interface | RS232 |
| External Sensor Input | PT100 |
| Safety Features | Low-Level Detection, Over-Temperature Alarm, Auto-Shutdown |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | F34-HL |
| Bath Volume | 20 L |
| Temperature Range | −30 to +150 °C |
| Temperature Stability | ±0.01 °C |
| Circulation Type | Internal & External |
| Cooling/Heating Mode | Dual-function |
| Display | VFD + Backlit LCD |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Heating Power | 2 kW |
| Refrigeration Power (at 20 °C) | 0.45 kW |
| Refrigerant | R134a (GWP = 1430) |
| Compressor Type | Air-cooled, Single-stage |
| Communication Interfaces | RS232, RS485 (optional), Profibus (optional) |
| External PT100 Input | Integrated |
| Temperature Calibration | ATC3 Three-point Calibration |
| Control Algorithm | ICC (Intelligent Climate Control) with Auto-tuning |
| Programmability | 6 programs × 60 steps |
| Safety Features | Low-level detection, Overtemperature alarm & shutdown, Leak-resistant keypad |
| Dimensions (W×L×H) | 36 × 46 × 71 cm |
| Weight | 45 kg |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | F81-HL |
| Temperature Range | -81 to +100 °C |
| Temperature Stability | ±0.02 °C |
| Bath Volume | 6.5 L |
| Circulation Type | Internal & External |
| Control Technology | ICC (Intelligent Cascade Control) with ATC3 Three-Point Calibration |
| Display | VFD + Backlit LCD |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Heating Power | 1.3 kW |
| Refrigeration Power (at -80 °C) | 0.07 kW |
| Communication Interfaces | RS232, RS485 (optional Profibus) |
| Safety Compliance | DIN 12876-1 Class III (FL) |
| External Pt100 Input | Integrated |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | F81-ME |
| Temperature Range | −81 °C to +100 °C |
| Temperature Stability | ±0.02 °C |
| Bath Volume | 6.5 L |
| Circulation Type | Internal & External |
| Control Mode | Heating & Refrigeration |
| Display Resolution | 0.01 °C |
| Heating Power | 1.3 kW |
| Refrigeration Power | 0.45 kW |
| Pump Flow Rate | 11–16 L/min |
| Max. Pump Pressure | 0.45 bar |
| Bath Opening (W × L × D) | 13 × 15 × 16 cm |
| Internal Diameter | 10 mm |
| Refrigerant | R404A (300 g) + R23 (200 g) |
| Compressor | Two-stage air-cooled |
| DIN 12876-1 Classification | Class III (FL) |
| Communication Interface | RS232 |
| External Pt100 Input | Integrated |
| Programming Capacity | 1×10-step ramp/soak |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | F95-SL |
| Temperature Range | −95 to 0 °C |
| Temperature Stability | ±0.05 °C |
| Bath Volume | 22 L |
| Heating Power | 3 kW |
| Refrigeration Power (at −80 °C) | 0.36 kW |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Display Resolution | 0.01 °C |
| Control Technology | ICC + TCF + ATC3 |
| Communication Interfaces | RS232, RS485 (optional Profibus) |
| Refrigerants | R404A (1st stage), R23 (2nd stage) |
| DIN 12876-1 Classification | Class III (FL) |
| Cooling Method | Air-cooled |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | FK25-HL / FK50-HL / FK89-HL |
| Temperature Range | –90 °C to +200 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Uniformity | ±0.01 °C |
| Bath Volume | 4.5 L / 8 L / 8 L |
| Circulation Type | Internal & External |
| Pump Flow Rate | 22–26 L/min |
| Max. Pressure | 0.4–0.7 bar |
| Display | Triple VFD (Actual / Setpoint / Reference) |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FP40-HE |
| Temperature Range | −40 to +200 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 16 L |
| Circulation Type | Internal & External |
| Control Mode | Heating & Refrigeration |
| Display | VFD |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Refrigerant | R404A (GWP = 3922) |
| Power Supply | 230 V / 50 Hz / 13 A |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FP40-HL |
| Bath Volume | 16 L |
| Temperature Range | −40 °C to +200 °C |
| Temperature Stability | ±0.01 °C |
| Circulation Type | Internal & External |
| Control Technology | ICC + TCF + ATC3 |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Refrigerant | R134a |
| Classification | DIN 12876-1 Class III (FL) |
| Communication | RS232, RS485, optional Profibus |
| External Pt100 Interface | Integrated |
| Power Supply | 230 V / 50–60 Hz |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | FP45-HE |
| Bath Volume | 26 L |
| Temperature Range | −42 °C to +200 °C |
| Temperature Stability | ±0.01 °C |
| Circulation Type | Internal & External |
| Cooling/Heating Mode | Dual-function |
| Refrigerant | R134a (GWP = 1430) |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Heating Power | 2 kW |
| Refrigeration Power (at −40 °C) | 0.28 kW |
| Display | VFD + Backlit LCD |
| Control Technology | ICC (Intelligent Cascade Control), TCF (Temperature Control Function), ATC3 (3-Point Calibration) |
| Communication Interfaces | RS232, RS485 (optional Profibus), Solenoid Valve Port, Analog I/O Option |
| External Pt100 Input | Integrated |
| Programmable Ramp/Soak | 6×60-step |
| Safety Features | Low-level detection, Overtemperature alarm, Auto-shutdown, IP20 enclosure rating |
| Ambient Operating Temperature | 5–40 °C |
| Dimensions (W×L×H) | 36 × 46 × 71 cm |
| Weight | 45 kg |
| Compressor Type | Air-cooled, single-stage |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FP50-ME |
| Temperature Range | -50 to +200 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 8 L |
| Circulation Type | Internal & External |
| Control Mode | Heating & Refrigeration |
| Heating Power | 2 kW |
| Refrigeration Power (at 20/0/−20/−40 °C) | 0.9 / 0.8 / 0.5 / 0.16 kW |
| Pump Flow Rate | 11–16 L/min |
| Pump Pressure | 0.23–0.45 bar |
| Display | VFD |
| Control Algorithm | PID with Cascade Logic |
| Calibration | ATC3 Three-Point Calibration |
| Communication Interface | RS232 (optional Profibus) |
| Safety Classification | DIN 12876-1 Class III (FL) |
| Refrigerant | R404A (GWP 3922, CO₂-eq 1.51 t) |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FP51-SL / FP52-SL / FP55-SL |
| Temperature Range | −51 °C to +200 °C |
| Temperature Stability | ±0.05 °C |
| Bath Volume | 11 L |
| Circulation Type | Internal & External |
| Control Mode | Heating & Refrigeration |
| Display | VFD + LCD Backlit |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Refrigerant | R404A (GWP 3985) |
| Safety Class | DIN 12876-1 Class III (FL) |
| Communication Interface | RS232, Optional RS485/Profibus |
| External Pt100 Input | Yes |
| Programmable Steps | 6 × 60 |
| ATC3 Three-Point Calibration | Yes |
| ICC Auto-Tuning & TCF Adaptive Control | Yes |
| SmartPump™ Variable Power Adjustment | Yes |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FP52-SL-150C / FP55-SL-150C |
| Bath Volume | 24 L / 27 L |
| Temperature Range | −60 °C to +150 °C |
| Temperature Stability | ±0.05 °C |
| Display Resolution | 0.01 °C |
| Heating Power | 3 kW (FP52), 5.5 kW (FP55) |
| Refrigeration Power (at −60 °C) | 0.1 kW (FP52), 0.13 kW (FP55) |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Refrigerant | R404A |
| GWP | 3922 |
| DIN 12876-1 Classification | Class III (FL) |
| Communication Interfaces | RS232, RS485 (optional Profibus) |
| Programmable Ramp/Soak | 6×60 steps |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FP90-SL |
| Bath Volume | 22 L |
| Temperature Range | -90 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Control Resolution | 0.01 °C |
| Heating Power | 3 kW |
| Refrigeration Power (at -80 °C) | 0.15 kW |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Communication Interfaces | RS232, RS485 (optional), Profibus (optional) |
| External Pt100 Input | Integrated |
| Safety Classification | DIN 12876-1 Class III (FL) |
| Refrigerants | R404A (1st stage, 850 g, GWP 3922), R23 (2nd stage, 380 g, GWP 14800) |
| Cooling Method | Air-cooled dual-stage compression |
| Weight | 195 kg |
| Dimensions (W×L×H) | 59 × 76 × 116 cm |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FP90-SL-150C |
| Temperature Range | -90 to +150 °C |
| Temperature Stability | ±0.05 °C |
| Bath Volume | 22 L |
| Circulation Type | Internal & External |
| Control Mode | Heating & Refrigeration Dual Function |
| Display | VFD + LCD Backlit |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Heating Power | 3 kW |
| Refrigeration Power (at -80 °C) | 0.15 kW |
| Compressor Stages | Two-stage (R404A / R23) |
| Communication Interface | RS232, RS485 (optional Profibus) |
| Compliance | DIN 12876-1 Class III (FL) |
| Weight | 195 kg |
| Dimensions (W×L×H) | 59 × 76 × 116 cm |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FPW50-HE |
| Temperature Range | -50 to +200 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 8 L |
| Circulation Type | Internal & External |
| Control Technology | ICC (Intelligent Control Circuit) |
| Display | VFD White High-Brightness LCD |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Heating Power | 2 kW |
| Refrigeration Power (Ethanol, 20 °C) | 0.9 kW |
| Refrigerant | R404A (GWP 3922) |
| Weight | 57 kg |
| Dimensions (W×L×H) | 42 × 49 × 72 cm |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FPW50-HL |
| Temperature Range | −50 to +200 °C |
| Temperature Stability | ±0.01 °C |
| Bath Volume | 8 L |
| Circulation Type | Internal & External |
| Control Technology | ICC (Intelligent Control Circuit) + TCF (Temperature Control Function) |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Heating Power | 2 kW |
| Refrigeration Power (at 20 °C) | 0.9 kW |
| Refrigerant | R404A (GWP 3922) |
| Display | VFD + Backlit LCD |
| Communication | RS232, RS485 (optional Profibus), Integrated Pt100 Input |
| Programming | 6 programs × 60 steps |
| Safety | Low-level detection, Overtemperature cutoff, DIN 12876-1 Class III (FL) certified |
| Cooling Method | Water-cooled compressor |
| Dimensions (W×L×H) | 42 × 49 × 70 cm |
| Weight | 57 kg |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | FPW52-SL-150C / FPW55-SL-150C |
| Bath Volume | 24 L |
| Temperature Range | –60 °C to +150 °C |
| Temperature Stability | ±0.05 °C |
| Temperature Resolution | 0.01 °C |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Refrigerant | R404A (GWP 3922) |
| Compressor Cooling | Water-cooled |
| Compliance | DIN 12876-1 Class III (FL) |
| Communication Interfaces | RS232, RS485, optional Profibus |
| External PT100 Input | Integrated |
| Programmable Steps | 6 × 60 |
| Heating Power | 3 kW |
| Refrigeration Power (at –60 °C) | 0.1 kW (FPW52), 0.13 kW (FPW55) |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FPW55-SL |
| Temperature Range | -60 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Bath Volume | 27 L |
| Pump Flow Rate | 22–26 L/min |
| Max. Pump Pressure | 0.7 bar |
| Refrigerant | R404A (GWP 3922) |
| Compressor Cooling | Water-cooled |
| Compliance | DIN 12876-1 Class III (FL) |
| Control Resolution | 0.01 °C |
| External PT100 Input | Integrated |
| Communication Interfaces | RS232, RS485, optional Profibus |
| Programmable Ramp/Soak | 6×60 steps |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model | FPW90-SL |
| Temperature Range | −90 °C to +100 °C |
| Temperature Stability | ±0.05 °C |
| Display Resolution | 0.01 °C |
| Heating Power | 3 kW |
| Refrigeration Power (at 20 °C / 0 °C / −20 °C / −40 °C / −60 °C / −80 °C) | 1.8 / 1.7 / 1.6 / 1.35 / 0.75 / 0.15 kW |
| Pump Flow Rate | 22–26 L/min |
| Pump Pressure | 0.4–0.7 bar |
| Pump Suction | 0.2–0.4 bar |
| Internal Bath Volume | 22 L |
| Refrigerant System | Two-stage cascade (R404A + R23) |
| Communication Interfaces | RS232, RS485 (optional Profibus) |
| Safety Classification | DIN 12876-1 Class III (FL) |
| Cooling Method | Water-cooled compressor |
| External PT100 Input | Integrated |
| Programmable Steps | 6 programs × 60 steps each |