| Brand | Kyoritsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | WAK-COD(H)-2 |
| Price Range | USD 21–40 |
| Brand | Kyoritsu |
|---|---|
| Origin | Japan |
| Product Type | Imported Portable Reagent Test Kit |
| Model | WAK-Cu |
| Detection Principle | Colorimetric Dip-and-Read Paper Strip Method |
| Target Analyte | Copper (Cu²⁺) |
| Measurement Range | 0.5–10 mg/L (as Cu) |
| Reaction Time | 1 minute |
| Tests per Kit | 50 |
| Accuracy | ±0.2 mg/L at low end |
| Compliance | Designed for field-deployable screening in accordance with ISO 8692 (water quality — test for toxicity to freshwater algae), ASTM D1688 (copper in water by colorimetric methods), and EPA Method 9040C (screening for metals using solid-phase reagents) |
| Brand | Kyoritsu |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | WAK-PO4 Total Phosphorus Colorimetric Test Kit |
| Price Range | USD 34–39 |
| Measured Parameter | Total Phosphorus |
| Instrument Type | Laboratory |
| Measurement Principle | Ascorbic Acid-Molybdate Blue Colorimetry |
| Measurement Range | 0.2–10 mg/L as P |
| Brand | Kyoritsu |
|---|---|
| Origin | Japan |
| Product Type | Imported Reagent-Based Water Quality Test Kit |
| Model | WAK-PO4(D) |
| Measurement Parameter | Orthophosphate (as PO₄³⁻) and Phosphate Phosphorus (as P) |
| Detection Range | 0.05–2 mg/L (as PO₄³⁻) |
| Reaction Time | 5 minutes |
| Test Capacity | 50 determinations per kit |
| Instrument Category | Laboratory-Use Colorimetric Test Kit |
| Measurement Principle | Ascorbic Acid-Molybdate Blue Method (Standard Spectrophotometric Color Development) |
| Brand | Kyoritsu |
|---|---|
| Origin | Japan |
| Model | WAK-COD-WR |
| Measurement Range | 0, 10, 100, 500, 1000, 2000, 10000+ mg/L COD |
| Reaction Time | 1 minute |
| Tests per Kit | 50 |
| Compliance | JIS K 0102, ISO 6060, ASTM D1253 |
| Brand | Kyoritsu |
|---|---|
| Origin | Japan |
| Model | WAK-F Fluoride Ion Test Kit |
| Test Range | 0.1, 0.2, 0.5, 1, 2, 5 mg/L (as F⁻) |
| Reaction Time | 5 minutes |
| Tests per Kit | 50 |
| Compliance | ISO 10304-1 (ion chromatography reference), JIS K 0102 (Japanese Industrial Standard for water analysis), EPA Method 300.0 (fluoride ion selective electrode reference) |
| Brand | Kyoritsu |
|---|---|
| Origin | Japan |
| Model | WAK-NH4(C)-4 |
| Measurement Range | 0, 0.5, 1, 2, 5, 10, 20 mg/L NH₄⁺-N |
| Reaction Time | 10 minutes |
| Test Capacity | 50 determinations per kit |
| Instrument Type | Portable |
| Intended Use | Wastewater effluent monitoring |
| Principle | Colorimetric (Indophenol Blue Method) |
| Compliance | Designed for field-deployable screening aligned with ISO 7150-1 and EPA Method 350.1 guidelines |
| Brand | Kyoritsu |
|---|---|
| Origin | Japan |
| Product Type | Imported Reagent-Based Colorimetric Test Kit |
| Model | WAK-Ni(D) |
| Detection Range | 0.3, 0.5, 1, 2, 5, 10 mg/L Ni²⁺ |
| Reaction Time | 2 minutes |
| Tests per Kit | 50 |
| Compliance | Designed for field and lab use in accordance with ISO 8573-1 (water quality — determination of nickel — spectrophotometric method after complexation with dimethylglyoxime) principles |
| Measurement Principle | Visual or spectrophotometric colorimetry based on nickel–dimethylglyoxime (DMG) chelation |
| Brand | Kyoritsu |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WAK-TN-i-3 |
| Measuring Parameter | Total Inorganic Nitrogen (TIN) |
| Instrument Type | Laboratory-Use Colorimetric Test Kit |
| Measurement Principle | Cadmium Reduction + Diazotization-Coupling Spectrophotometry (Standardized Derivative of ISO 11908 & ASTM D1426) |
| Measurement Range | 0–100 mg/L as N |
| Reaction Time | 20 minutes |
| Test Capacity | 40 determinations per kit |
| pH Compatibility | 0–100 (non-applicable — corrected to assay buffer-controlled range: pH 6.5–7.5 during reaction) |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-100(8)js |
| Digestion Method | Reflux Digestion |
| Batch Capacity | 8 samples |
| Temperature Setting | 165 °C (per GB 11914–1989 and ISO 6060) |
| Temperature Accuracy | ±1 °C at 165 °C |
| Sample Vessel Compatibility | 250 mL conical flasks or cylindrical digestion vials |
| Timer Range | 0–999 minutes (adjustable in 1-minute increments) |
| Heating Power | 1300 W (AC 220 V ±10 %, 50 Hz) |
| Cooling Method | Forced-air convection (no tap water required) |
| Condenser Type | Glass spiky reflux condenser |
| Measuring Range | 0–1000 mg/L (direct) |
| Precision | RSD ≤5.0% for potassium hydrogen phthalate (500 mg/L) |
| Operating Ambient | 5–40 °C |
| Compliance | Fully aligned with GB 11914–1989, ISO 6060:1989, and EPA Method 410.4 |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-1005 |
| Digestion Method | Reflux Digestion |
| Heating Module | Integrated Ceramic Heating Block |
| Batch Capacity | 5 × 250 mL Erlenmeyer Flasks |
| Temperature Setpoint | 165 °C (per GB 11914–1989 and ISO 6060) |
| Temperature Accuracy | ±1 °C at 165 °C |
| Timer Range | 0–999 min |
| COD Measurement Range | 0–1000 mg/L (direct), 0–10000 mg/L (after dilution) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 1300 W |
| Ambient Operating Temperature | 5–40 °C |
| Cooling Method | Forced-air convection (no tap water required) |
| Condenser Type | Glass “spike” reflux condenser (replaces spherical condenser) |
| Compliance | Fully aligned with GB 11914–1989, ISO 6060:1989, and EPA Method 410.4 principles |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Laboratory-grade |
| Model | KY-102(12) |
| Heating Method | Electric heating plate with microcomputer timing control |
| Cooling Method | Air-cooled condenser with static water assist at condensate outlet |
| Digestion Vessels | 12 × 250 mL ground-glass (24/29) conical flasks |
| Digestion Time Range | 10 min – 150 min |
| Temperature Control | Surface temperature display per selected power level |
| Power Rating | ≤2500 W (AC 220 V, 50 Hz) |
| Compliance | HJ 828–2017 |
| Measuring Range | 10–700 mg/L COD (dilution required for samples >700 mg/L) |
| Precision | RSD ≤5.0% for potassium hydrogen phthalate standard (500 mg/L) |
| Ambient Operating Temperature | ≤35 °C |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM System Integrator |
| Origin Category | Imported |
| Model | AutoBOD-60 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Dissolved Oxygen (DO) Depletion Method |
| Measurement Range | 2–4000 mg/L BOD₅ |
| Detection Limit | 5 mg/L BOD₅ |
| Accuracy | ±5% (relative to reference standard) |
| Single-Sample Cycle Time | 60 min |
| Repeatability | ±3% RSD |
| Sample Vessel | 300 mL Wheaton borosilicate glass BOD bottle |
| Throughput | 60 samples per run |
| Probe Type | Polarographic or optical DO sensor (user-configurable) |
| Cleaning Protocol | Automated probe rinse with deionized water between measurements |
| Software Control | Labman BODSoft v4.x (Windows-based, audit-trail enabled) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BOD-990-D20C |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Microbial Electrode Method |
| Measurement Range | 0–4000 mg/L |
| Detection Limit | 0.001 mg/L |
| Accuracy | ±0.1 mg/L |
| Single-Sample Measurement Time | 45 s |
| Repeatability | ±0.1 mg/L |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | XJT16-20W |
| Digestion Method | Rapid Digestion |
| Heating Module | Dual Graphite Heating Blocks |
| Batch Capacity | 16 × 100 mL |
| Temperature Range | 0–220 °C |
| Temperature Accuracy | ±0.2 °C |
| Timer Accuracy | ±0 s |
| Sample Well Diameter × Depth | Φ44 × 50 mm |
| Heating Block Dimensions (L×W×H) | 355 × 301 × 240 mm |
| Power Supply | 220 V / 50 Hz |
| Heating Material | High-Purity Graphite with PTFE Coating |
| Max. Power Consumption | 1500 W |
| Temperature Resolution | 0.1 °C |
| Inter-Well Uniformity | ±1.5 °C |
| Single-Well Temp. Stability | ±0.5 °C |
| Continuous Operation Duration | >48 h |
| Brand | Chelsea |
|---|---|
| Origin | UK |
| Model | LabSTAF |
| Excitation Wavelengths | 417, 452, 472, 505, 534, 594, 622 nm |
| Actinic Light Range | 10–2400 µmol photons·m⁻²·s⁻¹ (12-bit resolution) |
| Detection Limit | 0.001 mg/m³ Chl-a |
| Sample Chamber | 20 mL quartz vertical cylinder with BK7 base |
| Power Supply | 24 VDC, 140–400 mA (3.4–9.7 W) |
| Dimensions (H×D×W) | 235 × 320 × 420 mm |
| IP Rating | IP65 |
| Weight | 8.1 kg |
| Brand | SYSTEA |
|---|---|
| Model | LabTox |
| Measurement Principle | Bioluminescent Bacterial Toxicity Assay (using *Aliivibrio fischeri*, *Photobacterium phosphoreum*, or *Vibrio qinghaiensis* Q67) |
| Compliance | ISO 11348-3, GB/T 15441 |
| Throughput | Up to 30 samples/hour |
| Sample Capacity | 80-position carousel |
| Dilution Range | Up to 160-fold automated serial dilution (EC50 mode) |
| Dual-Parallel Testing | Blank + sample replicates (inhibition mode) |
| Integrated Cleaning Station | On-board probe and cuvette washing with programmable rinse cycles |
| Software | Windows-based control & analysis suite with audit trail, user management, and data export (CSV, PDF, Excel) |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | 1500-U |
| Instrument Type | Single-Wavelength Absorbance Photometer |
| Measurement Range | 0–6.00 mg/L Urea |
| Resolution | 0.01 mg/L |
| Photometric Accuracy | ±0.001 Abs |
| Detection Method | Enzymatic Transaminase Colorimetric Assay (No Boiling Required) |
| Display | 3.5-inch Digital LCD |
| Response Time | <2 s |
| Detector | Silicon Photodiode |
| Light Source | LED |
| Sample Cell | Integrated Cuvette Holder for 25 mm Round Glass Cuvettes |
| Interface | RS232 |
| Certifications | EPA-Compliant Method, CE Marked |
| IP Rating | IP67 (Waterproof & Dustproof) |
| Power | 9 V Alkaline Battery or AC/DC Adapter |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | 1761 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Galvanic Cell Probe |
| Measurement Range | 0–20.00 ppm (mg/L) |
| Accuracy | ±2% FS (DO), ±1.8°F (±1°C) (Temperature) |
| Resolution | 0.01 ppm (DO), 0.1°F/°C (Temperature) |
| Repeatability | ±4% |
| Detection Limit | ±2% FS |
| Altitude Compensation | 0–20,000 ft (in 1,000-ft increments) |
| Salinity Compensation | 0–50 ppt |
| Data Storage | 25 DO + temperature datasets |
| Power | Four 1.5V SR44W batteries |
| Dimensions | 1.4 × 6.9 × 1.6 in (36 × 176 × 41 mm) |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | 2020we |
| Instrument Type | Portable/Handheld Turbidimeter |
| Measurement Parameter | Turbidity |
| Compliance Standards | EPA Method 180.1 (tungsten lamp), ISO 7027 (860 nm LED) |
| Measurement Units | NTU, FNU, AU, ASBC, EBC |
| Range | 0–4000 NTU/FNU, 0–10,500 ASBC, 0–150 EBC |
| Resolution | 0.01 NTU/FNU (0–10.00), 0.1 NTU/FNU (10.00–10.99), 1 NTU/FNU (11.00–109.9), 1 NTU/FNU (110–4000) |
| Accuracy | ±0.05 NTU/FNU (0–2.5), ±2% (2.5–100), ±3% (>100) |
| Detection Limit | 0.05 NTU/FNU |
| Repeatability | ±0.02 NTU/FNU or ±1% |
| Light Source | Tungsten lamp (EPA mode), 860 nm LED (ISO mode) |
| Enclosure Rating | IP67 |
| Power | Rechargeable Li-ion battery |
| Interface | USB |
| Display | Backlit LCD |
| Language Support | 7 languages |
| Calibration | Automatic range selection, NIST-traceable standards compatible |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | COD3 PLUS |
| Instrument Type | Portable |
| Measurement Principle | UV-Vis Absorption Spectrophotometry (LED-based, dual-wavelength) |
| Wavelengths | 430 nm & 620 nm |
| Optical Range | 0–125% Transmittance (T) |
| Accuracy | ±2% Full Scale (FS) |
| Repeatability | ≤±5% |
| Detection Limit | 0.1 ppm |
| Measurement Time | 30 seconds |
| Batch Capacity | 1 sample per run |
| Light Source | High-stability LEDs with optical filters |
| Detector | Silicon photodiode |
| Display | 160 × 100 pixel backlit LCD (20 × 6 character graphical interface) |
| Sample Cells | 25 mm round cuvette, 10 mm square cell, 16 mm COD digestion vial |
| Power | Rechargeable Li-ion battery (500 tests per charge) or USB-powered operation |
| Data Storage | 500 timestamped measurement records with date/time stamp |
| Connectivity | USB interface for data export |
| Dimensions | 19.05 × 8.89 × 6.35 cm (7.5 × 3.5 × 2.5 in) |
| Weight | 453 g (16 oz) |
| Language Support | English, French, Spanish, Japanese, Italian, Portuguese, Chinese |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | Color Q |
| Detection Parameters | Free Chlorine (0–10 mg/L), Total Chlorine (Low Range: 0–10 mg/L |
| High Range | 0–750 mg/L) |
| Resolution | 0.01 mg/L |
| Test Capacity | 50 tests per reagent set (low range), 50 tests per high-range liquid reagent vial |
| Optical Design | Dual-wavelength photometric system |
| Reagent Format | DPD effervescent tablets (low range), stabilized liquid DPD reagent (high range) |
| Enclosure Rating | IP57 |
| Display | Backlit digital LCD |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | Color Q PRO-7 |
| Power | 2 × AA batteries (included) |
| Auto-off | 5 min |
| IP Rating | IP67 (waterproof) |
| Warranty | 6 months |
| Language Support | English, Spanish, French |
| Measurement Principle | Reflectance photometry with pre-programmed colorimetric methods |
| Compliance | Designed to meet ASTM D1293 (pH), D511 (calcium), D859 (cyanuric acid), and EPA-compliant chlorine/bromine test chemistries |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | DC-1500UDV |
| Type | UV-Vis Absorbance-Based Concentration Analyzer for Mold Release Agents |
| Compliance | Designed for industrial process control and QC labs in die-casting, composite manufacturing, and precision molding environments |
| Enclosure Rating | IP65-rated housing for splash resistance |
| Optical System | Fixed-wavelength UV-Vis photometer (254 nm and 546 nm dual-channel capability) |
| Detection Principle | Beer-Lambert law-based absorbance measurement calibrated for proprietary demoldant formulations |
| Calibration | Factory-calibrated with NIST-traceable standards |
| Sample Cell | Sealed, quartz-cuvette-style flow-through cell with O-ring sealing and chemical-resistant PTFE wetted surfaces |
| Power | 100–240 VAC, 50/60 Hz, internal switching power supply |
| Interface | Backlit LCD with tactile keypad |
| Data Storage | Internal memory for up to 500 test records with timestamp, operator ID, and calibration history |
| Brand | LaMotte |
|---|---|
| Origin | USA |
| Model | DC1200-CL |
| Instrument Type | Portable |
| Measurement Principle | DPD Colorimetric Method (EPA-Compliant) |
| Measuring Parameter | Free Chlorine |
| Range | 0.00–4.00 mg/L |
| Accuracy | ±0.01 mg/L |
| Repeatability | ±0.02 mg/L |
| Resolution | 0.01 mg/L |
| LOD | 0.025 mg/L |
| Optical Precision | ±0.001 Absorbance Units |
| Response Time | 2 s |
| Light Source | LED |
| Detector | Silicon Photodiode |
| Wavelength | Single-Wavelength (530 nm typical for DPD) |
| Cuvette | 25 mm square, flat-bottom, capped |
| Display | 3.5-digit LCD |
| Power | 9 V alkaline battery or optional AC adapter (220 V / 50 Hz) |
| Dimensions | 8.5 × 16.2 × 6.7 cm |
| Weight | 312 g |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −40 to +60 °C |
| Relative Humidity | 0–90 % RH (non-condensing) |
| Certifications | CE |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | DC1500 |
| Detection Range | 0–4.00 ppm (mg/L) |
| Detection Limit | 0.03 ppm |
| Wavelength Accuracy | ±2% FS |
| Bandwidth | 10 nm |
| Light Source | LED |
| Detector | Silicon Photodiode with Integrated Interference Filter |
| Display | 160 × 100-pixel Backlit LCD (20 × 6-character + graphical) |
| Sample Cell | 25 mm Diameter Flat-Bottom Cuvette |
| Power | Rechargeable Li-ion Battery (3.7 V, 2.5" × 0.75") |
| Interface | Mini-USB |
| Ingress Protection | IP67 |
| Compliance | EPA Method 330.5, Standard Methods 4500-Cl, NPDWR & NPDES Requirements |
| Software Compatibility | Optional Data Management Software with Audit Trail Support |
| Auto-Power-Off | Configurable (5 / 10 / 50 min) |
| Language Options | 7 Languages Including English and Chinese |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | DC1500 |
| IP Rating | IP67 |
| Display | 160 × 100 backlit graphical LCD (20 × 6 character lines) |
| Wavelength Accuracy | ±2% FS |
| Bandwidth | 10 nm (typical) |
| Light Source | LED |
| Detector | Silicon photodiode with integrated interference filter |
| Measurement Modes | Pre-programmed methods, Absorbance, % Transmittance |
| Languages | English, Spanish, French, Portuguese, Italian |
| Sample Cell | 25 mm diameter flat-bottom cuvette |
| Interface | Mini-USB |
| Power | Rechargeable lithium-ion battery (3.7 V, 2.5 Ah) |
| Battery Life | ~380 tests with backlight enabled |
| Auto-off Options | Disabled, 5, 10, or 50 minutes |
| Compliance | CE Marked |
| Test Kits Supported | DPD-based free/total chlorine (e.g., catalog #3240-DC1500-CL0, range 0–4.00 mg/L, LOD 0.05 mg/L), chlorine dioxide (e.g., #3240-DC1500-CLO2-LI, liquid reagent format) |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | DC1500-DD |
| Detection Parameters | Free Chlorine & Total Chlorine (0.00–4.00 mg/L), Chlorine Dioxide (0.00–8.00 mg/L), Ozone (Low Range: 0.00–0.40 mg/L |
| High Range | 0.00–2.50 mg/L) |
| Display | 160 × 100 backlit LCD, 20 × 6 character graphic display |
| Wavelength Accuracy | ±2% FS |
| Bandwidth | 10 nm |
| Light Source | LED with integrated narrow-band interference filter |
| Detector | Silicon photodiode |
| Sample Cell | 25 mm diameter round-bottom cuvette |
| Power | Rechargeable lithium-ion battery (3.7 V, 2.5 × 75 mm, 1.7 oz), AC adapter, or USB bus power |
| Battery Life | Up to 380 tests (backlight on) or 1000 tests (backlight off) |
| Auto-off | Disabled, 5, 10, or 50 minutes |
| IP Rating | IP67 |
| Certifications | CE |
| Interface | Mini-USB |
| Languages | English, Spanish, French, Portuguese, Italian, Chinese, Japanese |
| Dimensions (Shipping) | 17 × 16 × 9 in |
| Weight (Shipping) | 8 lb |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | SMART |
| Wavelength Range | 350–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Resolution | 1 nm |
| Bandwidth | 4 nm |
| Photometric Range | 0–125%T, −0.3–2.500 A |
| Photometric Accuracy | ±0.005 A |
| Photometric Noise | <0.001 A (at 0 A), <0.002 A (at 2 A) |
| Stray Light | ≤0.4%T at 360 nm |
| Optical System | Modified Ebert design with 1200 lines/mm grating |
| Light Source | 12 V / 10 W quartz-halogen lamp (≥1000 h lifetime) |
| Detector | Silicon photodiode |
| Sample Holders | 25 mm round cuvettes, 10 mm square cuvettes, COD vials (with adapters) |
| Display | 5.1-inch high-contrast LCD |
| Data Storage | 1000 measurements |
| Interface | USB |
| Power | 12 V DC adapter or optional rechargeable battery pack |
| Dimensions | 350 × 280 × 170 mm |
| Weight | 4.65 kg |
| Certifications | CE |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | SMART Spectro |
| Instrument Type | Laboratory Water Quality Analyzer |
| Wavelength Range | 350–1000 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Resolution | 1 nm |
| Bandwidth (FWHM) | 5 nm |
| Photometric Range | 0–125%T, –0.1–2.5 A |
| Absorbance Accuracy | ±0.005 A |
| Optical Noise | <0.001 A at 0 A |
| Drift | ±0.002 A/hr @ 500 nm |
| Stray Light | <0.5% T |
| Grating Density | 1200 lines/mm |
| Optical Design | Modified Ebert monochromator |
| Light Source | Quartz-halogen lamp (≥1000 h lifetime) |
| Detector | Silicon photodiode |
| Cuvette Compatibility | 10 mm square, 25 mm round, COD vials, flow-through cell (optional) |
| Display & Interface | Menu-driven LCD with scroll navigation |
| Data Output | RS-232 serial port |
| Power Supply | 115/230 V AC or rechargeable battery |
| Built-in Diagnostics | Yes |
| Preprogrammed Methods | >80 |
| User-Defined Methods | Up to 25 |
| Measurement Modes | Absorbance (A), Transmittance (%T), Concentration (mg/L, ppm, etc.) |