| Brand | MN |
|---|---|
| Origin | Germany |
| Model | 904 Series |
| Format | Individual strips, 200 per box |
| Dimensions | 11 × 100 mm |
| pH Range Options | 0–1.8 to 12–14.0 |
| Increment Resolution | 0.2–0.5 pH units (model-dependent) |
| Application-Specific Calibration | Optimized for colored aqueous samples |
| Brand | MN |
|---|---|
| Origin | Germany |
| Model | PF-12 |
| Instrument Type | Laboratory & Field-Portable Photometer |
| Detection Parameters | Heavy Metals (e.g., Cr, Cu, Pb, Cd, Ni), COD, Ammonia, Nitrate, Nitrite, Total Phosphorus, Total Nitrogen, Chlorine, pH (via compatible test kits), Turbidity (via VISOCOLOR ECO/NANOCOLOR methods) |
| Wavelength Range | 345 / 436 / 470 / 540 / 585 / 620 / 690 nm (±2 nm accuracy) |
| Optical System | Microprocessor-Controlled Single-Beam Filter Photometer with 7-Position Filter Wheel |
| Light Source | Tungsten Halogen Lamp |
| Detector | Silicon Photodiode |
| Photometric Range | ±3 Absorbance Units (E) |
| Accuracy | ±1% of reading |
| Stability | <0.002 E/h |
| Sample Format | 16 mm Round Cuvettes |
| Data Storage | 200 GLP-Compliant Records (including sample ID, location, dilution factor, date/time, operator ID) |
| Display | Backlit LCD (64 × 128 pixels) |
| Interface | USB 2.0 (data transfer, firmware update, power supply) |
| Power Options | USB bus power, 4× AA alkaline/rechargeable batteries (≥2000 measurements per charge), 12 V automotive adapter (REF 919 220), optional charger (REF 919 221) |
| Environmental Rating | IP67 |
| Operating Temp. | 0–50 °C |
| Dimensions | 215 × 100 × 65 mm |
| Weight | 0.7 kg |
| Compliance | EN 61010-1 (2010), 2006/95/EC (Low Voltage Directive), 2004/108/EC (EMC Directive), ISO 9001 certified manufacturing |
| Warranty | 2 years |
| Brand | MN |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PF-12 |
| Instrument Type | Portable / Handheld Photometer |
| Detection Targets | Heavy Metals (e.g., Cr, Cu, Ni, Pb, Zn, Cd, Fe, Mn) and Organic Parameters (e.g., COD, NO₃⁻, NO₂⁻, NH₄⁺, PO₄³⁻, Cl₂, TOC proxies) |
| Wavelength Range | 340–860 nm (7 fixed filters: 345, 436, 470, 540, 585, 620, 690 nm + 1 open slot) |
| Wavelength Accuracy | ±2 nm |
| Bandwidth | 10–12 nm |
| Light Source | Tungsten Halogen Lamp |
| Detector | Silicon Photodiode |
| Photometric Range | ±3 E (Absorbance) |
| Photometric Accuracy | ±1% of reading |
| Long-term Stability | <0.002 E/h |
| Sample Cell | 16 mm round cuvettes |
| Data Storage | 200 GLP-compliant records with timestamp, sample ID, location, dilution factor |
| Display | Backlit LCD (64 × 128 px) |
| Interface | USB 2.0 |
| Power Supply | USB bus power, AA alkaline or rechargeable batteries (≥2000 measurements per charge), 12 V automotive adapter |
| Enclosure Rating | IP67 |
| Dimensions | 215 × 100 × 65 mm |
| Weight | 0.7 kg |
| Operating Environment | 0–50 °C, ≤90% RH non-condensing |
| Compliance | EN 61010-1 (2006/95/EC Low Voltage Directive), EN 61326-1 (2004/108/EC EMC Directive), ISO 9001 certified manufacturing |
| Warranty | 2 years |
| Brand | MN |
|---|---|
| Origin | Germany |
| Model | 921 Series |
| Format | 100 strips/box, 6 × 85 mm |
| pH Range Options | 0.0–14.0 (multiple calibrated ranges) |
| Increment | 0.2–1.0 pH units (range-dependent) |
| Strip Construction | Chemically immobilized indicator dyes on cellulose fiber matrix |
| Compliance | Designed for ISO 9001-manufactured quality control |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MS900 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurable Parameters | Moisture Content (ppm), Dew Point Temperature |
| Measurement Principle | Chilled Mirror Hygrometry (with high-stability imported sensor) |
| Dew Point Range | –100 °C to +20 °C (–80 °C to –10 °C calibrated |
| Accuracy | ±2 °C (–80 °C to –40 °C), ±5 °C (–40 °C to –10 °C) |
| Sample Flow Rate | 2–3 L/min (recommended: 2 L/min) |
| Response Time (t₉₀) | 10 s (–80 °C to –10 °C), 15 min (–100 °C to –80 °C) |
| Operating Pressure | 0–1 MPa |
| Ambient Operating Conditions | –30 °C to +70 °C, 0–100 % RH |
| Power Supply | DC 24 V (rechargeable Li-ion battery, >8 h runtime) |
| Internal Tubing | 1/8″ stainless steel |
| Fitting | 1/8″ Swagelok compression |
| Dimensions | 335 × 266 × 175 mm |
| Weight | ~3 kg |
| Recommended Calibration Interval | 24 months |
| Compliance | Designed for ISO 8573-3, ASTM D2013, and IEC 60076-15 (for insulating gas moisture monitoring) |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Model | Microtox® CTM |
| Instrument Type | Online Continuous Monitoring System |
| Biological Sensor | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature | 5–30 °C |
| Photonic Detection Range | 1–120,000,000 photon counts per assay |
| Assay Duration | 5 minutes |
| Sample Flow Rate | 100–200 mL/min |
| Power Supply | 100–240 V AC, 50–60 Hz, 480 W |
| Display | 180 mm color touchscreen |
| Data Interfaces | Ethernet, USB, 4–20 mA output, relay alarm, optional GPRS/Wi-Fi |
| Certifications | CE, RoHS, WEEE |
| Enclosure Material | Anodized aluminum |
| Dimensions (Main Unit) | 1250 × 750 × 365 mm (H×W×D) |
| Weight | ~70 kg |
| Maintenance Interval | Monthly (~2 hours) |
| Reagent Format | Lyophilized, vacuum-sealed vials |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Microtox® FX Plus |
| Instrument Type | Portable |
| Biological Agent | *Vibrio fischeri* (NRRL B-11177) |
| Operating Temperature | 0°C – 40°C |
| Reagent Storage/Use Temperature | 10°C – 28°C |
| Repeatability | <20% CV |
| Photon Counting Range | 1 – 120 million counts |
| Assay Duration | 1 – 30 minutes (user-definable) |
| Compliance | ISO 11348-3, CE, ISO 13485 |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Microtox® FX |
| Instrument Type | Portable |
| Biological Agent | Aliivibrio fischeri (bioluminescent bacteria) |
| Operating Temperature | 0°C – 40°C |
| Reagent Storage/Use Temperature | 10°C – 28°C |
| Repeatability | CV < 20% in Q-Tox and B-Tox modes |
| Photon Counting Range | 1 – ~60,000,000 counts |
| Assay Duration | 1–60 minutes |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Model | Microtox® LX |
| Instrument Type | Laboratory-Based |
| Test Organism | Aliivibrio fischeri (bioluminescent marine bacteria) |
| Operating Temperature | 15 °C – 30 °C |
| Reagent Storage & Handling Temperature | 10 °C – 28 °C |
| Temperature Control Precision | ±0.5 °C (sample & read chambers), ±1.0 °C (reagent chamber) |
| Detection Time | 5 min (acute assay) |
| Reproducibility (CV) | ≤15% |
| Dimensions | 45.7 cm × 25.4 cm × 43.2 cm |
| Weight | 9 kg |
| Display | 7" capacitive touchscreen |
| OS | Microsoft Windows 10 (pre-installed Microtox LX software) |
| Connectivity | USB 2.0 ×3, Wi-Fi 802.11ac, Bluetooth 4.2 |
| Certifications | CE, IEC 61010-1:2010, IEC 61010-2-010:2014, IEC 61326-1:2013, FCC Part 15 Subpart B |
| Power Input | 100–240 V AC, 50/60 Hz, 200 W |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Model | OVA 7100 / OVA 7100Dualcell |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Up to 23 heavy metals (e.g., As, Cd, Cr, Cu, Hg, Ni, Pb, Se, Tl, Zn) |
| Detection Range | 0.5–5 µg/L |
| Accuracy/Precision | ±5–10% RSD |
| Analysis Frequency | Continuous real-time monitoring |
| Sample Compatibility | Raw water, wastewater, groundwater, surface water, drinking water, industrial effluent |
| Pre-treatment Options | Acid digestion, UV digestion, filtration |
| Electrode Type | Solid-state mercury-free working electrode |
| Compliance | Designed for ASTM D3559, ISO 8692, USP <232>/<233>, and GLP/GMP-aligned data integrity requirements |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Model | PDV 6000ultra |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | Up to 24 elements (e.g., Pb, Cd, Cu, Zn, As, Hg, Ni, Cr, Mn) |
| Analysis Time | ≤5 minutes per sample |
| Accuracy/Precision | ±5–10% RSD |
| Resolution | 1 ppb (µg/L) |
| Detection Limit | 0.1 µg/L for most target metals |
| Power Supply | 110–240 V AC adapter, 8–12 V DC input, or 4× AA batteries |
| Dimensions (main unit) | 360 × 270 × 155 mm (L×W×D) |
| Display | Integrated LCD |
| CE Certified | Yes |
| Electrode Options | Solid-state gold or glassy carbon working electrodes (mercury-free) |
| Compatible Software | VAS Desktop Software (Windows), embedded firmware, and Android tablet app (VAS Mobile) |
| Compliance | Designed for field deployment in accordance with ISO 17294-2, ASTM D3559, EPA Method 7000B, and GLP-aligned data integrity practices |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | UV-140 |
| Measurement Principle | Single-Wavelength UV Absorption (254 nm or 280 nm) |
| Sensor Material | 1.4404 (316L Stainless Steel) |
| Window Material | Sapphire |
| Protection Rating | IP65 / NEMA 4X |
| Process Connections | DIN, ANSI, SMS, NPT, APV, TH |
| Pipe Size Range | DN25–DN125 (½″–5″) |
| Max. Process Pressure | 16 bar (PN16) / 150 psi (ANSI Class 150) |
| Max. Process Temperature | 90°C continuous, 140°C short-term |
| Cable Length | Up to 100 m |
| Detection System | Dual-Diode Photometric (Reference + Measurement at 254 nm or 280 nm) |
| Measurement Range | 0–2 AU (Absorbance Units) |
| Accuracy | ±2% of reading |
| Reproducibility | ±1% |
| Calibration Interval | 12 months |
| Optional Features | CIP-compatible cleaning jet probe, air purge (4 mm), Ex-zone I/II certification available |
| Compatible Transmitter | Messenger Series |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AS3 |
| Pricing | Available Upon Request |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek1 |
| Type | Online Analyzer |
| Application | Real-time turbidity and total suspended solids (TSS) measurement in liquid process streams |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MP523-03 |
| Price | USD 920 (FOB Shanghai) |
| Instrument Type | Multi-Ion Meter |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.002 pH |
| pH Temp. Compensation | 0–100 °C |
| pCa Range (Meter) | 0.00–9.00 pCa |
| pCa Range (with Electrode) | 1.00–7.00 pCa |
| pCa Accuracy | ±0.01 pCa |
| pCa Temp. Compensation | 0–50 °C |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | −10 to 110 °C |
| Temp. Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MP523-04 |
| Price | USD 920 (FOB Shanghai) |
| Instrument Type | Fluoride-Specific Ion Meter |
| pH Range | −2.000–19.999 |
| pH Accuracy | ±0.002 pH |
| Fluoride pF Range (Meter) | 0.00–9.00 pF |
| Fluoride pF Range (with Electrode Pair) | 1.00–7.00 pF |
| Fluoride Accuracy | ±0.01 pF |
| Temperature Compensation | 0–50 °C (for F⁻) |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS |
| Temp. Range | −10–110 °C |
| Temp. Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| GLP Compliance | Yes |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MSS-2 |
| Instrument Type | Portable |
| Measurement Range | 0–30,000 mg/L (standard), 0–1,500 mg/L (low-range option) |
| Accuracy | ±3% of reading or ±20 mg/L, whichever is greater |
| Resolution | 1 mg/L (<1,000 mg/L), 10 mg/L (1,000–9,999 mg/L), 100 mg/L (≥10,000 mg/L) |
| Repeatability | ±0.5% |
| Drift | <1% per year |
| Operating Temperature (Sensor) | 0–65°C |
| Environmental Operating Range | −20 to +70°C |
| Humidity | 0–100% RH |
| IP Rating | IP66 |
| Max Pressure | 100 PSI |
| Sensor Cable Length | 6.0 m |
| Display | Backlit graphical LCD with UV-resistant housing and adjustable contrast |
| Data Storage | 50 internal records with non-volatile memory backup |
| Output Interface | RS-232 serial |
| Power | Rechargeable battery pack |
| Real-Time Clock | Integrated with date/time stamping |
| Diagnostic Capability | Automated self-test and sensor health monitoring |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MSS-2 |
| Instrument Type | Portable |
| Measurement Principle | Infrared Absorption Photometry |
| Range | 0–30,000 mg/L (standard), 0–1,500 mg/L (low-range option) |
| Accuracy | ±3% of reading or ±20 mg/L (whichever is greater) |
| Resolution | 1 mg/L (<1,000 mg/L), 10 mg/L (1,000–9,999 mg/L), 100 mg/L (≥10,000 mg/L) |
| Repeatability | ±0.5% |
| Drift | <1% per year |
| Operating Temperature (Sensor) | 0–65°C |
| Ambient Temperature | −20–70°C |
| Humidity | 0–100% RH |
| IP Rating | IP66 |
| Pressure Rating | 100 PSI |
| Sensor Cable Length | 6.0 m |
| Display | Backlit graphical LCD with adjustable contrast |
| Data Storage | 50 internal records |
| Output Interface | RS-232 (optional) |
| Power | Rechargeable battery |
| Weight | ~1.8 kg |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MTA 5 |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Online Multi-Parameter Water Quality Analyzer |
| Measured Matrices | Surface Water, Drinking Water, Municipal Wastewater, Industrial Effluent, Groundwater, Seawater |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MTA300 |
| Price Range | USD 27,000–68,000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Water Temperature, Dissolved Oxygen (DO), Electrical Conductivity / Salinity / Total Dissolved Solids (TDS), Oxidation-Reduction Potential (ORP), Depth |
| Brand | Myratek |
|---|---|
| Origin | USA |
| Model | Portable SS Sentry M-2 |
| Instrument Type | Portable |
| Measurement Range | 0–30,000 mg/L (or 0–1,500 mg/L selectable) |
| Accuracy | ±3% of reading or ±20 mg/L, whichever is greater |
| Sensitivity | 1 mg/L (≤1,000 mg/L), 10 mg/L (1,001–9,999 mg/L), 100 mg/L (≥10,000 mg/L) |
| Repeatability | ±0.5% |
| Drift | <1% per year |
| Operating Temperature | 0–65°C |
| Probe Diagnostic | Automatic self-diagnostic |
| Output | RS-232 serial interface |
| Data Storage | 50 records with timestamp |
| Display | UV-resistant graphical LCD with adjustable backlight contrast |
| Sensor Cable Length | 6.0 m |
| Ambient Operating Conditions | –20 to +70°C, 0–100% RH |
| Enclosure Rating | IP66 |
| Housing Materials | Epoxy, polyurethane, PVC |
| Maximum Pressure Rating | 100 PSI |
| Shipping Weight | ~1.8 kg |
| Brand | MyronL |
|---|---|
| Origin | USA |
| Model | Ultrameter III 9P |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Conductivity Range | 0–9999 µS/cm & 10–200 mS/cm |
| TDS Accuracy | ±1% |
| Resistivity Range | 10 kΩ·cm – 30 MΩ·cm |
| pH Range | 0–14, ±0.01 |
| ORP Range | ±999 mV, ±1 mV |
| Free Chlorine | 0.00–10.00 ppm (pH 5–9), ±2.5% |
| Hardness | 0–1710 ppm (CaCO₃) or 1–100 grains/gal |
| Alkalinity | 10–800 ppm (as CaCO₃) |
| LSI Range | −10 to +10 |
| Temperature | 0–71 °C (32–160 °F), ±0.1 °C |
| Data Storage | Up to 100 test records with timestamp |
| Wireless Connectivity | via bluDock™ accessory |
| Brand | NeuronBC |
|---|---|
| Model | Carbon TA5.0 |
| Origin | Beijing, China |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (Static UV Oxidation) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±5% of reading |
| Detection Limit | 1 ppb (as C) |
| Resolution | 0.1 ppb (display), 1 ppb (reporting) |
| Repeatability | ±5% RSD |
| Conductivity Detection Range | 0.055–6.000 µS/cm |
| Sample Temperature Range | 0–100 °C |
| Ambient Operating Temperature | 5–65 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Power Supply | 220 V ±10%, 50 Hz ±10% |
| Response Time | ≤5 min (t₉₀) |
| Drift | ±5% FS/24 h |
| Detector Unit Rated Power | 50 W per unit |
| Communication Interface | RS-485 (up to 48 nodes) |
| Display | 10-inch capacitive touchscreen HMI |
| Data Terminal | TOC-D500 central controller supporting up to 8 distributed TA5.0 sensor units |
| Sample Tubing | PTFE, 1 mm ID, fitted with Swagelok® 50-series quick-connect fittings |
| Data Storage | Internal SD card (≥8 GB), 10-year historical archive (1-min intervals) |
| Output | Real-time analog 4–20 mA, Modbus RTU/TCP, optional thermal printer integration |
| Brand | NeuronBC |
|---|---|
| Model | JWG-7A |
| Measurement Principle | Laser Light Obscuration (Single-Particle Counting) |
| Detection Range | 1–500 µm |
| Channel Configurations | ≥5 µm, ≥10 µm, ≥25 µm, 15–25 µm, 25–50 µm, 51–100 µm, >100 µm (user-definable up to 16 channels) |
| Minimum Sample Volume | ≥0.1 mL |
| Particle Count Capacity | 0–9,999,999 particles per sample |
| Concentration Range | 0–10,000 particles/mL |
| RSD | ≤2% (for NIST-traceable standard latex particles ≥1000 particles/mL) |
| Accuracy | ±5% of reference value |
| Channel Resolution | ≥95% (≥10 µm channel) |
| Sampling Time | <10 s for 5 mL |
| Stirring Speed | 0–2000 rpm (adjustable glass propeller stirrer) |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤90 W |
| Dimensions | 390 × 350 × 470 mm |
| Compliance | GB 8368–2005, GB 8368–2018, GB 8368–1998 (Medical Devices & Pharmaceutical Packaging Materials), ISO 21501-4, USP <788> and <789> (with method validation), FDA 21 CFR Part 11-ready (JWG-7DS variant) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Benchtop Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation (254 nm) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% RSD |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Sample Temperature Range | 1–99 °C |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier role-based authentication |
| Data Export | USB flash drive support |
| Data Storage Capacity | >5000 test records |
| Display | Color capacitive touchscreen |
| Compliance | Meets Chinese Pharmacopoeia 2020 Edition (ChP) General Chapter <0682>, FDA 21 CFR Part 11 (electronic records & signatures), and GLP/GMP-aligned validation protocols (IQ/OQ/PQ support available) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photocatalytic Oxidation (with TiO₂-coated quartz tube) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Sample Temperature Range | 1–99 °C |
| Data Storage | >5000 records |
| Audit Trail | 16-event log with timestamped traceability |
| User Access Control | 4-tier role-based authentication compliant with FDA 21 CFR Part 11 |
| Display | Color touchscreen interface |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Sample Temperature Range | 1–99 °C |
| Data Logging | 5000+ records |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier password authentication compliant with FDA 21 CFR Part 11 |
| Display | Color touchscreen |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 OL Offline |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 1–1000 ppb C |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb C |
| Resolution | 1 ppb C (full range) |
| Repeatability | ±3% RSD |
| Compliance | Designed to meet Chinese Pharmacopoeia 2020 Edition (ChP), USP <643>, and EP 2.2.44 requirements for offline water quality testing |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 Offline |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation (TiO₂-coated Quartz Tube) |
| Measurement Range | 1–1000 ppb (0.001–1.0 mg/L) |
| Accuracy | ±3% of reading |
| Resolution | 1 ppb (0.001 mg/L) |
| Detection Limit | 1 ppb (0.001 mg/L) |
| Repeatability | ≤3% RSD |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Sample Temp. Range | 1–99 °C |
| Data Storage | >5000 records |
| Audit Trail | 16-event log with timestamped traceability |
| User Access Control | 4-tier role-based authentication compliant with FDA 21 CFR Part 11 |
| Display | Color TFT touchscreen |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0/TOC |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 ppb (as C) |
| Resolution | 1 ppb (as C) |
| Repeatability | ±3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | ≤5 min per sample |
| Power Supply | 220 V AC |
| Display | Color TFT Touchscreen |
| Data Storage | Internal memory for ≥10,000 test records |
| Compliance | Meets Chinese Pharmacopoeia 2020 Edition (ChP) Chapter 0682 requirements for purified water and WFI |