| Brand | ShengAohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SRB300 (V9) |
| Digestion Method | Rapid Digestion |
| Heating Modules | Dual Independent Heating Blocks |
| Batch Capacity | 30 samples |
| Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±1 °C |
| Digestion Vessel Capacity | 17 mL |
| Timer Accuracy | ±0.1 s at 10 min |
| [Brand | Shentai (SENTE) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ST106BW |
| Digestion Method | Reflux Digestion |
| Heating Module | Dual Independent Heating Blocks |
| Batch Capacity | 15 Samples |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±1 °C |
| Digestion Vessel Capacity | 220 mL |
| Timer Accuracy | ±1 min] |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M926, M926S |
| Instrument Type | Benchtop Chloride Analyzer |
| Detection Principle | Coulometric Titration (Silver Nitrate Electrolytic Generation) |
| Sample Volume | M926: 500 µL |
| M926S | 20 µL |
| Measurement Range | M926: 10–999 mg/L Cl⁻ (equivalent to 2–165 mg% NaCl) |
| M926S | 10–299 mmol/L Cl⁻ |
| Detection Limit | 10 mg/L Cl⁻ (M926) |
| Response Time | ≤36 s (typical endpoint detection) |
| Accuracy | M926: ±3 mg/L or <1% RSD at 0.1% Cl⁻ |
| M926S | ±2% at 100 mmol/L Cl⁻ |
| Linearity | ≤1% deviation across full range |
| Repeatability (CV, n=20) | <1.5% at mid-range concentration |
| Temperature Control | Integrated ambient-temperature-stabilized cell compartment |
| Compliance | Designed for GLP/GMP environments |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 926, 926S |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Coulometric Titration (Silver Nitrate Generation) |
| Measured Parameters | Chloride ion (Cl⁻), Salt (% w/v, mg/L, mmol/L) |
| Range | 10–999 mg/L Cl⁻ |
| Accuracy | SD <1% @ 0.1% Cl⁻ Std Solution |
| Repeatability | <1.5% RSD @ 200 mg/L Cl⁻ and @ 100 mmol/L Cl⁻ |
| Resolution | 0.01 ppm Cl⁻ |
| Detection Limit | 200 mg/L Cl⁻ |
| Sample Volume | 500 µL (926), 20 µL (926S) |
| Analysis Time | ≤35 sec (Cl⁻), ≤72 sec (full titration cycle) |
| Calibration Units | mg/L, mmol/L, % Salt |
| Compliance | ASTM D4327, ISO 9297, USP <731>, FDA 21 CFR Part 11 (with optional audit trail software) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | COD-4200 |
| Instrument Type | Online Analyzer |
| Measurement Principle | High-Temperature Potassium Dichromate Digestion with Photometric Detection |
| Standard Range | 30–4000 mg/L COD |
| Accuracy | ±10% at ≥100 mg/L |
| Repeatability | ≤±5% |
| Zero Drift | ±5 mg/L |
| Span Drift | ≤±5% |
| Resolution | <1 mg/L |
| Minimum Measurement Cycle | 20 minutes |
| Calibration Modes | Manual and Automatic |
| Communication Interfaces | RS-232, 4–20 mA (bidirectional) |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Power Consumption | ~100 VA |
| Dimensions | 500 mm × 420 mm × 1550 mm |
| Weight | ~90 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | COD-4200 |
| Price Range | USD 21,000 – 28,000 (est.) |
| Instrument Type | Online Analyzer |
| Measurement Principle | High-Temperature Acidic Potassium Dichromate Digestion with Photometric Detection |
| Accuracy | ±10% for concentrations ≥100 mg/L |
| Minimum Measurement Cycle | 20 minutes |
| Measuring Range | 30–4000 mg/L COD (extended range available upon consultation) |
| Repeatability | ≤±5% |
| Zero Drift | ±5 mg/L |
| Span Drift | ≤±5% |
| Resolution | <1 mg/L |
| Output Signals | RS-232, 4–20 mA (bidirectional communication & remote control supported) |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Power Consumption | ~100 VA |
| Dimensions | 500 × 420 × 1550 mm (W × D × H) |
| Weight | ~90 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | HMA-4200 Series |
| Measurement Principles | Colorimetric Spectrophotometry per ISO 11969 / GB/T 7467–1987 (for Cr(VI)), ISO 11045 / GB/T 7475–1987 (for Total Cr, Cu, Ni) |
| Detection Range | 0–2 mg/L (Cr(VI), Total Cr), 0–3.5 mg/L (Total Cu), 0–10 mg/L (Total Ni) |
| Accuracy | ≤±5% FS |
| Repeatability | ≤±5% RSD |
| Linearity Error | ≤±5% FS |
| Span Drift | ≤±5% over 24 h |
| Zero Drift | ≤±3% (Cr(VI), Total Ni), ≤±5% (Total Cu) |
| Minimum Measurement Cycle | 20 min (Cr(VI)), 50 min (Total Cr, Cu, Ni) |
| Calibration Mode | Manual or Automatic (with standard solution dispensing module) |
| Output Interface | RS-232 serial port and isolated 4–20 mA analog output |
| MTBF | ≥1440 h |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Dimensions (H×W×D) | 1550 × 500 × 420 mm |
| Enclosure Rating | IP54 (indoor installation) |
| Compliance | Designed to support ISO/IEC 17025-compliant QA/QC workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TNP-4200 |
| Measurement Parameters | Total Nitrogen (TN), Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Alkaline Potassium Persulfate UV Oxidation – UV Absorbance (TN) |
| Detection Range | TN: 0–2 / 5 / 10 / 20 / 50 / 100 / 200 mg N/L |
| TP | 0–0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 mg P/L |
| Cycle Time | 60 min (simultaneous TN & TP) |
| Power Consumption | ≤300 VA (AC 100–240 V, 50/60 Hz) |
| Operating Environment | Indoor use only |
| Sample Pretreatment | High-speed rotary homogenizer with auto backwash filter |
| Auto-Cleaning | Scheduled distilled water flush of fluidic pathways |
| Auto-Calibration | Dual-point (zero & span) using standard solutions |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TOC-4200 |
| Instrument Type | Online TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion at 680 °C |
| Detection Principle | NDIR (Non-Dispersive Infrared) CO₂ Detection |
| Measurement Range | 0–1 ppm to 0–20,000 ppm (auto-ranging) |
| Cycle Time | Minimum 4 minutes per analysis |
| Carrier Gas | High-Purity Nitrogen (≥99.99%, 250–300 kPa) |
| Power Supply | 90–260 V AC, 50/60 Hz, 6 A |
| Power Consumption | 200 W (at operating temperature) |
| Operating Environment | 0–40 °C, ≤90% RH, Indoor Installation Only |
| Calibration | Auto-zero & span calibration |
| Sample Handling | Integrated high-speed rotary homogenizer |
| Internal Cleaning | Scheduled distilled-water flush of fluidic pathways |
| Interface | Full-color capacitive touchscreen |
| Communication | MODBUS RTU over RS-232/RS-485, 4–20 mA analog output, digital I/O |
| Brand | Shimadzu |
|---|---|
| Model | TOC-4200 |
| Measurement Principle | Catalytic Combustion Oxidation + NDIR CO₂ Detection |
| Oxidation Temperature | 680 °C |
| Measurement Range | 0–1 ppm to 0–20,000 ppm (selectable) |
| Accuracy | ±1.0% of reading |
| Detection Limit | 0.01 ppm |
| Resolution | 0.001 ppb |
| Repeatability | ≤1% RSD |
| Analysis Cycle | Minimum 4 minutes |
| Carrier Gas | High-purity nitrogen (≥99.99%, 250–300 kPa) |
| Power Supply | 90–260 V AC, 50/60 Hz, 6 A |
| Power Consumption | 200 W (at operating temperature) |
| Operating Environment | 0–40 °C, ≤90% RH, indoor installation only |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | TOC-5000A |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±4% |
| Detection Limit | 0.005 ppm C |
| Resolution | 0.001 ppb C |
| Repeatability | ≤3% RSD |
| Sample Types | Liquid (aqueous), Solid (soil, sludge, sediment, wipe samples), Suspended Solids-Rich Water |
| Compliance | Designed for GLP/GMP environments with audit-ready operation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TOC-L |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion Oxidation (680 °C) |
| Measurement Range | 4 μg/L to 30,000 mg/L |
| Detection Principle | CO₂ quantification via Non-Dispersive Infrared (NDIR) detection after catalytic combustion |
| Power Savings | Up to 36% vs. prior generation (8 h/day, 5 days/week) |
| Footprint Reduction | Width reduced from ~440 mm to 340 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | TOC-L |
| Price Range | USD 13,500 – 27,000 (FOB Japan) |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | High-Temperature Catalytic Combustion Oxidation |
| Oxidation Temperature | 680 °C |
| Measurement Range | 4 µg/L to 30,000 mg/L as C |
| Detection Method | NDIR (Non-Dispersive Infrared) |
| Sample Types | Liquid aqueous matrices including ultrapure water, wastewater, seawater, and industrial process water |
| Compliance | Designed to meet ASTM D7573, ISO 8245, USP <643>, and EP 2.2.44 requirements |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TOC-L |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion at 680°C |
| Measurement Range | 4 µg/L to 30,000 mg/L |
| Accuracy | ±10% of reading |
| Resolution | 0.004 mg/L |
| Detection Limit | 0.05 mg/L |
| Repeatability | ±3% RSD |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | TOC-V |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion at 680 °C |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±4% |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.005 ppm C |
| Repeatability | ≤3% RSD |
| Detection Principle | Catalytic Combustion Oxidation + NDIR Detection |
| Sample Introduction | Programmable 8-Channel Syringe Pump |
| IC Removal | Automated Acidification + Sparging (NPOC Mode) |
| Blank Water Generation | Onboard Deionized Water Purification System |
| Compliance | Designed to support ASTM D7573, ISO 8245, USP <643>, and EPA Method 415.3 workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | TP-4110 |
| Measurement Parameter | Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Persulfate UV Oxidation–Molybdenum Blue Spectrophotometry |
| Detection Range | 0–0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 mg P/L |
| Measurement Cycle | 60 min |
| Sample Pretreatment | High-speed rotary homogenizer + automatic backwash filtration using tap water |
| Automatic Cleaning | Distilled water flush at user-defined intervals |
| Power Supply | 220 V ±10 V, 50/60 Hz, ≤300 VA |
| Operating Temperature | 1–40 °C |
| Relative Humidity | ≤90 % RH (non-condensing) |
| Installation | Indoor only |
| Compliance | Designed for continuous compliance monitoring per China’s HJ 353–2019, HJ 354–2019, and HJ 355–2019 standards for online water quality analyzers |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | UVM-4020 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Weighted Multi-Wavelength Ultraviolet Absorption Spectrophotometry (243 nm, 254 nm, 265 nm, 275 nm, 290 nm) |
| Calibration | Automatic zero/span calibration with standard solutions (optional) |
| Measurement Ranges | 0–400 SAC, 0–200 SAC, 0–80 SAC |
| Cycle Time | 1 min (minimum), adjustable from 10 to 720 min |
| Output Parameters | COD, BOD, TOC, SAC |
| Preloaded Conversion Formulas | 30 built-in empirical equations |
| Auto-Cleaning Interval | User-configurable timer-based internal tubing flush |
| Power Supply | 220 V ±10 V, 50/60 Hz, ~100 VA |
| Operating Environment | 5–40 °C, ≤90% RH (non-condensing, non-freezing) |
| Sample Flow Rate | 1–2 L/min |
| Max. Sample Pressure | ≤50 kPa |
| Installation | Indoor only |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Distributor Status | Authorized Distributor |
| Model | UVM-4020 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Weighted Multi-Wavelength Ultraviolet Absorption Spectrophotometry (UV-Vis) |
| Wavelengths | 243 nm, 254 nm, 265 nm, 275 nm, and 290 nm (simultaneous acquisition with spectral weighting) |
| Measurement Ranges | 0–400 SAC, 0–200 SAC, 0–80 SAC |
| Cycle Time | Minimum 1 minute |
| Power Supply | 220 V ±10 V, 50/60 Hz, ~100 VA |
| Operating Environment | 5–40 °C, ≤90% RH (non-condensing, non-freezing) |
| Sample Flow Rate | 1–2 L/min |
| Sample Pressure | ≤50 kPa |
| Calibration | Automated zero/span calibration (optional reagent-free standard solutions) |
| Conversion Functions | Simultaneous real-time calculation of COD, BOD, TOC, and SAC using 30 built-in empirical correlation models |
| Cleaning | Scheduled internal tubing purge via user-defined intervals |
| Installation | Indoor wall- or rack-mounted configuration |
| Compliance | Designed for continuous operation under ISO 5667-3, ASTM D5540, and EPA Method 415.3-aligned monitoring workflows |
| Brand | SHINE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | SH-Cr-100 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Detection Principle | Post-Column Derivatization Coupled with Ion Chromatography–UV/Vis Spectrophotometry |
| Target Analyte | Chromium(VI) |
| Analysis Time | ≤3 min per sample |
| Accuracy/Precision | ±3% RSD |
| Detection Resolution | 0.01 ppb (as Cr(VI)) |
| Detection Range | 0.01 ppb – 10 ppm (as Cr(VI)) |
| Optical Detection Wavelength | 540 nm |
| Derivatization Reagent | 1,5-Diphenylcarbazide (DPC) in acidic medium |
| Compliance | Designed for ASTM D5281, ISO 17294-2, and EPA Method 218.7 workflows |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | SIA-3000 Series |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Nitrogen (TN), Total Phosphorus (TP), Ammonia-Nitrogen (NH₃-N), Permanganate Index (CODₘₙ), Chemical Oxygen Demand (COD) |
| Regulatory Compliance | HJ 636, GB 11893, HJ 536, GB 11892, HJ 828 |
| Sample Matrix | Surface Water, Drinking Water, Municipal Wastewater, Industrial Process Water, Effluent from Pollution Sources |
| Measurement Modes | Continuous, Cyclic, Manual, Remote-Triggered |
| Calibration & Maintenance | Automated Cyclic Cleaning and Standard Calibration |
| Flow Architecture | Sequential Injection Analysis (SIA) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 500RL |
| Detection Range | 0.03–2,500 ppb as C |
| Accuracy | ±5% |
| Precision | ≤0.03 ppb (for <3 ppb) or ≤1% RSD (for ≥3 ppb) |
| Conductivity Measurement Range | 0.01–35 µS/cm |
| Conductivity Accuracy | ±0.005 µS/cm (≤0.25 µS/cm) or ±2% (>0.25 µS/cm) |
| Conductivity Precision | <0.25% RSD |
| Max Acceptable Sample Conductivity | 25 µS/cm at 25°C (neutral pH) |
| Ozone Tolerance | 200 ppb |
| Operating Temperature Range | 1–95°C (steam-tolerant for short durations) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | Sievers 900 |
| Detection Range | 0.03 ppb to 50 ppm |
| Accuracy | ±2% |
| Precision | <1% RSD |
| Oxidation Method | UV/Persulfate |
| Detection Method | Membrane Conductivity |
| Sample Pressure | up to 250 psi |
| Flow Rate | 30–300 mL/min |
| Sample Temperature | 1–95 °C |
| Analysis Time | 4 min (standard), 4 s (rapid module) |
| IP Rating | IP65 |
| Compliance | US EPA Method 5310C, US EPA 415.3, ASTM D7573 |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported |
| Model | Sievers Boron |
| Pricing | Upon Request |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Boron Ultra |
| Pricing | Available Upon Request |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CheckPoint |
| Instrument Type | Portable & Online TOC Analyzer |
| Measurement Principle | Direct Conductivity (DC) Detection |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.05–1000 ppb C (CheckPointe) |
| Accuracy | ±5% (at 500 ppb C sucrose) |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.05 ppb C |
| Precision (Online Mode) | RSD <1% or 0.05 ppb (whichever is greater, CheckPointe) |
| Data Output Interval | Adjustable from 15 seconds to 8 hours |
| Sample Temperature Range | 10–90 °C (CheckPoint Pharma) |
| Ambient Operating Temperature | 10–55 °C (Pharma) |
| Pressure Rating | 103–690 kPa (15–100 psig) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 60 W |
| Certifications | CE, ETL listed |
| Regulatory Compliance | FDA 21 CFR Part 11 ready (via USB printer support), GLP/GMP-aligned IQ/OQ/PQ protocols |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | CheckPoint |
| Instrument Type | Online TOC Analyzer |
| Measurement Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis |
| Measurement Range | 0.21–1000 ppb C |
| Accuracy | ±5% |
| Resolution | 0.01 ppb C |
| Detection Limit | 0.21 ppb C |
| Repeatability | RSD < 1% |
| Analysis Time (Online Mode) | 15 s – 8 h (configurable) |
| Analysis Time (Grab Sample Mode) | 10 min |
| Calibration Interval | 6 months |
| Data Storage Capacity | 28,800 records |
| Connectivity | Ethernet, Modbus RTU/TCP |
| Compliance Support | IQ/OQ/PQ protocols available |
| Regulatory Context | Designed for compliance with USP <643>, EP 2.2.44, ASTM D5905, and FDA 21 CFR Part 11-ready data integrity architecture |
| Brand | Sievers/Veolia |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CheckPoint |
| Pricing | Available Upon Request |
| Detection Range | 0.05–1,000 ppb C |
| Precision | Greater of <1% RSD or 0.05 ppb (online, 20–40 °C) |
| Analysis Modes | Online continuous averaging, online timed sampling, offline grab sampling |
| Analysis Time | 15 s (online), 10 min (grab) |
| TOC Calibration Interval | 6 months |
| Conductivity Tolerance | Up to 1.4 µS/cm (0.7 MΩ·cm) CO₂-compensated conductivity |
| Conductivity Precision | ±0.5% RSD (20–40 °C) |
| Conductivity Accuracy | ±2.0% |
| Conductivity Calibration Interval | 6 months |
| Operating Pressure (Online) | 15–100 psi |
| Low-Pressure Sampling | Max. 0.70 m head above analyzer |
| Minimum Online Flow Rate | >60 mL/min |
| Power Supply | 100–240 V ±10%, 60 W, 50/60 Hz |
| Sample Temperature Range | 10–90 °C |
| Ambient Operating Temperature | 10–40 °C |
| Enclosure Rating | Indoor use only |
| I/O Options | Ethernet, 2 analog outputs, 2 alarm outputs, parallel inputs |
| Installation Category | Overvoltage Category II |
| Dimensions (H×W×D) | 25.4 × 30.48 × 15.24 cm (standard) |
| Weight | 2.9 kg (no battery), 3.58 kg (with battery), +0.6 kg (vial sampler) |
| Safety Certifications | CE, ETL Listed |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Sievers InnovOx ES Lab |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 50 ppb – 50,000 ppm TOC |
| Accuracy | ±3% of reading or ±0.25 ppm (whichever is greater), for 1–100 ppm NPOC/TOC |
| Resolution | 0.001 ppb |
| Detection Limit | 50 ppb NPOC |
| Repeatability | RSD ≤ 3% (>5 ppm NPOC or TOC) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Sievers InnovOx Lab |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 0.05 ppm – 50,000 ppm TOC |
| Accuracy | ±3% |
| Resolution | 0.05 ppm |
| Detection Limit | 0.05 ppm |
| Repeatability | RSD ≤ 1.5% |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Model | InnovOx Laboratory |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 0.05–50,000 ppm TOC |
| Accuracy | ±3% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.05 ppm |
| Repeatability | ±3% |
| Regulatory Compliance | US EPA Methods 415.1, 415.3, 9060A |