X-Ray Instruments
Filter
Showing 451–480 of 786 results
| Brand | Olympus |
|---|---|
| Origin | USA |
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model Series | Vanta Element |
| Application | Handheld / Portable |
| Industry Focus | Ferrous Metals |
| Elemental Range | Mg to U |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | ≤0.1% RSD (relative standard deviation) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta GX |
| Form Factor | Benchtop |
| Industry Application | Non-Ferrous Metals |
| Elemental Range | Mg (12) – U (92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | OLYMPUS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta GX PIN |
| Instrument Type | Benchtop |
| Instrument Configuration | Multi-Channel |
| X-ray Tube Power | 70 W, 18 VDC, 50–60 Hz |
| Elemental Range | Atomic Number 12 (Mg) to 92 (U) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta |
| Application | Handheld / Portable |
| Industry Type | General Purpose |
| Elemental Range | Mg to U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta RoHS Series |
| Application | Handheld / Portable |
| Industry-Specific Use | Electronics |
| Elemental Range | Mg–U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta Series |
| Application | Handheld/Portable |
| Industry-Specific Use | Soil & Environmental Monitoring |
| Elemental Range | Mg–U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanta Series Alloy Analyzer |
| Application | Handheld / Portable |
| Industry-Specific Type | Non-Ferrous Metals |
| Elemental Analysis Range | Mg to U |
| Quantitative Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | ±0.1% RSD |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | X-5000 |
| Application | Field-deployable portable analysis |
| Industry Focus | Energy & Petrochemicals |
| Elemental Range | Na (11) to U (92) |
| Quantification Range | 1 ppm – 100% |
| Energy Resolution | <150 eV (FWHM at Mn Kα) |
| Repeatability | ±0.1% RSD |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | X-5000a |
| Application | Field-portable soil and sediment analysis |
| Elemental Range | Na to U |
| Detection Range | 1 ppm to 100% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Detector Type | Silicon Drift Detector (SDD) |
| Compliance | EPA Method 6200, ISO/DIS 13196, TCLP, RCRA 8 Metals, ASTM D6729, OSHA/NIOSH/NIH/HUD guidelines |
| Certifications | ISO 9001, NATO AQAPI-110 |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | XRD-Terra |
| Instrument Type | Powder X-ray Diffractometer |
| Power Stability | < 0.0001 (unitless relative stability) |
| Dimensions | 485 × 392 × 192 mm |
| Weight | 14.5 kg (including integrated battery pack) |
| Sample Mass Requirement | ~15 mg |
| Measurement Time | ≤ 3 minutes per sample |
| Detector | 2D CCD-based area detector |
| Geometry | Transmission-mode XRD |
| Integrated Capability | Simultaneous XRD and XRF analysis |
| Cooling | Peltier electronic cooling |
| Environmental Rating | IP54-equivalent (dust- and splash-resistant), shock-damped chassis |
| Compliance | NASA Patent US7113265B2 |
| Software Interface | WiFi-enabled remote acquisition and real-time data streaming |
| Brand | GKINST |
|---|---|
| Model | GK-THMS350V |
| Max Temp | 350 °C |
| Min Temp | −195 °C |
| Max Heating Rate | 150 °C/min |
| Max Cooling Rate | 30 °C/min |
| Temp Resolution | < 0.05 °C |
| Temp Stability | < 0.05 °C |
| Control Algorithm | PID Dynamic Regulation |
| Sensor Type | PT100 Platinum Resistance Thermometer |
| Brand | Oxford Instruments |
|---|---|
| Origin | USA |
| Model | 5000 Series |
| Max Anode Current | 1.0 mA |
| Max Anode Voltage | 50 kV |
| Max Power | 50 W |
| Filament Nominal Voltage | 2.0 V @ 50 kV, 1 mA |
| Filament Max Current | 1.7 A |
| Stability (4 hr) | ±0.2% |
| Nominal Focal Spot Size | 110 µm |
| Anode Material Options | W, Mo, Rh (custom anodes available) |
| Beryllium Window Thickness Options | 75 µm, 125 µm, 250 µm |
| Approx. Weight | 1.816 kg (4 lbs) |
| Cooling Method | Compressed Air @ 150 CFM |
| Beam Divergence Angle | 25° |
| Brand | Oxford Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | UltraBright |
| Price Range | USD 0 – 9,999 |
| Max Anode Current | 1.0 mA |
| Max Anode Voltage | 50 kV |
| Max Power | 50 W |
| Filament Nominal Voltage | 2.0 V @ 50 kV, 1 mA |
| Filament Max Current | 1.7 A |
| Stability (after 4 hrs) | ±0.2% |
| Nominal Focal Spot Size | 110 µm |
| Anode Materials | W, Mo, Rh (custom options available) |
| Beryllium Window Thickness | 125 µm (optional: 75 µm or 250 µm) |
| Approx. Weight | 1.816 kg (4 lbs) |
| Cooling Method | Compressed Air @ 150 CFM |
| Beam Divergence Angle | 25° |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PeDX G5 |
| Application Form Factor | Handheld / Portable |
| Instrument Type | Conventional EDXRF |
| Industry Use | General-Purpose |
| Elemental Range | Al to U (Atomic Number 13–92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <136 eV at Mn Kα |
| Repeatability (RSD) | ≤0.1% for homogeneous alloy standards |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PeDX 980 / PeDX 980S / PeDX 980CS |
| Application | Handheld / Portable |
| Instrument Type | Conventional ED-XRF |
| Industry Use | General-Purpose |
| Elemental Range | Mg to U |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | < 136 eV (at Mn Kα) |
| Repeatability | ≤ 0.1% RSD (for repeated measurements under controlled conditions) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | XD-2 / XD-3 |
| Instrument Type | Powder X-ray Diffractometer |
| Price Range | USD 70,000 – 140,000 (FOB China) |
| Detector | Imported NaI Scintillation Counter |
| Goniometer Configuration | Vertical θ–θ geometry with hollow-axis design |
| X-ray Source Control | Fully digital, microprocessor-regulated high-voltage and tube current |
| Software | PDP Diffraction Data Processing Suite (Windows-based, multi-format export support) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | XD-6 Series |
| Price Range | USD 42,000 – 70,000 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | Portable350 |
| Price Range | USD 7,000–14,000 (FOB) |
| Form Factor | Handheld / Field-Deployable |
| Industry-Specific Use | Environmental & Industrial Compliance Monitoring |
| Elemental Range | Mg (Z=12) to U (Z=92) |
| Quantification Range | 1 ppm to 99.99 wt% |
| Energy Resolution | 149 ± 5 eV at Mn Kα |
| Repeatability | RSD ≤ 0.05% (for Fe in certified soil matrix, 60 s measurement) |
| Brand | Princeton Instruments |
|---|---|
| Sensor Type | Back-illuminated or front-illuminated deep-depletion CCD |
| Energy Range | 3–20 keV |
| Window Material | Vacuum-integrated beryllium (Be) |
| Cooling | Thermoelectric (TE) cooling to –70 °C |
| Readout Architecture | Dual-amplifier selectable for low-noise or high-dynamic-range mode |
| Software Support | LightField v8.x, PICAM SDK, LabVIEW® and MATLAB® integration |
| Compliance | ASTM E1316, ISO/IEC 17025-compatible operation, FDA 21 CFR Part 11-ready audit trail (via LightField) |
| Brand | BosinTech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | FD-25 |
| Pricing | Available Upon Request |
| Brand | Pulstec |
|---|---|
| Origin | Japan |
| Model | s-Laue/m-Laue |
| X-ray Source | Tungsten anode |
| Voltage/Current | 30 kV / 1.6 mA |
| Cooling | Air-cooled |
| Irradiation Spot Size | φ0.8 mm (standard collimator) |
| Sample-to-Detector Distance | 33 mm |
| Typical Exposure Time | 15 s |
| Sample Stage | 6-axis (Θ, translation, radial, X, Y, Z) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Max. Power Consumption | 150 W |
| Safety | Integrated door interlock |
| Dimensions (s-Laue) | 224 × 414 × 480 mm |
| Dimensions (m-Laue) | 800 × 600 × 600 mm |
| XY Translation Stage | Included on m-Laue only |
| Brand | Pulstec |
|---|---|
| Origin | Japan |
| Model | μ-X360J |
| X-ray Tube | 30 kV, 1.6 mA |
| Target Material | Standard Cr (optional V, Cu, Co, Mn) |
| Collimator | Ø1 mm (custom sizes available) |
| Detector | Full 2D area detector |
| Measurement Time | ~60 s per point |
| Power Supply | 130 W, 110–240 V, 50–60 Hz |
| Cooling | Air-cooled, no water chiller required |
| Portability | Battery-operated, weight ≈ 8.1 kg |
| Compliance | JSMS-SD-14-20 (Japan) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PCS-3A |
| Application | Handheld/Portable |
| Element Detection Range | C₅–Cₙ organic compounds |
| Quantification Range | 1–2000 (unitless relative scale) |
| Energy Resolution | 0.01 FU (Fluorescence Unit) |
| Repeatability | ≥99% |
| Detector Type | X-ray-excited ultraviolet fluorescence (XUVF) detector |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuanX |
| Configuration | Benchtop or Floor-Standing |
| Detector Options | Liquid-Nitrogen-Cooled or Electrically Cooled Si(Li) Detector |
| Elemental Range | Na (11) to U (92) |
| Detection Limit | Typically sub-ppm to 100% w/w |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | RapidXAFS |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Model | RapidXAFS 1M |
| Price Range | USD 420,000 – 700,000 |
| X-ray Source Power | 1.6 kW & 3.0 kW |
| Monochromatic X-ray Photon Flux | 1,000,000 photons/s/eV |
| Minimum Detectable Elemental Concentration | 1 wt% |
| Tunable X-ray Absorption Energy Range | 4.5 keV – 15 keV (extendable) |
| Brand | RapidXAFS |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RapidXAFS 2M |
| Price Range | USD 700,000 – 1,400,000 |
| X-ray Source Power | 1.6 kW & 3.0 kW |
| Monochromatic X-ray Photon Flux | > 2,000,000 photons/s/eV at 8 keV |
| Minimum Detectable Elemental Concentration | 0.5 wt% (on CN-supported matrix) |
| Tunable X-ray Absorption Energy Range | 4.5 keV – 20 keV |
| Brand | RapidXAFS (Anhui Absorption Spectrometer) |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic |
| Model | RapidXAFS In Situ Cell |
| Price Range | USD 280,000–420,000 |
| X-ray Source Power | ≤100 W |
| Minimum Detectable Elemental Concentration | 1 wt% |
| X-ray Absorption Energy Range | 2.5–5 keV |
| XAFS Spectrum Acquisition Speed | 1 spectrum/s |
| Brand | RapidXAFS |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RapidXAFS Emission Spectrometer |
| Price Range | USD 390,000 – 490,000 |
| X-ray Source Power | ≤100 W |
| Minimum Detectable Elemental Content | ≤1 wt% |
| Tunable X-ray Absorption Energy Range | 2.5–5 keV |
| Fluorescence Detection Energy Range | 5–15 keV |
| Detectable Edges | 3d transition metal K-edges, 5d transition metal L-edges, actinide L-edges |
| Energy Resolution | ≤1.5 eV @ Cu Kα |
| Detector Efficiency | ≥1×10¹¹ counts per photon |
| Spectral Reproducibility | Energy drift <50 meV across repeated scans |
| Ambient Control | Helium-purged measurement chamber |
| Monochromator | High-purity Si or Ge single-crystal analyzer |
| In Situ Capability | Modular reaction cells for high/low temperature, multiphase catalysis, electrocatalysis, and operando studies |
| Data Acquisition | Real-time XES spectral output during acquisition |
| Brand | Raykol |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JP500 |
| Application Form Factor | Handheld / Portable |
| Industry Use | General-Purpose |
| Elemental Range | Al to U |
| Quantification Range | 0.03 ppm – 100% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Relative Standard Deviation (RSD) | ≤0.08% for major elements |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Brand | Raykol |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JPX500 |
| Application Form Factor | Handheld/Portable |
| Industry Use | General-Purpose |
| Elemental Range | Al to U (40+ elements) |
| Quantification Range | 0.03 ppm – 100% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability (RSD) | ≤0.08% |
| Detector | High-Performance Silicon Drift Detector (SDD) |
