- All
- Favorite
- Popular
- Most rated
| Brand | ESCO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Esco LBC |
| Pricing | Available Upon Request |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Not specified |
| Pricing | Available upon request |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | WDCI Series |
| Pricing | Upon Request |
| Brand | ESCO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | LF |
| Pricing | Upon Request |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AERIS-BG096 |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL), 48-well (0.2 mL), 32-well (0.2 mL) |
| Heating Rate | 12 °C/s |
| Temperature Accuracy | ±0.1 °C (below 50 °C) |
| Well-to-Well Temperature Uniformity | ±0.2 °C (at 95 °C) |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Lifesciences Pte Ltd |
| Product Category | Imported |
| Model | UUS-363-A-1-SS |
| Configuration | Vertical |
| Effective Volume | 363 L |
| Internal Dimensions (W×D×H) | 450 × 620 × 1300 mm |
| External Dimensions (W×D×H) | 710 × 885 × 1980 mm |
| Power Supply | 230 V, 50 Hz, 12–13 A |
| Rated Power Input | 12–13 A @ 230 V, 50 Hz |
| Compliance | ANSI/ASHRAE 72-2005, ARI 1200-2006/2008, UL-certified by DNS USA |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Type | Class II, Type A2 Biosafety Cabinet |
| Model | LA2-G4 |
| Filter Efficiency | ≥99.999% (ULPA) |
| Inflow Velocity | 0.30–0.53 m/s |
| Downflow Velocity | 0.30–0.33 m/s |
| Noise Level | ≤56 dBA |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Compliance | NSF/ANSI 49-2022, EN 12469:2000, AS/NZS 2252.2:2013 |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | STI-2G / STI-3G / STI-4G |
| Air Filtration | ULPA U15 (99.9998% @ 0.12 µm) for supply air, HEPA H14 (99.997% @ 0.3 µm) for exhaust air |
| Cleanroom Class | ISO 14644-1 Class 5 (A-grade) |
| Chamber Material | Electropolished 316L stainless steel |
| Surface Roughness | ≤0.4 Ra (external), ≤0.6 Ra (internal) |
| Operating Pressure Mode | Positive or negative pressure configurable |
| Airflow Modes | Unidirectional or recirculated |
| Lighting | ≥600 lux, external-mounted LED |
| Noise Level | ≤68 dBA |
| Power Supply | 220–240 V AC, 50/60 Hz or 110–120 V AC, 60 Hz |
| Compressed Air Requirement | 6 barg, 5 L/sec |
| Exhaust Ducting | 10" diameter connection |
| Brand | Esco |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | CLM-170/240B-8-CN |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Lifesciences |
| Country of Origin | Imported |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| Model | CCL |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Product Type | Class II Type A2 Biological Safety Cabinet |
| Model | AC2-S-CN |
| Filter Efficiency | ≥99.999% for Most Penetrating Particle Size (MPPS) or ≥0.12 µm particles |
| Compliance | EN 12469, NSF/ANSI 49, YY 0569 |
| Airflow System | Constant-velocity DC ECM blower with voltage fluctuation compensation and resistance-sensing dynamic compensation |
| Surface Coating | Esco ISOCIDE antimicrobial coating |
| Construction | Seamless stainless steel work surface |
| Interface | RS-232 serial port for operational status monitoring |
| Cleanliness Class | ISO 14644-1 Class 3 (≤1,000 particles ≥0.1 µm/m³) |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | VBD-4A1 |
| Safety Class | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1247 × 760 × 1966 mm (adjustable height up to 2271 mm) |
| Internal Dimensions (L×W×H) | 1040 × 680 × 594 mm |
| Inflow Air Velocity | 0.35 m/s (70 fpm) |
| ULPA Filter Efficiency | ≥99.999% at 0.12 µm |
| Power Supply | 220–240 VAC, 50 Hz |
| NSF-Certified Waste Container Capacity | 40 US gallons (151 L) |
| Pre-filter | Polyester media, cardboard frame, 870 × 500 mm, 6 units per box |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Product Type | Class II Type A1 Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1423 × 815 × 1510 mm (VA2-4A1-E) / 2030 × 815 × 1510 mm (VA2-6A1-E) |
| Internal Work Area Dimensions (L×W×H) | 1270 × 623 × 680 mm (VA2-4A1-E) / 1870 × 620 × 680 mm (VA2-6A1-E) |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.35 m/s (70 fpm) |
| ULPA Filter Efficiency | ≥99.999% at MPPS (0.12 µm) |
| Pre-filter | Polyester, 85% arrestance |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Compliance | NSF/ANSI 49-2022, EN 12469:2000, ISO 14644-1 Class 3 (ISO 3), USP <797>, GLP/GMP-ready |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | LA2-A |
| Instrument Type | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | Model-dependent (e.g., LA2-3A: 1115 × 852 × 1540 mm) |
| Internal Dimensions (L×W×H) | Model-dependent (e.g., LA2-3A: 970 × 623 × 670 mm) |
| Inflow Velocity | 0.53 m/s (105 fpm) |
| Downflow Velocity | 0.35 m/s (70 fpm) |
| ULPA Filter Efficiency | ≥99.999% @ 0.1–0.3 µm |
| Power Supply | 220 VAC, 50 Hz |
| Compliance | NSF/ANSI 49, EN 12469, YY 0569, JIS K 3800 |
| Control System | Sentinel Gold microprocessor-based digital display with real-time monitoring |
| Optional Features | RS232 data port, night/standby mode, ISOCIDE antimicrobial coating, seamless stainless steel work surface, ergonomic tilt-angle front window (10°), ADA-compliant control panel |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Product Type | Class II, Type B2 Biosafety Cabinet |
| Filter Efficiency | ≥99.999% for MPPS (Most Penetrating Particle Size) or ≥0.12 µm particles |
| Standards Compliance | NSF/ANSI 49-2023, EN 12469:2020, YY 0569-2011 |
| Control System | Sentinel Gold™ Microprocessor-Based Controller |
| Filtration | ULPA (Ultra-Low Penetration Air) Filter |
| Airflow Design | 100% Exhaust, Non-Recirculating |
| Construction | Seamless Stainless Steel Work Surface with ISOCIDE® Antimicrobial Coating |
| Interface | RS-232 Serial Port for Operational Data Logging |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Product Category | Class II, Type B2 (Total Exhaust) Biosafety Cabinet |
| Certification | NSF/ANSI 49, YY0569 |
| Filter Efficiency | ≥99.999% for particles ≥0.1 µm (ULPA) |
| Airflow Velocity (Inflow) | 0.53 m/s (105 fpm) |
| Airflow Velocity (Downflow) | 0.31 m/s (60 fpm) |
| Power Supply | 220 VAC, 50 Hz |
| Construction | Seamless One-Piece Stainless Steel Work Chamber |
| Control System | Esco Sentinel Gold Microprocessor-Based Digital Display |
| Compliance | Meets ISO 14644-1 Class 5 (ISO Class 5), IEST-RP-CC001.3, ADA Accessibility Guidelines |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Cabinet Class | Class III |
| External Dimensions (L×W×H) | Refer to model-specific specifications |
| Internal Dimensions (L×W×H) | Refer to model-specific specifications |
| Filter Efficiency | ≥99.999% for particles ≥0.1–0.3 µm |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer | Esco Micro Pte Ltd |
| Product Category | Imported Class II Biological Safety Cabinet |
| Model | AC2-D |
| Cabinet Type | Type A2 (Recirculating/Exhaust) |
| External Dimensions (L×W×H, mm) | 1340×753×1400 (AC2-4D) / 1950×753×1400 (AC2-6D) |
| Internal Dimensions (L×W×H, mm) | 1220×580×660 (AC2-4D) / 1830×580×660 (AC2-6D) |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.30 m/s (60 fpm) |
| Filtration Efficiency | ≥99.999% @ 0.3 µm (ULPA), ≥99.995% @ 0.1 µm |
| Power Supply | 220 V, 50 Hz |
| Compliance | EN 12469:2000, NSF/ANSI 49-2022 (Class II, Type A2), ISO 14644-1 Class 5 (ISO 5) work environment |
| Surface Coating | Esco ISOCIDE® antimicrobial coating |
| Control System | EscoSentinel Gold microprocessor-based interface with real-time airflow monitoring and alarm logic |
| Communication Interface | RS-232 for BMS integration |
| Work Surface | Seamless one-piece stainless steel with integral spill containment arch |
| Structural Design | Weld-free, single-piece formed inner chamber with no seams or fasteners |
| Brand | Esco |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Temperature-Controlled Orbital Shaking Incubator |
| Speed Range | 30–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | Φ26 mm / Φ50 mm |
| Temperature Range | 4°C to 60°C (with refrigeration down to 4°C, i.e., up to 18°C below ambient) |
| Temperature Fluctuation | ±0.1°C |
| Temperature Uniformity | ±0.3°C (at 37°C, inner chamber) / ±0.5°C (at 37°C, full chamber) |
| Brand | Esco |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | Esco PCS |
| Pricing | Upon Request |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | VDA-A |
| Instrument Class | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1340 × 762 × 1961 mm / 1645 × 762 × 1961 mm |
| Internal Work Area Dimensions (L×W×H) | 1100 × 465 × 564 mm / 1405 × 465 × 564 mm |
| ULPA Filter Efficiency | ≥99.999% at MPPS (0.12 µm) |
Show next