Animal Behavior Research Instrument
Filter
Showing 31–60 of 207 results
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | ClockLab |
| Interface | USB 2.0 + RJ-45 high-throughput data acquisition |
| Max Input Channels | 448 (8 interface boxes × 56 channels each) |
| Output Channels | 64 light-control channels (8 boxes × 8 outputs) |
| Supported Species | Mus musculus, Rattus norvegicus, Mesocricetus auratus, Drosophila melanogaster, Apis mellifera, Chlamydomonas reinhardtii, Lynx lynx, Sciurus carolinensis, Thomomys bottae, Chelonia mydas, Limulus polyphemus, Homo sapiens |
| Data File Compatibility | Minimitter, Actiwatch, Dataquest, Stanford Sleep Lab formats |
| OS Support | Windows 2000/XP/Vista/7/10, macOS 9.x and macOS X (Intel & Apple Silicon via Rosetta 2) |
| Power Failure Recovery | Full session state retention and auto-resume |
| Data Export | CSV, MATLAB (.mat), XML, PNG, TIFF, PDF |
| Compliance | GLP-aligned metadata logging, FDA 21 CFR Part 11–ready audit trail (optional configuration) |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | Rotating Wheel System |
| Pricing | Available Upon Request |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Place Reference |
| Pricing | Upon Request |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | AASS |
| Sound Output Range | 20 Hz – 25.5 kHz (audio), 20 Hz – 20 kHz (white noise) |
| Max SPL | 128 dB |
| Stimulus Control | Computer-controlled amplitude, frequency, duration, rise/fall time |
| Optional Modules | Footshock (up to 3.0 mA), Visual Flash Stimulus |
| Chamber Configuration | Single or 8-chamber sound-attenuated enclosures |
| Data Acquisition | Analog signal conditioning (amplification + integration), 16-bit ADC |
| Compliance | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | ACT-100A |
| Channel Capacity | 4 / 8 / 12 channels |
| Video Sampling Rate | ≥4 Hz (frames per second) |
| Motion Detection Resolution | ≥1 mm |
| Compliance | FDA 21 CFR Part 11–ready software architecture, GLP/GMP-compatible data audit trail |
| Data Export | Excel (.xlsx), QuickTime (.mov) |
| Validated Concordance with Trained Human Observers | ≥90% (independently verified by Memory Pharmaceuticals, NJ) |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | ACT-300A |
| Application | Video-based automated tracking for open field, elevated plus maze, radial arm maze, zero maze, conditioned place preference, and custom arena designs |
| Tracking Capacity | Up to 4 animals simultaneously |
| Frame Rate | 15 fps per animal (7 fps when tracking 4 animals) |
| Animal Detection | Robust real-time detection of black or white rodents regardless of size |
| Data Output | Time-in-zone (s/%), zone entries/crossings, path length (cm), body length (mm), orientation angle, mean distance from center, trajectory coordinates, and exportable CSV/Excel reports |
| Software | Limelight v5.x with GLP-compliant audit trail, batch processing, group-wise statistical summary (mean ± SEM), QuickTime movie export, and customizable zone/grid/maze-arm segmentation |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | ACT-400 |
| Camera Channels | 1–4 (expandable) |
| Max Simultaneous Subjects | >200 (50+ per camera) |
| Tracking Frequency | 4 Hz per subject (subject-count dependent) |
| Data Output | CSV, Excel-compatible, ClockLab-compatible |
| Event Marking | Multi-channel timestamped annotations |
| ROI Configuration | User-defined arbitrary zones per camera view |
| IR Sensitivity | Near-infrared optimized (750–950 nm), enabling dark-phase monitoring |
| Software Platform | BigBrother Analysis Suite + ClockLab integration |
| Compliance | GLP-supportive audit trail (software-configurable), FDA 21 CFR Part 11 ready (with optional validation package) |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | FREEZEFRAME-FW |
| Camera Interface | Standard CCD or USB 2.0/3.0 Video Input |
| Operating System | Windows 10/11 (64-bit) |
| Data Output Format | CSV, Excel-compatible, XML |
| Compliance | GLP-supporting audit trail logging (configurable), ISO/IEC 17025-aligned data integrity framework |
| Analytical Output | Immobility duration (s), immobility bouts count, latency to first immobility, total active time (swimming/climbing), motion velocity (px/frame), trajectory heatmaps |
| Software Architecture | Client-server capable, multi-user role-based access control (RBAC) |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | FREEZEFRAME-XW |
| Application | Automated video-based behavioral analysis for murine tail suspension assay |
| Compliance | Designed for GLP-compliant preclinical neuroscience research |
| Data Output | CSV, Excel-compatible, QuickTime export |
| Camera Frame Rate | ≥4 fps |
| Multi-animal Support | Configurable for 4, 8, or 12 subjects simultaneously |
| Motion Detection Algorithm | Patented shadow- and noise-immune motion index computation |
| Software Architecture | Modular, Windows-based, FDA 21 CFR Part 11–ready audit trail optional |
| Brand | Coulbourn |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSE-01001 |
| Pricing | Upon Request |
| Channel Configurations | Single-, Dual-, and 5-Channel Options |
| Speed Control | Programmable Constant & Accelerating Profiles |
| Incline/Decline Adjustment | ±25° Motorized |
| Shock Absorption | Adjustable Compliance Damping |
| Detection Method | Top-Mounted Photobeam Sensors |
| Timing Resolution | 0.1 s Per Chamber |
| Noise Level | <45 dB(A) at 1 m |
| Structural Frame | Powder-Coated Steel with Polycarbonate Enclosures |
| Compliance | Designed for ASTM F2100-22 (Laboratory Equipment Safety), ISO 13485-aligned Manufacturing Practices, GLP-Ready Data Logging |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Operant Behavior Systems |
| Pricing | Available Upon Request |
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Rotation Monitor |
| Cage Dimensions | 4" (D) × 3" (W) × 2" (H), 18" ramped cylinder |
| Material | Aluminum, Polypropylene |
| Max. Simultaneous Monitoring Capacity | 64 cages |
| Resolution | 0.01 rad (3.6°) |
| Detection Method | Triple Infrared Transceiver per Station |
| Cable Length | 12 ft |
| Certification | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DigiGait™ |
| Pricing | Upon Request |
| Brand | DS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Rat Metabolic Cage |
| Model | DXL-D |
| Dimensions (L×W×H) | 300 × 300 × 650 mm |
| Material | Medical-grade Polycarbonate (PC) |
| Urine/Feces Separation | Dual-channel conical funnel system with anti-evaporation urine collector and non-adhesive fecal collection tube |
| Assembly | 15 modular components, tool-free disassembly |
| Compliance | Designed for GLP-compliant preclinical studies in pharmacology, endocrinology, and nutrition research |
| Brand | Panlab |
|---|---|
| Country of Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VivaMARS |
| Pricing | Available Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LoliTrack |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Elevated Plus Maze |
| Pricing | Upon Request |
| Brand | KISSEI |
|---|---|
| Origin | Japan |
| Model | BAS-8103 |
| Power Supply | +5 V ±5% (from PC AD card) |
| Current Consumption | < ±2.8 mA |
| Input Connector | 2-pin socket |
| Number of Channels | 3 |
| Gain Settings | 100, 200, 500, 1000 µV/V |
| Low-Pass Filter Cutoff Frequencies | 100, 250, 500, 1000 Hz |
| High-Pass Filter Cutoff Frequencies | 0.5, 2, 5, 10 Hz |
| Input Impedance | > 10 MΩ |
| Input-Referred Noise | < 5 µVp-p |
| Weight | < 40 g |
| Dimensions | 65 × 35 × 100 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FST-00 |
| Pricing | Available Upon Request |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | GD-1 |
| Type | Double-Bore Borosilicate Glass Capillary Tube |
| Material | High-Purity Borosilicate Glass (e.g., SCHOTT 8330 or equivalent) |
| Outer Diameter | 1.5 mm |
| Inner Diameter (each lumen) | 0.75 mm |
| Wall Thickness | 0.375 mm |
| Length | 100 mm |
| Sterilization Compatibility | Autoclavable (121°C, 20 min), Ethylene Oxide, and Gamma Irradiation |
| Packaging | Individually wrapped in sterile blister packs or bulk in Class 100 cleanroom bags |
| Compliance | ISO 13485–certified manufacturing, USP <381> compliant glass composition |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HOMECAGE |
| Price Range | USD 1,400 – 7,000 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE507 / LE509 / LE512 |
| Dimensions (LE509 internal) | 252 × 280 × 240 mm |
| Dimensions (LE507 internal) | 190 × 220 × 240 mm |
| Aperture diameter (rat) | 23 mm, depth: 14 mm |
| Aperture diameter (mouse) | 13 mm, depth: 10 mm |
| Construction | Acrylic, aluminum alloy, stainless steel |
| Max simultaneous chambers per software instance | 8 |
| Sensor type | Infrared nose-poke detectors (per aperture and food tray) |
| Visual cue | Adjustable-brightness LED stimulus lights (per aperture) |
| Actuation | Motorized aperture shutters (individually controllable) |
| Reward delivery | Pellet dispenser (LE507/LE509), integrated per-aperture reward dispensers (LE512) |
| Software | Panlab PackWin v3.x (Windows-based, GLP-compliant experimental control & data acquisition) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE7106 |
| Stimulus Source | Halogen lamp |
| Max Stimulus Temperature | 250 °C |
| Ramp Time (40 °C → 250 °C) | ≤10 s |
| Default Cut-off Time | 20 s |
| Adjustable Cut-off Time | Yes |
| Temporal Resolution | 0.1 s |
| Display | 4-digit LED |
| Dimensions (Controller) | 350 × 350 × 130 mm |
| Dimensions (Stimulator) | 400 × 140 × 155 mm |
| Housing Material | Methyl methacrylate |
| Animal Weight Range | 20–400 g |
| Compliance | CE certified |
| Interface | RS232 |
| Optional Software | SeDaCom |
| Footswitch | Included |
| Tail Restraint | Adjustable groove-based fixture for mice and rats |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE7306 |
| Maximum Applied Force | 999 g |
| Resolution | 1 g |
| Tip Diameter Options | 1 mm (flat-tipped and conical-tipped) |
| Stimulus Probe Material | Acrylic (methyl methacrylate) |
| Compliance | CE-certified |
| Control Unit Dimensions (W × D × H) | 350 × 350 × 130 mm |
| Stimulator Unit Dimensions (W × D × H) | 150 × 210 × 166 mm |
| Software | SeDaCom v3.x for automated data acquisition, timestamped event logging, and statistical export (CSV, Excel-compatible) |
| Actuation | Stepper motor-driven linear displacement with real-time load cell feedback |
| Footswitch | Integrated remote foot pedal for hands-free start/stop and auto-return activation |
| Base Design | Rotational pivot mount to prevent lateral torque and excessive localized pressure on paw tissue |
| Display | Digital LED readout showing real-time force (g) and directional status |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LE830 |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Chamber Dimensions (H × W × D) | 16 × 25 × 18 cm |
| Construction Material | Optical-grade acrylic panels with stainless steel and white/transparent polymer inserts |
| Electric Shock Stimulus | 0–3 mA (square-wave, constant-current), programmable duration 0–10 s, foot-switch actuated |
| Required Ancillary Systems | HD video acquisition system (e.g., 60 fps USB3 camera with IR illumination), SMART 3.0 Behavioral Tracking Software (v3.0 or later) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE902 |
| Rotation Sensor Type | High-resolution bidirectional optical encoder |
| TTL Digital Output | Yes |
| Angular Resolution | Adjustable from 4 to 36 segments per full revolution |
| Recording Modes | Full and partial left/right rotations |
| Time Interval Logging | User-defined (e.g., 1 min, 5 min, 30 min bins) |
| Experimental Chamber Options | 400 mm diameter × 200 mm height circular bowl OR 400 mm diameter × 300 mm height cylindrical chamber |
| Tether Material | Flexible, low-torque silicone tether |
| Data Acquisition Software | SEDACOM V2.0 |
| Compliance | Designed for preclinical behavioral phenotyping in GLP-aligned research environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Packwin 2.0 |
| Price Range | USD 1,400 – 7,000 |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iSCOUT |
| Price Range | USD 1,400 – 7,000 |
| Camera Resolution | 10 MP |
| Memory | 1 GB |
| Imaging Frequency | Up to 3 times per day (configurable) |
| GPS Integration | Built-in |
| Power Supply | Rechargeable Li-ion battery + 7.2 V / 333 mA solar panel (18 × 13 cm) |
| Dimensions | 20 × 15.5 × 17 cm |
| Weight | 930 g |
| Wireless Connectivity | Cellular (LTE-M/NB-IoT) or LoRaWAN |
| Data Platform | FieldClimate® cloud service |
| Coverage per Unit | 1–5 hectares |
| Trap Types | Pheromone-based, Drosophila-specific, General insect, Chromatic (blue/yellow/white) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | InfraMot – Activity System |
| Detection Principle | Passive Infrared (PIR) Thermal Imaging |
| Measurement Type | Total Locomotor and Postural Activity |
| Cage Compatibility | Universal (all standard rodent housing sizes) |
| Installation | Top-mounted or flexible spatial positioning |
| Light Condition Independence | Full spectrum — operates in total darkness |
| Temporal Resolution | Millisecond-level motion event detection |
| Calibration | Zero-calibration required |
| Integration | Modular component of PhenoMaster® and LabMaster® platforms |
| Cleaning | Removable sensor unit for routine decontamination |
| Compliance | Designed for GLP-compliant longitudinal phenotyping studies |