Animal Behavior Research Instrument
Filter
Showing 91–120 of 207 results
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MSZ-1 |
| Pricing | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MTS-1 |
| Pricing | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MYS-1 |
| Pricing | Upon Request |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | EG-45 |
| Motor Speed | 150–2,100 rpm (diamond wheel stoppable at 150 rpm) |
| Vertical Manipulator Travel | ~47 mm |
| Capillary Diameter Range | Ø1.0–Ø1.5 mm |
| Operating Voltage | AC 100–240 V, 50/60 Hz |
| Power Consumption | 10 W |
| Dimensions (W×D×H) | 185 × 165 × 310 mm |
| Weight | 2.4 kg |
| Includes | Vertical Grinding Adapter, Dedicated Capillary Holder, Power Cord, Hex Wrench |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VisioTracker by NewBehavior |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NM42-060H-I |
| Quotation | Upon Request |
| Magnetic Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Dedicated Animal RF Coil Diameter | 60 mm |
| Species Compatibility | Live mice and rats |
| Primary Application | In vivo glioma modeling, tumor progression monitoring, therapeutic response assessment, contrast agent evaluation |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-I |
| Magnetic Field Strength | 1.0 ± 0.05 T |
| Larmor Frequency | ~42 MHz |
| Gradient Coil Bore Diameter | 60 mm |
| Magnet Type | Permanent Magnet |
| Application Scope | In vivo small animal MRI (mouse/rat), contrast agent evaluation, tumor monitoring (brain, subcutaneous, liver), obesity phenotyping, longitudinal therapeutic response assessment |
| Compliance | Designed for GLP-aligned preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | QMR Series |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR Series |
| Pricing | Available Upon Request |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Animal Behavior Monitoring & Analysis System |
| Pricing | Available Upon Request |
| [Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model Range | NORT-3D Series |
| Price Range | USD 1,400 – 7,000] |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Open Field Test System |
| Pricing | Available Upon Request |
| Brand | Panlab / Harvard Apparatus |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Touch-Test™ Electronic Von Frey Anesthesiometer |
| Measurement Range | 0–500 g (±20% overload tolerance) |
| Display Resolution | 0.1 g |
| Measurement Accuracy | ±0.2 g |
| Operating Temperature | 0–50 °C |
| Statistical Capacity | Mean, Standard Deviation, Coefficient of Variation (up to 100 animal records) |
| Compliance | ISO 9001 certified, EMC compliant |
| Interface | RS-232 serial output, optional footswitch control |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | BIO-TST4 |
| Sensor Type | Precision Load Cell (Gravity-Based Force Transduction) |
| Output Parameters | Immobility Time (s), Immobility Ratio (%), Mean Struggling Force (mN), Energy Expenditure (mJ), Threshold-Adjustable Immobility Detection |
| Connectivity | USB 2.0 |
| Max Concurrent Units per PC | 6 |
| Animal Capacity | 3–6 mice (configurable 3×2 array) |
| Housing Material | Black-and-White Acrylic Enclosure with Stainless Steel Hooks |
| Optional Integration | SMART 3.0 Video Analysis Module (add-on) |
| Data Export | CSV/Excel-compatible format |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE862 / LE865 |
| Stimulus Range | 0.1–2 mA (LE10025 Electrode Stimulator), Pulse Duration: 0.1–10 s |
| Detection Resolution | Single-lick resolution via patented sipper-tube sensor |
| Cage Capacity | Up to 32 cages per PC (with PACKWIN software) |
| Onboard Memory | 99 drinking events per detector |
| Compliance | Designed for GLP-aligned behavioral phenotyping workflows |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Panlab Drinko-Lick |
| Price | USD 13,800 (approx.) |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Dynamic Weight Bearing System |
| Animal Compatibility | Mice (15–50 g), Rats (150–500 g) |
| Force Resolution | 0.2 g (mice), 0.8 g (rats) |
| Force Accuracy | ±1 g |
| Data Synchronization | Real-time video-embedded force recording via USB |
| Output Format | Native Excel (.xlsx) |
| Compliance | Designed for GLP-aligned preclinical behavioral phenotyping |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LE840 (Rat), LE842 (Mouse), H10-35-EPM (Universal) |
| Dimensions | LE840 — Enclosed Arms: 1000 × 1000 × 500 mm (gray walls) |
| Open Arms | 100 × 450 mm |
| LE842 — Enclosed Arms | 650 × 650 × 150 mm (gray walls) |
| Open Arms | 60 × 295 mm |
| H10-35-EPM — Arm Width | 250 px (≈63.5 mm), Arm Length: 1250 px (≈317.5 mm), Wall Height: 750 px (≈190.5 mm), Platform Height: 1375 px (≈349.3 mm) |
| Material | Cast Methyl Methacrylate (PMMA), Anodized Aluminum Frame |
| Transparent Wall Height | 30 mm (rat), 18 mm (mouse) |
| Tracking Compatibility | Manual Scoring or Video-Based Analysis with SMART 3.0 Software Suite (sold separately) |
| Output Metrics | Position Coordinates, Time Spent per Zone, Total Path Length, Instantaneous & Average Velocity, Arm Entries, Latency to First Entry |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Fear |
| Animal Weight Range | 15–500 g |
| Interface | USB |
| Compliance | GLP-ready data traceability |
| Software Platform | PackWin 2.0 with Startle & Freezing Modules |
| Sensor Type | High-sensitivity load-cell-based motion transducer |
| Configurable Stimulus Outputs | Auditory (broadband noise, tone bursts), Visual (LED flash), and Aversive (foot shock via optional stimulator) |
| Enclosure Options | Acoustic isolation chamber (standard), transparent or opaque test cages |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE810 (mouse), LE812 (rat), LE816 (mouse, automated), LE818 (rat, automated) |
| Chamber Dimensions (mouse) | Light chamber 240 × 250 × 250 mm |
| Chamber Dimensions (rat) | Light chamber 240 × 310 × 310 mm |
| Detection | Load-cell-based position sensing |
| Interface | RS-232 serial communication |
| Software | PPCWIN v3.x (Windows-compatible) |
| Compliance | Designed for GLP-aligned behavioral phenotyping workflows |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE895/6/7/8 |
| Detection Method | Video Tracking (SMART 3.0) or Load-Cell-Based Gravimetric Sensing (PPCWIN) |
| Max Concurrent Units | 8 chambers per PC |
| Rat Chamber Assembly | 88 × 47 × 1125 px (L×W×H) |
| Compartment | 40 × 34 × 1125 px |
| Passage | 25 × 13 × 1125 px |
| Mouse Chamber Assembly | 46 × 27 × 625 px |
| Compartment | 20 × 18 × 625 px |
| Passage | 20 × 7 × 625 px |
| Construction | Optical-grade acrylic |
| Configurable Cues | Interchangeable wall textures/colors, modular floor substrates (tactile/visual), repositionable 3D spatial dividers |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Hot Plate Analgesia Meter |
| Temperature Range | 35–65 °C |
| Temperature Accuracy | ±0.3 °C |
| Timer Resolution | 0.1 s |
| Timer Range | 0–9 min 59 s |
| Compatible Species | Mice and Rats |
| Regulatory Compliance | Designed for GLP-compliant preclinical pain research |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE 7406 |
| Heating Plate Material | Pure Aluminum |
| Heating Plate Dimensions (D × T) | 200 mm × 10 mm |
| Base Dimensions (L × W × H) | 200 mm × 300 mm × 110 mm |
| Cylinder Dimensions (D × H) | 200 mm × 250 mm |
| Temperature Range | 45–62 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Time Resolution | 0.1 s |
| Input Control | Footswitch-activated timing |
| Data Output | RS-232 serial interface |
| Compliance | CE-marked |
| Optional Software | SeDaCom |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Hot-Plate Thermal Analgesia Meter |
| Temperature Range | 45–62 °C |
| Temperature Accuracy | ±0.1 °C |
| Timer Resolution | 0.1 s |
| Heating Plate Material | 10 mm Aluminum |
| Safety Protection | Multi-circuit Electronic Over-Temperature Control |
| Interface | Built-in LCD Display + Footswitch Input + SEDACOM Software Connectivity |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | HotCold Plate |
| Temperature Range | -3 °C to +65 °C (ambient 20–25 °C) |
| Temperature Stability | ±0.5 °C (mean, plate surface) |
| Temperature Uniformity | ±0.1 °C under 400 g load |
| Ramp Rate | <10 min from ambient to 4 °C |
| Control Software | BSRamp (custom ramp profiles, time-stamped storage) |
| Compliance | EEC metrological standards for laboratory thermal instrumentation |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE116 |
| Price Range | USD 1,400 – 7,000 |
| Dimensions | 250 × 250 × 250 mm (L×W×H) |
| Animal Weight Range | 15–500 g |
| Acoustic Stimulus Range | 200–10,000 Hz, 60–120 dB |
| Sensor Technology | Precision Load Cell-Based Gravimetric Detection |
| Stimuli Control | Programmable Light, Tone, Foot Shock, Air Puff |
| Max Simultaneous Units | 8 per PC |
| Software Modules | PACKWINCS-FR (Fear Conditioning), PACKWINCS-ST (Startle Reflex) |
| Environmental Configurability | Interchangeable Floor/Wall Panels, Modular Chamber Geometry (Square, Circular, Triangular) |
| Compliance | Designed for GLP-compliant behavioral phenotyping workflows |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE116 |
| Price | USD 14,000 (approx.) |
| Sensor Sensitivity | 10 mg – 2 kg |
| Chamber Dimensions | 250 × 250 × 250 mm (W×D×H) |
| Sound Frequency Range | 200–10,000 Hz |
| Sound Intensity | Up to 120 dB SPL |
| White Noise Range | 60–120 dB SPL |
| Max Channels per PC | 8 |
| Floor Grid Options | 6 mm or 10 mm spacing |
| Construction Materials | Sandwiched acrylic, aluminum alloy, stainless steel |
| Compliance | CE Marked |
| Power Supply | 110/220 V, 50/60 Hz |
| Animal Weight Range | 15–500 g |
| Software | PACKWIN V2.0 with STARTLE and FREEZING modules |
| Optional Hardware | Pneumatic startle (LE119), electric shock generator (LE10026), environmental configuration kits (LE115), species-specific restraints (LE117 series), stimulus interface modules (LE118 / LE1188) |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | LE7106 |
| Animal Compatibility | Mice and Rats |
| Stimulus Source | Halogen Heating Lamp |
| Control Interface | Footswitch-Activated Electronic Control Unit |
| Measurement Principle | Radiant Heat–Induced Nocifensive Withdrawal Reflex Timing |
| Compliance | Designed for GLP-aligned preclinical analgesia studies |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | LE7306 |
| Device Type | Electronic Dynamic Pressure Stimulator for Hindpaw Withdrawal Threshold Measurement |
| Compliance Context | Designed for preclinical pain research in accordance with IASP guidelines and standard rodent behavioral assay protocols (e.g., Randall–Selitto test) |
