| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | InfraMot |
| Detection Principle | Passive Infrared (PIR) Thermal Imaging |
| Spatial Resolution | Cage-wide volumetric activity mapping |
| Temporal Resolution | Millisecond-level motion event detection |
| Installation | Top-mounted modular sensor unit compatible with PhenoMaster/LabMaster caging systems |
| Calibration | Factory-calibrated, zero user calibration required |
| Environmental Operation | Full light-independence (operational in total darkness or standard lighting) |
| Cage Compatibility | Universal fit for standard and custom rodent housing dimensions |
| Hygiene Design | Tool-free removable sensor head for autoclave-compatible cleaning |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | IntelliCage Add-On AnimalGate |
| Type | Modular RFID-Based Animal Access Gate for Automated Behavioral Phenotyping |
| Compliance | CE-marked, compatible with GLP-compliant data workflows |
| Software Integration | Fully controlled via IntelliCage Plus v5.0+ (FDA 21 CFR Part 11–ready audit trail, electronic signature support) |
| Optional Hardware | Integrated high-precision load cell (±0.1 g resolution, 500 g max capacity) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | IntelliCage Add-On SocialBox |
| Type | RFID-Based Automated Social Behavior Monitoring Module for Mouse Ethology |
| Compatibility | Designed exclusively for IntelliCage Plus and IntelliCage Pro systems |
| Max Expansion | Up to 4 SocialBoxes per IntelliCage unit (5 total zones) |
| System Scalability | Up to 8 IntelliCage units or 32 SocialBoxes (128 mice) |
| Software Control | IntelliCage Plus v5.0+ with audit-trail-enabled experimental protocol scheduling |
| Regulatory Alignment | Compliant with GLP-compliant data integrity requirements |
| Brand | Kissei |
|---|---|
| Origin | Japan |
| Model | BAS Series |
| Channel Configuration | 2-Channel (1×EEG + 1×EMG) or 3-Channel (2×EEG + 1×EMG) |
| Compliance | CE-marked for research use only |
| Intended Use | Chronic in vivo electrophysiology in freely moving rodents |
| Brand | KISSEI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Kinema Tracer 3D |
| Price Range | USD 14,000 – 70,000 |
| Brand | KISSEI |
|---|---|
| Origin | Japan |
| Model | Nanotag |
| Communication | FeliCa®/NFC (ISO/IEC 18092) |
| Operating Distance | ~10 mm |
| Time Accuracy | ±60 sec/month |
| Battery Life | Up to 60 days (24-hr recording + 2-min daily data transfer) |
| Recording Modes | Cyclic, Memory-Hold-Stop, Time-Scheduled Start/Stop |
| Activity Measurement | Cross-count detection |
| Temperature Range | 30–45.87 °C |
| Temp. Resolution | 0.0625 °C |
| Temp. Accuracy | ±0.5 °C |
| Enclosure Rating | IPX7 (IEC 60529) |
| Housing Materials | ABS plastic + epoxy encapsulation |
| Dimensions | 15 × 14.2 × 7.1 mm |
| Weight | 2.5 g |
| Data Retrieval | Contactless FeliCa® interrogation via compatible reader |
| Brand | Kissei |
|---|---|
| Origin | Japan |
| Model | SleepSign |
| Import Status | Imported |
| Distribution Type | Authorized Distributor |
| Price Range | USD 7,000 – 14,000 (FOB Japan) |
| Brand | Kissei |
|---|---|
| Origin | Japan |
| Model | SleepSign |
| Device Type | Electrophysiological Sleep Stage Monitoring and Closed-Loop Deprivation System |
| Regulatory Classification | Research-Use-Only (RUO) Instrument for Preclinical Neuroscience |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 80600A-CP |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 80805A*C (Rat), 80800A*C / 80800A10*C (Mouse) |
| Weight | 9.1 kg (base only), 18.6 kg (fully configured with 6 rat wheels) |
| Dimensions (with wheels) | 130 cm × 46 cm × 43 cm |
| Wheel Diameter (rat) | 33.985 cm |
| Wheel Width (rat) | 11.176 cm |
| Circumference (rat) | 1.06 m/rev |
| Circumference (mouse) | 0.47 m/rev |
| Speed Range (rat) | 1.0–28.0 m/min |
| Speed Range (mouse) | 0.9–11.4 m/min |
| Time Resolution | 1 sec |
| Rest/Test Duration | 1 min – 24 h |
| Revolutions | 1–99 (rat), 1–999 (mouse) |
| Runway Capacity | 1–6 (rat), 1–20 (mouse) |
| Material | Polycarbonate sidewalls, aluminum access hatches, stainless-steel rung surface, padded non-slip clamps |
| Waste Trays | 3 removable stainless-steel trays |
| Optional Accessories | Tail restraint nets (80806MSH18, 80801MSH25), drinking support kits (80807, 80803), Model 86165 AWM software (USB/serial compatible) |
| Brand | Lafayette (USA) |
|---|---|
| Manufacturer | RWD (Shenzhen, China) |
| Model | 80950*C |
| Origin | China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Configuration | Standalone touchscreen station with integrated CPU (1.6 GHz), calibrated peristaltic pump (0.203 mL/s), lick sensor, IR touch LCD (12.2 mL liquid reward capacity), reinforced stainless-steel frame, fan-cooled enclosure, audio cue speaker, and embedded CANTAB/Whisker software suite |
| Compliance | Designed for GLP-aligned primate behavioral research in accordance with NIH Guide for Care and Use of Laboratory Animals and ASTM E2575–22 (Standard Practice for Behavioral Testing of Nonhuman Primates) |
| Sample Compatibility | Rhesus macaques (Macaca mulatta) and cynomolgus macaques (Macaca fascicularis) |
| Deployment | Single-station or networked multi-station configuration via standard Ethernet (TCP/IP) |
| Brand | RWD |
|---|---|
| Origin | USA |
| Manufacturer | RWD Life Science |
| Product Type | Imported Instrument |
| Model | Lafayette Autonomous Activity Wheel System |
| Price | USD 14,000 (approx.) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | 80300 (Rat), 80301 (Mouse) |
| Price | USD $14,500 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 80391 |
| Price | USD $14,200 (approx.) |
| Power Supply | 9 V DC, 2 A |
| Scan Cycle | 7.5 s |
| Adjustable Scan Intervals | 0.25, 0.5, 1, 1.5, 2, 3, 4, 5, 10, 15, 20, 25, 30 min |
| External Dimensions | 40.6 cm L × 26.7 cm W × 36.8 cm H |
| Internal Chamber Dimensions | 24.4 cm L × 21.0 cm W × 19.7 cm H |
| Species Compatibility | Rats and Mice |
| Environmental Provision | Ad libitum food and water access |
| Actuation Mechanism | Dual-compartment motorized scanning bar system |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 80870 |
| Price | USD 13,500 (FOB) |
| Dimensions (Overall) | 48.26 cm × 22.86 cm × 18.54 cm |
| Chamber Dimensions (per side) | 20.23 cm × 11.18 cm × 11.68 cm |
| Detection System | Dual industrial-grade optical detectors |
| Construction Material | 316 stainless steel |
| Display | Integrated LCD digital counter |
| Optional Accessories | Model 86060 digital event counter (2 units), Model 80875 training funnel |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LE509 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Learned Helplessness I+II |
| Pricing | Upon Request |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Light-Dark Test |
| Configuration Options | Two- or Three-Compartment Chamber (Single- or Dual-Animal Setup) |
| Integration | Compatible with TSE PhenoMaster®, VideoMot2® video tracking, ActiMot2® infrared beam frame, TSE Conditioning Systems & Multi-Conditioning Systems |
| Species | Mice and Rats |
| Regulatory Context | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | Loligo Systems |
|---|---|
| Origin | Denmark |
| Model | Fish Swimming Performance System |
| Flow Velocity Range | 0.7–200 cm/s |
| Chamber Options | Mini (SW10000, SW10030), Large (SW10050–SW10200), Extra-Large (SW10250, SW10300) |
| Software | AutoSwim v5.x |
| Calibration Options | DPTV Particle Tracking (Mini chambers) or Handheld Pitot-Style Flow Probe (0.01–3 m/s, Large/Extra-Large chambers) |
| Sample Mass Range | 1 g – 15 kg |
| Max Simultaneous Chambers per PC | 7 |
| Unit Flexibility | cm/s, BL/s, body lengths per second |
| Solid Blocking Correction | Yes |
| Compliance Support | ASTM E2917-22 (Standard Practice for Determining Critical Swimming Speed of Fish), ISO 10872:2021 (Aquatic Toxicology — Measurement of Locomotor Performance) |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MDS-1 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | SR-100 Series Startle Response & Fear Conditioning System |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | Fear Conditioning System |
| Pricing | Available Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | MGS-1/4 |
| Price | Upon Request |
| Brand | Mightex |
|---|---|
| Origin | Canada |
| Model | OASIS Implant |
| Type | Reconfigurable Intracranial Optical Interface Platform |
| Compatibility | GRIN lens-coupled, SMA-fiber-integrated, C-mount camera-ready |
| Weight (headstage) | 0.7 g |
| Optical Path | Dual-mode (imaging + stimulation via shared imaging fiber) |
| Resolution | Single-cell level (dependent on GRIN lens & camera sensor) |
| Illumination Flexibility | Multi-wavelength, patterned (via Polygon400), widefield, or targeted |
| Software | Mightex OASIS Acquisition & Analysis Suite (synchronized behavioral integration, ΔF/F₀ extraction, cell segmentation, spike inference) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Morris |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Morris |
| Pricing | Upon Request |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Motor Function & Performance |
| Type | Integrated Behavioral Phenotyping Platform for Rodent Motor Assessment |
| Application Domain | Preclinical Neuroscience, Neurodegeneration Research, Neuromuscular Pharmacology, Toxicology Screening |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DigiGiat |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Species Compatibility | Mouse, Rat, Guinea Pig |
| Treadmill Speed Range | 0–25 cm/s |
| Incline/Decline Adjustment | ±15° |
| Imaging | High-Speed Monochrome Camera (≥200 fps), Cold-LED Illumination |
| Data Output | Spatial-Temporal Parameters (Stride Length, Stance Duration, Swing Phase, Paw Angle, Inter-Limb Coordination), Pressure-Weighted Contact Area (Relative Intensity Mapping) |
| Software | DigiGiat v3.2 with Automated Paw Detection, Kinematic Event Tagging, and Export to CSV/Excel |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DigiGait™ |
| Price | USD 13,800 (FOB) |
| Camera Frame Rate | ≥150 fps |
| Temporal Resolution | <10 ms |
| Treadmill Speed Range | 0–100 cm/s (1 mm/s increment) |
| Incline Adjustment | 0–60° |
| Animal Compatibility | Mice, Rats, Guinea Pigs |
| Treadmill Belt Material | Reusable High-Grip Polymer |
| Illumination | 90–250 V AC, 25 kHz, 5000 K CCT |
| Software Output Parameters | >50 spatiotemporal gait metrics including stance duration, swing duration, stride length, paw angle, inter-limb coordination indices, Sciatic Functional Index (SFI), and preconfigured Excel-compatible reports |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DigiGait |
| Speed Range | 0–100 cm/s (1 mm/s resolution) |
| Incline Adjustment | 0–60° |
| Camera Frame Rate | ≥150 fps |
| Temporal Resolution | <10 ms |
| Lighting | 25 kHz, 5000 K, 90–250 V AC |
| Treadmill Belt | Reusable polymer, high-traction |
| Animal Compatibility | Mice, rats, guinea pigs |
| Software | Proprietary DigiGait v8.x with automated paw detection and >50 spatiotemporal gait metrics |
| Compliance | Designed for GLP-compliant preclinical research environments |